Loading...
blower door testDate: City: Queensbury State: NY Zip: 12804 Phone #518-793-7277 Email: City:Queensbury State: NY Zip: 12804 Phone # Email: 1944 sq ft Volume = Blower Door Diagnostics: Ring Inside Temp: Baseline Pressure -50 Pa.A Outside Temp: Fan Pressure 160 Pa.B C 756 cfm@50 New York State Requires builders run a blower door test on new residential buildings to ensure a maximum air leakage of three air changes per hour (ach50). *ACH test results are considerably lower than building standards. Mechanical Ventilation is highly recommended. Blower Door testing performed by: Jack Hall Plumbing & Heating, Inc. 165 Bay St Glens Falls, NY 12801 518-412-7505 ID: 1015618 Ventilation requirements: Building has a HRV installed.YES NO 4/30/2019Contractor: Clute Enterprises, Inc Maximum CFM 50 to achieve less than 3 ACH = 777 Volume: 15552 x 3 = 46656 /60 = 777 CFM @ 50 CFM@50 x 60 / Volume = 2.91 ach Open Actual Flow @ CFM50 = (Height x Living) + (Height x Basement) X 3 / 60 = ACH per Hour BLOWER DOOR TEST FORM Contractor Address: 6 Holden Ave Location tested: 43 Country Club Rd Customer Name: cluteenterprises@gmail.com