Loading...
inspection 04252019INSPECTION WORKSHEET (SEP-002141-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:SEP-0218-2019 Case Module:Permit Inspection Date:Thu Apr 25, 2019 Inspection Status:Passed Inspector:John O'Brien Inspection Type:Septic Job Address:Parcel Number:8 FERRISS DR Queensbury, NY 12804 301.15-1-21 Contact Type Company Name Name Primary Owner Manell, Richard Granted Permission Manell, Richard Contractor Sanitary Sewer Service Engineer Center, Tom Applicant Sanitary Sewer Service Checklist Item Passed Comments Building Inspector Notes YES 4/25/19 Septic System Approved Type of Water: Municipal / Well Water YES Municipal Absorbtion Fields: Total Length YES 95' Length of Each Trench YES 4@20' End looped Depth of Trenches YES 24"-30" Size of Stone YES #2 Building to Tank YES Existing 4" sch40 pvc Apr 25, 2019 Page (1) INSPECTION WORKSHEET (SEP-002141-2019) Checklist Item Passed Comments Tank to Distribution Box YES 4" sdr35 pvc Distribution box to Field / Pit YES 4" sdr35 pvc to 4" sdr35 pvc perforated End Cap YES End looped Foundation to Tank YES Existing 10' + Foundation to Absorption YES 21'-6" Location of system on property YES Rear right side System Use Status YES 4/25/19 Septic System Approved Apr 25, 2019 Page (2) O'Brien, John (Inspector)