Loading...
RC-0478-2019TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5904 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 BUILDING PERMIT RC-0478-2019PermitNumber: 295.15-2-4.2TaxMapNo: FOOTHILLS BUILDERS, LLCPermissionisherebygrantedto: 48 JOHN CLENDON RDForpropertylocatedat: In theTown ofQueensbury, to construct orplace atthe above location in accordance with application together with plot plans and other information hereto filed and approved and incompliance with the NYS Uniform Building Codes and theQueensbury Zoning Ordinance Type ofConstruction FOOTHILLS BUILDERS, LLC$200,000.00OwnerName:Single Family - New Owner Address:9Mountainside DR Total Value 200,000.00 Queensbury, NY 12804 Contractor orBuilder'sName / AddressElectrical Inspection Agency FOOTHILLS BUILDERS, LLC 9Mountainside DR Queensbury, NY 12804 Plans & Specifications Single Family Dwelling 1719 s.f. Garage 510 s.f. Lot 5 690.70 Wednesday, July 29, 2020PERMITFEEPAID - THIS PERMIT EXPIRES: Ifalonger period isrequired, anapplication for an extension must bemade to the code Enforcement Officer ofthe Town ofQueensbury before the expiration date.) Tuesday, July 30, 2019DatedattheTownofQueensbury SIGNED BY:for theTown ofQueensbury. Director of Building & Code Enforcement Office Use Only rt: PRINCIP Permit#: RC - OL17 "20 Q_ redif ermit Fee:$ I(2.70 ok742BayRoadQueensbury, NV 12804 Rec. Fee:$ P 518-761-8256 UL 1' 2Q1 nvoice#: I 0 TOWN OF QUEENSBURY Project Location: LiE 10 H ,BUIILDtilf.06491)ES. Tax Map #: Z9 c• I.S" -L - `I .2- Subdivision Name: Sd tlN C rl)DfN i TATtrS TOWN BD RESOLUTION 86-2013 $850 recreation fee for new dwelling unii single family dupe:<-: two-family, multiplefamily apartments condominiums townhouses.and or manufactured modular homes but not mobile homes. This is in addition to the permit fee(s). CONTACT INFORMATION: Applicant: Name(s): S o v T H I LcS B u t LD R.S ISo E LEu U ) Mailing Address, C/S/Z: Yl o ur1 TA (NS t b C hf2 t v€ aLkeeN5&KQ4 NY 12-rra LI Cell Ph.: I ( s-I S ) I - 11 33 Led dine: t (Sty ) 146-3S o (C+`44 Email: FooTt it-LSButLtDERs NC/g G-inAIL. corv\ Primary Owner(s): Name(s): SFArnE AS A PPS t c ANT Mailing Address, CIS/Z: Cell Ph.: _( Land Line: ( Email: Contractor(s): Name(s): S A m E" AS A P P Li C 6N-1" Mailing Address, CIS/Z: Cell Ph.: ( Land Line: _( Email: Architect(s)/Engineer(s): Name(s): 1f\/J fLyAIJ , PE LviSio,i ENG-INE-t ?NC Mailing Address, C/S/Z: 20 o StArTe- 5(0 rrl-tNs FALt_s r-'f )2 0 I Cell Ph.: ( Land Line: I ( s-t p ) -19 2. - 1241-1 Email: t)R..i AN(d VAS toNEN(r . mfq Contact Person for Building & Code Compliance: .)OE LAN C I Cell Ph.: L(5tf ) 1"l 1- 1933 Eat Line: i (V i1 ) 19 3C2.0 LLEL.L--) Email: FOOT tilt-1-Ss3UttOEt2S GMAt L--, c_o ryk Inn Ruildine R('nda f ninrrpmvnt Prinrin(P Strut-hire Reviand Matrh 70111 PROJECT INFORMATION; TYPE: Commercial Residential WORK CLASS: Single-Family Two-Family Multi-Family(#of Townhouse Business Office Retail Hotel/Motel Industrial/Warehouse Garage(#of cars ) Other(describe STRUCTURE SQUARE FOOTAGE_ GARAGE SQUARE FOOTAGE: in floor: I / I `) 1sT floor: > 1 2nd floor: 2nd floor: 3rd floor: r Total square feet: Basement(habitable space): Total square feet: ( ) I `) ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ 2-6 o/ CO 2. Proposed use of the building: R' C.S I D EN 1 i p L 3. If Commercial or Industrial, indicate the name of the business: 4. Source of Heat (circle one): Gas, Oil Propane Solar Other: Fireplaces need a separate rdel Burning Appliances&Chimney Application,one per appliance) 5. Are there any structures not shown on the plot plan?YES NO Explain: 6. Are there any easements on the property? YES NO 7. SITE INFORMATION: q a. What is the dimensions or acreage the parcel? I . I A CR-t S b. Is this a corner lot? YES Ne c. Will the grade be changed as a res the construction?YES 631) d.What is the water source? PUBLIC PRIVATE WELL e. Is the parcel on SEWER or a PRIV E-SEPTIC system? S PT f L Ton 8uikiine P.Code Fnfnrremwnt Prinrinlo Stmrtnro Ravic r1 Marrh?nisi DECLARATION: I. l acknowledge that no construction shall commence prior to issuance of a valid nuilding perm and work will be completed within a 12 month period. 2 If the work is not completed by the 1 year expiration date the permit may be renewed. subject to fees and department approval. 3, I certify that the application, plans and supporting materials are a t rue and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with bcai zoning regulations. 4, I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. I understand that IMre are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. 1 have read and agree to the above: PRINT NAME:S C SIGNATURE:DATE: I (4 t ToO Building&Code Enforcement Prinrinb CFI"uYura Ravicari Marrh AMR SEPTIC DISPOSAL PERMIT APPLICATI ON (oho:::iio->use C)il 7-?, Bay Road.Qu•ensbury, •.l <n-t W P518-76.•, '56 Perm: . fc-O4' - • ZO 1rT Tax Map ID#: AC LIS'! c Z' ._I_ ?'P:,:,,: Project Location: li '3.6 NN CLtIti D o Al c=-1 Primary Owner(s) J FOOTHILLS AuILO&RS LLC, b0€ LEN c Mailing Address p mt,uNTAIz•JS'De bg. Q1.4.6 •Nsilkiz,i I-17 /2 U'1 Phone& Email Csie)'i ll-(933 /CCit)196'3S2e FobTHILLSgNti DEasNy eG-rAA c..co installer/Builder I ,^ Hs A%'PL1CRAii V Mailing Address Phone & Email 1 Engineer 1'p M i Mailing Address kill NAY i(-A N r3 Rb Qute N S 8 Key N ti l 2g o I Phone& Email I I (S'I 0 19(p-ZSI S TCC (sFZN 3(y @ YAfJDo. to M Contact Person for Buikiing&CodeCompliance:lb e- LE`1 F'tn one: CS1B')'111 - 1933 RESIDENCE NFORMATION: L S 0 19(o- 2 Year Built #of bedrooms X gallons per bedroom = totaldaily flow Garbage Grinder Yes 65)1980 or older Installed? {circle one) 1981-1091 Spa or Hot Tub Yes g. - Installed? {circle one)19132=Present 3 t l 0 3 3 6 PARCEL NFORMATION: Topography pc Flat Rolling Steep Slope Slope Soil Nature SandDLoamClay _Other Groundwater At what depth? tU Bedrock/Imperviousmaterial % At what depth? /.i r A Domestic Water Supply ZMunicipal _Well{if well.water supply from any septic system absorption is_ ft.) Percolation Test Rate: ( ' S per minute per inch{test to be completed by licensed eng-eer/arcliect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: Tank size !6 0 gallons{min.size 1000 gallons,add 250 ga lions for each garbage cylinder or spa/hot tub System Absorption field with#2 stone Total length IS'd ft.;Each Trench S'O ft. Seepage Pit with#3 stone How many: Size: Alternative System Bed or other type: Holding Tank System Total required capacity? tank size of tanks NOTES:lAlarm system&associated electrica[work must be inspected bya Town approved electrical inspection agency:2.We will no longer allow systems to be covered until such time as an as-built plans received and approved. The installed system must match the septic layout on file-no exceptions. Declaration:Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void.! have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: JoS' e H LC --i DATE: 1 1(ci I (, SIGNATURE. c\ivv-,,,, DATE: 1 I ( e) i 1 Tom,of OUeensod E.'.-.i rr`,&Code Enforcement Town of Queensbury Thomas R. Van Ness Highway Department Highway Superintendent 742 Bay Road,Queensbury, NY 12804 Home:518-745-0929 Phone:518-761-8211 Fax:518-745-4466 David Duell Deputy Highway Superintendent Home:518-745-0938 DRIVEWAY PERMIT Date: 7 1 S I ! 9 Applicant Name: Foe i N t S P u t LO - (Toe Le-LA c ) Telephone No.: CS ISM 79 1 - (cl 3-6 /( CI S} 796-3SZo Address to be inspected: y ;) o R 1-& C r D e N Return Address: 9 mc,k TA rN SIPS SEE,,s 8,,y N'! 12 8-C 1 Applicant must show exact location and width of driveway(s)to be connected to the highway by placing stakes at the specified location. The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: Preliminary approval NEED Slight Swale Deep Swale Level with the road Level with the top of the paved wing Size culvert pipe to be used (if necessary) 12" 15" 18" 24" 36" Preliminary inspection completed by: Date: Approval by Highway Supt.: or Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: Final Approval Rejected Date: Thomas R. Van Ness, Highway Superintendent David Duell, Deputy Highway Superintendent Town of Queensbury Building&Code Enforcement Principal Structure Application Revised February 2017 Testing Company: Name:LoCascio Energy Solutions Address:20 Ogden Rd. Queensbury , NEW YORK 12804 Phone: 5188573144 Technician: Name:Anthony LoCascio Credentials:HERS Rater#4242961 Email:tony@locascioenergysolutions.com Building Information: Project ID:48 John Address:48 John Clendon Rd Queensbury, NY 12804 Geo-Tag Data:Latitude: 43.341105 Longitude: -73.709740 Timestamp: 2019-12-03 15:04:50 Customer Information: Name:Foothills Builders Address: Measured Leakage:1,135.4 CFM50 Test ID:48 John Purpose of Test:RESNET Multi-Pt Env. Leakage Measured ACH50:2.50 (+/- 4.1%)Effective Leakage Area: 60.5 in² Building Volume:27,230.0 ft³Enclosure Surface Area: 3,444.0 ft² Flow Coefficient (C):85.0 (+/- 17.9%)Exponent (n): 0.663 (+/- 0.052) Correlation Coefficient:0.99910 Test Standard:RESNET 380 Multi-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 66 °F Altitude: 478.0 ft Outdoor Temp: 31 °F Time Average Period: 10 seconds Test Date and Time:2019-12-03 15:33:35 Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -1.3 60.0 -60.3 -59.1 -53.4 1,321.9 Ring A 48.0 -48.6 -47.3 -41.4 1,167.1 Ring A 35.0 -35.2 -33.9 -26.9 946.2 Ring A 23.0 -24.0 -22.7 -152.7 732.8 Ring B 10.0 -12.4 -11.1 -54.0 437.9 Ring B Test Equipment: Flow Device:Model 3 110V Fan Serial #: 3172 Pressure Gauge:DG1000 Serial #: 3172 Calibration Date: 2019-02-18 Deviations from Standard: None Comments: Envelope Leakage Test (Page 2) Report generated by TEC Auto Test version 1.6.3 (2), © 2019 by The Energy Conservatory, Inc. Manual S Compliance Report Job: 48 JOHN CLENDON DR Date: Jul 23,2019 Entire House By: Plan: 1468 Project Information For: FOOTHILL BUILDERS QUEENSBURY, NY 12804 Cooling Equipment Design Conditions Outdoor design DB: 85.0°F Sensible gain: 19210 Btuh Entering coil DB: 75.3°F Outdoor design WB: 71.0°F Latent gain: 4943 Btuh Entering coil WB: 62.6°F Indoor design DB: 75.0°F Total gain: 24153 Btuh Indoor RH: 50% Estimated airflow: 832 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: York Model: YCJD30S41S1H+FC35B3XN1 Actual airflow: 993 cfm Sensible capacity:0 Btuh 0% of load Latent capacity: 0 Btuh 0% of load Total capacity: 0 Btuh 0% of load SHR: 0% Heating Equipment Design Conditions Outdoor design DB: -4.0°F Heat loss: 85313 Btuh Entering coil DB: 65.5°F Indoor design DB: 68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: York Model: TM9X080B12MP11 Actual airflow: 993 cfm Output capacity: 76000 Btuh 89% of load Temp. rise: 50 °F FILE COPY Meets are all requirements of ACCA Manual S. 2019-Jul-23 10:52:29 wrightsoft• Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 ACCA ...ngeworthy\Documents\York\48 JOHN CLENDON DR.rup Calc=MJ7 Front Door faces: N Residential Plans Examiner Review Form RFormPER1 ACCk for HVAC System Design (Loads, Equipment, Ducts) 15Mar09 PecnitcrrgCcrtractrsabsreza QUEENSBURY NY Header Information Contractor: REQUIRED ATTACHMENTS ATTACHED Manual J1 Form(and supporting worksheets): Yes ril No Mechanical license: or MJ1AE Form*(and supporting worksheets): Yes No Ei OEM performance data(heating,cooling,blower): Yes 0 No 0 Building plan#: 1468 Manual D Friction Rate Worksheet: Yes 0 No Duct distribution sketch: Yes D No Home address(Street or Lot#,Block,Subdivision): , Entire House HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature:4 °F Orientation: Front Door faces North Indoor temperature: 68 °F North,East,West,South,Northeast,Northwest,Southeast,Southwest Total heat loss: 85313 Btuh Number of bedrooms: 3 Conditioned floor area: 5050 ft' Summer Design Conditions Number of occupants: 0 Outdoor temperature: 85 °F Indoor temperature: 75 °F Windows Roof Grains difference: 27 gr/Ib at'w50% RH Eave overhang depth: 0 ft Sensible heat gain: 21344 Btuh Internal shade:none Latent heatgain: Blinds,drapes,etc.5492 Btuh Depth window Total heat gain: 26837 Btuh Number of skylights: 0 HVAC EQUIPMENT SELECTION (IRC M1401.3) Heating Equipment Data Cooling Equipment Data Blower Data Equipment type: Gas furnace Equipment type:Split AC Heating cfm: 993umace,Hea pump,Boiler,etc. Ir onditioner,Heat pump,etc. Cooling cfm: 993 Model: York Model: York Static pressure:0 in H2O TM9X080B12MP11 YCJD30S41S1H+FC35B3XN1 Fan's rated extemal static pressure for design airflow Heating output capacity: 76000 Btuh Total cooling capacity:0 BtuhHeatpumps-capacity at winter design outdoor conditions Sensible cooling capacity: 0 Btuh Aux.heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601 .1) Design airflow: 993 cfm Longest supply duct: 0 ft Duct Materials Used Equipment design ESP: 0 in H2O Longest return duct: 0 ft Trunk duct: Total device pressure losses: 0 in H2O Total effective length(TEL): 0 ft Available static pressure(ASP): 0 in H2O Friction rate: 0 in/100ft Branch duct: Sheet metal Friction Rate=ASP+(TELx 10 ) I declare the load calculation,equipment,equipment selection and duct design were rigorously performed based on the building plan listed above. I understand the claims made on these forms will be subject to review and verification. Contractor's printed name: Contractor's signature: Date: Reserved for County.Town Municipality orAuthority having jurisdiction use. Home qualifies for MJ1AE Form based on Abridged Edition Checklist F wrightsoft Right-Suite®Universal 2017 17.0.16 RSU25116 Pro Oct Summary Job: 48 JOHN CLENDON DR l Date: Jul 23,2019 Entire House By: Plan: 1468 Pro'ect Information For: FOOTHILL BUILDERS QUEENSBURY, NY 12804 Notes: Desi• n Information Weather: Glens Falls AP, NY, US Winter Design Conditions Summer Design Conditions Outside db 4 °F Outside db 85 °F Inside db 68 °F Inside db 75 °F Design TD 72 °F Design TD 10 °F Daily range M Relative humidity 50 % Moisture difference 27 gr./lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 80484 Btuh Structure 18295 Btuh Ducts 4829 Btuh Ducts 915 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none) none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 85313 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 17289 Btuh Method Simplified Latent Cooling Equipment Load SizingConstructionqualityAverage Fireplaces 0 Structure 4943 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling none) Area(ft2) 5050 5050 Equipment latent load 4943 Btuh Volume(ft') 40400 40400 Air changes/hour 0.70 0.40 Equipment total load 22232 Btuh Equiv.AVF (cfm) 471 269 Req. total capacity at 0.70 SHR 2.1 ton Heating Equipment Summary Cooling Equipment Summary Make York Make York Trade YORK Trade LX SERIES Model TM9X080B12MP11 Cond YCJD30S41S1H AHRI ref 2008691 Coil FC35B3XN1 AHRI ref 3476917 Efficiency 95.5 AFUE Efficiency 12.0 EER, 14 SEER Heating input 80000 Btuh Sensible cooling 20860 Btuh Heating output 76000 Btuh Latent cooling 8940 Btuh Temperature rise 70 °F Total cooling 29800 Btuh Actual air flow 993 cfm Actual air flow 993 cfm Air flow factor 0.012 cfm/Btuh Air flow factor 0.052 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.80 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. mot WI'1 F1t50Tt'2019-Jul-2310:52:299Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1ACCK ...ngeworthy\Documents\York\48 JOHN CLENDON DR.rup Calc=MJ7 Front Door faces: N O CO CO V (A (T A co N O 0 CD V 0) CT A W N-,_ D-1001-1-CI) 102 r'C, < P-^-n• T o Q p r n Z 0 C) SCp 6 73'2 jlii R DQ g g &-!2 a• D• C2 N q Nft-iti N $ $ q m pg g Po c mod. w Ecna m ° d 60 V D V A m W CD 2 CT W-^ n --"CD 0.C) CT W -"0 CSC) CT W 0 CT W CD 0.0 U W C1 C) CT W-`CD CAV u W N O 0 W O ?< <co O W O .• m 0 n N1uCe T 0nmWNTWCWOTC(] OcCOOOOOOVOOOo0A00000A0000000Vooooo. 2 7 T Tma W Oc 1 /_ W 0' rig 0) W m CO » » » » » co- C y O O O O O O O O O O O O O O-. O O O O O O O O W 0 0 0 0 0 0 O O O O O O Oa ED me ••oe . : . : : rn »W =_ __ pp77 1 p = __- pN' w 00 co =___ =W •_ ___ =N =•_ __- 00 A 00000(V71 00000(T = ____ I O O zit oa C 77 pippp W CNCD N W : r r » , » a§. A= y j W r » » » » W C000 OA 00 00000? 00000 000008 00 N » » » » » 000000 W ON Co 0 n r r r » » r A N (Cp o dD V A N A » » » r r r r r r • i »r ( v v=, CI C2Cp3 g Np CCOJaf N CDWOp1000000000000000000°) 00000° 000i 0 0O0 N a ACV m rh 4 rn . r . » co III Tm i 0 00 0 - -.-.- -OD - - -- -O -- -- -N 000 000OWi00 .....0 - - == - 00 0) gX 3 O —r r r CD0 ' r r V N a 0)) W r » » r » » t i Q N W^ 0o O CC,,,,)) co Y. Ox-0 0 0 W O V o 0 0 0 0 A 000000 O O O O O W 000 0 0 0 0 0 0 W Qp a' 1 C 1V p N r » » » » r r Cp z CC0 00o Cn 00 OCD 000000 0000 00 00000(AO 000 00000 O 0 0 i i i » ». 1 1 » r 7D co 8,r0 COCOp -.- -- -( A( b) 0._ K00 0 = = ===0 = = ===W == ===0) 000 000000 000000 = =__ O mc r * r r » x 8HIMi : 2 Q1 N...4 gam V y »' x ,", » r r * . -.K3 N L V r A o 0 o V 00 000000 0 0 0 0 0 A 0 0 0 0 0 N 000 000000 W W O C Q77?j CWp r » » » » C- pp r r » r r » CO 0 ( a A00000000 00 000000 00000C1) 00000 C)1 000 000000 C 00 0 » » i W N =_ _-=A C N 0s m O 00 0 0 = _ 0 __ ==.=N 00 0 000 000 000000 N O W 0 N I0 0or » » x43 N Z i i » » rr i i m N A T co r » » » » CEO r r r » r r ( NA O 7 CO co » V W A 0) 0) O T W 4N) Co C001000 oW 000000 00000 00000 V 000 000000 W vb. ITf me r » » » »n OWN I CD C Milll » » » » » co N V CD j N 0 V A Z N o 0 0 W 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0) 0 0 0 0 0 V 0 0 0 0 0 0 0 0 0 0O 73 k 888 V i MA W N O CO 00 V 00 CT A W IQ D-1 0 0(r- p 1p 0) 1 C0 0) <— R VZ0 -E f Q z O cy * Nx c* fU m! IU gy .O pp7» xp S to 1 m Xpcm NTm II N,$ 00 II D V A W 0) —CD 0.C) CT 0) -.Cl) a C) CS 0) -,,CD a C) CS N C)Cr 0 CD a C) CT 0) -^CD a C) CT 0) to S 3 g +a 9 I'o'4xcncnmzz c m 3 N m 4/^C CO 0 m 0 N D-0gZ= o m 00 _ 01 a V N(4(4 N 0 W O C C W 1 T. ' N m tY W < <W x 0 O () W 47 N V7 W CO CT C CO O o 0 0 o V o 0 0 0 o A 00 0 0 0 A 00—, 0 0 0 0 o V 0 0 0 0 0 A x g TT o 73 07 r N C N O O 000000 0 0 0 0 0 000000 00 ) 000000 000000 1.10.1.6 z» 3 oa w i s yD m c N p o ' » » , 1011 o C o p o 00 0 --=.--o = =—=-c _=.=--g) coo_000000 000000 = =__:_$) 0 5Qy O O Zl O w r w r • » » • N Cp7 HMIw » i » • w • • CD§7 g x•p g O 2 _. A 0)W)000W 00 000000 00000CWi) 00000A 000 000000 W aoo 4 D c 7C n N0 C) N N » » » » . . r r • • • i r » w » CO`' ^ OM pp a CD I A C7)O)AO 00 A 00 00 000000 0 0 00 0 00 00 0 COi) 000 000000 0 CD 3N 3 D m 0) .-- F Oo o W -- _- _ oao00_ o - - -- =cn -- _._ =o _000 000000 000000 _ _ __:=o xo P.. it) Sx X o =rrr • • ww r x M o w r r k CCIDCDCDL A. y^ 00. C 00 000000 0 0 0 0 0 W 000000 000 000000 a 0 A _Dn 1 C r • S z 3 i 1v 7 F.)-CD A+ NO 00 CWO 00 00 000000 0 0 000CWD 000000 000 000000 y co xDIIH 8o a i ON000 =:: 0 =•-=:=:=a __.== =03 000 000000 000000 ._ _ _ Mx Acxsw N L. W • » » » • • • w j 00000 ,00 000000 00000N 000000 000 r » w w w • 000000 + w w O W O00 w 0 ow c - m tiff ye go0 0- COOVO CA000000 00 000000 00 000N 00000000 000 000000 Jcn : • . w »rn 1 i 1 y °° A cCM o rn 0 0 0 = _ __ _ __ __ _-, 0 0 000000 000000 = _ ==.=N O W 2O s , • , x ?j x O Z c e IQCu : A}3Xao( rc AJ k w g o) n N O) W N O o O N 04 000000 000002 0 0 0 0 0 COO 008 000000 W Q O x ZW 0 710 c2 O 1N A rw » » » •w • • » » » www z N CN))CD WO o0 con 00 0-. 000000 0 0000E 0000 0 00-c 000000Nm X f 0003 V 01 ()t A W F.S. O cp 0) 1 O) 0) AWN—, 71 aHog°° "' v, <5goN8z' 0 -fig (Dz 0 c_* I mc m 0 r z gs _ Q R— Na=.o m »°1xc» N vv gx Xmv g M p.``(j° o ° » I $ $'o mm°pm ».Olt Ro S a ppQ 55Qyj( 66 Q tpi p `f'i a?o_ Cm z P.li ci w. P. w = u a m = a.31 3c3g -_ + s I+ aOVO7Va13A O Co N „cD O. Cr SD —^cD a00-D1 „cD a0 CT 0) 0QDI cD a017 D] „cD a0 U01 7V„' 87 co + B = `a' m 8n'D o o m m m oR. z C> o m n gm O (r N 1G N 0 C w I OO Pr n T w w d)W N V7 W c0 0' C c0 00000V 00000. 00000. 00—, 00000V 00000A 2 9 mo - rn n, O^ O awo rn ' oD m rt . t » . » 06 7 00 0 000000 00000— 000000 Dow 000000 000000 c V1 o p yD 0) Dc cn » » . . »rn . . rt . Ow 2 LZ8coN —— —— O O 0 - - -- =0 - - -- =V -- -- =0 000 000000 000000 — — -- =0 O o N rt rt » rt c 3 y 2 V o A 0 0 0 00 000000 0 0 0 0 O 000000 000 000000 WCrca. $ 0- 0 0 l/ i » » » t » » » » n 0 CD U :L7 N N N 0 0 0 0 0 0 00 000000 000000 000000 000 000000 co CD coNa rt T 8 0 0 3 OO W — — —— =0 — — —— =A —— —— =N OO W og000' OOOooA = — —— =p O O pN A ry 9 c0 51 V O Cam„] • W » » » rt rt » » » 0)V 000c0 O V 000000 OOOOOW 00000 J 00 V 000000 j QOQ 0x O Q O co 1.C co CD Z 3 CD n N j w0 t t t t t V N W O N » » . » » » » » rt » rt 0 mccw000 rnoo ow 000000 000000 0cocoa)) oo c. 00000c01 uJ 0S.o V W D = — =— =0KOOOO = _ __ _ __ _= 0 000 000000 O O O o O O = _ __ =8 O t ( pvpA 0 - w o rt rt co a rn0 L W c0 N O O O V O co 000000 000000 co 0 0 0 0 0—, 000 000008 W $O O 4 i i I » » » » » » c0 » y G W c ffl W t » » » W rt t » Q c°'ocd3W000zioo 00 000000 00000-k oo000nn) coo 000000 C._ A 7'0 » » t w : » a A C CO a o W v 0 N L 0o cm 0 = _ == =+ 71 == == = w OOO o0ocnoo OOOOOc1 = _ __ _& xo w 0 NIO QA 0 Milli !Mill rt rt rt =pr x 0 ZP t . t w_ n) N CO 61 C 0 08010C W » 8-1 0 W N V W 0o N mWVNWOOOWON000000oOOOOW000000000000000WQ0 Z v vP t » » » » nv O mN t » » . . » » » » » » » c0 Z Mk W J w w o wo o O o cO o 0 o m 000000 0 0 0 0 0 a" O o o o O A 000 000000 0 O 888 V m (T A W N p m V o— o 0 A W N' DHon1-1-cn 5 ! i1I1 t/ T 0 HP 0 ofi x IH1 r" c)xrz a au-§ Ui alRimp Q 7 m p 010 A m W -.maOQO -^ma() W -^ma.oum C)0m maOad *maO0W 8 S 9 +-_ S 21E xcnv mzz c) mmmzc) W y D m o m v a in za o m Ow — a a O 0 6 N lam@ N 0 W O C C co w W m G < x 0 p , C) O W Na N W W jC C co 00000 V 0000 O.P 00000. 00 N f0 A A O O O O O V O O O O O A Tmao Z4.17 N c_ 0 ON W 7s 07 ( J p7 r • • + r p A OD O0 C = O O O :::::00000 Oo00000o000000 OOOOOO 0 W' 0 00 W ==-== 0 =___ = 0 =•-_._= O 00O 0 W000O o 00 o OW • ====A 3'o Om < ppp O Z N a a : a * • x C 1 x W 10 m " . • . . • • wA (O rn w rc Fjy co0W O 2 - 0) Vcn000N oW OO0000 00000cn o0000W 000 000000 m ts zD X' V000 H r Ov N i i i i N O tT A O p p N O]II A D c §m 0 0 0 0 0 0 00 000000 000000 000001 000 000000000 3 O m vN D o O m R. W 0 — I oO -N r (O Cal1C m R, H O C) z Hill ! • • • • • • t0 a)7 N o D 0) C x L v 7- C)vW v L m Q0. D a A K X rt • • w k M M 0) C co co N 0 O x N Z p i i i x O c N m W z i3N r • •r • • 0 0 m n, Z A CNO O 73 REScheck Software Version 4.6.4 ci Compliance CertificateWE, o CSI 1 ' I' 14 : Project John Clendon Dr JUL 1 tl 2C)19 c1-1 0 oinCCJ Energy Code: 2015 IECC TOWN OF C UEEN QFS Y J -o Location: Glens Falls, New York BUILDING&CO N Construction Type: Single-family y tri 5 0 Project Type: New Construction O -0 ' Conditioned Floor Area: 1,722 ft2 N •3 c -: Glazing Area 14% Tr N ea V Climate Zone: 6 (7635 HDD) to = N Permit Date: 1-1 t C e-i Permit Number: If) O —1 0 C) O OO LL Construction Site: Owner/Agent: Designer/Contractor: N U. 0 Lot 5 Foothills Builders Daniel W Ryan P.E. NY 48 John Clendon Dr 206 Glen Street Lot 5 Suite 30 Queensbury, NY 12804 Glens Falls, NY 12801 518-792-9264 dryan@dwrpe.com ompliance: Passes using UA trade-off Compliance: 0.4%Better Than Code Maximum UA: 246 Your UA: 245 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter Wall 1: Wood Frame, 16" o.c. 1,462 21.0 0.0 0.057 71 Window 1:Vinyl Frame:Double Pane with Low-E 139 0.290 40 Door 1: Glass 40 0.290 12 Door 2: Solid 18 0.140 3 Door 3: Solid 20 0.240 5 Ceiling 1: Raised or Energy Truss 1,722 38.0 0.0 0.025 43 Basement Wall 1: Solid Concrete or Masonry 1,425 0.0 15.0 0.046 65 Wall height: 7.8' Depth below grade: 6.8' Insulation depth: 7.8' Window 2: Vinyl/Fiberglass Frame:Double Pane 3 0.400 1 Window 3:Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.290 5 REVIEWED FOR FILE COPY ENERGY CODE COMPLIANCE Project Title: John Clendon Dr Report date: 07/12/19 Data filename: C:\Users\Irobision\Dropbox\DWRPE Engineering\Active Projects\1468 - DES - FHB 48 John Page 1 of10 Clendon Dr\1468 Rescheck.rck Compliance Statement: The proposed building design described here is co tent with the building plans, specifications, and other calculations submitted with the permit application.The proposed buil ' ha been designed to meet the 2015 IECC requirements in REScheck Version 4.6.4 and to comply with the mandatory requir ents I' ed in the REScheck Inspection Checklist. Name-Title Signature D to ii o 1\1E , to 1/ cr 0 1 • ui a do 0 t• / Project Title:John Clendon Dr Report date: 07/12/19 Data filename: C:\Users\Irobision\Dropbox\DWRPE Engineering\Active Projects\1468 - DES - FHB 48 John Page 2 of10 Clendon Dr\1468 Rescheck.rck 0 REScheck Software VersionChecklist 4.6.4 Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions Req.ID 103.1, Construction drawings and Complies 103.2 documentation demonstrate Does Not PR1]1 energy code compliance for the building envelope.Thermal Not Observable envelope represented on Not Applicable construction documents. 103.1, Construction drawings and Complies 103.2, documentation demonstrate Does Not 403.7 energy code compliance for PR3]1 lighting and mechanical systems. Not Observable ar Systems serving multiple Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr Does Not PR2]2 on loads calculated per ACCA Cooling: Cooling: I, Manual J or other methods Not Observable approved by the code official. Btu/hr Btu/hr Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact(Tier 3) 3 Project Title: John Clendon Dr Report date: 07/12/19 Data filename: C:\Users\Irobision\Dropbox\DWRPE Engineering\Active Projects\1468 - DES - FHB 48 John Page 3 of10 Clendon Dr\1468 Rescheck.rck Section Plans Verified Field Verified Foundation Inspection Value Value Complies? Comments/Assumptions Req.JD 402.1.1 Conditioned basement wall R- R- Complies See the Envelope Assemblies FO4]1 insulation R-value.Where interior R_ R- Does Not table for values. insulation is used, verification Not Observable may need to occur during Insulation Inspection. Not ONot Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall Complies FO5]' insulation installed per ODoes Not manufacturer's instructions.Not Observable Not Applicable 402.2.9 Conditioned basement wall ft ft ElComplies See the Envelope Assemblies FO6]1 insulation depth of burial or Does Not table for values. distance from top of wall.Not Observable Not Applicable 303.2.1 A protective covering is installed OComplies FO11]2 to protect exposed exterior Does Not insulation and extends a Not Observable minimum of 6 in. below grade. Not Applicable 403.9 Snow-and ice-melting system EComplies FO12J2 controls installed.Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 tHigh Impact (Tier 1) i 2jMedium Impact (Tier 2) 3 Low Impact(Tier 3) J Project Title:John Clendon Dr Report date: 07/12/19 Data filename: C:\Users\Irobision\Dropbox\DWRPE Engineering\Active Projects\1468 - DES - FHB 48 John Page 4 of10 Clendon Dr\1468 Rescheck.rck Section Plans Verified Field Verified Framing/ Rough-In Inspection Value Value Complies? Comments/Assumptions Req.ID 402.1.1, Door U-factor. U- U- Complies See the Envelope Assemblies 402.3.4 Does Not table for values. FR1]' Not Observable Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- DComplies See the Envelope Assemblies 402.3.1, average). Does Not table for values. 402.3.3, 402.3.6, Not Observable 402.5 Not Applicable FR2]1 303.1.3 U-factors of fenestration products Complies FR4]1 are determined in accordance Does Not with the NFRC test procedure or Not Observable taken from the default table. Not Applicable 402.4.1.1 Air barrier and thermal barrier Complies FR23]1 installed per manufacturer's Does Not instructions.Not Observable Not Applicable 402.4.3 Fenestration that is not site built Complies FR2O]1 is listed and labeled as meeting Does Not AAMA/WDMA/CSA 101/I.S.2/A440 Not Observable or has infiltration rates per NFRC 400 that do not exceed code Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures Complies FR16]2 sealed at housing/interior finish Does Not and labeled to indicate <_2.0 cfm leakage at 75 Pa. Not Observable Not Applicable 403.2.1 Supply and return ducts in attics Complies FR12]1 insulated >= R-8 where duct is Does Not 3 inches in diameter and >=Not Observable R-6 where < 3 inches. Supply and return ducts in other portions of Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for < 3 inches in diameter. 403.3.3.5 Building cavities are not used as Complies FR15]3 ducts or plenums.Does Not Not Observable Not Applicable 403.4 HVAC piping conveying fluids R- R- Complies FR17]z above 105 °F or chilled fluids Does Not below 55 °F are insulated to >_R- 3 Not Observable Not Applicable 403.4.1 Protection of insulation on HVAC Complies FR24]1 piping. EDoes Not ENot Observable Not Applicable 403.5.3 Hot water pipes are insulated to R- R- Complies EFR18P >_R-3. Does Not Not Observable Not Applicable 403.6 Automatic or gravity dampers are Complies FR19]2 installed on all outdoor air Does Not intakes and exhausts.Not Observable Not Applicable 1 1 High Impact (Tier 1) ®Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: John Clendon Dr Report date: 07/12/19 Data filename: C:\Users\Irobision\Dropbox\DWRPE Engineering\Active Projects\1468 - DES - FHB 48 John Page 5 of10 Clendon Dr\1468 Rescheck.rck Additional Comments/Assumptions: 11High Impact(Tier 1) 2 Medium Impact (Tier 2) 1 3-Low Impact(Tier 3) Project Title:John Clendon Dr Report date: 07/12/19 Data filename: C:\Users\Irobision\Dropbox\DWRPE Engineering\Active Projects\1468 - DES - FHB 48 John Page 6 of10 Clendon Dr\1468 Rescheck.rck Section Plans Verified Field Verified Insulation Inspection Value Value Complies? Comments/Assumptions Req.ID 303.1 All installed insulation is labeled Complies IN13]2 or the installed R-values Does Not provided. Not Observable Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the Wood Wood Does Not table for values. 402.2.6 wall insulation on the wall Mass Mass Not Observable IN3]' exterior, the exterior insulation requirement applies (FR10).Steel El Steel Not Applicable 303.2 Wall insulation is installed per Complies IN4]' manufacturer's instructions. Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 jHigh Impact(Tier 1) rjMedium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title:John Clendon Dr Report date: 07/12/19 Data filename: C:\Users\lrobision\Dropbox\DWRPE Engineering\Active Projects\1468 - DES - FHB 48 John Page 7 of10 Clendon Dr\1468 Rescheck.rck Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions Req.ID 402.1.1, Ceiling insulation R-value. R- R- Complies See the Envelope Assemblies 402.2.1, Wood Wood Does Not table for values. 402.2.2, Steel Steel ENot Observable402.2.E[ FI1]' ENot Applicable 303.1.1.1, Ceiling insulation installed per Complies 303.2 manufacturer's instructions. Does Not FI2]' Blown insulation marked every 300 ft2. Not Observable Not Applicable 402.2.3 Vented attics with air permeable Complies FI22]2 insulation include baffle adjacent Does Not to soffit and eave vents that extends over insulation. Not Observable DNot Applicable 402.2.4 Attic access hatch and door R- R- Complies F13]' insulation >. R-value of the Does Not adjacent assembly.Not Observable ENot Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = Complies FI17]' ach in Climate Zones 1-2, and Does Not 3 ach in Climate Zones 3-8. Not Observable Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 Complies FI4]' cfm/100 ft2 across the system or ft2 ft2 Does Not 3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in Not Observable tests, verification may need to ONot Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 Complies F127]' determine air leakage with ft2 ft2 Does Not either: Rough-in test: Total leakage measured with a ENot Observable pressure differential of 0.1 inch ENot Applicable w.g.across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated Complies FI24]' by manufacturer at <=2%of Does Not design air flow. ENot Observable ENot Applicable 403.1.1 Programmable thermostats Complies FI9]2 installed for control of primary Does Not heating and cooling systems and initially set by manufacturer to Not Observable code specifications. ENot Applicable 403.1.2 Heat pump thermostat installed Complies FI10]2 on heat pumps. Does Not Not Observable ENot Applicable 403.5.1 Circulating service hot water Complies Fill]2 systems have automatic or Does Not accessible manual controls. Not Observable Not Applicable 1 High Impact (Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title:John Clendon Dr Report date: 07/12/19 Data filename: C:\Users\Irobision\Dropbox\DWRPE Engineering\Active Projects\1468 - DES - FHB 48 John Page 8 of10 Clendon Dr\1468 Rescheck.rck Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions Req.lO 403.6.1 All mechanical ventilation system Complies F125]2 fans not part of tested and listed Does Not HVAC equipment meet efficacy and air flow limits. Not Observable Not Applicable 403.2 Hot water boilers supplying heat Complies F126]2 through one-or two-pipe heating Does Not systems have outdoor setback control to lower boiler water Not Observable temperature based on outdoor Not Applicable temperature. 403.5.1.1 Heated water circulation systems Complies FI28]2 have a circulation pump.The Does Not system return pipe is a dedicated return pipe or a cold water supply Not Observable pipe.Gravity and thermos- Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems Complies FI29]2 comply with IEEE 515.1 or UL Does Not 515.Controls automatically adjust the energy input to the Not Observable heat tracing to maintain the Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that Complies FI30]2 have recirculation pumps that Does Not pump water from a heated water supply pipe back to the heated Not Observable water source through a cold Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104°F. 403.5.4 Drain water heat recovery units Complies F131]2 tested in accordance with CSA ElDoes Not B55.1.Potable water-side pressure loss of drain water heat Not Observable recovery units < 3 psi for Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent Complies FI6]1 fixtures or 75% of permanent Does Not fixtures have high efficacy lamps. Does not apply to low-voltage Not Observable lighting. Not Applicable 404.1.1 Fuel gas lighting systems have EComplies F123]3 no continuous pilot light.Does Not Not Observable Not Applicable 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) ©Low Impact(Tier 3) Project Title:John Clendon Dr Report date: 07/12/19 Data filename: C:\Users\Irobision\Dropbox\DWRPE Engineering\Active Projects\1468 - DES - FHB 48 John Page 9 of10 Clendon Dr\1468 Rescheck.rck Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions Req.ID 401.3 Compliance certificate posted. Complies F17J2 ElDoes Not Not Observable Not Applicable 303.3 Manufacturer manuals for Complies FI18]3 mechanical and water heating Does Not systems have been provided.Not Observable Not Applicable Additional Comments/Assumptions: 1 II High Impact (Tier 1) 2 I Medium Impact(Tier 2) 3 Low Impact(Tier 3) 1 Project Title:John Clendon Dr Report date: 07/12/19 Data filename: C:\Users\Irobision\Dropbox\DWRPE Engineering\Active Projects\1468 - DES - FHB 48 John Page 10 of10 Clendon Dr\1468 Rescheck.rck 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 15.00 Floor 0.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass& Door Rating U-Factor SHGC Window 0.29 Door 0.29 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments kk, . 100 ECM HEAT RECOVERY VENTILATOR r- ENGINEERING DATA LIFEBRERTH lit THERMALLY CONDUCTIVE,PATENTED DEFROST ALUMINUM CORE Recirculating damper defrost system. The counter-flow heat recovery core transfers heat between the two airstreams.It is easily removed for cleaning or service. CASE Twenty gauge prepainted galvanized steel for superior corrosion resistance.Insulated to MOTORS AND BLOWERS prevent exterior condensation.Drain connections 2-1/2 in.(12 mm)0D.Balancing ports High efficiency electronic commutate ECM motor,for maximum energy savings.Each are located on door. airstream has one centrifugal blower,with multiple fanspeed operations driven by one double shaft motor. ELECTRONICS The DXPLO2 control included with the unit can be wall mounted in a central location of FILTERS the home.3 wire 20 gauge(min.)100 ft length(max.). Washable antimicrobial MERV 6 air filters in exhaust and supply airstreams. MOUNTING WARRANTY Four threaded inserts at corners of the cabinet designed to accept the"s' hooks and Units carry a lifetime warranty on the HRV core and a S year hanging straps supplied with the unit replacement parts warranty. OPTIONAL ACCESSORIES: Weather Hood T9-EAGille94 Terminator Wireless 20/40/60 99-185 9-EAG 99 FAGS Fitting Min Timer la 99 186 99-EAG6 99 TM4 99 DETO2 99-187 lir 99 EAGB 99 TMS s 99-TM6 LIFEBREATH CONTROL OPTIONS TIMER OPTIONS 99-DET01-Lifebreath 20/40/60 Minute TimerFEATURES99-DXPLO2 99-BCO2 99-BC03 99-BC04 Initiates high speed Ventilation for 20,40 or 60 minutes.3 wire connection.5 speed fan operation on each mode 99-DET02 2 speed fan operation(Low/High) Wireless Lifebreath 20/40/60 Minute Timer Continuous low speed fan operation V Initiates high speed Ventilation for 20,40 or 60 minutes.Wirelessly connects to main control for Humidity control through adjustable Dehumidistat V V ease of installation.40'approximate range. Excusive to Lifebreath. Large digital LCD screen 99-RX02-Wireless Lifebreath Repeater LED status indicator lights V V V Extends range of 99-DET02 Wireless Timers.Plugs into 120V power outlet.Wirelessly connects to Continuous Ventilation main control and 99-DET02.Install at halfway point between timer and main wall control if timer Continuous Recirculation is out of range. 20 ON/40 OFF e_ 1w 10 ON/50 OFF 20 ON/40 Recirculation V 20/40/60 min.High speed override button V 99 DXPLO2 99-DET02 Compatible with 99-DET02 Wireless Timer 3 wire connection V V V L IFEBRERTH II Indoor Air systems 100ECM(9-11-18) www.lifebreath.com 100 ECM k, HEAT RECOVERY VENTILATOR r , PERFORMANCE (HVI CERTIFIED) LIFEBRERTH a, 0.1(25) 0.2(SO) 0.3(75) 0.4(100) 0.5(12S) 0.6(150) ELECTRICAL SPECIFICATIONS IN.W.G.(PA) CFM(L s) CFM(Lis) CFM(L s) CF M IL s) CFM IL s) CFM(L S) VAC @ 60Hz 120 Net Supply Airflow 161(16) 143(68) 129(61) 114(54) 97(46) 78(31) Watts/Low Speed 40 Gross Supply Airflow 165(78) 147(69) 131(62) 117(55) 102(48) 81(38) Watts/High Speed 115 Gross Exhaust Airflow 229(108) 215(101) 210(99) 203(96) 184(87) 142(67) Amp Rating 1.15 Sensible Effectiveness(ASE) 180 WEIGHT: @ 64 CFM(30 Us) 32°F(0°C) 78% 160 71 LBS(32 KG) Sensible Efficiency(SRE) 32°F(0°C) 71W° 140 SHIPPING WEIGHT: @ 64 CFM(30 Us) E 1zo 73 LBS(33 KG) u Sensible Efficiency(SRE) 32°F(0°C) 69% ion @ 95 CFM(45 Us) o so NOTE:Sensible Efficiency(SRE) a @ 68 CFM(32 Us) 13°F(-25°C) 64% 60 Front clearance of 25 in.(635 mm)is 4 recommended for servicing unit All ducts zo use 6 in.(152 mm)round collars.Balancing e dampers are located in all air streams. 2100. ISO a itCUS19001 --- ..--. 0.1 0.2 0.3 0.4 0.5 0.6 e. CERTIFIED Static Pressure(in w.g.) DIMENSIONS FRONT VIEW SIDE VIEW I i. Recirculating Fitter 14 3/4 in. 75 Defrost T" Gamperiiii A . Removable 11&/ I Blower Heat 4iStale air to outsideRecovery Trir Motor E Core i• Fresh air from outside Stale air from inside I Fri el Fresh air to inside 6 Rou in. nd( 152 Collammrs) I, — 33 5/8 in.(854 mm) — 'I V v Date: WARRANTY Contractor: Units carry a lifetime warranty Tag: on the HRV core and a 5 year replacement parts warranty. Project' pty:Supplier: Engineer: Quote#: All units conform to FSA and UL standards NI Control: Submitted By. LIFEBRERTH at Indoor Air Systems Timer: Timer Dty: 100ECM(9-ll-18) www.lifebreath.com