HVAC Li ; I APR 2 6 2019 ' II 'I
126 Richmond Hills Dr
HVAC Load Calculations
for
Hodorowski
308.7-1-78 RC-0252-2019
Hodorowski Homes
126 Richmond Hill Dr, Lot 31
SFD w/gas FP 2254 s.f., Gar. 546 s.f.
El
,.
.,
ei, „
a ,A , ,„ l
„ .
, ,
R NvAcHVAC LoArts
RZSIDENTIAL
Prepared By:
Nick Abrunza
Appolo Heating
868 Burdeck St
Schenectady Ny 12306
Thursday, April 25, 2019
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heating Inc. 126 Richmond Hills Dr
Schenectady,NY 12306 Page 2
Project Report
General Project Information
Project Title: 126 Richmond Hills Dr
Designed By: Hodorowski
Project Date: Thursday, April 25, 2019
Client Name: Hodorowski
Company Name: Appolo Heating
Company Representative: Nick Abrunza
Company Address: 868 Burdeck St
Company City: Schenectady Ny 12306
Design Data
Reference City: Schenectady, New York
Building Orientation: Front door faces North
Daily Temperature Range: Medium
Latitude: 42 Degrees
Elevation: 378 ft.
Altitude Factor: 0.986
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: 1 0.31 n/a n/a 70 n/a
Summer: 87 72 49% 50% 75 30
Check Figures
Total Building Supply CFM: 1,271 CFM Per Square ft.: 0.352
Square ft. of Room Area: 3,617 Square ft. Per Ton: 1,400
Volume (ft3): 31,559
Building Loads
Total Heating Required Including Ventilation Air: 64,050 Btuh 64.050 MBH
Total Sensible Gain: 27,590 Btuh 89 %
Total Latent Gain: 3,407 Btuh 11 %
Total Cooling Required Including Ventilation Air: 30,997 Btuh 2.58 Tons (Based On Sensible+ Latent)
Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\126 Richmond Hill Dr.rh9 Thursday, April 25, 2019, 7:25 AM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heating Inc. 126 Richmond Hills Dr
Schenectady,NY 12306 Page 3
Miscellaneous Report
System 1 Outdoor Outdoor Outdoor Indoor Indoor Grains
Input Data Dry Bulb Wet Bulb Rel.Hum Rel_Hum Dry Bulb Difference
Winter: 1 0.31 80% n/a 70 n/a
Summer: 87 72 49% 50% 75 29.96
Duct Sizing Inputs
Main Trunk Runouts
Calculate: Yes Yes
Use Schedule: Yes Yes
Roughness Factor: 0.00300 0.01000
Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft.
Minimum Velocity: 0 ft./min 0 ft./min
Maximum Velocity: 900 ft./min 750 ft./min
Minimum Height: 0 in. 0 in.
Maximum Height: 0 in. 0 in.
Outside Air Data
Winter Summer
Infiltration Specified: 0.370 AC/hr 0.190 AC/hr
195 CFM 100 CFM
Infiltration Actual: 0.370 AC/hr 0.190 AC/hr
Above Grade Volume: X 31.559 Cu.ft. X 31,559 Cu.ft.
11,677 Cu.ft./hr 5,996 Cu.ft./hr
X 0.0167 X 0.0167
Total Building Infiltration: 195 CFM 100 CFM
Total Building Ventilation: 0 CFM 0 CFM
---System 1---
Infiltration &Ventilation Sensible Gain Multiplier: 13.02 = (1.10 X 0.986 X 12.00 Summer Temp. Difference)
Infiltration &Ventilation Latent Gain Multiplier: 20.09 = (0.68 X 0.986 X 29.96 Grains Difference)
Infiltration &Ventilation Sensible Loss Multiplier: 74.87 = (1.10 X 0.986 X 69.00 Winter Temp. Difference)
Winter Infiltration Specified: 0.370 AC/hr(195 CFM), Construction: Average
Summer Infiltration Specified: 0.190 AC/hr(100 CFM), Construction: Average
C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\126 Richmond Hill Dr.rh9 Thursday, April 25, 2019, 7:25 AM
F
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heating Inc. 126 Richmond Hills Dr
Schenectady,NY 12306 Page 4
Load Preview Report ii
C SA Sy
Net ft.f Sen Lat Ne Sen Ht cl Actl Duct
Scope Ton /To Area Gain Gain Gei . Los1 CFMSy CFM 1 CFM CFM1 Size
Building 2.58 1,400 3,617 27,590 3,407 30,997 64,050 843 1,271 1,271
System 1 2.58 1,400 3,617 27,590 3,407 30,997 64,050 843 1,271 1,271 12x1E
Zone 1 3,617 27,590 3,407 30,997 64,050 843 1,271 1,271 12x1E
1-Basement 1,296 2,629 586 3,215 15,441 203 121 121 2--5
2-Great Room 380 2,275 215 2,490 7,181 95 105 105 1--7
3-Home Office 156 1,870 117 1,987 3,665 48 86 86 1--6
4-Two Story Foyer 77 1,402 83 1,485 2,506 33 65 65 1--6
5-Dining 169 1,962 150 2,112 4,284 56 90 90 1--6
6-Powder Room 36 472 0 472 297 4 22 22 1--4
7-Nook 192 1,513 56 1,569 3,021 40 70 70 1--6
8-Kitchen 180 1,763 126 1,889 3,998 53 81 81 1--6
9-Mud Room 66 1,173 80 1,253 2,229 29 54 54 1--5
10-Master Bath 91 1,187 83 1,270 2,354 31 55 55 1--5
11-Master Suite 252 3,303 883 4,186 5,856 77 152 152 2--6
12-1MC 117 808 37 845 1,700 22 37 37 1--5
13-Bath 1 72 669 25 694 1,120 15 31 31 1--4
14-Bedroom 2 156 2,458 454 2,912 3,695 49 113 113 2--5
15-Bedroom 3 169 2,557 483 3,040 4,279 56 118 118 2--5
16-Loft/Hall 159 937 0 937 1,499 20 43 43 1--5
17-WIC 2 49 612 29 641 925 12 28 28 1--4
C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\126 Richmond Hill Dr.rh9 Thursday, April 25, 2019, 7:25 AM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heating Inc. "C 126 Richmond Hills Dr
Schenectady,NY 12306 Page 5
Duct Size Preview
Room or Source Minimum Maximunj Rough] Desig I SP Ducil Ducti Htg CI g Act. Duct
Duct Name Velocit} Velocitt Factor L/10q Lost Velocit Length Flow Flow Flow Size
System 1
Supply Runouts
Zone 1
1-Basement Built-In 0 750 0.01 0.1 444.2 203i 1211 121 2--5
2-Great Room Built-In 0 750 0.01 0.1 392.3 95';______105'' 105 1--7
3-Home Office Built-In 0 750 0.01 0.1 439 48 . 86i 86 1--6
4-Two Story Foyer Built-In 0 750 0.01 0.1 329 33 65 65 1--6
5-Dining Built-In 0 750 0.01 0.1 460.6 56i 90i 90 1--6
6-Powder Room Built-In 0 750 0.01 0.1 249 4� 22 22 1-4
7-Nook Built-In 0 750 0.01 0.1 355 40 _ 70: 70 1--6
8-Kitchen Built-In 0 750 0.01 0.1 413.8 53' 81'; 81 1--6
9-Mud Room Built-In 0 750 0.01 0.1 396.3 29, 54' 54 1--5
10-Master Bath Built-In 0 750 0.01 0.1 401.1 31 55 55 1--5
11-Master Suite Built-In 0 750 0.01 0.1 387.6 77'' 152' 152 2--6
12-WC Built-In 0 750 0.01 0.1 273 22! 37!', 37 1--5
13-Bath 1 Built-In 0 750 0.01 0.1 353.2 15'i 31 31 1--4
14-Bedroom 2 Built-In 0 750 0.01 0.1 415.4 49. 113', 113 2--5
15-Bedroom 3 Built-In 0 750 0.01 0.1 432.2 56 118, 118 2--5
16-Loft/Hall Built-In 0 750 0.01 0.1 316.7 20 _43, 43 1--5
17-WIC 2 Built-In 0 750 0.01 0.1 323 12' 28! 28 1--4
Other Ducts in System 1
Supply Main Trunk Built-In 0 900 0.003 0.1 847.6 843 1,271 1,271 12x1E
Summary
System 1
Heating Flow: 843
Cooling Flow: 1271
C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\126 Richmond Hill Dr.rh9 Thursday, April 25, 2019, 7:25 AM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heating Inc. '3 126 Richmond Hills Dr
Schenectady,NY 12306 Page 6
Total Building Summary Loads
Component Area Sen Lat Sen Total
Description Quan. Loss Gain Gain Gain
Plygem Pro: Glazing-Plygem Pro, U-value 0.33, SHGC 245.6 5,591 0 3,272 3,272
0.28
Front Door: Door-Front Door Generic, U-value 0.19 20.4 267 0 89 89
Pella Slider: Door-Pella Slider, U-value 0.3 40.8 845 0 282 282
Fire Rated: Door-Fire Door Generic, U-value 0.28 20.4 394 0 131 131
12C-0bm: Wall-Frame, R-13 insulation in 2 x 4 stud 1128 8,950 0 1,168 1,168
cavity, no board insulation, brick finish, metal studs, U-
value 0.115
12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, 2407.6 10,799 0 1,925 1,925
no board insulation, siding finish,wood studs, U-value
0.065
16B-38: Roof/Ceiling-Under Attic with Insulation on Attic 1387.6 2,489 0 1,697 1,697
Floor(also use for Knee Walls and Partition Ceilings),
Vented Attic, No Radiant Barrier, Dark Asphalt
Shingles or Dark Metal, Tar and Gravel or
Membrane, R-38 insulation, U-value 0.026
21A-24: Floor-Basement, Concrete slab, any thickness, 2 1296 2,236 0 0 0
or more feet below grade, no insulation below floor,
any floor cover, shortest side of floor slab is 24'wide,
U-value 0.025
19A-Ocp: Floor-Over enclosed crawl space, No insulation 2055.6 15,718 0 2,732 2,732
on exposed walls, sealed or vented space, passive,
no floor insulation, carpet or hardwood, U-value 0.295
19A-Otp: Floor-Over enclosed crawl space, No insulation 265 2,189 0 381 381
on exposed walls, sealed or vented space, passive,
no floor insulation, tile or vinyl, U-value.._0.368
Subtotals for structure: 49,478 0 11,677 11,677
People: 4 1,400 1,800 3,200
Equipment: 0 0 0
Lighting: 3580 12,208 12,208
Ductwork: 0 0 0 0
Infiltration: Winter CFM: 195, Summer CFM: 100 14,572 2,007 1,301 3,308
Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0
AED Excursion: 0 0 604 604
Total Building Load Totals: 64,050 3,407 27,590 30,997
I Check Figures
Total Building Supply CFM: 1,271 CFM Per Square ft.: 0.352
Square ft. of Room Area: 3,617 Square ft. Per Ton: 1,400
Volume (ft3): 31,559
Building Loads
Total Heating Required Including Ventilation Air: 64,050 Btuh 64.050 MBH
Total Sensible Gain: 27,590 Btuh 89 %
Total Latent Gain: 3,407 Btuh 11 %
Total Cooling Required Including Ventilation Air: 30,997 Btuh 2.58 Tons (Based On Sensible+ Latent)
Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\126 Richmond Hill Dr.rh9 Thursday, April 25, 2019, 7:25 AM
s
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appolo Heating Inc. 126 Richmond Hills Dr
Schenectady,NY 12306 Page 25
System '1 Room Load Summary
Htg Min Run Run Clg Clg Min Act
Room Area Sens Htg Duct Duct Sens Lat Clg Sys
No Name SF Btuh CFM Size Vel Btuh Btuh r CFM CFM
---Zone 1---
1 Basement 1,296 15,441 203 2-5 444 2,629 586 121 121
2 Great Room 380 7,181 95 1-7 392 2,275 215 105 105
3 Home Office 156 3,665 48 1-6 439 1,870 117 86 86
4 Two Story Foyer 77 2,506 33 1-6 329 1,402 83 65 65
5 Dining 169 4,284 56 1-6 461 1,962 150 90 90
6 Powder Room 36 297 4 1-4 249 472 0 22 22
7 Nook 192 3,021 40 1-6 355 1,513 56 70 70
8 Kitchen 180 3,998 53 1-6 414 1,763 126 81 81
9 Mud Room 66 2,229 29 1-5 396 1,173 80 54 54
10 Master Bath 91 2,354 31 1-5 401 1,187 83 55 55
11 Master Suite 252 5,856 77 2-6 388 3,303 883 152 152
12 WIC 117 1,700 22 1-5 273 808 37 37 37
13 Bath 1 72 1,120 15 1-4 353 669 25 31 31
14 Bedroom 2 156 3,695 49 2-5 415 2,458 454 113 113
15 Bedroom 3 169 4,279 56 2-5 432 2,557 483 118 118
16 Loft/Hall 159 1,499 20 1-5 317 937 0 43 43
17 WIC 2 49 925 12 1-4 323 612 29 28 28
System 1 total 3,617 64,050 843 .....___ 27,590 3,407 1,271 1,271___
System 1 Main Trunk Size: 12x18 in.
Velocity: 848 ft./min
Loss per 100 ft.: 0.099 in.wg
Cooling System Summary
Cooling Sensible/Latent Sensible Latent Total
Tons. Split Btuh Btuh Btuh
Net Required: 2.58 89%/11% 27,590 3,407 30,997
Actual: 3.42 75%/25% 30,750 10,250 41,000
Equipment Data
Heating System Cooling System
Type: Natural Gas Furnace Standard Air Conditioner
Model: ML195UH090XP36C-* 13ACXN042-230-**
Indoor Model: C35-48B+TDR+TXV
Brand: MERIT 90 MERIT 13ACX SERIES
Description: Natural Gas or Propane Furnace
Efficiency: 95 AFUE 13 SEER
Sound: 0 0
Capacity: 85,000 Btuh 41,000 Btuh
Sensible Capacity: n/a 30,750 Btuh
Latent Capacity: n/a 10,250 Btuh
AHRI Reference No.: n/a 8269541
C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\126 Richmond Hill Dr.rh9 Thursday, April 25, 2019, 7:25 AM
->7
FV-11VQL6-PanasonicB2C Page 1 of 3
•
BULK ORDERS LOGIN SUPPORT ORDER STATUS
ABOUT FOR BUSINESS FOR INDUSTRY Enter model,category or keyword
CAMERAS+CAMCORDERS AUDIO+VIDEO MICROWAVE+KITCHEN TELEPHONES PERSONAL CARE MASSAGE HOME+OFFICE NEW!
DEALS FREE SHIPPING ON ALL ORDERS
Home Home+Office Power Tools&Ventilation Ventilation Systems Ceiling Insert Fans FV-11VQL6
WhisperLite TM Fan/Light - Quiet, Sp(
rn., Ventilation Solution, 110 CFM
FV-11 VQ L6
write a review
�.d
Features
• Quiet,yet powerful—ideal for new and remodel residential applications
• (2)13W self ballasted GU24 base CFL lamps and a 4W night light
• Integrated dual 4"or 6"duct adapter on 80-110 CFM models
• Fits in 2 x 8 construction
• UL listed for tub/shower enclosure when used with a GFCI protected circuit
• Can be used to comply with ASHRAE 62.2,LEED,IAP,California Title 24 and I•
Ventilation Code
• Total order can not exceed 4 Vent Fans.Otherwise,order will be cancelled.
$367.00
In Stock / Ships In 1-3 Business Days
1 ADD TO CART
Add a Protection Plan Details+
Select a Plan
ADD TO REGISTRY
Features Support
WhisperLite FV-11VQL6 110 CFM,Ceiling Mount Fan/Light
The workhorse of the Panasonic line,WhisperLite^"is time-tested and customer approved for its quiet,yet powerful consistency.Rated for continuous use,WhisperLite
vent fans are a simple way to incorporate an energy efficient ventilation strategy,and are a great choice for new and remodel residential applications.
We Set the Standard for Quiet Operation
WhisperLite features a totally enclosed condenser AC motor and a double-tapered blower wheel to quietly move air-even at twice the static pressure as the industry
standard.WhisperLite exceeds the performance measurement for ASHRAE 62.2,ENERGY STAR®3.0,and LEED for Homes.
Long Life Means Reduced Costs
When you have a household or business to run,you don't want to have to replace little things like a vent fan.Panasonic fan/light combinations useless energy to move
larger volumes of air than other brands.Consequently,Panasonic fans run cooler so they last longer.They are also much less likely to overheat and result in motor
failure.The motor is also equipped with a thermal-cutoff fuse.
http://shop.panasonic.com/home-and-office/power-tools-and-ventilation-systems/ventilatio... 1/19/2017
FV-11VQL6-PanasonicB2C Page 2 of 3
CFL Lighting Efficiency
Energy efficient lighting is an important part of the latest codes and standards,so Panasonic fans incorporate the most efficient CFL lamps available.Our flush mount
grilles incorporate(2)13W,self-ballasted GU24 base,ENERGY STAR rated CFL lamps that squeeze out more lumens per watt(greater than 70 LPW!)than other
manufacturers'do.A 4-watt night light is also included.unable to display
Installation Flexibility
WhisperLite incorporates an integrated dual 4 in.or 6 in.duct adapter to give you flexibility in duct layout and design.For short runs,you can go with a smaller duct
size,but long runs are OK,too-just move up to 6 in.duct.The double hanger-bar system(expandable up to 24 in.)is ideal for positioning the fan exactly where you
want it.Panasonic fan/light combinations are also UL listed for tub/shower enclosure(just install them on a GFCI-protected circuit).With these great features,your
installation options open up.
ENERGY STAR®Certified for Energy Savings
Panasonic ventilation fans are ENERGY STAR®certified,where guidelines exist.ENERGY STAR®vent fans meet strict parameters set by the US Environmental
Protection Agency(EPA).They provide better efficiency and comfort with less noise,and feature high performance motors and improved blade design,providing better
performance and longer life.
FAQS
What support content is available for my product?
CONTACT INFORMATION
Consumer Product Support and Technical Assistance
Panasonic Community
Support Live Chat
Operating hours:
Mon-Fri 9am-9pm EST
Sat-Sun 10am-7pm EST
http://shop.panasonic.com/home-and-office/power-tools-and-ventilation-systems/ventilatio... 1/19/2017