ComCheck REVIEWED FOR
ENERGY CODE COMPLIANCE
COMcheck Software Vert' Fi m 3 y
* y CaA. co
Ar ) Envelope Compliance Certificate o
O
� L 3CD = o
Project Informationt.., [ 1 i -> a `D
Energy Code: 2015 IECC APR 19 2019 v Q
i °
7J
Project Title: New Restaurant Building - 0
Location: Glens Falls, New York TOWN OF OUEENSBURY
Climate Zone: 6a 1BUILDING&CODES p n
Project Type: New Construction a) n
Vertical Glazing/Wall Area: 3% e N
Co d Oiv CO
No
Construction Site: Owner/Agent: Designer/Contractor: -Pfl. C
State Route 149 Dale Baldwin Ethan P. Hall u) —, S)
Queensbury, NY 128041 Shake, Rattle&Roll Restaurant Rucinski Hall Architecture :, 7 ap
State Route 149 134 Dix Ave "''
Queensbury, NY 12804 Glens Falls, NY 12801
518-741-0268 -
Additional Efficiency Package(s) ephall@nycap.rr.com
Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations.
Building Area Floor Area FILE COPY
1-Dining: Family: Nonresidential 2665
Envelope Assemblies
Assembly Gross Area Cavity Cont. Proposed Budget U-
or R-Value R-Value U-Factor Factor)a)
Perimeter
Roof 1:Attic Roof with Wood Joists,[Bldg.Use 1 -Dining:Family] 2665 38.0 0.0 0.027 0.021
NORTH
Exterior Wall 1:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Dining:Family] 1315 21.0 3.6 0.049 0.051
Door 1:Insulated Metal,Swinging,[Bldg.Use 1 -Dining:Family] 21 --- 0.300 0.370
Door 2: Insulated Metal,Swinging,[Bldg.Use 1 -Dining:Family] 21 --- --- 0.300 0.370
Door 3: Insulated Metal,Swinging,[Bldg.Use 1 -Dining:Family] 21 --- --- 0.300 0.370
Basement Wall 1:Solid Concrete:8"Thickness,Normal Density, 516 --- 10.0 0.088 0.108
Furring:None,Wall Ht 8.9,Depth B.G.8.0,[Bldg.Use 1 -Dining:
Family]
Basement Wall 5:Solid Concrete:8"Thickness,Normal Density, 243 --- 10.0 0.088 0.108
Furring:None,Wall Ht 4.9,Depth B.G.4.0,[Bldg.Use 1 -Dining:
Family]
EAST
Exterior Wall 2:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Dining:Family] 789 21.0 3.6 0.049 0.051
Window 1:Metal Frame with Thermal Break:Fixed,Perf.Specs.: 40 --- --- 0.290 0.360
Product ID product label,SHGC 0.33,[Bldg.Use 1 -Dining:Family](b)
Basement Wall 2:Solid Concrete:8"Thickness,Normal Density, 250 --- 10.0 0.088 0.108
Furring:None,Wall Ht 8.9,Depth B.G.8.0,[Bldg.Use 1 -Dining:
Family]
Basement Wall 6:Solid Concrete:8"Thickness,Normal Density, 180 --- 10.0 0.088 0.108
Furring:None,Wall Ht 4.9,Depth B.G.4.0,[Bldg.Use 1 -Dining:
Family]
Project Title: New Restaurant Building Report date: 04/12/19
Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 1 of 18
Assembly Gross Area Cavity Cont. Proposed Budget U-
or R-Value R-Value U-Factor Factor(,)
Perimeter
SOUTH
Exterior Wall 3:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Dining:Family] 1315 21.0 3.6 0.049 0.051
Window 2:Metal Frame with Thermal Break:Fixed,Perf.Specs.: 90 --- --- 0.290 0.360
Product ID product label,SHGC 0.33,[Bldg.Use 1 -Dining:Family](b)
Door 4: Insulated Metal,Swinging,[Bldg.Use 1 -Dining:Family] 21 --- --- 0.300 0.370
Door 5:Insulated Metal,Swinging,[Bldg.Use 1 -Dining:Family] 21 --- --- 0.300 0.370
Door 6:Insulated Metal,Non-Swinging,[Bldg.Use 1 -Dining:Family] 32 --- --- 0.300 0.179
Door 7:Insulated Metal,Non-Swinging,[Bldg.Use 1 -Dining:Family] 32 --- --- 0.300 0.179
Basement Wall 3:Solid Concrete:8"Thickness,Normal Density, 516 --- 10.0 0.088 0.108
Furring:None,Wall Ht 8.9,Depth B.G.8.0,[Bldg.Use 1 -Dining:
Family]
Basement Wall 7:Solid Concrete:8"Thickness,Normal Density, 147 --- 10.0 0.088 0.108
Furring:None,Wall Ht 4.9,Depth B.G.4.0,[Bldg.Use 1 -Dining:
Family]
WEST
Exterior Wall 4:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Dining:Family] 789 21.0 3.6 0.049 0.051
Window 3:Metal Frame with Thermal Break:Fixed,Perf.Specs.: 18 --- --- 0.290 0.360
Product ID product label,SHGC 0.33,[Bldg.Use 1 -Dining:Family](b)
Door 8:Insulated Metal,Swinging,[Bldg.Use 1 -Dining:Family] 21 --- --- 0.300 0.370
Basement Wall 4:Solid Concrete:8"Thickness,Normal Density, 250 --- 10.0 0.088 0.108
Furring:None,Wall Ht 8.9,Depth B.G.8.0,[Bldg.Use 1 -Dining:
Family]
Basement Wall 8:Solid Concrete:8"Thickness,Normal Density, 59 --- 10.0 0.088 0.108
Furring:None,Wall Ht 4.9,Depth B.G.4.0,[Bldg.Use 1 -Dining:
Family]
(a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements.
(b)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.
Envelope PASSES: Design 8% better than code
Envelope Compliance Statement
Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application.The proposed envelope systems have been
designed to meet the 2015 IECC requirements in COMcheck Ver ion 4.1.1. and to mpl with any applicable mandatory
requirements listed in the Inspection Checklist.
Ethan P. Hall-Architect l2,4,020/1
Name-Title Sig re Date
Project Title: New Restaurant Building Report date: 04/12/19
Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 2 of 18
A( COMcheck Software Version 4.1.1.0
1 Interior Lighting Compliance Certificate
Project Information
Energy Code: 2015 IECC
Project Title: New Restaurant Building
Project Type: New Construction
Construction Site: Owner/Agent: Designer/Contractor:
State Route 149 Dale Baldwin Ethan P. Hall
Queensbury, NY 128041 Shake, Rattle&Roll Restaurant Rucinski Hall Architecture
State Route 149 134 Dix Ave
Queensbury, NY 12804 Glens Falls, NY 12801
518-741-0268
Additional Efficiency Package(s) ephall@nycap.rr.com
Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations.
Allowed Interior Lighting Power
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts/ft2 (B X C)
1-Common Space Types:Dining Area-Family Restaurant 2100 0.80 1680
2-Common Space Types:Food Preparation 565 1.09 616
Total Allowed Watts= 2296
Proposed Interior Lighting Power
A B C D E
Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
1-Common Space Types:Dining Area-Family Restaurant
LED 1:LED Linear 17W: 1 34 32 1088
2-Common Space Types:Food Preparation
LED 2:LED PAR 15W: 1 25 32 800
Total Proposed Watts= 1888
Interior Lighting PASSES: Design 18% better than code
Interior Lighting Compliance Statement
Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been
designed to meet the 2015 IECC requirements in COMcheck Ver ion 4.1.1. nd t mpl with any applicable mandatory
requirements listed in the Inspection Checklist.
Ethan P. Hall-Architect 401.�oe9
Name-Title Sig re Date
Project Title: New Restaurant Building Report date: 04/12/19
Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 3 of 18
\fiCOMcheck Software Version 4.1.1.0
l Exterior Lighting Compliance Certificate
Project Information
Energy Code: 2015 IECC
Project Title: New Restaurant Building
Project Type: New Construction
Exterior Lighting Zone 2(Neighborhood business district)
Construction Site: Owner/Agent: Designer/Contractor:
State Route 149 Dale Baldwin Ethan P. Hall
Queensbury, NY 128041 Shake, Rattle&Roll Restaurant Rucinski Hall Architecture
State Route 149 134 Dix Ave
Queensbury, NY 12804 Glens Falls, NY 12801
518-741-0268
ephall@nycap.rr.com
Allowed Exterior Lighting Power
A B C D E
Area/Surface Category Quantity Allowed Tradable Allowed Watts
Watts/Unit Wattage (B X C)
Parking area 6 ft2 0.06 Yes 0
Entry canopy 5 ft2 0.25 Yes 1
Total Tradable Watts(a)= 2
Total Allowed Watts= 2
Total Allowed Supplemental Watts(b)= 600
(a)Wattage tradeoffs are only allowed between tradable areas/surfaces.
(b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces.
Proposed Exterior Lighting Power
A B C D E
Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
Parking area (6 ft2):Tradable Wattage
LED 3:LED Roadway-Parking Unit 54W: 2 6 64 384
Entry canopy(5 ft2):Tradable Wattage
LED 4:LED PAR 17W: 1 5 32 160
Total Tradable Proposed Watts= 544
Exterior Lighting PASSES: Design 10% better than code
Exterior Lighting Compliance Statement
Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application.The proposed exterior lighting systems have been
designed to meet the 2015 IECC requirements in COMcheck Version 4.1. 0 and com with any applicable mandatory
requirements listed in the Inspection Checklist. //��,,//�� /J
Ethan P. Hall-Architect • /2 AI2 Zay
Name-Title S ature Date
Project Title: New Restaurant Building Report date: 04/12/19
Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 4 of 18
NfiCOMcheck Software Version 4.1.1.0
l Mechanical Compliance Certificate
Project Information
Energy Code: 2015 IECC
Project Title: New Restaurant Building
Location: Glens Falls, New York
Climate Zone: 6a
Project Type: New Construction
Construction Site: Owner/Agent: Designer/Contractor:
State Route 149 Dale Baldwin Ethan P. Hall
Queensbury, NY 128041 Shake, Rattle&Roll Restaurant Rucinski Hall Architecture
State Route 149 134 Dix Ave
Queensbury, NY 12804 Glens Falls, NY 12801
518-741-0268
Additional Efficiency Package(s) ephall@nycap.rr.com
Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations.
Mechanical Systems List
Quantity System Type&Description
1 HVAC System 1 (Single Zone):
Heating: 1 each-Central Furnace,Gas,Capacity=65 kBtu/h
Proposed Efficiency=93.00%Et,Required Efficiency: 80.00%Et or 78%AFUE
Cooling: 1 each-Field-Assembled DX System,Capacity=45 kBtu/h,Air-Cooled Condenser,Air Economizer
No minimum efficiency requirement applies
Fan System: FAN SYSTEM 1 --Compliance(Motor nameplate HP method):Passes
Fans:
FAN 1 Supply,Single-Zone VAV, 1400 CFM,0.5 motor nameplate hp,0.0 fan efficiency grade
Mechanical Compliance Statement
Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans,
specifications,and other calculations submitted with this permit application.The proposed mechanical systems have been
designed to meet the 2015 IECC requirements in COMcheck V- '+ 4.1.1.0 d to co ly wi any applicable mandatory
requirements listed in the Inspection Checklist. - / ,/
Ethan P. Hall-Architect '� 441 2e/s7
Name-Title Sign- ure Date
Project Title: New Restaurant Building Report date: 04/12/19
Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 5 of 18
COMcheck Software Version 4.1.1.0
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 100.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
Plan Review Complies? Comments/Assumptions
& Req.ID
C103.2 Plans and/or specifications provide all ❑Complies Requirement will be met.
[PR1]1 information with which compliance ❑Does Not
can be determined for the building ❑Not Observable Location on plans/spec:A-1
envelope and document where
exceptions to the standard are ;❑Not Applicable
claimed.
C103.2 Plans,specifications,and/or ❑Complies Requirement will be met.
[PR2]i calculations provide all information ;❑Does Not
with which compliance can be ❑Not Observable Location on plans/spec:A-1
determined for the mechanical
systems and equipment and DNot Applicable
document where exceptions to the
standard are claimed. Load
calculations per acceptable
engineering standards and
handbooks.
C103.2 Plans,specifications,and/or ❑Complies Requirement will be met.
[PR4]i calculations provide all information ❑Does Not
with which compliance can be ['Not Observable Location on plans/spec:A-1
determined for the interior lighting
and electrical systems and equipment ❑Not Applicable
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations,wattage of:
bulbs and ballasts,transformers and
control devices.
C103.2 Plans,specifications,and/or ❑Complies Requirement will be met.
[PR8]1 calculations provide all information ❑Does Not
with which compliance can be [Not Observable Location on plans/spec:A-1
determined for the exterior lighting
and electrical systems and equipment ❑Not Applicable
and document where exceptions to
the standard are claimed. Information
provided should include exterior
lighting power calculations,wattage of
bulbs and ballasts,transformers and
control devices.
C402.4.1 The vertical fenestration area <= 30 ❑Complies :Requirement will be met.
[PR10]i percent of the gross above-grade wall ❑Does Not
area. Location on plans/spec:A-1
❑Not Observable
❑Not Applicable
C402.4.1 The skylight area <= 3 percent of the ❑Complies Requirement will be met.
[PR11]i gross roof area. ❑Does Not
❑Not Observable Location on plans/spec:A-1
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: New Restaurant Building Report date: 04/12/19
Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 6 of 18
Section
Plan Review Complies? Comments/Assumptions
&Req.ID
C406 Plans, specifications,and/or ❑Complies Requirement will be met.
[PR9]1 calculations provide all information ❑Does Not
with which compliance can be ['Not Observable Location on plans/spec:A-1
determined for the additional energy .
efficiency package options. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) I, 3 iLow Impact(Tier 3)
Project Title: New Restaurant Building Report date: 04/12/19
Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 7 of 18
Section
Footing/Foundation Inspection Complies? Comments/Assumptions
& Req.ID
C303.2 Below-grade wall insulation installed ❑Complies Requirement will be met.
[FO2]2 per manufacturer's instructions. ❑Does Not
"Not Observable,Location on plans/spec:A-1
ONot Applicable
C303.2.1 Exterior insulation protected against DComplies Requirement will be met.
[FO6]1 damage,sunlight, moisture,wind, ❑Does Not
landscaping and equipment
maintenance activities. Not Observable
❑Not Applicable
C402.1.4 Below-grade wall insulation R-value. ❑Complies See the Envelope Assemblies table for values.
[FO1]2 ❑Does Not
['Not Observable
❑Not Applicable
C403.2.4. Snow/ice melting system sensors for ❑Complies Exception: Requirement does not apply.
5, future connection to controls.Freeze Does Not
C403.2.4. protection systems have automatic
6 controls installed. ❑Not Observable
[FO9]3 ❑Not Applicable
Additional Comments/Assumptions:
LlJHigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 [Low Impact(Tier 3)
Project Title: New Restaurant Building Report date: 04/12/19
Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 8 of 18
Section
# Framing/Rough-In Inspection Complies? Comments/Assumptions
& Req.ID
C303.1.3 Fenestration products rated in ❑Complies Requirement will be met.
[FR12]2 accordance with NFRC. ❑Does Not
❑Not Observable Location on plans/spec:A-1
❑Not Applicable
C303.1.3 Fenestration products are certified as ❑Complies Requirement will be met.
[FRi3]1 to performance labels or certificates ❑Does Not
provided. Location on plans/spec:A-i
['Not Observable
❑Not Applicable
C402.4.3 Vertical fenestration SHGC value. ❑Complies See the Envelope Assemblies table for values.
[FR10]1 ❑Does Not
❑Not Observable
❑Not Applicable
C402.4.3, Vertical fenestration U-Factor. ❑Complies See the Envelope Assemblies table for values.
C402.4.3. ElDoes Not
4
[FR8]1 ❑Not Observable
❑Not Applicable
C402.4.4 U-factor of opaque doors associated '❑Complies See the Envelope Assemblies table for values.
[FR14]2 with the building thermal envelope ❑Does Not
meets requirements.
❑Not Observable
❑Not Applicable
C402.5.7 Vestibules are installed on all building ❑Complies Requirement will be met.
[FR17]3 entrances. Doors have self-closing ❑Does Not
devices. Location on plans/spec:A-1
❑Not Observable'
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: New Restaurant Building Report date: 04/12/19
Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 9 of 18
Section
# Plumbing Rough-In Inspection Complies? Comments/Assumptions
& Req.ID
C404.5, Heated water supply piping conforms ❑Complies Exception: Requirement does not apply.
C404.5.1, to pipe length and volume ❑Does Not
C404.5.2 requirements. Refer to section details.[PL6]3 ❑Not Observable
❑Not Applicable
C404.6.3 Pumps that circulate water between a ❑Complies Exception: Requirement does not apply.
[PL7]3 heater and storage tank have controls ❑Does Not
that limit operation from startup to
<= 5 minutes after end of heating ❑Not Observable
cycle. ❑Not Applicable
C404.7 Water distribution system that pumps ❑Complies Exception: Requirement does not apply.
[PL8]3 water from a heated-water supply ❑Does Not
pipe back to the heated-water source
through a cold-water supply pipe is a ❑Not Observable
demand recirculation water system. ❑Not Applicable
Pumps within this system have
controls that start the pump upon
receiving a signal from the action of a
user of a fixture or appliance and
limits the temperature of the water
entering the cold-water piping to
104°F.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 12 {Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: New Restaurant Building Report date: 04/12/19
Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle& Roll.cck Page 10 of 18
Section
# Mechanical Rough-In Inspection Complies? Comments/Assumptions
& Req.ID
C402.2.6 Thermally ineffective panel surfaces of❑Complies Exception: Requirement does not apply.
[ME41]3 sensible heating panels have ❑Does Not
insulation >= R-3.5. [Not Observable
❑Not Applicable
C402.5.5, Stair and elevator shaft vents have ❑Complies Exception: Requirement does not apply.
C403.2.4. motorized dampers that automatically ❑Does Not
3[MEWclose. ['Not Observable
❑Not Applicable
C402.5.5, Outdoor air and exhaust systems have!❑Complies Requirement will be met.
C403.2.4. motorized dampers that automatically ❑Does Not
3 shut when not in use and meet Location on plans/spec:A-1
[ME58]3 maximum leakage rates.Check ENot Observable
gravity dampers where allowed. ❑Not Applicable
C403.2.13 Unenclosed spaces that are heated ❑Complies Exception: Requirement does not apply.
[ME71]2 use only radiant heat. ElDoes Not
❑Not Observable
❑Not Applicable
C403.2.3 HVAC equipment efficiency verified. ❑Complies See the Mechanical Systems list for values.
[ME55]2 ❑Does Not
❑Not Observable
❑Not Applicable
C403.2.6. 'Demand control ventilation provided ❑Complies Exception: Requirement does not apply.
1 for spaces>500 ft2 and >25 ❑Does Not
[ME59]1 people/1000 ft2 occupant density and
served by systems with air side ['Not Observable
economizer,auto modulating outside ❑Not Applicable
air damper control, or design airflow
>3,000 cfm.
C403.2.6. Enclosed parking garage ventilation '❑Complies Exception: Requirement does not apply.
2 has automatic contaminant detection ❑Does Not
[ME115]3 and capacity to stage or modulate
fans to 50%or less of design capacity. ['Not Observable'
❑Not Applicable
C403.2.7 Exhaust air energy recovery on ❑Complies Exception: Requirement does not apply.
[ME57]1 systems meeting Table C403.2.7(1) ❑Does Not
and C403.2.7(2). ❑Not Observable
❑Not Applicable
C403.2.8 Kitchen exhaust systems comply with ❑Complies Requirement will be met.
[ME116]3 °replacement air and conditioned ODoes Not
supply air limitations, and satisfy hood Location on plans/spec:A-1
rating requirements and maximum ❑Not Observable
exhaust rate criteria. Observable,__,
Applicable
C403.2.9 HVAC ducts and plenums insulated. ❑Complies Requirement will be met.
[ME60]2 Where ducts or plenums are installed !❑Does Not
in or under a slab,verification may Location on plans/spec:A-1
need to occur during Foundation Not Observable
Inspection. ❑Not Applicable
C403.2.9 Ducts and plenums sealed based on ❑Complies Requirement will be met.
[ME10]2 static pressure and location. ❑Does Not
❑Not Observable Location on plans/spec:A-1
❑Not Applicable
C403.2.9. Ductwork operating >3 in.water ❑Complies Exception: Requirement does not apply.
1.3 column requires air leakage testing. ❑Does Not
[ME11]3 ❑Not Observable
❑Not Applicable
1 IHigh Impact(Tier 1) I 2 j Medium Impact(Tier 2) 3 I Low Impact(Tier 3)
Project Title: New Restaurant Building Report date: 04/12/19
Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 11 of 18
Section
# Mechanical Rough-In Inspection Complies? Comments/Assumptions
& Req.ID
C403.4.4. Multiple zone VAV systems with DDC ❑Complies Exception: Requirement does not apply.
6 of individual zone boxes have static ❑Does Not
[ME110]3 pressure setpoint reset controls. See the Mechanical Systems list for values.
❑Not Observable
❑Not Applicable
C408.2.2. Air outlets and zone terminal devices ;❑Complies Exception: Requirement does not apply.
1 have means for air balancing. ❑Does Not
[ME53]3 ❑Not Observable
❑Not Applicable
C403.5, Refrigerated display cases, walk-in ❑Complies Exception: Requirement does not apply.
C403.5.1, coolers or walk-in freezers served by ODoes Not
C403.5.2 remote compressors and remote
[ME123]3 condensers not located in a ❑Not Observable
condensing unit, have fan-powered ❑Not Applicable
condensers that comply with Sections
C403.5.1 and refrigeration compressor
systems that comply with C403.5.2..
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 I Low Impact(Tier 3) I
Project Title: New Restaurant Building Report date: 04/12/19
Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 12 of 18
Section
# Rough-In Electrical Inspection Complies? Comments/Assumptions
&Req.ID
C405.2.1 Lighting controls installed to uniformly ❑Complies Requirement will be met.
[ELi5]1 reduce the lighting load by at least ❑Does Not
50%. Location on plans/spec:A-1
❑Not Observable
❑Not Applicable
C405.2.1 Occupancy sensors installed in ❑Complies Requirement will be met.
[ELi8]1 required spaces. ❑Does Not
❑Not Observable Location on plans/spec:A-1
❑Not Applicable
C405.2.1, Independent lighting controls installed ❑Complies Requirement will be met.
C405.2.2. per approved lighting plans and all ❑Does Not
3 manual controls readily accessible and Location on plans/spec:A-1
[EL23]2 visible to occupants. ❑Not Observable
❑Not Applicable
C405.2.2. Automatic controls to shut off all ❑Complies Requirement will be met.
1 building lighting installed in all Does Not
[EL2212 buildings. Location on plans/spec:A-1
['Not Observable
❑Not Applicable
C405.2.3 Daylight zones provided with ❑Complies Exception: Requirement does not apply.
[ELi6]2 individual controls that control the ❑Does Not
lights independent of general area
lighting. ❑Not Observable
!❑Not Applicable
C405.2.3, Primary sidelighted areas are ;❑Complies Exception: Requirement does not apply.
C405.2.3. equipped with required lighting '❑Does Not
1, controls.
C405.2.3. ❑Not Observable
2 ❑Not Applicable
[EL20]1
C405.2.3, Enclosed spaces with daylight area ElComplies Exception: Requirement does not apply.
C405.2.3. under skylights and rooftop monitors ❑Does Not
1, are equipped with required lighting
C405.2.3. controls. ❑Not Observable
3 ❑Not Applicable
[EL21]1
C405.2.4 Separate lighting control devices for ❑Complies Requirement will be met.
[EL4]1 specific uses installed per approved ❑Does Not
lighting plans. Location on plans/spec:A-1
['Not Observable
❑Not Applicable
C405.2.4 Additional interior lighting power ❑Complies Requirement will be met.
[EL8]1 allowed for special functions per the ❑Does Not
approved lighting plans and is ❑Not Observable Location on plans/spec:A-1
automatically controlled and
separated from general lighting. ❑Not Applicable
C405.2.5 Automatic lighting controls for exterior'❑Complies Requirement will be met.
[EL25pull lighting installed.Controls will be ❑Does Not
daylight controlled,set based on Location on plans/spec:A-1
business operation time-of-day,or ❑Not Observable
reduce connected lighting > 30%. ❑Not Applicable
C405.3 Exit signs do not exceed 5 watts per ❑Complies Requirement will be met.
[EL6]1 face. ❑Does Not
❑Not Observable Location on plans/spec:A-1
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) I 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: New Restaurant Building Report date: 04/12/19
Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 13 of 18
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: New Restaurant Building Report date: 04/12/19
Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 14 of 18
Section
# Insulation Inspection Complies? Comments/Assumptions
& Req.ID
C303.1 Roof insulation installed per ❑Complies Requirement will be met.
[IN3]1 manufacturer's instructions. Blown or ❑Does Not
poured loose-fill insulation is installed ['Not Observable Location on plans/spec:A-1
only where the roof slope is<=3 in
12. ONot Applicable
C303.1 Building envelope insulation is labeled ❑Complies Requirement will be met.
[IN10]2 with R-value or insulation certificate ❑Does Not
providing R-value and other relevant
data. ONot Observable
ONot Applicable
C303.2 Above-grade wall insulation installed ❑Complies Requirement will be met.
[IN7]1 per manufacturer's instructions. ❑Does Not
DNot Observable!Location on plans/spec:A-i
ONot Applicable
C303.2.1 Exterior insulation is protected from ❑Complies Exception: Requirement does not apply.
[IN14]2 damage with a protective material. ❑Does Not
Verification for exposed foundation
insulation may need to occur during ONot Observable
Foundation Inspection. ONot Applicable
C402.1.3 Non-swinging opaque doors have R- ❑Complies Requirement will be met.
[IN19]3 4.75 insulation. Does Not
['Not Observable Location on plans/spec:A-i
ONot Applicable
C402.2.1 'Insulation intended to meet the roof ❑Complies Requirement will be met.
[IN17]3 insulation requirements cannot be ❑Does Not
installed on top of a suspended Location on plans/spec:A-1
ceiling. Mark this requirement ONot Observable
compliant if insulation is installed ONot Applicable
accordingly.
C402.2.3 Above-grade wall insulation R-value. ❑Complies See the Envelope Assemblies table for values.
[IN6]1 ❑Does Not
['Not Observable'.
ONot Applicable
C402.2.6 Radiant panels and associated DComplies Exception: Requirement does not apply.
[IN18]3 components, designed for heat ❑Does Not
transfer from the panel surfaces to the
occupants or indoor space are ONot Observable
insulated with a minimum of R-3.5. ONot Applicable
C402.2.2 Roof R-value. For some ceiling ❑Complies See the Envelope Assemblies table for values.
[IN2]1 systems,verification may need to ❑Does Not
occur during Framing Inspection.
['Not Observable
ONot Applicable
C402.5.1. All sources of air leakage in the ❑Complies Requirement will be met.
1 building thermal envelope are sealed, ODoes Not
[INi]1 caulked, gasketed,weather stripped ONot Observable Location on plans/spec:A-1
or wrapped with moisture vapor-
permeable wrapping material to ONot Applicable
minimize air leakage.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 tMedium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: New Restaurant Building Report date: 04/12/19
Data filename: Y:\Baldwin, Dale\Shake Rattle and RoII\Shake-Rattle&Roll.cck Page 15 of 18
Section
# Final Inspection Complies? Comments/Assumptions
& Req.ID
C303.3, Furnished O&M instructions for DComplies Requirement will be met.
C408.2.5. systems and equipment to the ❑Does Not
2 3 building owner or designated ❑Not Observable
[FI17] representative.
❑Not Applicable
C303.3, Furnished O&M manuals for HVAC DComplies Requirement will be met.
C408.2.5. systems within 90 days of system ❑Does Not
3 acceptance.
[FI8]3 ❑Not Observable
❑Not Applicable
C402.5 Building envelope contains a DComplies Requirement will be met.
[F155]1 continuous air barrier that has been ODoes Not
tested and deemed to limit air leakage Location on plans/spec:A-1
<= 0.40 cfm/ft2. ❑Not Applicable
C402.5.6 Weatherseals installed on all loading ❑Complies Exception: Requirement does not apply.
[FI37]1 dock cargo doors. ❑Does Not
❑Not Observable
❑Not Applicable
C403.2.2 HVAC systems and equipment DComplies Requirement will be met.
[F127]3 capacity does not exceed calculated ❑Does Not
loads. Location on plans/spec:A-1
❑Not Observable
❑Not Applicable
C403.2.4. Heating and cooling to each zone is DComplies Requirement will be met.
1 controlled by a thermostat control. ❑Does Not
[FI47]3 Minimum one humidity control device Location on plans/spec:A-1
per installed Not Observable
humidification/dehumidification ❑Not Applicable
system.
C403.2.4. Thermostatic controls have a 5 °F DComplies Requirement will be met.
1.2 deadband. EDoes Not
[FI38]3 Location on plans/spec:A-1
❑Not Observable
❑Not Applicable
C403.2.4. Temperature controls have setpoint ❑Complies Exception: Requirement does not apply.
1.3 overlap restrictions. Does Not
[FI20]3 ❑Not Observable
❑Not Applicable
C403.2.4. Each zone equipped with setback ❑Complies Exception: Requirement does not apply.
2 controls using automatic time clock or ❑Does Not
[FI39]3 programmable control system.
❑Not Observable
❑Not Applicable
C403.2.4. Automatic Controls: Setback to 55°F DComplies Exception: Requirement does not apply.
2.1, (heat)and 85°F(cool); 7-day clock,2- ❑Does Not
C403.2.4. hour occupant override, 10-hour
2.2 backup ❑Not Observable
[F140]3 ❑Not Applicable
C403.2.4. Systems include optimum start DComplies Exception: Requirement does not apply.
2.3 controls. ❑Does Not
[FI41]3 ❑Not Observable
❑Not Applicable
C405.4.1 Interior installed lamp and fixture DComplies See the Interior Lighting fixture schedule for values.
[F118]1 lighting power is consistent with what ❑Does Not
is shown on the approved lighting
plans, demonstrating proposed watts Not Observable
are less than or equal to allowed Observable,_,
Applicable
watts.
Ll High Impact(Tier 1) 1 2 LMedium Impact(Tier 2) 3 Low Impact(Tier 3) J
Project Title: New Restaurant Building Report date: 04/12/19
Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 16 of 18
Section
# Final Inspection Complies? Comments/Assumptions
& Req.ID
C405.5.1 Exterior lighting power is consistent ❑Complies See the Exterior Lighting fixture schedule for values.
[FI19]1 with what is shown on the approved ❑Does Not
lighting plans,demonstrating ['Not Observable
proposed watts are less than or equal ENot Applicable
erva
to allowed watts.
C408.2.1 Commissioning plan developed by ❑Complies Requirement will be met.
[F128]1 registered design professional or ❑Does Not
approved agency. Location on plans/spec:A-1
['Not Observable
ENot Applicable
C408.2.3. HVAC equipment has been tested to ❑Complies Requirement will be met.
1 ensure proper operation. ❑Does Not
[FI31]1 Location on plans/spec:A-1
❑Not Observable
❑Not Applicable
C408.2.3. HVAC control systems have been ❑Complies Requirement will be met.
2 tested to ensure proper operation, ❑Does Not
[FI10]1 calibration and adjustment of controls.! Location on plans/spec:A-1
❑Not Observable
❑Not Applicable
C408.2.4 Preliminary commissioning report ❑Complies Requirement will be met.
[FI29]1 completed and certified by registered ❑Does Not
design professional or approved ['Not Observable Location on plans/spec:A-1
agency. ❑Not Applicable
C408.2.5. Furnished HVAC as-built drawings ❑Complies ;Requirement will be met.
1 submitted within 90 days of system ❑Does Not
[FI7]3 acceptance.
❑Not Observable
❑Not Applicable
C408.2.5. Furnished as-built drawings for ❑Complies Requirement will be met.
1 electric power systems within 90 days !❑Does Not
[F116]3 of system acceptance.
:Not Observable'
❑Not Applicable
C408.2.5. An air and/or hydronic system I❑Complies Requirement will be met.
3 balancing report is provided for HVAC ❑Does Not
[F143]1 systems. Location on plans/spec:A-1
❑Not Observable
❑Not Applicable
C408.2.5. Final commissioning report due to ❑Complies Requirement will be met.
4 building owner within 90 days of ❑Does Not
[FI30]1 receipt of certificate of occupancy. ❑Not Observable Location on plans/spec:A-1
❑Not Applicable
C408.3 Lighting systems have been tested to ❑Complies Requirement will be met.
[FI33]1 ensure proper calibration, adjustment, !❑Does Not
programming,and operation. [Not Observable Location on plans/spec:A-1
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) t 2 iMedium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: New Restaurant Building Report date: 04/12/19
Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 17 of 18