plumbing 03122019INSPECTION WORKSHEET (RPLUM-001384-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0043-2019Case Module:Permit
Inspection Date:Tue Mar 12, 2019Inspection Status:Partial Pass
Inspector:Charles DyerInspection Type:Rough Plumbing
Job Address:61 JOHN CLENDON RDParcel Number:295.15-2-12
Queensbury, NY 12804
Contact TypeCompany NameName
ApplicantFOOTHILLS BUILDERS, LLC
ContractorFOOTHILLS BUILDERS, LLC
Granted PermissionFOOTHILLS BUILDERS, LLC
EngineerVision Engineering
Primary OwnerFOOTHILLS BUILDERS, LLC
Checklist ItemPassedComments
Building Inspector NotesNOWill need to provide air test for connections at main sewer
line through foundation to septic tank. 3/12/19
Plumbing Under SlabNO
Rough Plumbing / Nail PlatesYES
Plumbing Vent Vents in PlaceYES
3" Vent Through RoofYES
1 ½ inch minimum Drain SizeNO
Mar 12, 2019Page (1)
INSPECTION WORKSHEET (RPLUM-001384-2019)
Checklist ItemPassedComments
Shower liner test (2" of water)NO
Washing Machine Drain 2 inch minimumYES
Washing Machine Trap: 18"-24" dischargeYES
Pressure TestYES
Drain VentYES
Air HeadYES
5 psi or 10 ft. above highest conn. for 15 minutesYES
Pressure TestYES
Water Supply PipingYES
Air HeadNO
50 P.S.I for 15 minutesYES
Air Test Gas Piping 10 psi for 10 MinutesNO
All Return Air Hard Duct WorkNONot installed at time of inspection
Duct Insulation - if required in unheated spacesNO
Duct Testing Outside Conditioned SpaceNO
Duct work sealed properlyNO
Dyer, Charles (Inspector)