inspection 06112019INSPECTION WORKSHEET (BINS-003472-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0170-2019Case Module:Permit
Inspection Date:Tue Jun 11, 2019Inspection Status:Partial Pass
Inspector:Mark SmithInspection Type:Building Foundation
Job Address:57 GRAND VIEW DRParcel Number:289.16-1-10
Queensbury, NY 12804
Contact TypeCompany NameName
Granted PermissionGarvey, Marc
ApplicantHilltop Construction
Primary OwnerGarvey, Marc
ContractorHilltop Construction
Checklist ItemPassedComments
Building Inspector NotesNO5/8/19 footings approved
5/17/19 foundation walls approved
5/28/19 foundation waterproofing approved, back fill
approved for garage only. Footings drains not completed at
side and rear of house. Call for recheck when ready.
6/11/19 poly under slab with 6x6 wielded wire mesh verified
FootingsYES5/8/19 footings approved
PiersNO
Monolithic SlabNO
Reinforcement in PlaceNO2rows of #4 continuous
Verticals to be wet set
Jun 11, 2019Page (1)
INSPECTION WORKSHEET (BINS-003472-2019)
Checklist ItemPassedComments
Reinforcement in PlaceNO3 rows of #4 rebar continuous
Footing Dowels or Keyway in placeYES#4 rebar 4' on center one foot down from top of wall
Foundation DampproofingNO
Foundation WaterproofingNO5/28/19 waterproofing verified
Footing Drain Daylight or SumpYESVerified 6/3/19
Footing Drain stone - 6 mil polyYESWith fabric
Backfill ApprovalYESFor remainder of east and north 6/3/19
Plumbing Under SlabNO
PVC / Cast / CopperNO
Foundation Insulation Interior / ExteriorNO
Rough Grade 6 inch drop within 10 ft.NO
Poly Under SlabYES6/11/19 poly under slab verified at garage only
Smith, Mark (Inspector)
Jun 11, 2019Page (2)