Loading...
inspection 05222019INSPECTION WORKSHEET (BINS-002896-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0188-2019 Case Module:Permit Inspection Date:Wed May 22, 2019 Inspection Status:Partial Pass Inspector:John O'Brien Inspection Type:Building Foundation Job Address:Parcel Number:16 KNOLLS RD NORTH Queensbury, NY 12804 253.3-1-52 Contact Type Company Name Name Electrical Contractor GPS Contracting LLC Contractor JMR Irish Drywall Inc Applicant Prime Construction Services, LLC Granted Permission Bye, Victor Engineer Saratoga Engineering & Design Plumbing Contractor B & B Plumbing & Heating Contractor Denno Contracting LLC Contractor Prime Construction Services, LLC Primary Owner Bye, Victor Checklist Item Passed Comments Building Inspector Notes NO 5/22/19 Foundation Walls and Deck Footings Partial Approval. - Provide documentation from engineer stating the placement of the deck footing next to and 12" below the septic tank is ok. Provide detail w/ engineer's stamp. Locations: Front Porch foundation walls, covered deck Footings and East elevation foundation walls. May 22, 2019 Page (1) INSPECTION WORKSHEET (BINS-002896-2019) Checklist Item Passed Comments Footings YES 5/22/19 Foundation Walls and Deck Footings Partial Approval. - Provide documentation from engineer stating the placement of the deck footing next to and 12" below the septic tank is ok. Provide detail w/ engineer's stamp. Locations: Front Porch foundation walls, covered deck Footings and East elevation foundation walls. Piers NO Monolithic Slab NO Foundation / Wallpour YES 5/22/19 Foundation Walls and Deck Footings Partial Approval. - Provide documentation from engineer stating the placement of the deck footing next to and 12" below the septic tank is ok. Provide detail w/ engineer's stamp. Locations: Front Porch foundation walls, covered deck Footings and East elevation foundation walls. Reinforcement in Place YES 5/22/19 Foundation Walls and Deck Footings Partial Approval. - Provide documentation from engineer stating the placement of the deck footing next to and 12" below the septic tank is ok. Provide detail w/ engineer's stamp. Locations: Front Porch foundation walls, covered deck Footings and East elevation foundation walls. Foundation Dampproofing NO Foundation Waterproofing NO Footing Drain Daylight or Sump NO Footing Drain Stone - 12 inch width NO Footing Drain Stone - 6 inches above footing NO May 22, 2019 Page (2) INSPECTION WORKSHEET (BINS-002896-2019) Checklist Item Passed Comments Footing Drain stone - 6 mil poly NO Backfill Approval NO Plumbing Under Slab NO PVC / Cast / Copper NO Foundation Insulation Interior / Exterior NO Rough Grade 6 inch drop within 10 ft.NO Poly Under Slab NO May 22, 2019 Page (3) O'Brien, John (Inspector)