ResCheck V �' E �dJ c r �l r i:/n . `6.5 a) Lo ui f ii.7 Compliance Ce if c e M M illyEciEuvE- N co Project Taftl�� oI72j � J6 Energy Code: 2015 IECC HTOWNAOPFR I________ ...i E a) Location: Glens Falls, New York BUILDING �� 0 = N Construction Type: Single-family �.a CODES 12 a Project Type: New Construction -0 LL Y 0 Conditioned Floor Area: 2,910 ft2 r 3 0 cn c Glazing Area 11% FILE COPY p Climate Zone: 6 (7635 HDD) I 1.- _U Permit Date: [Y 0 00 Permit Number: O G O V- M21` (n Construction Site: Owner/Agent: Designer/Contractor: ,_ _ 70 Richmond Hill Drive Hodorowski Homes Northstar Home Design, LLC Queensbury, NY Compliance Passes using UA trade-off Compliance: 1.9%Better Than Code Maximum UA: 416 Your UA: 408 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. FOR It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. REVIEWED Erlvel, p Assemblies ENERGY CODE COMPLJANC7' Gross Area Cavity Cont. Assembly or U-Factor UA Perimeter R-Value R-Value Ceiling 1:Raised or Energy Truss 1,804. 49.0. 0.0 _0.020 36. Wall 1:Wood Frame, 16"o.c. 3,614 21.0 0.0 0.057 181 Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 368 0.300 110 Door 1:Solid 51. 0.190 10 Door 2:Glass 20 0.300 6 Basement Wall 1: Solid Concrete or Masonry 1,552 19.0 5.0 0.037 57 Wall height:8.0' Depth below grade:7.0' Insulation depth: 8.0' Floor 1:All-Wood joist/Truss:Over Unconditioned Space 252 30.0 0.0 0.033 8 Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.5.and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. li AR Name-Title SignatureFoas Date �.,of .0 ' d Project Title:Taft Report date: 04/03/19 Data filename: C:\Userstjkazl\OneDrive\Documents\REScheck\70 Richmond•. �.'vexck Page 1 of 9 RESeheck o are Versio -.6.5 4 ; Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions"column is provided by the user in the-REScheck Requirements screen.For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section P6 f®Ig�s �'� i®n/�1a�9 Review Pans Verified Held Verified p Value Value Complies? Comments/Assumptions &Req.iD 103.1, 'Construction drawings and OComplies '103.2 documentation demonstrate Oboes Not [PRIV- energy code compliance for the ;ONof Observable building envelope.Thermal envelope represented on ONot Applicable construction documents. 103.1, ;Construction drawings and OComplies 103.2, documentation demonstrate ODoes Not 403.7 energy code compliance for QNot Observable [PR31' :lighting and mechanical systems. Systems serving multiple '.ONot Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is- Heating: ; Heating: OComplies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR212 on loads calculated per ACCA Cooling: 'Manual)or other methods Cooling: ;QNot Observable Btu/hr Btu/hr ONot approved by the code official. Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project-Title:Taff Report-date: 04/03/19 Data filename:C:\Users\jkazl\OneDrivetDocuments\REScheck\70 Richmond Hill Drive.rck Page 2 of 9 Section 1 i Plans Verified Field Verified - # Foundation Inspection Plans Value Complies? Comments/Assumptions & Regal, 402.1.1 Conditioned basement wall R R- ;❑Complies See the Envelope Assemblies [F04]1 insulation R-value.Where interior: R_ R_ ❑Does Not table for values. insulation is used,verification may need to occur during ❑Not Observable Insulation Inspection.Not ❑Nat Applicable • required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [F05]1 ;insulation installed per .❑Does Not manufacturer's instructions. :❑Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft ;❑Complies :See the Envelope Assemblies [F06]1 insulation depth of burial or ❑Does Not 'table for values. distance from top of wall. .� ;❑Not Observable ❑Not Applicable 343.2.1 A protective covering is installed .DComplies [F011.]2; to protect exposed exterior ❑Does Not insulation and extends a • minimum of 6 in.below grade. ❑Not Observable ❑Not Applicable 403.9 Snow-and system ;❑Complies. [F012}2 controls installed. ❑Does Not ❑Not-Observable ❑Not Applicable , Additional Comments/Assumptions: 1 High Impart(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) ProjectTitie:Taft Report date: 04/03/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\70 Richmond Hill Drive.rck Page 3 of 9 :: : rsV Ps eried Field)VerilciedFram inug/Roughln Inspection erCplies? Comments/Asumptions Vague® 402.1.1, 'Door U-factor. U- U- ;QComplies See the Envelope Assemblies 402.3.4 QDaes Not 'table for values. [FR1]1 fi ❑Not Observable ;QNot Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ;❑Complies ;See the Envelope Assemblies 402.3.1, average). QDoes Not table for values. 402.3.3, 402.5 i❑Not Observable [FR211 QNot Applicable 303.1.3 U-factors of fenestration products' QCamplies [FR411 are determined in accordance ❑Does Not _ with the NFRC test procedure or taken from the default table. ❑Not Observable QNot Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed permanufacturer's ❑Does Not ._r., instructions. - _ ;QNot Observable QNot Applicable 402.4.3 ;Fenestration that is not site built ❑Complies [FR20]1 `is listed and labeled as meeting - - QDoes Not AAMA-/WDMA/CSA 101/1.5.2/A440- or has infiltration rates per NFRC : ❑IVot Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures 'QComplies [FR1612 sealed at housing/interior finish QDoes Not and labeled to indicate-<_2.0 cirri - leakage at 75 Pa. QNot Observable ![Not Applicable 403.3.1 ;Supply and return ducts in attics ;❑Complies [FR1211 insulated>=R-8 where duct is ❑Does Not >=-3 inches in diameter and>= - R-6 where<3 inches.Supply and [(Not Observable return ducts in other portions of ❑Not Applicable ;the building insulated>=R-6 for - diameter>=3 inches and R-4.2 - - for<3 inches in-diameter. 1403.3.5 Building cavities are not used as ;❑Complies [FRi5]3 ducts or plenums-. ❑Does Not L,A QNot Observable ❑Not Applicable 403.4 :HVAC piping conveying fluids ; R- ' R- '❑Complies [FR17]2 above 105°F-or chilled fluids QDoes Not below 55 OF are insulated.to_>R ,- 3 ❑Not Observable QNot Applicable 403.4.1 ;Protection of insulation on HVAC QComplies [FR24]1 piping. QDoes Not , - - ,❑Not Observable ❑Not Applicable 403.5.3 :Hot water pipes are insulated to R-- R- ❑Complies [FR1812 >_R-3: UDoes Not '0Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are: QComplies [FR1912 installed on all outdoor air ❑Does Not intakes and exhausts. [Not Observable ❑Not Applicable I 1 High Impact'(Tier 1) 2- Medium-Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Taft Report date: 04/03/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\70 Richmond Hill Drive.rck Page 4 of 9 Additional Comments/Assumptions: 1 High impact(Tier 1) 2 Medium impact(Tier 2) 3 Low impact(Tier 3) ProjectTitie:Taft Report-date:- 04103/19 Data filename: C:\UsersVkaz1\OneDrive\Documents\REScheck\70 Richmond Hill Drive.rck Page 5 of 9 - 1 Section P r Plans Verified Field�eriffied !insulation inspection Complies? Co mments/Assumptions t1t Recgolr,I I Value Value €303.1 All installed insulation is labeled []Complies [IN13J2 or the installed R-values []Does Not . provided. []Not Observable []Not Applicable 402.1.1, ;Floor insulation R-value. R- ; R- ,[]Complies ;See the Envelope Assemblies 402.2.6 ;❑.Wood Wood :[]Does Not ,table for values. Steel ❑ Steel :DNot Observable []Not Applicable 303.2, Floor insulation installed per []Complies 402.2.7 manufacturer's instructions and i ©Does Not [IN211 'in substantial contact with the []Not Observable _, ,underside of the subftoor,or floor []Not I framing cavity insulation is in Applicable contact with the top side of sheathing,or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, :Wall insulation R-value.If this is a; R- R- ;[]Complies 'See the Envelope Assemblies 402.2.5, ,mass wall with at least 1/2 of the U Wood ❑ Wood ;[]Does Not table for values. 402.2.E ;welt insulation on the wall Mass ;0 Mass ;[]Not Observable [IN313 'exterior,the exterior insulation ;; requirement applies(FRIO). ❑ steel Steel i[]Not Applicable j 303.2 Wall insulation is installed per []Complies [IN41'- 'manufacturer's instructions. []Does Not [Not Observable []Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) ProjectTitle:Taft- Report-date: 04/03/19 Data filename:C:\Users\jkaz1\OneDrive\Documents\REScheck\70 Richmond Hill Drive.rck Page 6 of 9 Section Plans Verified Fiie0 ,Verified Fiiaail;is�spe�tio� �roe�isioo�� Value Value Complies Corarrie ts/Assilo -.t ° i& Req.l 402.1.1, ,Ceiling insulation R-value. : R- R- ❑Complies ;See the Envelope Assemblies 402.2.1, ,❑ Wood ;❑ Wood DDoes Not table for values. 402.2.2, 402.2.E ❑ Steel i D Steel i❑Not Observable [HIT ;❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies , 303.2 manufacturer's instructions. ❑Does Not [Fl2]1 Blown insulation marked every 300 ft2. ['Not Observable ONot Applicable 402.2.3 Vented attics with air permeable ❑Complies [F122j2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.2.4 'Attic access hatch and door R- R- :❑Compiles [FI3j1 insulation >_R-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 ;Blower door test @ 50 Pa. <=5 : ACH 50= ' ACH 50= ;❑Complies [F117]1 ach in Climate Zones 1-2,and ❑Does Not <=3 ach in Climate Zones 3-8. ['Not Observable ❑Not Applicable 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ;❑Complies [F14]1 Liin/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100-ft2 without air l handler @ 25 Pa.For rough-in ❑Nat Observable tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ;❑Complies [F12711 'determine air leakage with ft2 ft2 >❑Does Not ;either:Rough-in-test:Total- 'leakage measured with a ❑Nat Observable pressure differential of 0.1 inch ❑Not Applicable w.g.across the system including the manufacturer's air handler enclosure if installed at time of test.Pastconstruction.test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure.. , 403.3.2.1 :Air handler leakage designated ❑Complies [F124]3- 'by manufacturer at<=2%of '❑Does.Not design air flow. ['Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [Ff9]2 installed for control of primary . ❑Does Not heating and cooling systems and , initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [Fi10]2 on heat pumps. ❑Does Not QNot Observable ❑Not Applicable j 403.5.1 Circulating service hot water ❑Complies [F111]2 systems have automatic or '❑Does Not accessible-manual controls. ['Not Observable ❑Not Applicable 1 High Impact(-Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title:Taft- Report-date: 04/03/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\70 Richmond Hill Drive.rck Page 7 of 9 Section Plans Verified Field Verified Final Inspection Provisions Valueer Value Complies? Comments]Assumptions 403.6.1 All mechanical ventilation system OComplies [FI2512 fans not part of tested and listed ODoes Not HVAC equipment meet efficacy and airflow limits. DNot Observable ['Not Applicable ; 403.2 Hot water boilers supplying heat DComplies I[F126}2 through one-or two-pipe heating ODoes Not systems have outdoor setback ['Not Observable control to lower-boiler water temperature based on outdoor DNot Applicable temperature. 403.5.1.1 Heated water circulation systems' OComplies [F128j2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply. DNot Observable pipe.Gravity and thermos- DNot Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no-demand for hot water exists. 403.5.1.2 Electric heat trace systems- DCornplies- [F12912 comply with IEEE 515,1 or UL ODoes Not 515.Controls automatically adjust the energy input to the DMA Observable heat tracing to maintain the DNot Applicable desired watertemperature in the piping. 403.5.2 Water distribution systems that OComplies. [FI3012 have recirculation pumps that ODoes Not pump water from a heated water supply pipe back to the heated ['Not Observable water-source through-a cold ONot Applicable water supply pipe have a. demand recirculation water system,Pumps have controls that manage operation of the pump and limit the temperature ; of the water entering the cold water piping to 104°F, 403.5.4 Drain water heat recovery units DComplies [F131}2 tested in accordance with CSA ODoes Not B55.1.Potable water-side pressure loss of drain waterheat DNot Observable recovery.units.<3 psi for DNot Applicable individual units connected to one or two showers.Potable water- side pressure loss of drain water heat recovery units<2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent OComplies [Fl6p- fixtures or 75%of permanent ODoes Not ;fixtures have high efficacy lamps. - Does not apply to low-voltage Not Observable lighting. ONot Applicable 404.1.1 Fuel gas lighting systems have DComplies [F123}3 no continuous pilot light. - DDoes.Not J ONot Observable ONot Applicable 1 High Impact(Tier 1) - 2- Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title:Taft- Fteportdate:- 04/03/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\70 Richmond Hill Drive.rck Page 8 of 9 Sectie lie �® Final inspection Provisions j .la F9�uefraed FaeldV�aset6ed p= Complies? Comments/Assumptions f �401.3 Compliance certificate posted. ❑Complies [97]z ❑Does Not ❑Not Observable ❑Nat Applicable 3033 Manufacturer manuals for ❑Complies [FIl8]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low impact(Tier 3) Project-Title:Ta(L" Report-date: 04/03/19 Data filename: C:\Users\jkazi\OneDrive\Documents\REScheck\70 Richmond Hill Drive.rck Page 9 of 9 F (ts% (2y6,Hi _ L - (OO ©ay, " L L DILJ quittifillikapr 44,714i e„, Above-Grade Wall 21.00 Below-Grade Wall 24.00 Floor 30.00 Ceiling/Roof 49.00 Ductwork(unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 030 Door 0.19 „ gmewal &opoiNeKT 0 -pp4, Heating System: Cooling System: Water Heater: `1. A Name: Date: Comments