inspection 04252019INSPECTION WORKSHEET (SEP-002141-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:SEP-0218-2019 Case Module:Permit
Inspection Date:Thu Apr 25, 2019 Inspection Status:Passed
Inspector:John O'Brien Inspection Type:Septic
Job Address:Parcel Number:8 FERRISS DR
Queensbury, NY 12804
301.15-1-21
Contact Type Company Name Name
Primary Owner Manell, Richard
Granted Permission Manell, Richard
Contractor Sanitary Sewer Service
Engineer Center, Tom
Applicant Sanitary Sewer Service
Checklist Item Passed Comments
Building Inspector Notes YES 4/25/19 Septic System Approved
Type of Water: Municipal / Well Water YES Municipal
Absorbtion Fields: Total Length YES 95'
Length of Each Trench YES 4@20' End looped
Depth of Trenches YES 24"-30"
Size of Stone YES #2
Building to Tank YES Existing 4" sch40 pvc
Apr 25, 2019 Page (1)
INSPECTION WORKSHEET (SEP-002141-2019)
Checklist Item Passed Comments
Tank to Distribution Box YES 4" sdr35 pvc
Distribution box to Field / Pit YES 4" sdr35 pvc to 4" sdr35 pvc perforated
End Cap YES End looped
Foundation to Tank YES Existing 10' +
Foundation to Absorption YES 21'-6"
Location of system on property YES Rear right side
System Use Status YES 4/25/19 Septic System Approved
Apr 25, 2019 Page (2)
O'Brien, John (Inspector)