inspection 06112019INSPECTION WORKSHEET (BINS-003472-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0170-2019Case Module:Permit Inspection Date:Tue Jun 11, 2019Inspection Status:Partial Pass Inspector:Mark SmithInspection Type:Building Foundation Job Address:57 GRAND VIEW DRParcel Number:289.16-1-10 Queensbury, NY 12804 Contact TypeCompany NameName Granted PermissionGarvey, Marc ApplicantHilltop Construction Primary OwnerGarvey, Marc ContractorHilltop Construction Checklist ItemPassedComments Building Inspector NotesNO5/8/19 footings approved 5/17/19 foundation walls approved 5/28/19 foundation waterproofing approved, back fill approved for garage only. Footings drains not completed at side and rear of house. Call for recheck when ready. 6/11/19 poly under slab with 6x6 wielded wire mesh verified FootingsYES5/8/19 footings approved PiersNO Monolithic SlabNO Reinforcement in PlaceNO2rows of #4 continuous Verticals to be wet set Jun 11, 2019Page (1) INSPECTION WORKSHEET (BINS-003472-2019) Checklist ItemPassedComments Reinforcement in PlaceNO3 rows of #4 rebar continuous Footing Dowels or Keyway in placeYES#4 rebar 4' on center one foot down from top of wall Foundation DampproofingNO Foundation WaterproofingNO5/28/19 waterproofing verified Footing Drain Daylight or SumpYESVerified 6/3/19 Footing Drain stone - 6 mil polyYESWith fabric Backfill ApprovalYESFor remainder of east and north 6/3/19 Plumbing Under SlabNO PVC / Cast / CopperNO Foundation Insulation Interior / ExteriorNO Rough Grade 6 inch drop within 10 ft.NO Poly Under SlabYES6/11/19 poly under slab verified at garage only Smith, Mark (Inspector) Jun 11, 2019Page (2)