Loading...
HVAC i . i ph--7 ......,. ...... 11 APR 18 2019 lij 31 Wooden Ln ovv cr 0 L3 s HVAC Load Calculations t5, !T) . .. . : for The Michaels Group _ I � Cr) 4-- U) 0 O t1) Mf) EN aliwalis; i_ N C.) O J ca E w O c V I-, aJ 00 =1 L. LL -., ,_..._ u YLV .2. .z, • HVAC LOADSN L'D200 N CD 00 ca 0 o Mo v >_ a r2M (n I I Prepared By: Nick Abrunza Appolo Heating 868 Burdeck St Schenectady Ny 12306 Friday,April 12, 2019 i 1 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. i -- -- --- - -- --- ---- --- _- -- - --- 31 Wooden Ln Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,In . Appolo Heating Inc. Schenectady,NY 12306 _ ___.Page 2 , , Project Report — General Project Information I Project Title: 31 Wooden Ln Designed By: The Michaels Group Project Date: Thursday,April 11, 2019 Client Name: The Michaels Group Company Name: Appolo Heating Company Representative: Nick Abrunza Company Address: 868 Burdeck St Company City: Schenectady Ny 12306 .g m Schenectady,.New York - _- Design Data Reference City: Building Orientation: Front door faces East Daily Temperature Range: Medium Latitude: 42 Degrees Elevation: 378 ft. Altitude Factor: 0.986 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 1 0.31 n/a n/a 70 n/a Summer: 87 72 49% 50% 75 30 Check Figures Total Building Supply CFM: 1,066 CFM Per Square ft.: 0.286 Square ft. of Room Area: 3,726 Square ft. Per Ton: 1,725 Volume (ft3): 31,673 Building Loads i Total Heating Required Including Ventilation Air: 54,365 Btuh 54.365 MBH Total Sensible Gain: 23,125 Btuh 89 % Total Latent Gain: 2,791 Btuh 11 % Total Cooling Required Including Ventilation Air: 25,916 Btuh 2.16 Tons(Based On Sensible+ Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\31 Wooden Ln.rh9 Friday, April 12, 2019, 10:31 AM r Rhvaco Residential Inc. Li h ._._ d — — el pmePann Inc. I Schenectady,eating 3 NY 12306 _ _ - ___ _ - - -_ .- - —_—__-_-- _--__ 9 - &Light Commercial HVAC Loads Elite Software Development, , Miscellaneous Report 1 System 1 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Difference Input Data Dry Bulb Wet Bulb Rel.Hum Rel.Hum Winter: 1 0.31 80% n/a 70 n/a Summer: 87 72 49% 50% 75 29.96 Duct Sizing Inputs ; Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 0 ft./min 0 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration Specified: 0.280 AC/hr 0.150 AC/hr 148 CFM 79 CFM Infiltration Actual: 0.280 AC/hr 0.150 AC/hr Above Grade Volume: X 31.673 Cu.ft. X 31.673 Cu.ft. 8,868 Cu.ft./hr 4,751 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 148 CFM 79 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration&Ventilation Sensible Gain Multiplier: 13.02 = (1.10 X 0.986 X 12.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 20.09 = (0.68 X 0.986 X 29.96 Grains Difference) Infiltration&Ventilation Sensible Loss Multiplier: 74.87 = (1.10 X 0.986 X 69.00 Winter Temp. Difference) Winter Infiltration Specified: 0.280 AC/hr(148 CFM), Construction:Average Summer Infiltration Specified: 0.150 AC/hr(79 CFM), Construction:Average C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\31 Wooden Ln.rh9 Friday,April 12, 2019, 10:31 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 1110 31 Wooden Ln Schenectady,NY 12306 Page 4 I: Load Preview Report • Neti a • Sys; SYsi SYs ft. i Seni La/ Ne� Sent Htg Clgf Acf.. Duct Scope TO /Ton Area Gain, Gain' Gain! Loss; Size .-____._.___ .----------__._- -----______�_._.__i--- CFM CFM CFMs Building 2.16 1,725 3,726 23,125 2,791 25,916 54,365 716 1,066 1,066 System 1 2.16 1,725 3,726 23,125 2,791 25,916 54,365 716 1,066 1,066 12x1E Zone 1 3,726 23,125 2,791 25,916 54,365 716 1,066 1,066 12x1E 1-Bedroom 2 195 2,191 527 2,718 4,422 58 101 101 1--7 2-Bath 1 56 874 24 898 1,041 14 40 40 1-5 3-Office 182 2,177 159 2,336 4,803 63 100 100 1--7 4-Foyer 56 983 36 1,019 1,290 17 45 45 1--5 _;___5-Dining- ---- --- -_ - _-------- -------- -------T69 T792 --71 1,869--3,385----4.5._._._-"83---83 -1--6 '--- ----- 6-Great Room 357 2,768 77 2,845 5,595 74 126 128 2--6 7-Breakfast 96 2,115 127 2,242 3,961 52 97 97 1-7 8-Kitchen 144 880 0 880 1,362 18 41 41 1-5 9-Mud Room 64 892 42 934 1,612 21 41 41 1-5 10-Hat 121 718 0 718 1,142 15 33 33 1-4 11-Master Suite 234 3,136 939 4,075 5,031 66 145 145 2-6 12-WIG 80 716 0 716 756 10 33 33 1-4 13-Master Bath 114 1,289 118 1,407 3,138 41 59 59 1-5 14-Basement 1,858 2,597 665 3,262 16,827 222 120 120 2-5 C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\31 Wooden Ln.rh9 Friday,April 12, 2019, 10:31 AM .., Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc: Appolo Heating Inc. 31 Wooden Ln 1, Schenectady NY 12306 : Page 5 I r Duct Size Preview 1 Room or Minimum Maximum Rough. Design SP1 Duct Duct Htg Clg Act Duct Surce Duct Name o Velocity Velocity Factor L/100 Los Velocity Length Flow Flow : Flow Size System 1 Supply Runouts Zone 1 1-Bedroom 2 Built-In 0 750 0.01 0.1 377.8 58 101 101 1- 2-Bath 1 Built-In 0 750 0.01 0.1 295.2 14 40 40 1-5 3-Office Built-In 0 750 0.01 0.1 375.3 63 100 100 1-- 4-Foyer Built-In 0 750 0.01 0.1 332.2 17 45 45 1--5 5-Dining Built-In 0 750 0.01 0.1 420.6 45 83 83 1-6 6-Great Room Built-In 0 750 0.01 0.1 324.8 74 128 128 2-. 7-Breakfast Built-In 0 750 0.01 0.1 364.7 52 97 97 1-- 8-Kitchen Built-In 0 750 0.01 0.1 297.2 18 41 41 1--5 9-Mud Room Built-In 0 750 0.01 0.1 301.3 21 41 41 1--5 10-Hall Built-In 0 750 0.01 0.1 379.2 15 33 33 1-, 11-Master Suite Built-In 0 750 0.01 0.1 368 66 145 145 2-6 12-WIC Built-In 0 750 0.01 0.1 377.8 10 33 33 1-4 13-Master Bath Built-In 0 750 0.01 0.1 435.5 41 59 59 1--5 14-Basement Built-In 0 750 0.01 0.1 438.8 222 120 120 2-5 Other Ducts in System 1 Supply Main Trunk Built-In 0 900 0.003 0.1 799.2 716 1,066 1,066 12x1: ' Summary System 1 Heating Flow: 716 Cooling Flow: 1066 C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\31 Wooden Ln.rh9 Friday,April 12, 2019, 10:31 AM a Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc Appolo Heating Inc. 31 Wooden Ln _Schenectady NY_12306 -_-__ - -- __- ---- - --------- Page 6 I Total Building Summary Loads Component Area Sen Lat Sen Total Description Quan Loss Gain Gain _ Gain_. Pella Vinyl: Glazing-Pella Vinyl, U-value 0.31, SHGC 0.28 232.2 4,968 0 3,294 3,294 Front Door: Door-Front Door Generic, U-value 0.19 21.8 285 0 95 95 Pella Slider: Door-Pella Slider, U-value 0.3 40.8 845 0 282 282 Fire Rated: Door-Fire Door Generic, U-value 0.28 20.4 394 0 131 131 !, 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud 1522.6 6,827 0 1,221 1,221 cavity, no board insulation, siding finish,wood studs, U-value 0.065 12E-0bm: Wall-Frame, R-19 insulation in 2 x 6 stud 1320 9,381 0 1,143 1,143 cavity,no board insulation,brick finish, metal studs, r--- -- U-value 0.103 16B-38: Roof/Ceiling-Under Attic with Insulation on Attic 1868 3,352 0 2,281 2,281 Floor(also use for Knee Walls and Partition Ceilings),Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal,Tar and Gravel or Membrane, R-38 insulation, U-value 0.026 19A-0cp: Floor-Over enclosed crawl space, No insulation 1633.8 12,493 0 2,173 2,173 on exposed walls, sealed or vented space, passive, no floor insulation, carpet or hardwood, U-value 0.295 19A-0tp: Floor-Over enclosed crawl space, No insulation 234.2 1,935 0 337 337 on exposed walls, sealed or vented space, passive, no floor insulation,tile or vinyl, U-value 0.368 21A-28: Floor-Basement, Concrete slab, any thickness, 2 1857.6 2,820 0 0 0 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 28'wide, U-value 0.022 Subtotals for structure: 43,300 0 10,957 10,957 People: 3 1,200 1,350 2,550 Equipment: 0 0 0 Lighting: 2870 9,787 9,787 Ductwork: 0 0 0 0 Infiltration:Winter CFM: 148, Summer CFM: 79 11,065 1,591 1,031 2,622 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Total Building Load Totals: 54,365 2,791 23,125 25,916 Check Figures Total Building Supply CFM: 1,066 CFM Per Square ft.: 0.286 Square ft. of Room Area: 3,726 Square ft. Per Ton: 1,725 Volume (ft3): 31,673 Building Loads Total Heating Required Including Ventilation Air: 54,365 Btuh 54.365 MBH Total Sensible Gain: 23,125 Btuh 89 % Total Latent Gain: 2,791 Btuh 11 ok Total Cooling Required Including Ventilation Air: 25,916 Btuh 2.16 Tons (Based On Sensible+Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\31 Wooden Ln.rh9 Friday, April 12, 2019, 10:31 AM F ' hvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc Appolo Heating Inc. 31 Wooden Ln Schenectady,NY 12306Paae 22 System , Room Load Summary J Htg Min Run Run CIg Cig Min Act Room Area Sens Htg Duct Duct Sens Lat CIg Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM_ ---Zone 1--- 1 Bedroom 2 195 4,422 58 1-7 378 2,191 527 101 101 2 Bath 1 56 1,041 14 1-5 295 874 24 40 40 3 Office 182 4,803 63 1-7 375 2,177 159 100 100 4 Foyer 56 1,290 17 1-5 332 983 36 45 45 5 Dining 169 3,385 45 1-6 421 1,792 77 83 83 6 Great Room 357 5,595 74 2-6 325 2,768 77 128 128 7 Breakfast 96-_ 3,961 52 1-7 365 2,115 127 97 97 8 Kitchen 144 1,362 18 1-5 297 880 0 41 41 9 Mud Room 64 1,612 21 1-5 301 892 42 41 41 10 Hall 121 1,142 15 1-4 379 718 0 33 33 11 Master Suite 234 5,031 66 2-6 368 3,136 939 145 145 12 WIC 80 756 10 1-4 378 716 0 33 33 13 Master Bath 114 3,138 41 1-5 435 1,289 118 59 59 14 Basement 1,858 16,827 222 2-5 439 2,597 665 120 120 System 1 total 3,726 54,365 716 23,125 2,791 1,066 1,066 System 1 Main Trunk Size: 12x16 in. Velocity: 799 ft./min Loss per 100 ft.: 0.094 in.wg Cooling System Summary Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 2.16 89%/11% 23,125 2,791 25,916 Actual: 2.73 75%/25% 24,600 8,200 32,800 Equipment Data Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: ML195UH070XP36B-* 13ACXN036-230** Indoor Model: C35-30B+TDR+TXV Brand: MERIT 90 MERIT 13ACX SERIES Description: Natural Gas or Propane Furnace Efficiency: 95 AFUE 13 SEER Sound: 0 0 Capacity: 64,000 Btuh 32,800 Btuh Sensible Capacity: n/a 24,600 Btuh Latent Capacity: n/a 8,200 Btuh AHRI Reference No.: n/a 8266991 i • J C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\31 Wooden Ln.rh9 Friday,April 12, 2019, 10:31 AM