Loading...
ResCheck REScivek Softtyare Version 4® t a� Ls -f' I .1 t Compliance Certificate E� AIR 26 2019 DI. .1 i OWN OF r iUUE NSBi;R e Project Saratoga Energy Code: 2015 IECC 308.7-1-78 RC-0252-2019 Location: Glens Falls, New York Hodorowski Homes Construction Type: Single-family 126 Rich Hill Dr Lot 31 Project Type: New Construction Conditioned Floor Area: 2,254 ft2 SFD w/gas mond FP 2254 s.f., , Gar. 546 s.f. Glazing Area 10% ---------------- Climate Zone: 6 (7635 HDD) Permit-Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 126 Richmond Hills Drive Hodorowski Homes Northstar Home Design, LLC Queensbury,NY ,:CIMVIrtet'at4pes usi .LiA trade off Compliance: 2.2%®Better Than Code Maximum UA: 320 Your UA: 313 The%Better or Worse Than Code Index reflects how dose to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter Ceiling 1:Raised or Energy Truss. 1,312 49.0_ 0.0 0.020 .76 Wall 1:Wood Frame, 16"o.c. 2,842 21.0 0.0 0.057 143 Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 244 0.300 73 Door 1:Solid 51 0.190 10 Door 2:Glass 40 0.300 12 Basement Wall 1:Solid Concrete or Masonry 1,280 19.0 5.0 0.037 47 Wall height:8.0' Depth below grade:7.0' Insulation depth:8.0' Floor 2:All-Wood joist/Truss:Over Outside Air 48 30.0 0.0 0.033 2 Compliance Statement: The proposed building,design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck.Version.4.6.5.and to_comply with the mandatory requirements listed in tti_, -- -r_k inspection Checklist. 04.„ Name-Title Signature ; 0. Date a . 1 ar " 1% C _ , Project Title: Saratoga Report date: 04/14/19 Data filename:C:\Users\)kaz1\OneDrive\Documents\REScheck\126 Richmond Hills•Drive.rck Page 1 of 9 the ck Software V- rsion C6.5 �� x°,kii :I inspection Checklist am Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the"Comments/Assumptions""column is provided by the user in the REScheck Requirements screen.For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table,a reference to that table is provided_ Section Plans Verified Field Verified # Pre-inspecti h,n/Plan Review Value Value Complies? Comments/Assumptions & Req.11 103.1, Construction drawings and DComplies 103.2 documentation demonstrate EiDoes Not [PR111 energy code compliance for the ['Not Observable building envelope.Thermal envelope represented on Applicable construction documents. 103.1, Construction drawings and ElComplies 103.2, documentation demonstrate l]Does Not 403.7 energy code compliance for [PR3J' ,lighting and mechanical systems. �Nnt Observable Systems serving multiple (�IVOt Applicable dwelling units must demonstrate 'compliance with the IECC Commercial.Provisions.. 1302.1, Heating and cooling equipment is; Heating: ' Heating: ,UComplies 403.7 sized per ACCA Manual S based ' Btu/hr Btu/hr ;l]Does Not [PR212 on loads calculated per ACCA ' Cooling: Coolie -t, Manual J or other methods ; Btu/hr Btu/hrg: EJNot ObseApplicable e { approved by the code official. l]Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 I Low Impact(Tier 3) Projett-Tille.Saratoga Report date: 04/14/19 Data filename: C:\Users\jkaz1\OneDrive\Documents\REScheck\126 Richmond Hills Drive.rck Page 2 of 9 SectionPlans verified Field Verified FoundationInspection value ValueC��piie�� C. menu/Assumptions _e_.l0 1 402.1.1 Conditioned basement wall ' R- ; R- OComplies See the Envelope Assemblies [F0411 ;insulation R-value.Where interior R_ R- ODoes Not table for values. insulation is used;verification ;may need to occur during ;ONot Observable Insulation.Inspection.N.ot. Observable,_, Applicable ; 'required in warm-humid locations in Climate Zone 3. 303.2 ;Conditioned basement wall ['Complies [FO5j1 ;insulation installed per ['Does Not manufacturers instructions. • ;['Not Observable ;['Not Applicable i 402.2.9 Conditioned basement wall ft ft ;['Complies See the Envelope Assemblies [FOsjl insulation depth of burial or Oboes Not :table for values. distance from top of wall. iONot Observable ['Not Applicable ; 303.2.1 A protective covering is installed ;['Complies [F01112 to protect exposed exterior ['Does Not insulation and extends a � minimum of 6 in.below grade. • ;ONot Observable ;['Not Applicable &403.9 Snow-and ice-melting system ['Complies [F01212 controls installed. ' Does Not `; ONot.Observable. jDNot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project-Title:Sal dtuga Report dale: 04/14/19 Data filename: C:\Users\jkazi\OneDrive\Documents\REScheck\126 Richmond Hills Drive.rck Page 3 of 9 SectionPlans Verified field Verified Framing/"oegh-ln inspection Value ValueComplies? Comments/Assumptions &RegolD 402.1.1, Door U-factor. U- U- 'OComplies 'See the Envelope Assemblies 402.3.4 ['Does Not table for values. [FRl]i ['Not Observable ; ONot Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ,OComplies ,See the Envelope Assemblies 402.3.1, ,average). QDoes Not ;table for values. 402.3.3, 402.5 ['Not Observable [-FR2]1 ONot Applicable 303.1.3 U-factors of fenestration products !]Complies [ [FR4]1 are determined in accordance QDoes Not with the NFRC test procedure or ' taken from the default table. ['Not Observable ONot Applicable 402.4.1.1 Air barrier and thermal barrier OComplies [FR23]1 installed permanufacturer's ❑Does Not , instructions. ONot Observable ONot Applicable 402.4.3 Fenestration that is not site built OComplies [FR2O]1 is listed and labeled as meeting QDoes Not AAMA/WDMA/CSA 1O3/1.5.2/A440 or has infiltration rates per NFRC ONot Observable 400 that do not exceed code ONot Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ,OComplies [FR16]2 sealed at housing/interior finish QDoes Not and labeled to indicate s2.0 cfm leakage at 75 Pa. ONot Observable ONot Applicable 403.3.1 ;Supply and return ducts in attics []Complies [FR12]3- 'insulated>=R-8 where duct is QDoes Not >=3 inches in diameter and> R-6 where<3 inches.Supply and, ONot Observable return ducts in other portions of []Not Applicable 'the building insulated>=R-6 for diameter>=3 inches and R-4.2 for<3-inches in diameter. 403.3.5 ;Building cavities are not used as ;[3Cun Fillies [FR1513 ducts or plenums. QDoes Not ['Not Observable ONot Applicable 403.4 'HVAC piping conveying fluids ; R- R- , Complies [FR1712 above 105°F or chilled fluids QDoes Not below 55.°F are insulated to_>R- _. 3 y, ONot Observable []Not Applicable 403.4.1 'Protection of insulation on HVAC []Complies [FR24]1 piping. QDoes Not ['Not Observable IONot Applicable 403.5.3 Hot water pipes are insulated to ; R- R- :[]Complies [FR18]2 -R-3. ;QDoes Not x ' ;[]Not Observable []Not Applicable 403.6 Automatic or gravity dampers are []Complies [FR1912 installed on all outdoor air QDoes Not intakes and exhausts. [(Not Observable []Not Applicable 1 High impact(Tier 1) 2 Medium Impact(Tier 2) 3 I Low impact(Tier 3) Project Title: Sardloga Repo rl dale: 04/14/19 Data filename: C:\Users\jkazi\OneDrive\Documents\REScheck\126 Richmond Hills Drivesck Page 4 of 9 Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 'Medium Impact(Tier 2) 3 !Low Impact(Tier 3) Project-Title:SdFdluga Report dale: 04/14/19 Data filename: C: Users\jkaz1\OneDrive\Documents\REScheck\126 Richmond Hills Drive.rck Page 5 of 9 • Section insulation inspection Pia eas.Verified Field Verified Complies? t. Value Value Reo.l Complies Comments/Assumptions 303.1 All installed insulation is labeled ❑Complies [1N13}2 or the installed R-values ODoes Not provided. ONot Observable t ONot Applicable 402.1.1, 'Floor insulation R-value. ' R- ; R- OComplies See the Envelope Assemblies 402.2.6 Q.Wood ;O Wood ODoes Not ;table for values. [1N1}1 O Steel O Steel 'ONot Observable Yi ONot Applicable 303.2, Floor insulation installed per OComplies 402.2.7 manufacturer's instructions and ODoes Not [IN2}1 in substantial contact with the underside of the subflOor,or floor` ONot Observable framing cavity insulation is in ONot Applicable contact with the top side of sheathing,or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value.If this is a; R- R- ;OComplies See the Envelope Assemblies 402.2.5, mass wall with at least'/i of the Q Wood Q Wood ODoes Not table for values. 402.2.6 wall insulation on the-wall O Mass ❑ Mass ;ONot Observable [IN3}1 ;exterior,the exterior insulation Steel Steel requirement applies(FRIO). ONot Applicable 303.2 'Wall insulation is installed per ;OComplies [1N4P- ;manufacturer's instructions. Oboes Not ONot Observable ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Saratoga Repot elate: 04f 14119 Data filename: C:tUsers\jkaz]. OneDrive\Documents\REScheck\126 Richmond Hills Drive.rck Page 6 of 9 Section Maras VerifiedField verified # Final Inspection Provisions value Vague Complies? Commeaats/Assumptions & Regal" 402.1.1, Ceiling insulation R-value. R- ; R- ❑Complies 'See the Envelope Assemblies 402.2.1, O Wood ❑ Wood ODoes Not 'table for values. 402.2.2, Steel 402:2.5 ❑ ❑ Steel ❑Not Observable [FI1j1 ONot Applicable 303.1.1.1, 'Ceiling insulation installed per '❑Complies 303.2 manufacturer's instructions. ODoes Not [FI2j1 ;Blown insulation marked every 300 ft2 Not Observable ❑Not Applicable 1 402.2.3 Vented attics with air permeable ❑Complies [F122]2 insulation include baffle adjacent Oboes Not to soffit and eave vents that extends over insulation. [Not Observable ONot Applicable 402.2.4 'Attic access hatch and door R- R- ;OCbmplies [FI3]1 ;insulation __R-value of the ODoes Not adjacent assembly. ❑Nat Observable ❑Not Applicable 402.4.1.2 :Blower door test @ 50 Pa. <=5 ACH 50= ACH 50= ;❑Complies [F117j1 ach in Climate Zones 1-2,and Oboes Not <=3-ach in Climate-Zones 3-8. ❑Not Observable ❑Nat Applicable 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ;❑Complies [F14j'- din/I00 ft2 across the system or ft2 ' ft2 :❑Does Not <=3-tfni/-100-ft2-without air handler.@.25.Pa. For rough-in ❑Not Observable ,tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.3 ;Ducts are pressure tested to cfm/100 cfm/100 ;❑Complies [9271' ;determine air leakage with ft2 ft2 'CI Does Not either:Rough-in test:-Total leakage measured with a ;❑Not Observable pressure differential of 0.1 inch Observable,__, Applicable w.g.across the system including 'the manufacturer's air handler enclosure if installed attime of test_.Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including-the-manufacturer's air handler enclosure. , 403.3.2.1 ;Air handler leakage designated ❑Complies [F12411 by manufacturer at<=2%of ❑Does.Not •design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [FI9F installed for control of primary Does Not heating and cooling systems and initially set by manufacturer to Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed OComplies [F11012 on-heat pumps. ;Oboes Not ❑Not Observable ❑Not Applicable❑Complies 403.5.1 Circulating service hot water [F11112 systems have automatic or Oboes Not accessible Manual controls. ❑Not Observable ; ❑Not Applicable 1 High Impact(Tier 1)- 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title.Sdrdlciga- Reporttddle: 04/1-4/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\126 Richmond Hills Drive.rck Page 7 of 9 Section Plans Verified) Field Verified k Final Inspection Provisions Valueo Complies? Coemments/Assumptions Value 1& `egolDi 403.6d All mechanical ventilation system: DComplies I[F125]2 fans not part of tested and listed ! ❑Does Not HVAC equipment meet efficacy and air flow limits. ❑Not Observable ❑Not Applicable ,403.2 Hot water boilers supplying heat F UJComplies 1[FI26]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower-boiler water ONot Observable temperature based on-outdoor UNot Applicable temperature. 403.5.1.1 Heated water circulation systems: DComplies [Ft28]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated ! return pipe or a cold water supply Not Observable ; pipe.Gravity and thermos- UNot Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand withinthe :- occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. .403.5.1.2 Electric heat trace-systems DComplies [F129]2 comply with IEEE 515.1 or UL QDoes Not 515.Controls automatically adjust the energy input to the UNot Observable heat to maintain the L] tci Not Applicable desired watertemperature in the ; S piping. 403.5.2 Water distribution systems that QComplies. [F130]2 have recirculation pumps that ElDoes Not pump water from a heated water [ Not Observable supply pipe back to the heated water source-through a cold ❑Not Applicable water supply pipe have a demand recirculation water - system. Pumps have controls that manage operation of the - pump-and limit the-temperature- of the water entering the cold water piping to 104°F. - - - 403.5.4 Drain water heat recovery units - DComplies [FI31]2 tested in accordance with CSA DDoes Not B55.1.Potable water-side pressure loss of drain water heat ' ❑Not Observable recovery units<3 psi for - - ❑Not Applicable individual units connected to one - or two showers.Potable water- side pressure loss of drain water - heat recovery units<2 psi for individual units connected three or more showers. 404.1 .75%of lamps in permanent DComplies [F16] fixtures or 75%of permanent - QDoes Not fixtures have high efficacy lamps. Does not apply-to-low-voltage Not Observable lighting. - QNot Applicable 404.1.1 Fuel-gas-lighting-systems have - DComplies [F123]3 no continuous pilot light. - QDoes Not tizJ - ['Not Observable- QNot Applicable 1 High Impact(Tier 1) 2 Medium impact(Tier 2) 3 Low'moat."(Tier 3) Project Title:Saratoga Repot L date: 04114/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\126 Richmond Hills Drive.rck Page 8 of 9 Section Mans Verified Field Verified Final @n pectin ;•jr.;eeisl®n Value ValueComplies? ConaanentsfAssumptions Re'� 401.3 Compliance certificate posted. OComplies [FI7]z OPoes Not ONot Observable ONot Applicable 303.3 Manufacturer manuals for OComplies [FI18I3 mechanical and water heating DDoes Not systems have been provided. ['Not Observable ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: SardLoyd Report date: 014414/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\126 Richmond Hills Drive.rck Page 9 of 9 içLJ EfficNene,y R-valu* , Above-Grade Wall 21.00 Below-Grade Wall 2400 30M0 Floor Ceiling I Roof 4900 Ductwork(unconditioned spaces): Window 030 Door 0.19 , Heating&Cooling Equipment Efficiency ilk, -- Heating System: Cooling System: Water Heater: Name: Date: Comments