Loading...
ComCheck REVIEWED FOR ENERGY CODE COMPLIANCE COMcheck Software Vert' Fi m 3 y * y CaA. co Ar ) Envelope Compliance Certificate o O � L 3CD = o Project Informationt.., [ 1 i -> a `D Energy Code: 2015 IECC APR 19 2019 v Q i ° 7J Project Title: New Restaurant Building - 0 Location: Glens Falls, New York TOWN OF OUEENSBURY Climate Zone: 6a 1BUILDING&CODES p n Project Type: New Construction a) n Vertical Glazing/Wall Area: 3% e N Co d Oiv CO No Construction Site: Owner/Agent: Designer/Contractor: -Pfl. C State Route 149 Dale Baldwin Ethan P. Hall u) —, S) Queensbury, NY 128041 Shake, Rattle&Roll Restaurant Rucinski Hall Architecture :, 7 ap State Route 149 134 Dix Ave "'' Queensbury, NY 12804 Glens Falls, NY 12801 518-741-0268 - Additional Efficiency Package(s) ephall@nycap.rr.com Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations. Building Area Floor Area FILE COPY 1-Dining: Family: Nonresidential 2665 Envelope Assemblies Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factor)a) Perimeter Roof 1:Attic Roof with Wood Joists,[Bldg.Use 1 -Dining:Family] 2665 38.0 0.0 0.027 0.021 NORTH Exterior Wall 1:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Dining:Family] 1315 21.0 3.6 0.049 0.051 Door 1:Insulated Metal,Swinging,[Bldg.Use 1 -Dining:Family] 21 --- 0.300 0.370 Door 2: Insulated Metal,Swinging,[Bldg.Use 1 -Dining:Family] 21 --- --- 0.300 0.370 Door 3: Insulated Metal,Swinging,[Bldg.Use 1 -Dining:Family] 21 --- --- 0.300 0.370 Basement Wall 1:Solid Concrete:8"Thickness,Normal Density, 516 --- 10.0 0.088 0.108 Furring:None,Wall Ht 8.9,Depth B.G.8.0,[Bldg.Use 1 -Dining: Family] Basement Wall 5:Solid Concrete:8"Thickness,Normal Density, 243 --- 10.0 0.088 0.108 Furring:None,Wall Ht 4.9,Depth B.G.4.0,[Bldg.Use 1 -Dining: Family] EAST Exterior Wall 2:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Dining:Family] 789 21.0 3.6 0.049 0.051 Window 1:Metal Frame with Thermal Break:Fixed,Perf.Specs.: 40 --- --- 0.290 0.360 Product ID product label,SHGC 0.33,[Bldg.Use 1 -Dining:Family](b) Basement Wall 2:Solid Concrete:8"Thickness,Normal Density, 250 --- 10.0 0.088 0.108 Furring:None,Wall Ht 8.9,Depth B.G.8.0,[Bldg.Use 1 -Dining: Family] Basement Wall 6:Solid Concrete:8"Thickness,Normal Density, 180 --- 10.0 0.088 0.108 Furring:None,Wall Ht 4.9,Depth B.G.4.0,[Bldg.Use 1 -Dining: Family] Project Title: New Restaurant Building Report date: 04/12/19 Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 1 of 18 Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factor(,) Perimeter SOUTH Exterior Wall 3:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Dining:Family] 1315 21.0 3.6 0.049 0.051 Window 2:Metal Frame with Thermal Break:Fixed,Perf.Specs.: 90 --- --- 0.290 0.360 Product ID product label,SHGC 0.33,[Bldg.Use 1 -Dining:Family](b) Door 4: Insulated Metal,Swinging,[Bldg.Use 1 -Dining:Family] 21 --- --- 0.300 0.370 Door 5:Insulated Metal,Swinging,[Bldg.Use 1 -Dining:Family] 21 --- --- 0.300 0.370 Door 6:Insulated Metal,Non-Swinging,[Bldg.Use 1 -Dining:Family] 32 --- --- 0.300 0.179 Door 7:Insulated Metal,Non-Swinging,[Bldg.Use 1 -Dining:Family] 32 --- --- 0.300 0.179 Basement Wall 3:Solid Concrete:8"Thickness,Normal Density, 516 --- 10.0 0.088 0.108 Furring:None,Wall Ht 8.9,Depth B.G.8.0,[Bldg.Use 1 -Dining: Family] Basement Wall 7:Solid Concrete:8"Thickness,Normal Density, 147 --- 10.0 0.088 0.108 Furring:None,Wall Ht 4.9,Depth B.G.4.0,[Bldg.Use 1 -Dining: Family] WEST Exterior Wall 4:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Dining:Family] 789 21.0 3.6 0.049 0.051 Window 3:Metal Frame with Thermal Break:Fixed,Perf.Specs.: 18 --- --- 0.290 0.360 Product ID product label,SHGC 0.33,[Bldg.Use 1 -Dining:Family](b) Door 8:Insulated Metal,Swinging,[Bldg.Use 1 -Dining:Family] 21 --- --- 0.300 0.370 Basement Wall 4:Solid Concrete:8"Thickness,Normal Density, 250 --- 10.0 0.088 0.108 Furring:None,Wall Ht 8.9,Depth B.G.8.0,[Bldg.Use 1 -Dining: Family] Basement Wall 8:Solid Concrete:8"Thickness,Normal Density, 59 --- 10.0 0.088 0.108 Furring:None,Wall Ht 4.9,Depth B.G.4.0,[Bldg.Use 1 -Dining: Family] (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. (b)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. Envelope PASSES: Design 8% better than code Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed envelope systems have been designed to meet the 2015 IECC requirements in COMcheck Ver ion 4.1.1. and to mpl with any applicable mandatory requirements listed in the Inspection Checklist. Ethan P. Hall-Architect l2,4,020/1 Name-Title Sig re Date Project Title: New Restaurant Building Report date: 04/12/19 Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 2 of 18 A( COMcheck Software Version 4.1.1.0 1 Interior Lighting Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: New Restaurant Building Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: State Route 149 Dale Baldwin Ethan P. Hall Queensbury, NY 128041 Shake, Rattle&Roll Restaurant Rucinski Hall Architecture State Route 149 134 Dix Ave Queensbury, NY 12804 Glens Falls, NY 12801 518-741-0268 Additional Efficiency Package(s) ephall@nycap.rr.com Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations. Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Common Space Types:Dining Area-Family Restaurant 2100 0.80 1680 2-Common Space Types:Food Preparation 565 1.09 616 Total Allowed Watts= 2296 Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. 1-Common Space Types:Dining Area-Family Restaurant LED 1:LED Linear 17W: 1 34 32 1088 2-Common Space Types:Food Preparation LED 2:LED PAR 15W: 1 25 32 800 Total Proposed Watts= 1888 Interior Lighting PASSES: Design 18% better than code Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Ver ion 4.1.1. nd t mpl with any applicable mandatory requirements listed in the Inspection Checklist. Ethan P. Hall-Architect 401.�oe9 Name-Title Sig re Date Project Title: New Restaurant Building Report date: 04/12/19 Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 3 of 18 \fiCOMcheck Software Version 4.1.1.0 l Exterior Lighting Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: New Restaurant Building Project Type: New Construction Exterior Lighting Zone 2(Neighborhood business district) Construction Site: Owner/Agent: Designer/Contractor: State Route 149 Dale Baldwin Ethan P. Hall Queensbury, NY 128041 Shake, Rattle&Roll Restaurant Rucinski Hall Architecture State Route 149 134 Dix Ave Queensbury, NY 12804 Glens Falls, NY 12801 518-741-0268 ephall@nycap.rr.com Allowed Exterior Lighting Power A B C D E Area/Surface Category Quantity Allowed Tradable Allowed Watts Watts/Unit Wattage (B X C) Parking area 6 ft2 0.06 Yes 0 Entry canopy 5 ft2 0.25 Yes 1 Total Tradable Watts(a)= 2 Total Allowed Watts= 2 Total Allowed Supplemental Watts(b)= 600 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Parking area (6 ft2):Tradable Wattage LED 3:LED Roadway-Parking Unit 54W: 2 6 64 384 Entry canopy(5 ft2):Tradable Wattage LED 4:LED PAR 17W: 1 5 32 160 Total Tradable Proposed Watts= 544 Exterior Lighting PASSES: Design 10% better than code Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed exterior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1. 0 and com with any applicable mandatory requirements listed in the Inspection Checklist. //��,,//�� /J Ethan P. Hall-Architect • /2 AI2 Zay Name-Title S ature Date Project Title: New Restaurant Building Report date: 04/12/19 Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 4 of 18 NfiCOMcheck Software Version 4.1.1.0 l Mechanical Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: New Restaurant Building Location: Glens Falls, New York Climate Zone: 6a Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: State Route 149 Dale Baldwin Ethan P. Hall Queensbury, NY 128041 Shake, Rattle&Roll Restaurant Rucinski Hall Architecture State Route 149 134 Dix Ave Queensbury, NY 12804 Glens Falls, NY 12801 518-741-0268 Additional Efficiency Package(s) ephall@nycap.rr.com Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations. Mechanical Systems List Quantity System Type&Description 1 HVAC System 1 (Single Zone): Heating: 1 each-Central Furnace,Gas,Capacity=65 kBtu/h Proposed Efficiency=93.00%Et,Required Efficiency: 80.00%Et or 78%AFUE Cooling: 1 each-Field-Assembled DX System,Capacity=45 kBtu/h,Air-Cooled Condenser,Air Economizer No minimum efficiency requirement applies Fan System: FAN SYSTEM 1 --Compliance(Motor nameplate HP method):Passes Fans: FAN 1 Supply,Single-Zone VAV, 1400 CFM,0.5 motor nameplate hp,0.0 fan efficiency grade Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2015 IECC requirements in COMcheck V- '+ 4.1.1.0 d to co ly wi any applicable mandatory requirements listed in the Inspection Checklist. - / ,/ Ethan P. Hall-Architect '� 441 2e/s7 Name-Title Sign- ure Date Project Title: New Restaurant Building Report date: 04/12/19 Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 5 of 18 COMcheck Software Version 4.1.1.0 Inspection Checklist Energy Code: 2015 IECC Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans and/or specifications provide all ❑Complies Requirement will be met. [PR1]1 information with which compliance ❑Does Not can be determined for the building ❑Not Observable Location on plans/spec:A-1 envelope and document where exceptions to the standard are ;❑Not Applicable claimed. C103.2 Plans,specifications,and/or ❑Complies Requirement will be met. [PR2]i calculations provide all information ;❑Does Not with which compliance can be ❑Not Observable Location on plans/spec:A-1 determined for the mechanical systems and equipment and DNot Applicable document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. C103.2 Plans,specifications,and/or ❑Complies Requirement will be met. [PR4]i calculations provide all information ❑Does Not with which compliance can be ['Not Observable Location on plans/spec:A-1 determined for the interior lighting and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations,wattage of: bulbs and ballasts,transformers and control devices. C103.2 Plans,specifications,and/or ❑Complies Requirement will be met. [PR8]1 calculations provide all information ❑Does Not with which compliance can be [Not Observable Location on plans/spec:A-1 determined for the exterior lighting and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations,wattage of bulbs and ballasts,transformers and control devices. C402.4.1 The vertical fenestration area <= 30 ❑Complies :Requirement will be met. [PR10]i percent of the gross above-grade wall ❑Does Not area. Location on plans/spec:A-1 ❑Not Observable ❑Not Applicable C402.4.1 The skylight area <= 3 percent of the ❑Complies Requirement will be met. [PR11]i gross roof area. ❑Does Not ❑Not Observable Location on plans/spec:A-1 ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New Restaurant Building Report date: 04/12/19 Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 6 of 18 Section Plan Review Complies? Comments/Assumptions &Req.ID C406 Plans, specifications,and/or ❑Complies Requirement will be met. [PR9]1 calculations provide all information ❑Does Not with which compliance can be ['Not Observable Location on plans/spec:A-1 determined for the additional energy . efficiency package options. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) I, 3 iLow Impact(Tier 3) Project Title: New Restaurant Building Report date: 04/12/19 Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 7 of 18 Section Footing/Foundation Inspection Complies? Comments/Assumptions & Req.ID C303.2 Below-grade wall insulation installed ❑Complies Requirement will be met. [FO2]2 per manufacturer's instructions. ❑Does Not "Not Observable,Location on plans/spec:A-1 ONot Applicable C303.2.1 Exterior insulation protected against DComplies Requirement will be met. [FO6]1 damage,sunlight, moisture,wind, ❑Does Not landscaping and equipment maintenance activities. Not Observable ❑Not Applicable C402.1.4 Below-grade wall insulation R-value. ❑Complies See the Envelope Assemblies table for values. [FO1]2 ❑Does Not ['Not Observable ❑Not Applicable C403.2.4. Snow/ice melting system sensors for ❑Complies Exception: Requirement does not apply. 5, future connection to controls.Freeze Does Not C403.2.4. protection systems have automatic 6 controls installed. ❑Not Observable [FO9]3 ❑Not Applicable Additional Comments/Assumptions: LlJHigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 [Low Impact(Tier 3) Project Title: New Restaurant Building Report date: 04/12/19 Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 8 of 18 Section # Framing/Rough-In Inspection Complies? Comments/Assumptions & Req.ID C303.1.3 Fenestration products rated in ❑Complies Requirement will be met. [FR12]2 accordance with NFRC. ❑Does Not ❑Not Observable Location on plans/spec:A-1 ❑Not Applicable C303.1.3 Fenestration products are certified as ❑Complies Requirement will be met. [FRi3]1 to performance labels or certificates ❑Does Not provided. Location on plans/spec:A-i ['Not Observable ❑Not Applicable C402.4.3 Vertical fenestration SHGC value. ❑Complies See the Envelope Assemblies table for values. [FR10]1 ❑Does Not ❑Not Observable ❑Not Applicable C402.4.3, Vertical fenestration U-Factor. ❑Complies See the Envelope Assemblies table for values. C402.4.3. ElDoes Not 4 [FR8]1 ❑Not Observable ❑Not Applicable C402.4.4 U-factor of opaque doors associated '❑Complies See the Envelope Assemblies table for values. [FR14]2 with the building thermal envelope ❑Does Not meets requirements. ❑Not Observable ❑Not Applicable C402.5.7 Vestibules are installed on all building ❑Complies Requirement will be met. [FR17]3 entrances. Doors have self-closing ❑Does Not devices. Location on plans/spec:A-1 ❑Not Observable' ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New Restaurant Building Report date: 04/12/19 Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 9 of 18 Section # Plumbing Rough-In Inspection Complies? Comments/Assumptions & Req.ID C404.5, Heated water supply piping conforms ❑Complies Exception: Requirement does not apply. C404.5.1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details.[PL6]3 ❑Not Observable ❑Not Applicable C404.6.3 Pumps that circulate water between a ❑Complies Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to <= 5 minutes after end of heating ❑Not Observable cycle. ❑Not Applicable C404.7 Water distribution system that pumps ❑Complies Exception: Requirement does not apply. [PL8]3 water from a heated-water supply ❑Does Not pipe back to the heated-water source through a cold-water supply pipe is a ❑Not Observable demand recirculation water system. ❑Not Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. Additional Comments/Assumptions: 1 High Impact(Tier 1) 12 {Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New Restaurant Building Report date: 04/12/19 Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle& Roll.cck Page 10 of 18 Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C402.2.6 Thermally ineffective panel surfaces of❑Complies Exception: Requirement does not apply. [ME41]3 sensible heating panels have ❑Does Not insulation >= R-3.5. [Not Observable ❑Not Applicable C402.5.5, Stair and elevator shaft vents have ❑Complies Exception: Requirement does not apply. C403.2.4. motorized dampers that automatically ❑Does Not 3[MEWclose. ['Not Observable ❑Not Applicable C402.5.5, Outdoor air and exhaust systems have!❑Complies Requirement will be met. C403.2.4. motorized dampers that automatically ❑Does Not 3 shut when not in use and meet Location on plans/spec:A-1 [ME58]3 maximum leakage rates.Check ENot Observable gravity dampers where allowed. ❑Not Applicable C403.2.13 Unenclosed spaces that are heated ❑Complies Exception: Requirement does not apply. [ME71]2 use only radiant heat. ElDoes Not ❑Not Observable ❑Not Applicable C403.2.3 HVAC equipment efficiency verified. ❑Complies See the Mechanical Systems list for values. [ME55]2 ❑Does Not ❑Not Observable ❑Not Applicable C403.2.6. 'Demand control ventilation provided ❑Complies Exception: Requirement does not apply. 1 for spaces>500 ft2 and >25 ❑Does Not [ME59]1 people/1000 ft2 occupant density and served by systems with air side ['Not Observable economizer,auto modulating outside ❑Not Applicable air damper control, or design airflow >3,000 cfm. C403.2.6. Enclosed parking garage ventilation '❑Complies Exception: Requirement does not apply. 2 has automatic contaminant detection ❑Does Not [ME115]3 and capacity to stage or modulate fans to 50%or less of design capacity. ['Not Observable' ❑Not Applicable C403.2.7 Exhaust air energy recovery on ❑Complies Exception: Requirement does not apply. [ME57]1 systems meeting Table C403.2.7(1) ❑Does Not and C403.2.7(2). ❑Not Observable ❑Not Applicable C403.2.8 Kitchen exhaust systems comply with ❑Complies Requirement will be met. [ME116]3 °replacement air and conditioned ODoes Not supply air limitations, and satisfy hood Location on plans/spec:A-1 rating requirements and maximum ❑Not Observable exhaust rate criteria. Observable,__, Applicable C403.2.9 HVAC ducts and plenums insulated. ❑Complies Requirement will be met. [ME60]2 Where ducts or plenums are installed !❑Does Not in or under a slab,verification may Location on plans/spec:A-1 need to occur during Foundation Not Observable Inspection. ❑Not Applicable C403.2.9 Ducts and plenums sealed based on ❑Complies Requirement will be met. [ME10]2 static pressure and location. ❑Does Not ❑Not Observable Location on plans/spec:A-1 ❑Not Applicable C403.2.9. Ductwork operating >3 in.water ❑Complies Exception: Requirement does not apply. 1.3 column requires air leakage testing. ❑Does Not [ME11]3 ❑Not Observable ❑Not Applicable 1 IHigh Impact(Tier 1) I 2 j Medium Impact(Tier 2) 3 I Low Impact(Tier 3) Project Title: New Restaurant Building Report date: 04/12/19 Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 11 of 18 Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C403.4.4. Multiple zone VAV systems with DDC ❑Complies Exception: Requirement does not apply. 6 of individual zone boxes have static ❑Does Not [ME110]3 pressure setpoint reset controls. See the Mechanical Systems list for values. ❑Not Observable ❑Not Applicable C408.2.2. Air outlets and zone terminal devices ;❑Complies Exception: Requirement does not apply. 1 have means for air balancing. ❑Does Not [ME53]3 ❑Not Observable ❑Not Applicable C403.5, Refrigerated display cases, walk-in ❑Complies Exception: Requirement does not apply. C403.5.1, coolers or walk-in freezers served by ODoes Not C403.5.2 remote compressors and remote [ME123]3 condensers not located in a ❑Not Observable condensing unit, have fan-powered ❑Not Applicable condensers that comply with Sections C403.5.1 and refrigeration compressor systems that comply with C403.5.2.. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 I Low Impact(Tier 3) I Project Title: New Restaurant Building Report date: 04/12/19 Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 12 of 18 Section # Rough-In Electrical Inspection Complies? Comments/Assumptions &Req.ID C405.2.1 Lighting controls installed to uniformly ❑Complies Requirement will be met. [ELi5]1 reduce the lighting load by at least ❑Does Not 50%. Location on plans/spec:A-1 ❑Not Observable ❑Not Applicable C405.2.1 Occupancy sensors installed in ❑Complies Requirement will be met. [ELi8]1 required spaces. ❑Does Not ❑Not Observable Location on plans/spec:A-1 ❑Not Applicable C405.2.1, Independent lighting controls installed ❑Complies Requirement will be met. C405.2.2. per approved lighting plans and all ❑Does Not 3 manual controls readily accessible and Location on plans/spec:A-1 [EL23]2 visible to occupants. ❑Not Observable ❑Not Applicable C405.2.2. Automatic controls to shut off all ❑Complies Requirement will be met. 1 building lighting installed in all Does Not [EL2212 buildings. Location on plans/spec:A-1 ['Not Observable ❑Not Applicable C405.2.3 Daylight zones provided with ❑Complies Exception: Requirement does not apply. [ELi6]2 individual controls that control the ❑Does Not lights independent of general area lighting. ❑Not Observable !❑Not Applicable C405.2.3, Primary sidelighted areas are ;❑Complies Exception: Requirement does not apply. C405.2.3. equipped with required lighting '❑Does Not 1, controls. C405.2.3. ❑Not Observable 2 ❑Not Applicable [EL20]1 C405.2.3, Enclosed spaces with daylight area ElComplies Exception: Requirement does not apply. C405.2.3. under skylights and rooftop monitors ❑Does Not 1, are equipped with required lighting C405.2.3. controls. ❑Not Observable 3 ❑Not Applicable [EL21]1 C405.2.4 Separate lighting control devices for ❑Complies Requirement will be met. [EL4]1 specific uses installed per approved ❑Does Not lighting plans. Location on plans/spec:A-1 ['Not Observable ❑Not Applicable C405.2.4 Additional interior lighting power ❑Complies Requirement will be met. [EL8]1 allowed for special functions per the ❑Does Not approved lighting plans and is ❑Not Observable Location on plans/spec:A-1 automatically controlled and separated from general lighting. ❑Not Applicable C405.2.5 Automatic lighting controls for exterior'❑Complies Requirement will be met. [EL25pull lighting installed.Controls will be ❑Does Not daylight controlled,set based on Location on plans/spec:A-1 business operation time-of-day,or ❑Not Observable reduce connected lighting > 30%. ❑Not Applicable C405.3 Exit signs do not exceed 5 watts per ❑Complies Requirement will be met. [EL6]1 face. ❑Does Not ❑Not Observable Location on plans/spec:A-1 ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) I 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New Restaurant Building Report date: 04/12/19 Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 13 of 18 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New Restaurant Building Report date: 04/12/19 Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 14 of 18 Section # Insulation Inspection Complies? Comments/Assumptions & Req.ID C303.1 Roof insulation installed per ❑Complies Requirement will be met. [IN3]1 manufacturer's instructions. Blown or ❑Does Not poured loose-fill insulation is installed ['Not Observable Location on plans/spec:A-1 only where the roof slope is<=3 in 12. ONot Applicable C303.1 Building envelope insulation is labeled ❑Complies Requirement will be met. [IN10]2 with R-value or insulation certificate ❑Does Not providing R-value and other relevant data. ONot Observable ONot Applicable C303.2 Above-grade wall insulation installed ❑Complies Requirement will be met. [IN7]1 per manufacturer's instructions. ❑Does Not DNot Observable!Location on plans/spec:A-i ONot Applicable C303.2.1 Exterior insulation is protected from ❑Complies Exception: Requirement does not apply. [IN14]2 damage with a protective material. ❑Does Not Verification for exposed foundation insulation may need to occur during ONot Observable Foundation Inspection. ONot Applicable C402.1.3 Non-swinging opaque doors have R- ❑Complies Requirement will be met. [IN19]3 4.75 insulation. Does Not ['Not Observable Location on plans/spec:A-i ONot Applicable C402.2.1 'Insulation intended to meet the roof ❑Complies Requirement will be met. [IN17]3 insulation requirements cannot be ❑Does Not installed on top of a suspended Location on plans/spec:A-1 ceiling. Mark this requirement ONot Observable compliant if insulation is installed ONot Applicable accordingly. C402.2.3 Above-grade wall insulation R-value. ❑Complies See the Envelope Assemblies table for values. [IN6]1 ❑Does Not ['Not Observable'. ONot Applicable C402.2.6 Radiant panels and associated DComplies Exception: Requirement does not apply. [IN18]3 components, designed for heat ❑Does Not transfer from the panel surfaces to the occupants or indoor space are ONot Observable insulated with a minimum of R-3.5. ONot Applicable C402.2.2 Roof R-value. For some ceiling ❑Complies See the Envelope Assemblies table for values. [IN2]1 systems,verification may need to ❑Does Not occur during Framing Inspection. ['Not Observable ONot Applicable C402.5.1. All sources of air leakage in the ❑Complies Requirement will be met. 1 building thermal envelope are sealed, ODoes Not [INi]1 caulked, gasketed,weather stripped ONot Observable Location on plans/spec:A-1 or wrapped with moisture vapor- permeable wrapping material to ONot Applicable minimize air leakage. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 tMedium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New Restaurant Building Report date: 04/12/19 Data filename: Y:\Baldwin, Dale\Shake Rattle and RoII\Shake-Rattle&Roll.cck Page 15 of 18 Section # Final Inspection Complies? Comments/Assumptions & Req.ID C303.3, Furnished O&M instructions for DComplies Requirement will be met. C408.2.5. systems and equipment to the ❑Does Not 2 3 building owner or designated ❑Not Observable [FI17] representative. ❑Not Applicable C303.3, Furnished O&M manuals for HVAC DComplies Requirement will be met. C408.2.5. systems within 90 days of system ❑Does Not 3 acceptance. [FI8]3 ❑Not Observable ❑Not Applicable C402.5 Building envelope contains a DComplies Requirement will be met. [F155]1 continuous air barrier that has been ODoes Not tested and deemed to limit air leakage Location on plans/spec:A-1 <= 0.40 cfm/ft2. ❑Not Applicable C402.5.6 Weatherseals installed on all loading ❑Complies Exception: Requirement does not apply. [FI37]1 dock cargo doors. ❑Does Not ❑Not Observable ❑Not Applicable C403.2.2 HVAC systems and equipment DComplies Requirement will be met. [F127]3 capacity does not exceed calculated ❑Does Not loads. Location on plans/spec:A-1 ❑Not Observable ❑Not Applicable C403.2.4. Heating and cooling to each zone is DComplies Requirement will be met. 1 controlled by a thermostat control. ❑Does Not [FI47]3 Minimum one humidity control device Location on plans/spec:A-1 per installed Not Observable humidification/dehumidification ❑Not Applicable system. C403.2.4. Thermostatic controls have a 5 °F DComplies Requirement will be met. 1.2 deadband. EDoes Not [FI38]3 Location on plans/spec:A-1 ❑Not Observable ❑Not Applicable C403.2.4. Temperature controls have setpoint ❑Complies Exception: Requirement does not apply. 1.3 overlap restrictions. Does Not [FI20]3 ❑Not Observable ❑Not Applicable C403.2.4. Each zone equipped with setback ❑Complies Exception: Requirement does not apply. 2 controls using automatic time clock or ❑Does Not [FI39]3 programmable control system. ❑Not Observable ❑Not Applicable C403.2.4. Automatic Controls: Setback to 55°F DComplies Exception: Requirement does not apply. 2.1, (heat)and 85°F(cool); 7-day clock,2- ❑Does Not C403.2.4. hour occupant override, 10-hour 2.2 backup ❑Not Observable [F140]3 ❑Not Applicable C403.2.4. Systems include optimum start DComplies Exception: Requirement does not apply. 2.3 controls. ❑Does Not [FI41]3 ❑Not Observable ❑Not Applicable C405.4.1 Interior installed lamp and fixture DComplies See the Interior Lighting fixture schedule for values. [F118]1 lighting power is consistent with what ❑Does Not is shown on the approved lighting plans, demonstrating proposed watts Not Observable are less than or equal to allowed Observable,_, Applicable watts. Ll High Impact(Tier 1) 1 2 LMedium Impact(Tier 2) 3 Low Impact(Tier 3) J Project Title: New Restaurant Building Report date: 04/12/19 Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 16 of 18 Section # Final Inspection Complies? Comments/Assumptions & Req.ID C405.5.1 Exterior lighting power is consistent ❑Complies See the Exterior Lighting fixture schedule for values. [FI19]1 with what is shown on the approved ❑Does Not lighting plans,demonstrating ['Not Observable proposed watts are less than or equal ENot Applicable erva to allowed watts. C408.2.1 Commissioning plan developed by ❑Complies Requirement will be met. [F128]1 registered design professional or ❑Does Not approved agency. Location on plans/spec:A-1 ['Not Observable ENot Applicable C408.2.3. HVAC equipment has been tested to ❑Complies Requirement will be met. 1 ensure proper operation. ❑Does Not [FI31]1 Location on plans/spec:A-1 ❑Not Observable ❑Not Applicable C408.2.3. HVAC control systems have been ❑Complies Requirement will be met. 2 tested to ensure proper operation, ❑Does Not [FI10]1 calibration and adjustment of controls.! Location on plans/spec:A-1 ❑Not Observable ❑Not Applicable C408.2.4 Preliminary commissioning report ❑Complies Requirement will be met. [FI29]1 completed and certified by registered ❑Does Not design professional or approved ['Not Observable Location on plans/spec:A-1 agency. ❑Not Applicable C408.2.5. Furnished HVAC as-built drawings ❑Complies ;Requirement will be met. 1 submitted within 90 days of system ❑Does Not [FI7]3 acceptance. ❑Not Observable ❑Not Applicable C408.2.5. Furnished as-built drawings for ❑Complies Requirement will be met. 1 electric power systems within 90 days !❑Does Not [F116]3 of system acceptance. :Not Observable' ❑Not Applicable C408.2.5. An air and/or hydronic system I❑Complies Requirement will be met. 3 balancing report is provided for HVAC ❑Does Not [F143]1 systems. Location on plans/spec:A-1 ❑Not Observable ❑Not Applicable C408.2.5. Final commissioning report due to ❑Complies Requirement will be met. 4 building owner within 90 days of ❑Does Not [FI30]1 receipt of certificate of occupancy. ❑Not Observable Location on plans/spec:A-1 ❑Not Applicable C408.3 Lighting systems have been tested to ❑Complies Requirement will be met. [FI33]1 ensure proper calibration, adjustment, !❑Does Not programming,and operation. [Not Observable Location on plans/spec:A-1 ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) t 2 iMedium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New Restaurant Building Report date: 04/12/19 Data filename: Y:\Baldwin, Dale\Shake Rattle and Roll\Shake-Rattle&Roll.cck Page 17 of 18