inspection 06062019INSPECTION WORKSHEET (BINS-003366-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0238-2019Case Module:Permit
Inspection Date:Thu Jun 6, 2019Inspection Status:Partial Pass
Inspector:Mark SmithInspection Type:Building Foundation
Job Address:40 JOHN CLENDON RDParcel Number:295.15-2-4.1
Queensbury, NY 12804
Contact TypeCompany NameName
ContractorFOOTHILLS BUILDERS, LLC
ApplicantJohn Clendon Hidden Estates LL
Granted PermissionFOOTHILLS BUILDERS, LLC
EngineerVision Engineering
Primary OwnerFOOTHILLS BUILDERS, LLC
Checklist ItemPassedComments
Building Inspector NotesNO5/22/19 footings approved
5/30/19 foundation walls approved
6/6/19 poly under slab verified
PiersNO
Monolithic SlabNO
Reinforcement in PlaceNO2 rows of #4 rebar continuous
Verticals to be wet set
Foundation / WallpourNO5/30/19 foundation walls approved
Reinforcement in PlaceNO2 rows of #4 rebar horizontal, 12" from top and bottom of wall
Jun 06, 2019Page (1)
INSPECTION WORKSHEET (BINS-003366-2019)
Checklist ItemPassedComments
Footing Dowels or Keyway in placeNO#4 rebar 48" on center 24" above footings
Foundation DampproofingNO
Foundation WaterproofingYES5/31/19
Footing Drain Daylight or SumpNONot observed at time of inspection
Footing Drain Stone - 12 inch widthNO
Footing Drain Stone - 6 inches above footingNO
Footing Drain stone - 6 mil polyNO
Backfill ApprovalYES5/31/19
Plumbing Under SlabNO
PVC / Cast / CopperNO
Foundation Insulation Interior / ExteriorNO
Rough Grade 6 inch drop within 10 ft.NO
Poly Under SlabYESPoly's blown all over the place 6/3/19
6/6/19 poly under slab verified
Smith, Mark (Inspector)
Jun 06, 2019Page (2)