HRV/ERV (..e,„ , “,,,,,,y....;,„..„.., ___ __ , ,_„........., ,__ _ . ,,,. CI L k-'e Lto Y-15'1'f(A C-\-i LIFEBREAtrf INOOOR AIR SYSTEMS 4 Sizing and Selecting a Lifebreath HRV or ERV Step 1:Follow these general guidelines to determine the best HRV or ERV for your application 0-1" \^ . Option 1:Size your Residential unit by Air Exchange (ac/hr) Method 4 I�t COGL0-1" -L -�> `120 Step 1 Step 2 01,,:),P0Sb1,,krLt., N.1) (Z v+- 2400sgft(L x W)with 9' (H) ceiling ac/hr=(Total Cubic Volume x.35)/60 Cubic volume_=(L x W x H) or(2400 x 9) x.35/60min = 126cfm *In all cases local and all other codes requirements must be followed Option 2:Size your Residential unit using ASHRAE 62.2 (Minimum requirement) Residential Ventilation Air Requirements(CFM/Bedrooms) Sizing I9-RAE622TABLE 4.1a 1 2 3 4 5 Floor Area Sq.ft. <500 30 38 45 - 53 60 501-1000 45 53 60 68 75 1001-1500 60 68 75 83 90 1501-2000 ( 75 — 837) 90 98 105 2001-2500 90 105 113 120 2501-3000 105 113 120 128 135 3001-3500 120 128 135 143 150 3501-4000 135 143 150 158 165 4001-5000 150 159 165 173 180 5000-5001 165 173 180 188 195 *In all cases local and all other codes requirements must be followed Size your Commercial unit—Note it's recommended a mechanical engineer always be consulted. Application Occupant CFM/Person CFM/SQFT Comments Density/1000sgft Retail Stores 15 10 Classroom 25-35 15 Varies with age Offices 5 10 Conference Rooms 50 15 Hair/Nail Salons 25 20 Do not Undersize Pet Shops 1 Physical Therapy 20 15 Bars/Lounges 100 10 Non-Smoking Health Clubs 40 20 Only 10/1000 in weight room *Swimming Pools 1-10 Varies greatly with temperature Places of Religion 120 5 EMS Calculator Page 1 of 14 6 EMS HVAC Load Calculator www.hvacloadcalculator.com Date: Wed Jan 30 Loaded Document: CLUTE Welcome - GFOIL 2019 12:58pm THORNAPPLE Company Info Client Information Company GF HEATING OIL LLC Name CLUTE ENTERPRISES Preparer BRIAN NELSON Addressl 6 HOLDEN AV, QUEENSBU Phone (518) 792-2220 Address2 43 COUNTRY CLUB RD QU Email brian®gfheatingoil.com Address3 Phone (518) 793-7277 Email Date 30-Jan-2019 This HVAC load calculation has been performed using sound engineering principles as prescribed by Manual J eighth edition and ASHRAE Handbook of Fundamentals. Duct sizing has been performed as prescribed by Manual D. 1. Design Conditions(Temp. F) Check If Using Celcius INDOOR OUTDOOR TEMP Front of East DIFF Building is Facing WINTER 70 -20 90 Total 1700 Sq.Ft SUMMER 65 95 30 Conditioned Area https://ems-residential.hvacloadcalculator.com/app/ 1/30/2019 ' EMS Calculator Page 3 of 14 Distance of OH from top of 1.6 1.6 1.6 1.6 window (A) Length of overhang (B) 1.6 1.6 1.6 1.6 Total linear ft. across top 12 7 4 0 of windows located below overhang Solar GainThrough Glass [.:Check this box if using manufacturer specifications and enter the latitude, U-value and SHGC Latitude 45 U-Value SHGC Facing Area(sq ft) Type Glass HTM Unshaded Shaded BTUH North or 45 Double v 24.00 0 55 1,326 Shaded NE/NW 0 v 0.00 0 0 0 South 75 Double v 40.00 65 10 2,590 SE/SW 0 „ 0.00 0 0 0 East 0 Double v 75.00 0 0 0 West 21 Double v 75.00 21 0 1,575 Does glass have reflective No v 1 5,491 coating? Skylight 0 Clear v 150 0 Total 5,491 Solar Gain https://ems-residential.hvacloadcalculator.com/app/ 1/30/2019 EMS Calculator Page 5 of 14 Floor Over Crawl 0 No Insulation v 0.37 0 0 or Unheated Basement Open-Beach 0 0.00 0 0 House Above Carport Slab On 0 No Insulation v 0.80 0 0 Grade - enter-linear ft Infiltration- 1441 8,316 1,386 Enter cubic-ft of building People 690 600 Appliances 3 Enter Value Sub Total 23,260 10,639 Duct Loss/Gain 0 0 625 Total Sensible Load 23,260 10,639 Latent Load 1,142 Total Latent Load 2,368 SUMMARY Heating Load Sensible Cooling Latent Cooling Total Cooling Load *Nominal Tons 23,260 10,639 2,368 13,006 1.18 OUTDOOR AIR FLOW RATE 39.5 * CAUTION - The cooling capacity of the air conditioner must meet both, sensible and latent loads. It is recommended a Manual S haps://ems-residential.hvacloadcalculator.com/app/ 1/3 0/2019 EMS Calculator Page 7 of 14 Basement Load Calculation Elements of Area Insulation/R-value U-Value Heat Heat Gain Latent Load or Lin. Loss Btuh Btuh Ft Btuh Solar Gain 6,840.00 From Glass Gross Wall 480 Above Grade Glass 1 136 Double v 0.56 6,854 Doors 0 0.00 0 0 Net Wall- 344 R-19 v 0.06 1,858 619 Above Grade Wall Below 480 R-19 v 0.03 1,296 432 Grade Ceiling 0 No Insulation v 0.41 0 0 Floor 896 0.02 1,935 1,935 Infiltration- 716 2,957 986 Enter cubic-ft of building People 2 460 400 Appliances 0 Total Sensible Load 14,900 9,337 Latent Load 812 Total Latent Load 1,512 Basement Summary https://ems-residential.hvacloadcalculator.com/app/ 1/30/2019 EMS Calculator Page 11 of 14 Furnace RUUD RS 70000 Rc5 'A .70\27n ryi5 Boiler 0 0 Heat Pump RUUD 30000 3600( -6000 or Air Conditioner A-\3?�0 A , NA Evaporator RUUD R( c 3(,( 7 S-Vckyn C 4 co;l Air Handler Total 69036.8 29845.199999999997 35814.24 -5969.04 Capacity with Altitude Correction Selected OVERSIZED OVERSIZED OK UNDERSIZED Equipment Size Heating CFM Cooling CFM External Static Pressure of (recommended) Blower 1200 1,915 0 Available static presure for Supplemental heat needed for heat duct system pump Blower ext. 0 HP capacity @ 47F 0 static press Coil press HP capacity @ 17F 0 0 drop* HP capacity ® 0 Filter press 0 ODDT drop* BTUH 38,160 Register press 0 supplemental heat drop https://ems-residential.hvacloadcalculator.com/app/ 1/30/2019 • EMS Calculator Page 13 of 14 Efficiency Fuel Cost Air Conditioning 0 0 Heating 0 0 0.00 V Total annual operating cost of system 1 System #2 (Old or less efficient system) Efficiency Fuel Cost Air Conditioning 0 0 Heating 0 0 0.00 v Total annual operating cost of system 1 PAYBACK AND ROI Cost of new or more efficient system 0 Cost of less efficient system 0 Rebates or credits 0 Additional Investment 0.00 Yearly Savings Payback(Years) https://ems-residential.hvacloadcalculator.com/app/ 1/3 0/2019