Loading...
RC-0433-2019 TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5904 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 BUILDING PERMIT RC-0433-2019 Permit Number: 308.7-1-59 Tax Map No: Hodorowski Homes Permission is hereby granted to: 95 RICHMOND HILL DR For property located at: In the Town of Queensbury, to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Mission Builders$200,000.00 Owner Name:Single Family - New $200,000.00 Owner Address:796 Burdeck ST Total Value Schenectady, NY 12306 Contractor or Builder's Name / AddressElectrical Inspection Agency Hodorowski Homes 796 Burdeck ST Schenectady, NY 12306 Plans & Specifications Single Family Dwelling w/gas FP 2498 s.f. Garage 437 s.f. Barringer Heights lot 12 $1,899.40 Thursday, July 2, 2020 PERMIT FEE PAID - THIS PERMIT EXPIRES: (If a longer period is required, an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Wednesday, July 3, 2019 Dated at the Town of Queensbury; SIGNED BY:for the Town of Queensbury. ________________________________ Director of Building & Code Enforcement Office Use Only t ,( — PRINCIPLE STRUCTURE PERMIT Permit#: �' .3--> ' 2 � Permit ON Fee: $ *Rec. Fee: $ e'5`2 742 Bay Road., Queensbury, NV 12804 P: 518-761-8256 ,:,w:: •i:e-,: Invoice #: 11'12- Project Location: q 5 iC�'1mDnC't 4 11 Dr Tax Map #: 3 0 8. 7 - 1 - 59 Subdivision Name: 'an r ri nr- 1-4-e;# -s i TOWN BD.RESOLUTION 86-2013:$850 recreation fee for new dwelling units: single family. duplexes/two-family, multiple family, apartments. condominiums townhouses,and/'or manufactured & modular homes. but not mobile IIhomes. This is in addition to the permit fee(s). CONTACT INFORMATION: • Applicant: Name(s): (-f nC 'ou 3 1---1L,me5 Mailing Address, C/S/Z: 79(, Tt,Lrcec 34 Sthen edad4 , l'/Y /a 30(a Cell Ph.: ( ) Land Line: (54 `5 354, -/'-/35 Email: tlai a. Ca. hoc(ocou k►lrou.p.Ccwn • Primary Owner(s): Name(s): N.\t Ssion LI► 1 c\.ec 5 Mailing Address, C/S/Z: 79(0 rciccl St 3chenedat13, N? M,220(Q Cell Ph.: ( ) Land Line: (s 7, ) 35G - /`-35 Email: L, 4 (q', In roli�s .yowe• Ct'►-n • Cont1ractor(s): Name(s): kod c 0gk-a I--1orrr -- Mailing Address, C/S/Z: 79(.0 urckerac - rI1Pnec-Fact43) NY /230(o Cell Ph.: _( ) Land Line: _( 518 ) 35(0 -/43 Email: pro_it ._ 1nacApcounk,;yo . Corn • Architects)/Enqineer(s): Name(s): 1\10f-- 3-t-ar Nome IDe_si n'3 h � Mailing Address, C/S/Z: 35 Cnerrc,� c Lane. i 1+0 r N Y Cell Ph.: _( ) J Land Line: _( 5/8 ) .304. - 595/ Email: JKa..z l968 w( ,nty_a • rr. Corn Contact Person for Building & Code Compliance: P C,fcadi 5 Cell Ph.: ( ig ) 3(,5 - g$C�7 Land Lind ( ) Email: erPrra.) h ,rou�sK_otrc>u.-)• Com PROJECT INFORMATION: TYPE: Commercial f Residential WORK CLASS: ✓_Single-Family Two-Family Multi-Family(#of ) Townhouse Business Office Retail Hotel/Motel Industrial/Warehouse Garage(#ofcars ) Other(describe ) STRUCTURE SQUARE FOOTAGE: GARAGE SQUARE FOOTAGE: 1slfloor: 19O9 41— is'floor: lit)-1 2nd floor: 5 E9 41— 2nd floor: 3rd floor: Total square feet: i- 01 Basement(habitable space): Total square feet: aL-}gs 4/- ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ J 2. Proposed use of the building: 5'�c 3. If Commercial or Industrial, indicate the name of the business: 4. Source of Heat (circle one): c� Oil Propane Solar Other: (Fireplaces need a separate Fuel Burning Appliances&Chimney Application, one per appliance) 5. Are there any structures not shown on the plot plan? YES NO Explain: 6. Are there any easements on the property? YES 7. SITE INFORMATION: �/� a. What is the dimensions or acreage of the parcel? • 5 b. Is this a corner lot? YES NO c. Will the grade be changed as a result of the construction? YES d. What is the water source? UREIC PRIVATE WELL e. Is the parcel on SEWER or PRIVATE SEPTI system? DECLARATION: I. lacknowledge that no construction shall commence priorto issuance of a valid building perm and work will be completed within a 12 month period. 2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approva I. 3. I certify that the application, plans and supporting materials are a t rue and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. I understand that Ikve are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: /PalaI�bc�c�c-c� i SIGNATURE: DATE: Cp I go 11 a Office Use Only � � FUEL BURNING APPLIANCE & Permit#: Qc--b ?j-b- 2p 15 _ ��� CHIMNEY APPLICATION Permit Fee: $ ::_ Invoice#: �f Queensbi: 742 Bay Road, Queensbury, NY 12804 P: 518-761-8256 www.que�n:;bury net Project Location: (15 4�)i Chma-j u;II Dr. Tax Map ID: 30S, 7- I - 591 Room of Install: f jn- � i�vom Planned Install Date: **ONE APPLICATI ON PER APPLIANCE** CONTACT INFORMATION: • Applicant: Name(s): kodt)rou)SIC i \fneS Mailing Address, C/S/Z: 7 to ' AeC ` lner e Ny /23 oce Cell Ph.: ( ) Land Line: (5/ ) '5(0 - /4/35 Email: C,,.k 6) 1nNaoccu.)5ki c joi(-). Corm • Primary Owner(s): Name(s): Mission ►-3�,.al�exS Mailing Address, C/S/Z: 796 u.reke cK Sc�nex►ec -c c IJy /a3O(o Cell Ph.: ( ) Land Line: ( 518 ) 31, - 14 35 Email: Qau_Q 6) \nociardwsk►lQuv, Corn • Installer/Builder: Name(s): drnt5 Mailing Address, C/S/Z: 7q(, rc\ec.K S-L icne-kacL, N V /a3C:to Cell Ph.: _( ) Land Line: (5/8 ) 351 - (4 3 5 Email: fA_c, ��c�LS ocoin.CDrn Contact Person for Building & Code Compliance: 'Pe-Q CDC cc,Ai Cell Ph.: ( ) 3(05 - 8.8D7 Land Line: _( ) Email: 1�r� CCV_ oue. Corn FUELIBURNING APPLIANCE INFORMATION: TYPE OF DEVICE: Stove Fireplace Insert Fireplace Fuel Fired Equipment(Garage Only,'B"clearance per IMC304.3) _Fireplace, factory built** ** Manufacturer's Name: 5u -r'i OC Model#: D rcT aD 5 SOURCE OF HEAT: • Wood Coal Pellet 120 CHIMNEYJNFORMATlON: Nil C,Q.5 cer-} Venk _Masonry: block brick stone Flue: tie steel size,in inches Material*: double-wall _ triple-wa If_insulated (*Manufacturer's ri a r-/-14 Model #: ADDITIONAL INFORMATION: 'f Two inspections are required. A rough-in inspection,prior to installation and a final inspection,after installation. 2 Manufacturer's installation manual must be available at the time of inspection. 3 Masonry fireplaces & chimneys require plans to be submitted. 4 Twenty-four (24) hour notification is required for nspections. Declaration:Construction/installation must conform to NYS Fire Prevention&Building Code and/or manufacturer requirements.The applicant or owner agrees to comply with all applicable laws,ordinances,regulations and all conditions that are part ofthese requirements and also will allow the inspector to enter the premises to perform the required inspections. , I have read and agree to the above: PRINT NAME: /Pa -\ -1-"\OaOrOu)S • SIGNATURE : DATE: Pfr01\9 Fuel Burning Appliance&Chimney Application SEPTIC DISPOSAL PERMIT APPLICATI ON Office Use Onl 742 Bay Road,Queensbury,NY 12504 P.518-761-5256 .. . ::: , .. Permt# - ZO I�1 -7 Tax Map ID#: 3Q$ a. 1 ' - Permit Fee:$ •Invoice#: Pro'ectLocation: q i id { 11 "Dry c._ Septic Variance? Yes - No Primary Owner(s) MIS5iOn 'but' Ic ex5 Mailing Address 796 Bux-ckcY. 36,Pne i-u crii, N`I 12 30(0 Phone & Email 51R . 354 . 1435 pn \ANcior009K.r c�('au . Corr Installer/Builder DC�Q(c u 5k► �Q �g C� Mailing Address --r q �ur�ec_K S� �c�r1P�eG� G N y I a 30U Phone & Email 51� • 35(0. 1 .-I-35 Qau.Q &Vloclort-)u.)51C: nLe• earn Engineer V (Lf) DU-5er) + C I eV veAdO Mailing Address 1 6q #-t r I Qv; lea !�� © �h fie' �v [ 'Q °+ t'1 u�P�fl t i Phone & Email 518- 79 d _ Y`-f7`-} QQ____.. Contact Person for Building&Code Gompl lanc :3Pc) l �rro,c ' Rhon : 51$• 'D(.5 •S837 RESIDENCE NFORMATION: Year Built # of bedrooms X gallons per bedroom = totaldaily flow Garbage Grinder Yes No 1980 or older Installed? {circle one) 1981 D91 Spa or Hot Tub Yes No Installed? {circle one) PARCEL NFORMATION: Topography Flat Rolling Steep Slope %Slope Soil Nature Sand Loam Clay _Other Groundwater At what depth? Bedrock/Impervious material At what depth? Domestic Water Supply Municipal _Well{if well,water supply from any septic system absorption is_ft.) Percolation Test Rate: per minute per inch(test to be completed by licensed engneer/arcl-tect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: Tank size gallons{min.size 1000 ga Ilons,add 250 gallons for each garbage cylinder or spa/hot tub System Absorption field with#2 stone Total length ft.;Each Trench ft. Seepage Pit with#3 stone 'How many: Size: Alternative System Bed or other type: HoldingTank System Total required capacity? stank size ;# of tanks NOTES:1.Alarm system&associated electrica!work must be inspected by a Town approved electrical inspection agency;2.We will no longer allow systems to be covered until such time as an as-built plan is received and approved. The installed system must match the septic layout on file-no exceptions. Declaration:Any permit or approval granted which is based upon or is granted in reliance upon any material representation orfailureto make a material fact or circumstance known by or on behalf of an applicant, shall be void.l have read the regulations and agree to abide bythese and all requirements oftheTown of Queensbury Sanitary Sewage Disposal Ordinanc e. PRINT NAME: 1 (N CO LU5 DATE: G\Oo\\, kr,[K__tn_ SIGNATURE: DATE: 0) N REScheck Software Version 4.6.5 �, 0 Compliance Certificate 1 CNIITr el O CI e-1 0 ECEUVEr c.) Project McKinleyl i o0 Energy Code: 2015 IECC JUN 24 2019L E o N Location: Glens Falls, New York ____ O 2 Construction Type: Single-family TOWN OF QUEENSBURY = c Project Type: New Construction BUll DING&CODES Cr) -x o to In N E cts Conditioned Floor Area: 2,498 ft2 ' 3 '0A Glazing Area 9% ti O U 3 Climate Zone: 6 (7635 HDD) ap 0 Permit Date: O O LO LA- Permit Number: CO I ) 0 Construction Site: Owner/Agent: Designer/Contractor: 95 Richmond Hill Drive Hodorowski Homes Northstar Home Design, LLC Queensbury, NY Compliance: Passes using UA trade-off --- Compliance: 2.3%Better Than Code Maximum UA: 394 Your UA: 385 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or U-Factor UA R-Value R-Value Perimeter Ceiling 1: Raised or Energy Truss 1,964 49.0 0.0 0.020 39 Wall 1: Wood Frame, 16" o.c. 3,459 21.0 0.0 0.057 177 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 269 0.300 81 Door 1: Solid 51 0.190 10 Door 2:Glass 40 0.300 12 Basement Wall 1: Solid Concrete or Masonry 1,752 19.0 5.0 0.037 65 Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Floor 1: All-Wood Joist/Truss:Over Unconditioned Space 43 30.0 0.0 0.033 1 Floor 2:All-Wood Joist/Truss:Over Outside Air 12 30.0 0.0 0.033 0 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name-Title Signature �rq0' Date Project Title: McKinley ` 24 �O* Report date: 05/21/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\95 Rik_ -fc ikdoR s Page 1 of 9 REScheck Software Version 4.6.5 r% I Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions &Req.ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ElDoes Not (PR1]1 energy code compliance for the [Not Observable v. building envelope.Thermal envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for DNot Observable [PR3)1 lighting and mechanical systems. ❑Not Applicable ki Systems serving multiple dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2)z on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Manual J or other methods Btu/hr Btu/hr approved by the code official. ElNot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: McKinley Report date: 05/21/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\95 Richmond Hill Drive.rck Page 2 of 9 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [F04)1 insulation R-value.Where interior R_ R- ❑Does Not table for values. d insulation is used,verification ❑Not Observable may need to occur during Insulation Inspection.Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [F05)1 insulation installed per ❑Does Not Ai) manufacturer's instructions. ❑Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies (F06)1 insulation depth of burial or ❑Does Not table for values. W distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO11)2 to protect exposed exterior ❑Does Not insulation and extends a 4� ❑Not Observable minimum of 6 in.below grade. ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [F012)2 controls installed. ODoes Not u, ['Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: McKinley Report date: 05/21/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\95 Richmond Hill Drive.rck Page 3 of 9 • Section Plans Verified Field Verified # Framing / Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]' [Not Observable ONot Applicable 402.1.1, Glazing U-factor(area weighted U- U ❑Complies See the Envelope Assemblies 402.3.1, average). ElDoes Not table for values. 402.3.3, ❑ 402.5 Not Observable [FR2]' ONot Applicable 303.1.3 U-factors of fenestration products ❑Complies [FR4]' are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. ONot Observable ONot Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]' installed per manufacturer's ❑Does Not instructions. ONot Observable ONot Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR2O]' is listed and labeled as meeting ElDoes Not 9 AAMA/WDMA/CSA 101/1.5.2/A440 [Not Observable or has infiltration rates per NFRC 400 that do not exceed code 'Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures DComplies [FR16]2 sealed at housing/interior finish ['Does Not and labeled to indicate- 2.0 cfm leakage at 75 Pa. ONot Observable ONot Applicable 403.3.1 Supply and return ducts in attics ❑Com lies [FR12]' insulated >= R-8 where duct is ElDoes Not >= 3 inches in diameter and >= R-6 where < 3 inches. Supply and ❑Not Observable return ducts in other portions of ONot Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ElDoes Not ONot Observable ONot Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105°F or chilled fluids ElDoes Not below 55°F are insulated to 3 ONot Observable ONot Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]' piping. ElDoes Not ONot Observable ONot Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >_R-3. ❑Does Not ❑Not Observable ONot Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ONot Applicable [1 High Impact(Tier 1) 2 [Medium Impact(Tier 2) 13 Low Impact(Tier 3) Project Title: McKinley Report date: 05/21/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\95 Richmond Hill Drive.rck Page 4 of 9 • Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: McKinley Report date: 05/21/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\95 Richmond Hill Drive.rck Page 5 of 9 Section 1 Plans Verified Field Verified # 1 Insulation Inspection Value Value Complies? Comments/Assumptions & Re..ID 303.1 All installed insulation is labeled ❑Complies [IN13)2 or the installed R-values ❑Does Not LI provided. ❑Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood 0Does Not table for values. [IN1]' ❑ Steel ❑ Steel ❑Not Observable e. ❑Not Applicable 303.2, Floor insulation installed per ❑Complies 402.2.7 manufacturer's instructions and ❑Does Not [IN2]' in substantial contact with the [Not Observable ,, underside of the subfloor, or floor framing cavity insulation is in ❑Not Applicable contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ['Not Observable [IN3]' exterior,the exterior insulation requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per DComplies [IN4]' manufacturer's instructions. DDoes Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: McKinley Report date: 05/21/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\95 Richmond Hill Drive.rck Page 6 of 9 • Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel ❑Not Observable 402.2.E[F1111 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [FI2]' Blown insulation marked every :Not Observable 300 ft2. ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [F122)2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [F13)' insulation zFt-value of the ❑Does Not adjacent assembly. ONot Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50= ACH 50= ❑Complies [FI17]' ach in Climate Zones 1-2,and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [FI4]' cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa.For rough-in ['Not Observable tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [FI27]' determine air leakage with ft2 ft2 ❑Does Not either:Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g.across the system including the manufacturer's air handler enclosure if installed at time of test.Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [FI2411 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [FI9]2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI10]2 on heat pumps. ODoes Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [FI11]2 systems have automatic or ❑Does Not accessible manual controls. ['Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: McKinley Report date: 05/21/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\95 Richmond Hill Drive.rck Page 7 of 9 I Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.1 All mechanical ventilation system ❑Complies [F125]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. ['Not Observable ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [F126]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [FI28]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply Not Observable pipe.Gravity and thermos- ❑Not Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies [F129]2 comply with IEEE 515.1 or UL ❑Does Not 515.Controls automatically adjust the energy input to the Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F130]2 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1049F. 403.5.4 Drain water heat recovery units ❑Complies [FI31)2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for ONot Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units<2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [FI6]' fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [FI23]3 no continuous pilot light. ElDoes Not +2; ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: McKinley Report date: 05/21/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\95 Richmond Hill Drive.rck Page 8 of 9 • • Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Re .ID 401.3 Compliance certificate posted. ❑Complies [FI7]2 ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI18J3 mechanical and water heating ❑Does Not systems have been provided. ['Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 1 Project Title: McKinley Report date: 05/21/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\95 Richmond Hill Drive.rck Page 9 of 9 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 24.00 Floor 30.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): Glass& Door Rating U-Factor SHGC Window 0.30 Door 0.19 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments cEllvEr JUN 24 2019-1 [0 95 Richmond Hills Dr TOWN OF QUEEN HVAC Load Calculations BUILDING& CQDg SRY for Hodorowski (MIR* "I RHVA RESIDENTIAL, HVAC LOADS 308.7-1-59 RC-0433-2019 Prepared By: Hodorowski Homes 95 Richmond Hill Dr, Lot 12 Nick Abrunza Appolo Heating SFD w/gas FP 2498 s.f., Gar. 437 s.f. 868 Burdeck St Schenectady Ny 12306 Monday,June 3,2019 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 95 Richmond Hills Dr Schenectady,NY 12306 Page 2 Project Report General Project Information Project Title: 95 Richmond Hills Dr Designed By: Hodorowski Project Date: Monday, June 3, 2019 Client Name: Hodorowski Company Name: Appolo Heating Company Representative: Nick Abrunza Company Address: 868 Burdeck St Company City: Schenectady Ny 12306 Design Data Reference City: Schenectady, New York Building Orientation: Front door faces North Daily Temperature Range: Medium Latitude: 42 Degrees Elevation: 378 ft. Altitude Factor: 0.986 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel Hum Rel.Hum Dry Bulb Difference Winter: 1 0.31 n/a n/a 70 n/a Summer: 87 72 49% 50% 75 30 Check Figures Total Building Supply CFM: 1,329 CFM Per Square ft.: 0.317 Square ft. of Room Area: 4,194 Square ft. Per Ton: 1,398 Volume (ft3): 39,388 Building Loads Total Heating Required Including Ventilation Air: 78,188 Btuh 78.188 MBH Total Sensible Gain: 30,962 Btuh 86 % Total Latent Gain: 5,031 Btuh 14 % Total Cooling Required Including Ventilation Air: 35,994 Btuh 3.00 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\95 Richmond Hills Dr.rh9 Monday, June 3, 2019, 9:46 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 95 Richmond Hills Dr Schenectady, NY 12306 Page 3 Miscellaneous Report System 1 Outdoor Outdoor Outdoor Indoor Indoor Grains Input Data Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 1 0.31 80% n/a 70 n/a Summer: 87 72 49% 50% 75 29.96 Duct Sizing Inputs Main Trunk Runouta Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 0 ft./min 0 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration Specified: 0.370 AC/hr 0.190 AC/hr 243 CFM 125 CFM Infiltration Actual: 0.274 AC/hr 0.000 AC/hr Above Grade Volume: X 39,388 Cu.ft. X 39,388 Cu.ft. 10,788 Cu.ft./hr 0 Cu.ft./hr X 0.0167 X 0 0167 Total Building Infiltration: 180 CFM 0 CFM Total Building Ventilation: 163 CFM 163 CFM ---System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 13.02 = (1.10 X 0.986 X 12.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 20.09 = (0.68 X 0.986 X 29.96 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 74.87 = (1.10 X 0.986 X 69.00 Winter Temp. Difference) Winter Infiltration Specified: 0.370 AC/hr(243 CFM), Construction: Average Summer Infiltration Specified: 0.190 AC/hr(125 CFM), Construction: Average C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\95 Richmond Hills Dr.rh9 Monday, June 3, 2019, 9:46 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. • 95 Richmond Hills Dr Schenectady,NY 12306 Page 4 Load Preview Report Nett ft. Sen Lat Net Sent Ht s CI s Act Duct Scope Tort /Tor, Area Gain Gain Gain Los i CFM CFM CFM Size Building 3.00 1,398 4,194 30,962 5,031 35,994 78,188 868 1,329 1,329 System 1 3.00 1,398 4,194 30,962 5,031 35,994 78,188 868 1,329 1,329 12x1£ 1 Ventilation 2,126 3,281 5,408 12,226 Zone 1 4,194 28,836 1,750 30,586 65,962 868 1,329 1,329 12x1£ 1-Basement 1,910 2,393 0 2,393 17,453 230 110 110 2--5 2-Master Suite 255 3,169 700 3,869 5,700 75 146 146 2--6 3-WIC 1 24 521 0 521 765 10 24 24 1--4 4-W1C 2 48 518 0 518 433 6 24 24 1--4 5-Master Bath 137 1,599 0 1,599 3,198 42 74 74 1-6 6-Two Story Foyer 137 1,959 0 1,959 4,109 54 90 90 1-6 7-Family 350 2,471 0 2,471 6,405 84 114 114 2-5 8-Dining 195 1,828 0 1,828 4,023 53 84 84 1-6 9-Nook 144 1,430 0 1,430 3,605 47 66 66 1-6 10-Kitchen 144 916 0 916 1,512 20 42 42 1-5 11-Guest 196 2,224 350 2,574 4,328 57 102 102 1-7 12-Bath 1 60 867 0 867 990 13 40 40 1-5 13-Laundry 39 1,063 0 1,063 1,324 17 49 49 1-5 14-Mud Room 56 939 0 939 1,359 18 43 43 1-5 15-Bedroom 3 156 2,329 350 2,679 3,827 50 107 107 1--7 16-Hall 100 636 0 636 903 12 29 29 1--4 17-Bath 2 55 915 0 915 1,504 20 42 42 1--5 18-W1C 3 25 397 0 397 224 3 18 18 1--4 19-Bedroom 2 164 2,660 350 3,010 4,300 57 123 123 2--5 C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\95 Richmond Hills Dr.rh9 Monday, June 3, 2019, 9:46 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. Ilk 95 Richmond Hills Dr Schenectady, NY 12306 _ Page 5 Duct Size Preview Room or Source Minimum Maximum Rough Desigr SP Duct Duct Htg Clg Act. Duct Duct Name Velocity Velocit, Factor L/10[ Loss Velocit; Length Flow Flow Flow Size System 1 Supply Runouts Zone 1 J 1-Basement Built-In 0 750 0.01 0.1 404.3 2301-0 110 2--5 2-Master Suite Built-In 0 750 0.01 0.1 371.8 75 t 146 146 2--6 3-WIC 1 Built-In 0 750 0.01 0.1 275.3 10P 24 24 1-4 4-WIC 2 Built-In 0 750 0.01 0.1 273.7 6 24 24 1-4 5-Master Bath Built-In 0 750 0.01 0.1 375.2 421112 74 74 1-6 6-Two Story Foyer Built-In 0 750 0.01 0.1 459.8 54 90 90 1-6 7-Family Built-In 0 750 0.01 0.1 417.6 84 114 114 2-5 8-Dining Built-In 0 750 0.01 0.1 429 53 84 84 1-6 9-Nook Built-In 0 750 0.01 0.1 335.7 47 66 66 1-6 10-Kitchen Built-In 0 750 0.01 0.1 309.6 20 42 42 1-5 11-Guest Built-In 0 750 0.01 0.1 383.5 57 102 102 1-7 12-Bath 1 Built-In 0 750 0.01 0.1 293.1 13 40 40 1--5 13-Laundry Built-In 0 750 0.01 0.1 359.3 17 49 49 1--5 14-Mud Room Built-In 0 750 0.01 0.1 317.4 18 43 43 1-5 15-Bedroom 3 Built-In 0 750 0.01 0.1 401.6 50 107 107 1-7 16-Hall Built-In 0 750 0.01 0.1 336 12 29 29 1-4 17-Bath 2 Built-In 0 750 0.01 0.1 309.3 20 42 42 1-5 18-WIC 3 Built-In 0 750 0.01 0.1 209.7 3 18 18 1-4 19-Bedroom 2 Built-In 0 750 0.01 0.1 449.6 57 123 123 2-5 Other Ducts in System 1 Supply Main Trunk Built-In 0 900 0.003 0.1 839.2 868 1,329 1,329 12x1f Summary System 1 Heating Flow: 868 Cooling Flow: 1329 C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\95 Richmond Hills Dr.rh9 Monday, June 3, 2019, 9:46 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 1110 95 Richmond Hills Dr Schenectady, NY 12306 Page 6 Total Building Summary Loads Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain Plygem Pro: Glazing-Plygem Pro, U-value 0.33, SHGC 266.4 6,065 0 3,990 3,990 0.28 Front Door: Door-Front Door Generic, U-value 0.19 20.4 267 0 89 89 Pella Slider: Door-Pella Slider, U-value 0.3 40.8 845 0 282 282 Fire Rated: Door-Fire Door Generic, U-value 0.28 20.4 394 0 131 131 12E-0bm: Wall-Frame, R-19 insulation in 2 x 6 stud 1384 9,837 0 1,199 1,199 cavity, no board insulation, brick finish, metal studs, U- value 0.103 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, 2578.5 11,565 0 2,062 2,062 no board insulation, siding finish, wood studs, U-value 0.065 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic 1850.4 2,553 0 1,740 1,740 Floor(also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation, U-value 0.02 21A-24: Floor-Basement, Concrete slab, any thickness, 2 1909.7 3,294 0 0 0 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 24'wide, U-value 0.025 19A-Ocp: Floor-Over enclosed crawl space, No insulation 1937.9 14,818 0 2,576 2,576 on exposed walls, sealed or vented space, passive, no floor insulation, carpet or hardwood, U-value 0.295 19A-0tp: Floor-Over enclosed crawl space, No insulation 346.2 2,861 0 497 497 on exposed walls, sealed or vented space, passive, no floor insulation, tileor vinyl, U-value 0.368 __ Subtotals for structure: 52,499 0 12,566 12,566 People: 5 1,750 2,250 4,000 Equipment: 0 0 0 Lighting: 4110 14,015 14,015 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 180, Summer CFM: 0 13,463 0 0 0 Ventilation: Winter CFM: 163, Summer CFM: 163 12,226 3,281 2,126 5,408 AED Excursion: 0 0 5 5 Total Building Load Totals: 78,188 5,031 30,962 35,994 Check Figures Total Building Supply CFM: 1,329 CFM Per Square ft.: 0.317 Square ft. of Room Area: 4,194 Square ft. Per Ton: 1,398 Volume (ft3): 39,388 Building Loads Total Heating Required Including Ventilation Air: 78,188 Btuh 78.188 MBH Total Sensible Gain: 30,962 Btuh 86 Total Latent Gain: 5,031 Btuh 14 % Total Cooling Required Including Ventilation Air: 35,994 Btuh 3.00 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\95 Richmond Hills Dr.rh9 Monday, June 3, 2019, 9:46 AM Rhvac-Residential&Light Commercial HVAC Loads i Elite Software Development,Inc. Appolo Heating Inc. Ii 95 Richmond Hills Dr Schenectady, NY 12306 Page 27 System 1 Room Load Summary Htg Min Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct Sens Lat Clg Sys No Name SF Btuh _ CFM _. Size Vel Btuh Btuh CFM CFM ---Zone 1--- 1 Basement 1,910 17,453 230 2-5 404 2,393 0 110 110 2 Master Suite 255 5,700 75 2-6 372 3,169 700 146 146 3 WIC 1 24 765 10 1-4 275 521 0 24 24 4 WIC 2 48 433 6 1-4 274 518 0 24 24 5 Master Bath 137 3,198 42 1-6 375 1,599 0 74 74 6 Two Story Foyer 137 4,109 54 1-6 460 1,959 0 90 90 7 Family 350 6,405 84 2-5 418 2,471 0 114 114 8 Dining 195 4,023 53 1-6 429 1,828 0 84 84 9 Nook 144 3,605 47 1-6 336 1,430 0 66 66 10 Kitchen 144 1,512 20 1-5 310 916 0 42 42 11 Guest 196 4,328 57 1-7 383 2,224 350 102 102 12 Bath 1 60 990 13 1-5 293 867 0 40 40 13 Laundry 39 1,324 17 1-5 359 1,063 0 49 49 14 Mud Room 56 1,359 18 1-5 317 939 0 43 43 15 Bedroom 3 156 3,827 50 1-7 402 2,329 350 107 107 16 Hall 100 903 12 1-4 336 636 0 29 29 17 Bath 2 55 1,504 20 1-5 309 915 0 42 42 18 WIC 3 25 224 3 1-4 210 397 0 18 18 19 Bedroom 2 1.64 4,300 57 2-5 450 2,660 350 123 123 Ventilation 12,226 2,126 3,281 System 1 total 4,194 78,188 868 30,962 5,031 1,329 1 329__ System 1 Main Trunk Size: 12x19 in. Velocity: 839 ft./min Loss per 100 ft.: 0.095 in.wg Cooling System Summary Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 3.00 86%/ 14% 30,962 5,031 35,994 Actual: 3.46 75%/25% 31,125 10,375 41,500 Equipment Data Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: ML195UH090XP48C-* 13ACXN042-230-** Indoor Model: C35-48C+TDR+TXV Brand: MERIT 90 MERIT 13ACX SERIES Description: Natural Gas or Propane Furnace Efficiency: 95 AFUE 14 SEER Sound: 0 0 Capacity: 85,000 Btuh 41,500 Btuh Sensible Capacity: n/a 31,125 Btuh Latent Capacity: n/a 10,375 Btuh AHRI Reference No.: n/a 8269534 f C:1Users\nicka\Documents\Elite Software\Rhvac 9 Projects195 Richmond Hills Dr.rh9 Monday, June 3, 2019, 9:46 AM ,F y z y r, I ' :sr: 74 e PS sumporE. T., Water Powered Back-Up Pump • Protects Model SJ10 Shown basement during t��114� power outages! Requires no electricity r •Accepts 20PSI up to 100PSI inlet supply pressure** • • . • Fully automatic ;; • High-output flow rates •Compact design • Fully-assembled _ �6 � • 1-1/2" Discharge S;-lARK39TE° YEHR •Works off municipal water supply* Fitting WFIRR IIITY • 3/4" NPT water inlet connection Ittf ' • UPC approved (IAPMO PS 119-2005) •SHARKBITE inlet connection accepts pex,copper or CTS CPVC 3/4"line i ' _ aiatc.-ierit Uesigi reinowr-- 'The SJ10 requires an uninterrupted N water source to operate.If you have a ii;, well pump,the SJ10 will not operate `3;` , (t. —r�\ during power outages. :`r SJ10 pumping performance varies with inlet 1 water source pressure and pumping head. See complete specifications and performance chart for expected flow rates. SHARKBITE®is a registered trademark of the CASH ACME Co. a _ , NEW! .a, ca a3 -s.,., p,.t.,Tkry A. O if Audible and visual alarm warns you when your water-powered �® I r., back-up pump is activated. 71,. 120V with 9V battery backup. S urn P J'ET°Water Powered Back-Up Sump Pump Performance Chart: I .1.. I • ■ L l . • . . ,, • , ..r: _ :..___ : , : , , . , • „ :, , ._.,... ...„ . . • ___ • . _....... ___. , • , : : ........ . .L.„__ • . _ . ______ _..... ... . , , , , . . . __+_ ..____ ____F i INIGT PRG;tI;RF CSI 0. :_: t ......-..-..-_. .._I� Is- r. i Pew(GP'AI Water pressure valve Sump Water Removal At Various Heads at inlet with valve open and water flowing (Static Head in 1-1/2"Pipe or Larger) Lift 4 ft. 1.21 m 8ft. 2.4M 12ft. 3.6 M 15 ft. 4.5 M PSI KPA GPM GPH M'"' GPM GPH M'"" GPM GPH M'"" GPM GPH M'' 20. . 138 11.0 _ 660 2.5 5.8 348 1.3 - - - - - - 30 207 12.8 765 2.9 9 540 2.0 5.5 330 . 1.2 - - - 40 276 15.4 924 3.5 12.5 750 2.8 9.3 558 2.1 7.2 432 1.6 50 345 17.2 1032 3.9 14.5 870 3.3 12 720 2.7 10 600 2.3 60 414 19.8 1185 4.5 17 1020 3.9 15.2 912 3.5 13.5 810 3.1 Features: Typical Installation Models Adjustable stainless hose clamp for Diagram: SJ10 Standard water-powered easy mounting backup pump(no alarm) Removes 2 gallons of water for each I { SJ10A Water-powered pump 1 gallon used.(based on 5' lift) ---Li- with alarm p g Fullyassembled,compact design _ �- _ , �•� t- _ �. ADC-1 Automatic voice dialer Built-in screen with removable foot valve -= ' ;..,� j' (Optional,sold separately) Constructed of durable PVC D , %flfenSlO/TS ADC-1 Auto Dialer sequentially dials Major Height:21.6", Major Width: 5.1", any combination of four telephones,cell Weight 3.5 lbs. 1 I i.- ,,• phones or pagers and delivers up to a ( ; 16 second recorded message-notifying .�- � �'#i _ 9 Y 9 Construction:PVC A ., , -� you if your water pump is activated.Unit Maximum Fluid Temperature 130 Degrees F. i •y" --k ties directly into the auxiliary contacts on the SJ10A alarm. Inlet Connection: - . •Operating Voltage:9-12 VDC 3/4"SHARKBITE°fitting •Dimensions:6"x 4"x 1.5" Discharge Size: 1-1/2" _ - -- •Mounting:Mounts flat on wall •Record your own message Built-in check valve at water inlet •Ability to program a pause and pound(#) Additional backflow protection is required. tone in dialing sequence. Check with local plumbing codes prior lifel to installation. I I I I Call your Call your Call your Cat your Important:Minimum recommended pit diameter is • cell phone plumbing family neighbor 18".The SJ10 works in conjunction with your main contractor sump pump.Make sure you have adequate pit size to properly install the SJ10 without float interference. Sold Separately Liberty Pumps• 7000 Apple Tree Avenue•Bergen,New York 14416•Phone 800-543-2550 Fax(585)494-1839 www.libertypumps.com Copyright CO Liberty Pumps,Inc.2008 All rights reserved. LLIT4400-R9/08 •ii✓ - > ,s ' f ..+. ..i,5, � id .' '-Z't�i�` tx,�, i�jev �'.44:•„ `L, ` ( �•T - .�:, y"F {r �. > ,,�•+-> T f,2w j :.r.i q 40- 0,- SUPERIOR c0P11.AN?'��0 TUFF-N-DRIJJ HANG —2-11<541A soil/ 7 ra � Y? STRENGTH MAXIMUM PERFORMANCE The superior hang strength of TUFF-N-DRI°H8 delivers Ia consistent thickness for maximum waterproofing performance when it cures to 40 mils.Other waterproofing products slide down the wall and pool at the footer, leaving • basement walls vulnerable to leaks and seepage. •,•,,_ ; TUFF-N-DRI is performance-engineered to hang in place on the wall, eliminating product waste and providing exceptional waterproofing protection. Only TUFF-N -DRI H8: 17/11 • holds back up to 8 feet of water under hydrostatic pressure • is specifically formulated to span concrete settling R cracks, sealing against water leaks • offers up to a 30 year performance warranty 1~�/Barrier Solutions. • stays where it's sprayed for maximum protection r'ti ' 1 '1"�,.'}y`�J • .y e- M' •-F1 ': - ^._'„h.. • r Y�•'�� t2C� Lam 'e'(, Ys3A 'rrj,.��yi;i;�Jr , 74`.�` r �;I�.eft't�a�� i>�v?s�.-J-.r•�Ci�;��w� 't '�`r��•F.4 � �•t• '3T l.')•.-- -___��41 - �•1 A • . • .• ..• . ,• . . ,_, AN7,4, ‘ A History of i. . ._..,.......,._. . L© 4Cd , � PERFORMANCE ©- TUFF-N-DRI For well over 30 years,Tremco Barrier 0��� Solutions has helped builders across �� � North America offer drier, more BASB comfortable homes by manufacturing the industry's best foundation waterproofing system. 011.1.1. ,.iiiiiimi:org:go, Membrane Properties Resistance to Hydrostatic Head Results:8'of water Method: ASTM 0-5385 TUFF-N-DRI offers the most reliable Type Polymer-enhanced asphalt liquid-applied membrane system in the industry to control Color Black basement moisture: Solids 64%±3%(percent by weight) Density 8.2±.15 lbs/gal \O TUFF-N-DRI H8 membrane is Applicationspray-applied to a consistent Airless spray -fhickness-oL4 cured ' Application Temperature Minimum 20°F Application Thickness 60 mils(wet)' • : ' • RM-N-DRI'Foundation Bard Typical Cure Time 16-24 hrs(under normal conditions) or protects -DRI Barrier inBpe, protects �embrbne,assists Crack Bridging Ability Results: Posses Method: ICC-ES AC29, drainage,-arTd instbfates Sec 3.1 )2ase-m-ent walls to red ce interior condensation. Water Vapor Permeance Results: <1 perm for 40-mil Method: ASTM E-96 dry coating(grains/sf/hr) Wet Method Elongation Results: >1800% Method: ASTM D-412 © Sh with optionaJ,ei'ainStar Strip Drai a cost-effective Adhesion to Concrete Results: Exceeds • Method: ASTM C-836 alternative.t drain tile and Resistance to Degradation In Soil Results: Good Method: ASTM E-154 gl Mold Growth and Bacterial Attack Results: No degradation Method: ASTM D-3273, ASTM D-3274 ' Measured in-place with ASTM D-4414 notch film gauge.Wet 60 mils on notch film gauge. Membrane cures[dries)to 40mils. For more details on TUFF-N-DRI H8, contact your Board Properties' local Barrier Solutions Contractor, WARM-NI-DRI TUFF-N-DRI call 800-DRY-BSMT or Type Foundation Board Barrier Board visit TUFF-N-DRI.com Board Size 4'x4' 4'x8' 4'x4' 4'x8' Board Thickness 334" 13/4o" 2'e 31/2" 3/4" 13 o'' 21B" 2-e" Drainage Abilityr.m.,,ree.rree >70 >110 >210 >290 >50 >80 >130 >160 Thermal Resistance R-3 R-5 R-10 R-15 R-3` R-5' R-9' R-10' • • 'Meets requirements for ASTM C 612. 'Hydrauhc gradient of 1.0.Drainage rates with 10%hoard compression.Al 65%compression,foundation board has the drainage copabirlies of coarse sand. ' As manufactured resistance values IR-value). TRE117CO gi 'Barrier Solutions. Your Local Barrier Solutions 'For complete warranty details.visit TUFF-N•DRI.com Contractor 02018,Tremco Bonier Solutions.Inc.TUFF-N-DRI'and OroinStar are registered trademarks of Tremco Sorrier Solutions.Inc. Rev.I 1/18 WARM-N-DRI'is a registered trademark of Owens Coming. 18S-0735 > A (' •.5,. •S,,1c'1 1'..1A.rfr.7 IF.�Q ` .:',i�r.' 7 r:.:w. :�. - T • ° e.•. ''. { o i . } _ 11. silt ram...�y t , 1, ^fps �..,i.�e,.ws�c ,+..�.�-�•z.3..r_�.rwaxaw w.urc.-�snaxs.w pN ' ,.. i t. - i I G ! t+- i� .. —.:wc :'1 L. !`y ,... j 5S i y.RM` i ,° }: t4: , I 1, PFt L . L �; I rl s1' 11 - .'._.:.1.o'c �` - • 'tip w1 t� ire r , C]CC3x 1 0- .—.m ,-t. i . Olf CD r I t C"7, C SI u{C � �' 2-n Z Alit/ : C( .a ml nZ `v p Cn 0C IA u • '3'S L£v 'ae0 'Ts 86tZ dJ se /M OJS ZZ 1o1 `aa II!H puowy3!H 56 sawoH !)IsMoiopoH 6TOZ-££t7O 3H 65-T-L-80£ � m ° O Q1 '0 [ Ufll CI Q c is • j • �j; .I CA 1 . f • D m a to (+ a 2 n; s c ,+ m I CD p a s 7.. ,w m (D t m " 5`� c p • o - z i = a p 3 m a N O P- rt o o d R CD. . 7 o a a n O cD O -, tD r. a Ln r 03 •, x to v .� Q 3t3' mUijI 7 wn - O- a) m. _ to _ - .- N 7.a ° ik S Er r Q cF tit 7 A g 0 Cl 37 a a c p 00 O 1D .r-'-« - ,, cy- , wa Ii s n a C N O 0 5 < Q 'o m- ,_�,. N nm CD n CD gym ° > ; $ Qom o O , a0003a C3cn� a m a qcamW yf 3 o m Nc° co S. a 2 . pC• A. . -, 41 • ,a g- ° d °o ° d o a o, o to o c m n a y 46 m • (D a. co C 7 o C S. CO 3 .0 n 3 0 Zs- 3 3 o O g m c m 3 $ (u�. ,., O cp n rt p s, n 3 aN E. (p 1° N n t O 0 0 �+ O m N 3 •o m 7 in c* m D a Co {s' F-+ r o 2 o c °a° s 8 o m o o- O � � �cQ O 3 m 3 3 m 3 S -p f a r+ w `G o vi7i Co. y °a.co A °' � ° o m v 3 O a 3, o m c (D N ° o 2• n c 'CS O c • i Su o Ti m 7. NcD <. ; rt m 7 O C °ni w 3 a m S m N N n�i N 3 3 CD a c c > > x c a d m - 3 - o m a m fl O p: m `, m g' (D 3 3 C O o a, c O 3 < cD ,• a s t y m j Q .z Q rt v y c, Q. 0 1 O 3 y 0 o p n '' al o O io a- 1 4 LVCS INDOOR AIRQUALITY s0t. uTrisNs , + HEALTHY CLIMATE® Lennox Ventilation Control System Bulletin No.210406 April 2016 PRODUCT SPECIFICATIONS Supersedes May2013 rp • v r rill• - � ?F .� O>, u .11,t1� VebRz Fyryy N D191N1 Vipl�all C ntI.N OVERVIEW Whole-house ventilation for improved indoor air quality and comfort. Automatic monitoring of outdoor temperature and indoor .; relative humidity. ; Compatible with any forced air HVAC system. Digital Ventilation Controller is installed in the return NOTE- These modes below utilize the Outdoor duct of a forced air HVAC system. Temperature Sensor(furnished)to increase comfort and Meets ASHRAE 62.2-2010 Standard for Ventilation. reduce energy costs by preventing extreme hot, cold or Working in conjunction with the supplied damper,the humid air from being used to ventilate the house. Digital Ventilation Controller determines when and The Digital Ventilation Controller prevents ventilation g humidity indoor relative operation how long to ventilate.This is done through continuous o p y is above 55% monitoring of indoor relative humidity, outdoor and the outside temperature is above 50°F to prevent temperature,and user-adjusted timer settings. excess indoor humidity levels. Indoor relative humidity is monitored to help prevent Mode B: Timer Controlled Ventilation(with high humidity conditions inside the house.The Digital temperature and humidity limits) Ventilation Controller will not open the damper to the Uses outdoor temperature, indoor humidity, and user- outside air if there is a chance of raising the humidity adjustable timer settings to determine when ventilation inside the house to high levels. is required. In very cold climates, balanced ventilation is Allows normal ventilation operation down to 20°F recommended. LVCS can be used with an exhaust fan outdoor temperature without heating and down to 0°F to provide balanced ventilation. Per ASHRAE 62.2- with heating.Also prevents ventilation operation if 2010,very cold climates are those that have more than outdoor air temperature is above 100°F or below 0°F. 900 annual heating degree-days based on 65°F day. Mode C: Timer Controlled Ventilation for Cold WARRANTY Climates(with temperature and humidity limits) All Covered Components-Five year limited warranty Uses outdoor temperature, indoor humidity, and user- in residential applications. adjustable timer settings to determine when ventilation Refer to Lennox Equipment Limited Warranty certificate is required. included with unit for specific details. Allows normal ventilation operation down to 0°F outdoor temperature.Also prevents ventilation MODE SELECTION operation if outdoor air temperature is above 100°F or The Digital Ventilation Controller operates in one of four below 0°F. available modes. Mode D: Timer Controlled Ventilation for Warm Modes are selected by the installer inside the Digital Climates(with temperature and humidity limits) Ventilation Controller by means of a 4-way rotary DIP Uses outdoor temperature, indoor humidity, and user- switch. adjustable timer settings to determine when ventilation Mode A: Timer Controlled Ventilation(no is required. temperature or humidity limits) Allows normal ventilation operation down to 40°F Used for time-based ventilating regardless of outdoor temperature without heating and down to 0°F temperature or humidity. with heating.Also prevents ventilation operation if This mode may be required by local codes. outdoor air temperature is above 90°F or below 0°F. FEATURES COMPONENTS Controller Settings .Kit includes Digital Ventilation Controller, motorized Ventilation Time-Set by the knob on front exterior of damper,outdoor temperature sensor,and 24 VAC controller. Unlimited settings from Off to 60 minutes. transformer. Test-"TEST"setting is all the way clockwise on the Ventilation Time knob.This setting is used to check the Controller Controller at installation. In Test mode the Ventilation Input:22 to 30 VAC,2.0VA nominal Controller activates the HVAC blower and opens the Damper Output: 18 to 30 VAC, 10VA nominal damper for one minute or until the knob is taken off the Temperature accuracy:±5°F "Test"setting,whichever occurs first.After the minute Relative Humidity Accuracy:±5%RH has passed,the Ventilation Controller will not work until the knob is placed in the"off'position for several Ventilation Time:0-60 minutes(selectable) seconds then setting it to the desired ventilation time. Must be installed at least 6 inches up-stream from fresh air intake duct, humidifier or humidifier bypass duct Outdoor Temperature Sensor work. Senses outdoor temperature and reports to the Indoor Humidity is measured in the return duct with a controller. sensor built into the Controller. Sensor should be installed in the fresh air intake hood NOTE-This system may not be installed with a power- (field provided)or in the intake duct, no more than three feet from the outside wall. robbing thermostat. If the outdoor temperature is above 100°F or below 0°F, the damper will not open. Damper 6 in.diameter, 10-3/4 in. length Normally-closed, power-open 24 VAC/0.31 amp/Two-wire Transformer 120V primary, 24 VAC secondary 10VA output VENTILATION TIME SETTINGS VENTILATION TIME SETTING-MINUTES PER HOUR Size of House- Number of Bedrooms sq.ft. 2 3 4 5 1000-1500 20 min. 25 min. 30 min. 35 min. The time settings determine when and how long 1501-2000 25 min. 30 min. 30 min. 35 min. to ventilate.The following chart can be used to determine the time settings.For a more precise way 2001-2500 25 min. 30 min. 35 min. 40 min. of determining ventilation time,see the Ventilation 2501-3000 30 min. 35 min. 40 min. 40 min. Worksheet on the following page. 3001-3500 30 min. 35 min. 40 min. 45 min. NOTES-Table based on ASHRAE 62.2-2010 Based on 20 ft.flexible fresh air duct with 0.15 in.w.c.static pressure. A longer duct or lower return static pressure will increase the ventilation time required. Local codes may affect the time settings. LVCS Ventilation Control System//Page 2 I VENTILATION WORKSHEET Quality of air is regulated by preventing ventilation when CFM required is based on ASHRAE Ventilation the outside air is too hot, too cold, or could raise the Standard,the area and occupancy of the house. relative humidity in the home above 55%. CFM delivered is based on length of fresh air intake Quantity of air is regulated by setting the Ventilation duct, static pressure of the return, and the type of duct. Time. The following three steps will help assure proper adjustment of the controller. Step 1 -Determine Ventilation Air Required (per ASFIRAE Standard 62.2-2010) • Find square footage of house on - •;, J I r L 1 J • { i horizontal axis. I Example.A 2300 egrt.3 bedroom . 1 , I ' I .1 1 2 FM Draw a vertical line up from the 'Co home would requlte53C ------1 j -1 1.. I' _ r- bottom to the point that intersects the I i -� I 1 5* °°!"` line for the number of bedrooms in 1 -i •J 1 --I---1 I I --1 • e the house. �C • "I*6` From the point where the house size "r : .-.-= i ,-1--4 and bedroom lines intersect, draw s ao ; ; ' ;,__ ' '_''"y_ , !_ _Imo_ T-- a horizontal line to the left(vertical) '-. , _. f I I . .... • axis to determine how much i + I I ventilation air(CFM)is required. 40 :— I ! J ? _! _i 1— i -}— NOTE-ASHRAE62.2-2010callsfor -1 • ; . - f • ,-j 1 '- - 1.� I • _ 1 CFM of ventilation per 100 square -� I • i ]t" I J 1 i feet of house plus 7.5 CFM per i 1 -I ; i bedroom plus an additional 7,5 CFM. - ' . I .• .. .1, . . lr' .-r- -._. 1 1000 1500 2000 2500 3000 3500 4000 4500 5000 House 5120(sq.(I.) Step 2 -Determine How Much Ventilation Air the System will Deliver Ventilation Air the System Will Deliver-CFM Using the table, 'Static Pressure of Return Duct-in.w.c. determine how much Length of 6 in. CFM can be brought diameter 0.05 0.10 0.15 0.20 0.25 0.30 into the house based fresh air intake duct Flex Rigid Flex Rigid Flex Rigid Flex Rigid Flex Rigid Flex Rigid on the length and type 10 ft. 60 65 85 90 105 110 120 125 135 140 150 160 of fresh air duct used 20 ft. 55 60 80 85 100 105 115 120 130 135 140 150 as well as the static 30 ft. 50 55 75 80 95 100 110 115 125 130 130 140 pressure in the return air duct. 'For the static pressure shown,the flex duct is laid loose with two wide 90°bends and the damper fully open.For rigid pipe the values are based on two 90°elbows and the damper fully open.For both types of dud the air intake is terminated with a metal vent hood with a birdscreen.Adjust airflow up or down for variations,inducting elbows or bends,or if the length of duct isn't listed. Step 3 -Ventilation Controller Setting 1 Example 1153 CFM is required and 110 I I F CFM Is delivered set ventilation I. +. _i__ ..___ ._ controller knob to 30 minutes per hr. .._..! —�- --_ ....-.. ....j._�_.— Using the value obtained in Step 1, ,50•_ - 1 - _ , 1 locate the CFM required on the left I I 1 I . (vertical) axis and draw a horizontal -.• r _.1 . L l 1'..0 1 ? i .. I- _j . r . I . line to the end of the chart. 200�__�,_-_ _J_ �_ ":::',.r:: ,• ; Using the value obtained in Step :_ 2, locate the CFM Delivered on the I J 1 .IM --L-... ...- t.• °Sri • .•.. �0F i horizontal axis and draw a vertical Ise . -- -- line up from the bottom to a point g �-__ _ . _ i_._ _.- a :_.�__;__ beyond the vertical CFM required I s0m r f line. mo -- - .. l �_ ._ The point where the two lines �' � • I I • ! ---+ -- -"• 1... .._._.... . -.-_;. . . ...I. intersect indicates where the _ „�, �,1 �, _1 _ Ventilation Time should be set. It __ IPijp.iPiir..- I I• lop+'" t may be necessary to estimate the precise setting if the intersection I _i-. _ _ . point falls between two lines. 0 I-- — _:..-_y-�_,__ -I--- i` _-, -- —I . 1-----IL.._.: 0 50 100 150 200 250 300 CFrt Delivered LVCS Ventilation Control System I Page 3 I REVISIONS Sections Description of Change Features Damper actuator updated. Visit us at www.lennox.com For the latest technical Information,www.lennoxdavenetcorn Contact us at 1-800-4-LENNOX NOTE-Due to Lennox'ongoing commitment to quality,Specifications,Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation,adjustment,alteration,service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 02016 Lennox Industries,Inc. HODOROWSKI f1 0 M S BUILDING ON TRADITION 1 II Town of Queensbury J�N 2 4 JJ 1� 29 104 uilding Department - CODE Gf BUILDING g, Re: Barringer Heights Subdivision To Whom It May Concern, With any new homes in the Barringer Heights Subdivision, Hodorowski Homes will set the bottom of footings a minimum of 3'-0" above the mottling height, as defined by the Site Drawings by Nace Engineering/Van Dusen and Steve's Land Surveyors, dated November 2005. A benchmark will be set at a hydrant to confirm elevations. Instead of the RC-2 asphalt damp proofing, we will coat the concrete foundation wall, below grade, with a Polymer-Modified Asphalt coating, a minimum of 40 mils, per IRC 2015 —Section R406.2. The product is called Tuff-N-Dri, by Tremco. The insulated boards are optional, and not required by code. Lastly, Hodorowski Homes uses Appolo Heating and Cooling to perform all of our blower door tests. They will issue a signed and certified notice, once we pass and achieve 3.0 ach or less per IRC 2015. Since ely, Kristan Hodorowski K ' 1-IODOROWSKI • r' I n 0 M F: S BUILDING ON TRADITION May 2, 2019 FILE c CO T n Town of Queensbury Building Department 742 Bay Road Queensbury, NY 12804 Re: Barringer Heights Subdivision To Whom It May Concern, With any new homes in the Barringer Heights Subdivision, Hodorowski Homes will set the bottom of footings a minimum of 3'-0" above the mottling height, as defined by the Site Drawings by Nace Engineering/Van Dusen and Steve's Land Surveyors, dated November 2005. A benchmark will be set at a hydrant to confirm elevations. Instead of the RC-2 asphalt damp proofing, we will coat the concrete foundation wall, below grade, with a Polymer-Modified Asphalt coating, a minimum of 40 mils, per IRC 2015—Section R406.2. The product is called Tuff-N-Dri, by Tremco. The insulated boards are optional, and not required by code. Lastly, Hodorowski Homes uses Appolo Heating and Cooling to perform all of our blower door tests. They will issue a signed and certified notice, once we pass and achieve 3.0 ach or less per IRC 2015. Since ely, ` ristan Hodorowski aePPoke Degrees Above The Rest,SCE 1968/ Main Office 868 Burdeck Street ‘Schenectady,NY 12306 Tel.(518)355-0833 Fax,(518)355-3174 Wappingers Falls Office ‘Vestal OMice 95 Airport Drive Suite | ___ 414 Commerce Road Wappingers Fall,NY 12590,ROBO Pea cence “Tel.(607)729-5847 Fax.(607)797-7520 Property Address|95 Richmond Hills Dr,Queensbury Ny Builder Hodorowski Date of test 11/22/19 Model of Home Ceiling Level Square Feet__|Height Air Volume (Cu.Ft.) Basement 1935 8 15480 1 Floor 1935 9 17415 2nd Floor 1030 8 8240 Total 4400 41135 Blower Door Test TEC Minneapolis Blower Door with TEC DG-1000 Equipment Used_|Manometer Fan Configuration|A Ring fe Measured CFM50_1968 E G E q Vv E Calculated ACHSO 2.9 NOV 25 2019 Testing done in accordance with ASTM E 1827-11 = Thereby certify and attest to the accuracy of the testing results|TOYGfCUEENSOURY rheneles AAbwee— Test performed by: Nick Abrunza Energy Auditor/ BPI Certification Number:5059019 A c , 41-D. 2a." D 56 '- RC, 2.7� 3 E SS', Arf 3 a 4 6 F j_ PG 3 �3 G �5' 1� H 3`�" 3-h 1 ' i 3' &s-r . 55 ` , !oq"6 IDA : 80' 13-K 1e , �' )3L 47 ' �9-►'�'► r'' )34M rCEOVIED AS BUILT AUG 2 9 2019 TOWN OF QUEENSBURY BUILDING&CODES