inspection 06142019INSPECTION WORKSHEET (PTI-003358-2019) PT-0135-2019Permit Management Case Number:Case Module: 06/14/2019Partial Pass Inspection Date:Inspection Status: Mark SmithProperty Transfer Inspections Inspector:Inspection Type: 289.10-1-34.1 Job Address:Parcel Number: 15 Fernwood Rd Lake George, NY 12845 Contact TypeCompany NameName ApplicantJames Keller Primary OwnerWilliam Fosbrook Checklist ItemPassedComments Capacity in gallonsTrue1000 gallons Concrete tankTrue Temperature (Fahrenheit)True65 degrees Visible scum layerTrue Number of tank compartmentsTrue 1000 gallon septic tank to a seepage pit of approximately 1000 gallons Plumbing fixtures tested & confirmedTrueAll fixtures flow into septic tank System appears to have functioned adequatelyTrueSystem working as it should. Depth below grade to top of tankTrue 48" to top of septic tank, a riser must be installed before I can approve it This system Access riser? (if yes, depth to cover)False 48" to top of septic tank, a riser must be installed before i can pass this inspection. Inlet baffleTrue Recommend upgrade/expand/replace 1+ componentsFalse Install riser at septic tank on inlet or out side. Property transfer permit can not be closed until new system is installed at 15 frenwood drive A riser is required at existing septic tank. Test each fixture flow to septic tankTrue Liquid level AT/ABOVE/BELOW (one) discharge invertTrueLiquid is at discharge invert Outlet baffleTrue WeatherTrueSunny, 65 degrees Main tank cleanout size and locationTrueSeptic tank located at front right of house, under driveway. Seepage Pits: NumberTrueOne seepage pit of approximately 1000 gallons Water tight tankTrueYes OtherFalse December 09, 2019Page 1 of 1