footing letter ".[ Er ______iCEEIWIE [5 I-IODOROWSKI MAY 03 2019 fi0M Es IBUILDING ON TRADITION TOWN OF QUEENSBURY BUILDING&CODES i FILE COPY May 2, 2019 Town of Queensbury Building Department 742 Bay Road Queensbury, NY 12804 Re: Barringer Heights Subdivision To Whom It May Concern, With any new homes in the Barringer Heights Subdivision, Hodorowski Homes will set the bottom of footings a minimum of 3'-0" above the mottling height, as defined by the Site Drawings by Nace Engineering/Van Dusen and Steve's Land Surveyors, dated November 2005. A benchmark will be set at a hydrant to confirm elevations. Instead of the RC-2 asphalt damp proofing, we will coat the concrete foundation wall, below grade, with a Polymer-Modified Asphalt coating, a minimum of 40 mils, per IRC 2015—Section R406.2. The product is called Tuff-N-Dri, by Tremco. The insulated boards are optional, and not required by code. Lastly, Hodorowski Homes uses Appolo Heating and Cooling to perform all of our blower door tests. They will issue a signed and certified notice,once we pass and achieve 3.0 ach or less per IRC 2015. Since ely, ~ rnstan Hodorowski