Loading...
HVAC EMS Calculator Page 1 of 14 RECEIVED EMS HVAC Load Calculator APR 1 6 2019 www.hvacloadcalculator.com TOWN OF QUEENSBURY ZONING OFFICE Date: Wed Apr 10 Loaded Document: gf info Welcome - GFOIL 2019 09:14am Company Info Client Information Company GF HEATING OIL LLC Name VICTOR BYE Preparer BRIAN NELSON Addressl 16 KNOLLS RD NORTH Phone (518) 792-2220 Address2 Email brian@gfheatingoil.com Address3 Phone (518) 583-2008 Email Date 10-Apr-2019 This HVAC load calculation has been performed using sound engineering principles as prescribed by Manual J eighth edition and ASHRAE Handbook of Fundamentals. Duct sizing has been performed as prescribed by Manual D. 1. Design Conditions(Temp. F) i Check If Using Celcius INDOOR OUTDOOR TEMP Front of West DIFF Building is Facing WINTER 70 -20 90 Total 4000 Sq.Ft SUMMER 65 95 30 Conditioned Area https://ems-residential.hvacloadcalculator.com/app/ 4/10/2019 EMS Calculator Page 2 of 14' 2. Summer Humidity Moderately 40 Grains Difference 3. How Tight is Structure Average-over 1500 Sq. Ft. Winter Summer Air/Changes/Hr. 0.7 0.35 4. Fireplace Evaluation Number Evaluation CFM 2 N., Semi-tight 20 5. Number of Occupants generally equals number of bedrooms + 4 1 Overhang Characteristics Enter air meaSurements decimally ft1,0to.em 4 = 5 Example-2 ft.8 in =2 7 ff EAST WEST S/SE/SW N/NE/NW https://ems-residential.hvacloadcalculator.com/app/ 4/10/2019 . EMS Calculator Page 3 of 14 Distance of OH from top of 1.6 1.6 1.6 1.6 window (A) Length of overhang (B) 1.6 1.6 1.6 1.6 Total linear ft. across top 20 2 14 10 of windows located below overhang Solar GainThrough Glass ..i]Check this box if using manufacturer specifications and enter the latitude, U-value and SHGC Latitude 45 U-Value SHGC Facing Area(sq ft) Type Glass HTM Unshaded Shaded BTUH North or 40 Double v 24.00 0 76 1,820 Shaded NE/NW 0 v 0.00 0 0 0 South 84 Double v 40.00 48 36 1,926 SE/SW 0 v 0.00 0 0 0 East 116 Double v 75.00 116 0 8,700 West 4 Double v 75.00 4 0 300 Does glass have reflective No \, 1 12,747 coating? Skylight 0 Clear v 150 0 Total 12,747 Solar Gain https://ems-residential.hvacloadcalculator.com/app/ 4/10/2019 EMS Calculator Page 4 of 14` DUCTS OR PIPES Location(Heating) Conditioned ar v Duct 0.00 Loss Location(Cooling) Conditioned ar v Duct 0.00 Gain Duct/Pipe Insulation Duct Leakage Area of Attic or 0 Floor Where Duct is Located Attic Temperature (If ducts located in attic) Load Calculation Elements of Area or Insulation/R-value U-Value Heat Heat Latent Load Lin. Ft Loss Gain Btuh Btuh Btuh Solar Gain 12,747 from Glass Gross Wall 184C Glass 1 244 Double 0.56 12,298 Skylight 0 v 0.00 0 Doors 2 Insulated or'v 0.40 72 24 Net Wall 1,594 R-19 v 0.07 9,755 3,252 Ceiling 229E R-30 v 0.03 6,612 3,306 https://ems-residential.hvacloadcalculator.com/app/ 4/10/2019 ' EMS Calculator Page 5 of 14 Floor Over Crawl 0 No Insulation v 0.37 0 0 or Unheated Basement Open-Beach 0 �, 0.00 0 0 House Above Carport Slab On 0 No Insulation v 0.80 0 0 Grade - enter-linear ft Infiltration- 160C 20,460 3,080 Enter cubic-ft of building People 920 800 Appliances L 3 Enter Value Sub Total 49,197 23,332 Duct Loss/Gain 0 0 1,471 Total Sensible Load 49,197 23,332 Latent Load 2,539 Total Latent Load 4,810 SUMMARY Heating Load Sensible Cooling Latent Cooling Total Cooling Load *Nominal Tons 49,197 23,332 4,810 28,141 2.59 OUTDOOR AIR FLOW RATE 70 https://ems-residential.hvacloadcalculator.com/app/ 4/10/2019 EMS Calculator Page 6 of 14 , * CAUTION - The cooling capacity of the air conditioner must meet both, sensible and latent loads. It is recommended a Manual S calculation be performed. Using manufacturer's specs. The nominal tons assume .75 S/T ratio at the chosen outdoor design temperature. Summary Including Basement Heating Load Sensible Cooling Latent Cooling Total Cooling Load Nominal Tons 71,660 28,822 7,283 36,106 3.20 Whole House (Block Load) Completed Scroll to top For Additional Options Solar Gain Through Glass 1:?Check if Using Manufacturer specs Latitude 40 U-Value SHGC Facing Area(sq ft) Type Glass HTM BTUH North or 16 Double v 24.00 384 Shaded NE/NW 0 v 0.00 0 South 16 Single v 50.00 800 SE/SW 0 v 0.00 0 East 66 v 0.00 0 West 0 v 0.00 0 Does glass have reflective coating? No „ 1,184 https://ems-residential.hvacloadcalculator.com/app/ 4/10/2019 • EMS Calculator Page 7 of 14 Total Solar 1,184 Gain Basement Load Calculation Elements of Area Insulation/R-value U-Value Heat Heat Gain Latent Load or Lin. Loss Btuh Btuh Ft Btuh Solar Gain 1,184.00 From Glass Gross Wall 510 Above Grade Glass 1 98 Double v 0.56 4,939 Doors 1 Insulated or' 0.40 36 12 Net Wall- 411 R-19 v 0.06 2,219 740 Above Grade Wall Below 102 R-19 0.03 2,754 918 Grade Ceiling 0 R-21 , 0.04 0 0 Floor 213 0.02 4,603 4,603 Infiltration- 191 7,911 2,637 Enter cubic-ft of building People 0 0 0 Appliances 0 Total Sensible Load 22,463 5,491 Latent Load 2,174 Total Latent Load 2,474 https://ems-residential.hvacloadcalculator.com/app/ 4/10/2019 EMS Calculator Page 8 cA 14 , Basement Summary Heating Load Sensible Cooling Latent Cooling Total Cooling Load *Nominal Tons 22,463 5,491 2,474 7,665 0.61 * CAUTION - The cooling capacity of the air conditioner must meet both, sensible and latent loads. It is recommended a Manual S calculation be performed. Using manufacturer's specs. The nominal tons assume .75 SIT ratio at the chosen outdoor design temperature. Room by Room Load Calculation Total House Total House System CFM Cooling Heating Heat Loss Sensible Heat 0 0 Gain 71,660 28,822 Room HeatLoss HeatGain CFM_Heat CFM_Cool ♦Add-Room :35Check-Calculations-When-Completed auto- 22,463 5,491 0 0 basement Totals: 22,463 5,491 0 0 Percent Of Original: 31% 19% Round to Rectangle Conversion Calculator(Optional) Enter Round Side A (Inches) Side B (Inches) Diameter 0 0 +»»w....ur..wwuww»..ue+.....:..wNw,..»». - ...,..a... ...... ................... m,wr�..... .... »�+�w.w.wrw..w.»w ee»wu nw R https://ems-residential.hvacloadcalculator.com/app/ 4/10/2019 EMS Calculator Page 9 of 14 Duct Sizing Use heating or cooling Type of duct material cfm Determine Friction Rate (see instructions) Total measured length of duct 0 Total equivalent length of fittings 0 Available static pressure for duct 0 Enter Friction Rate: Li Calculate Friction Rate Supply Trunk or branch cfm duct air dia vel First section off AH 0 1st reduction or branch 0 2nd reduction or branch 0 3rd reduction or branch 0 4th reduction or branch 0 5th reduction or branch 0 Return Trunk or branch cfm duct air dia vel First section off AH 0 1st reduction or branch 0 2nd reduction or branch 0 3rd reduction or branch 0 https://ems-residential.hvacloadcalculator.com/app/ 4/10/2019 EMS Calculator Page 10 of 14 4th reduction or branch 0 5th reduction or branch 0 Basement supply and return 0 trunk Room Runs cfm no of outlet duct air outlets cfm dia vel auto-basement 0 0 Duct Sizing Completed Scroll to top For Additional Options Equipment selection as per Manual S Instructions: enter load, weather and manufacture's data in white cells Auto Complete BTUH Total Heat Loss 71660 Design Outdoor Indoor Conditions Total Heat Gain 35806 -20 70 Sensible Heat 28822 95 65 Gain Latent Heat Gain 6,983 ID Design RH 50%, 63F WB Sensible/Total 0.80 Altitude 344 Ratio target ctg Temp. 19 Predominantly Heating climat Drop Manufactures Equipment Specifications https://ems-residential.hvacloadcalculator.com/app/ 4/10/2019 • EMS Calculator Page 11 of 14 Equipment Manufacturer Model BTUH Total Sensible Latent No output cooling BTUH BTUH (heating) BTUH @ OD design temp Furnace RUUD R9 115000 ;2-9'°JCPA(,S 9'1-t11g5 A Boiler 0 0 Heat Pump RUUD EX 48000 4800C 0 or Air -eft / LA,l(1►i` Conditioner Evaporator RUUD RC Q L S Coil Air Handler Total 113417.6 47752.32 47752.32 0 Capacity with Altitude Correction Selected OVERSIZED OVERSIZED OK UNDERSIZED Equipment Size Heating CFM Cooling CFM External Static Pressure of (recommended) Blower 2000 2,285 0 Available static presure for Supplemental heat needed for heat duct system pump Blower ext. 0 HP capacity @ 47F 0 static press Coil press HP capacity ® 17F 0 0 drop* https://ems-residential.hvacloadcalculator.com/app/ 4/10/2019 EMS Calculator Page 12 of 14' • Filter press 0 HP capacity ® 0 drop* ODDT Register press 0 BTUH 71,660 drop supplemental heat Grille Pressure 0 KW supplemental 21 Drop heat Other 0 Other 0 Other 0 Available SP 0 for duct Equipment Size Limits Air conditioner- Furnace Boiler heat Pump Cool Climate Heat Climate output output Maximum 41,177 44,757 100,324 100,324 Size Selected OVERSIZED OVERSIZED OVERSIZED OVERSIZED Size Energy Cost Analysis Heat Loss 71,660.26 Heating Degree Days 7200 Heat Gain 35,805.76 Cooling Degree Days 500 Summer Design 95 Summer Design Temp 30 Temp Diff https://ems-residential.hvacloadcalculator.com/app/ 4/10/2019 FINIS Calculator Page 13 of 14 Winter Design -20 Winter Design Temp 90 Temp Diff System #1 (Old or less efficient system) Efficiency Fuel Cost Air Conditioning 0 0 Heating 0 0 0.00 Total annual operating cost of system 1 System #2 (Old or less efficient system) Efficiency Fuel Cost Air Conditioning 0 0 Heating 0 0 0.00 Total annual operating cost of system 1 PAYBACK AND ROI Cost of new or more efficient system 0 Cost of less efficient system 0 Rebates or credits 0 Additional Investment 0.00 Yearly Savings https://ems-residential.hvacloadealculator.com/app/ 4/10/2019 L/FEEREAT • lb V.r)Oi 15 (2-0 W.0 r 41 111000R AIR SYSTEMS n'q`-eel��7�G &(� t 2 O 41- Sizing and Se lecting a Lifebreath HRV or ERV Step 1:Follow these general guidelines to determine the best HRV or ERV for your application . Option 1:Size your Residential unit by Air Exchange(ac/hr)Method Step 1 Step 2 2400sqft (L x W)with 9'(H) ceiling ac/hr=(Total Cubic Volume x.35)/60 Cubic volume=(L x W x H) or(2400 x 9)x.35/60min = 126cfm *In all cases local and all other codes requirements must be followed Option 2:Size your Residential unit using ASHRAE 62.2(Minimum requirement) Residential Ventilation Air Requirements(CFM/Bedrooms) Sizing A9-RAE622TABLE 4.1a . 1 2 q3 4 5 Floor Area Sq.ft. <500 30 38 45 53 60 501-1000 45 53 60 68 75 1001-1500 60 68 75 83 90 1501-2000 75 83 90 98 105 2001-2500 90 98 105 113 120 2501-3000 105 113 120 128 135 3001-3500 120 128 135 143 150 C3501-4000 135 143 150 - 158 • 165 4001-5000 150 159 165 173 180 5000-5001 165 173 180 188 195 *In all cases local and all other codes requirements must be followed Size your Commercial unit—Note it's recommended a mechanical engineer always be consulted. Application Occupant CFM/Person CFM/SQFT Comments Density/1000sgft Retail Stores 15 10 Classroom 25-35 15 Varies with age Offices 5 10 Conference Rooms 50 15 Hair/Nail Salons 25 20 Do not Undersize Pet Shops 1 Physical Therapy 20 15 Bars/Lounges 100 10 Non-Smoking Health Clubs 40 20 Only 10/1000 in weight room *Swimming Pools 1-10 Varies greatly with temperature Places of Religion 120 5