ResCheck W
' '129 Lir: Li)
c //' 11 or fia c Certificate .
M: Y ' 1 c
Project Saratoga - B ��gqTpy�o�,I�9W N OF(777:7 §�� �g
CO d iv... y LEv'tiCeup„
Energy Code: 2015 IECC �� ,�:�1.CitiEiT
Location: Glens Fails, New York
Construction Type: Single-family
Project Type: New Construction 308.7-1-64 RC-0265-2019
Conditioned Floor Area: 2,528 ft2 Hodorowski Homes
Glazing Area i0% 115 Richmond Hill Dr, Lot 17
Climate Zone: 6 (7635 HDD)
Permit Date: SFD w/gas FP 2527 s.f., Gar. 546 s.f.
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
115 Richmond Hills Drive Hodorowski Homes Northstar Home Design, LLC
Queensbury, NY
kWy O W E, 4 ,a.`--0- °; - . _ _ _ __ ._. , a ., , ,, _ ..�k., .. ...
Compliance: L1%Better Than Code Maximum UA: 360 Your UA: 356
The%Better or Worse Than Code Index reflects how dose to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to e minimum-code home.
E \a kPe Ass eLL1/ l 5
Gross Area Cavity Cont.
Assembly or U-Factor UA
Perimeter R-Value R-Value
Ceiling 1: Raised-or Energy Truss .1,595_ 49.0. 0.0 0.020 32
Wall 1:Wood Frame, 16"o.c. 3,220 21.0 0.0 0.057 163
Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 274 0.300 82
Door 1:Solid 51 0.190 10
Door 2:Glass 40 0.300 12
Basement Wall 1:Solid Concrete or Masonry 1,280 19.0 5.0 0.037 47
Wall height:8.0'
Depth below grade: 7.0'
Insulation depth:8.0'
Floor.2:All-Wood-joist/Truss:Oxier OutsideAir 48 30.0 0.0 0.033 2
Floor 3:Ail-Wood joist/Truss:Over Unconditioned Space 233 30.0 0.0 0.033 8
Compliance Statement:. The proposed building design described here is consistent with the building plans,specifications,and other
calculations submitted with the permit application.The proposed building has been('^.'- 'meet the 2015 IECC requirements in
REScheck Version 4.6.5 and to comply with the mandatory requirements listed section Checklist.
Name-Title Signature '' Date
• t1 '
b
fii rs VAS
4i) 2 * 40 .
. `:70 Report date: 04/38/39-
Project Title: Saratoga-B
Dadfilename: C:AUsers\jkazl\OneDriveEDocuments\REScheck\115 Richmont. i..0.'rive.rck Page 1 of 9
0
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the"Comments/Assumptions"column is provided by the user in the REScheck Requirements screen. For each
requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed.Where compliance is itemized in a separate table,a reference to that table is provided.
Section lams Verified Field Verified
Pre-1,respection/;'plad eview Value ValueComplies? Comments/Assumptions
Regan®
103.1, ;Construction drawings and 'OComplies
103.2 'documentation demonstrate ODoes Not
[PR1]' energy code compliance for the
building envelope.Thermal ONot Observable
envelope represented on IONot Applicable
construction documents.
103.1, ;Construction drawings and OCompiies
103.2, ;documentation demonstrate ODoes Not
403.7 energy code compliance for
[PR3]1 :lighting and mechanical systems. ,ONot Observable
Systems serving multiple ONot Applicable
dwelling units must demonstrate
'compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is; Heating: Heating: OComplies
403.7 sized per ACCA Manual S based Btu/hr Btu/hr 1ODoes-Not
[PR2]2 i on loads calculated per ACCA Cooling: Cooling:
Manual]or other methods ONot Observable
li
approved by the code official. Btu/hr Btu/hr ONot Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project-Title: Said1oga B Report date: 04/18/19
Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\115 Richmond Hills Drive.rck Page 2 of 9
Section flans Verified Field Verified
Foundation inspection Vague ague Complies? CommentsfAssumptions
402.1.1 `Conditioned basement wall ' R- R- ;DComp!ies 'See the Envelope Assemblies
[F04]1 insulation R-value.Where interior R_ R- QDoes Not table for values.
J insulation is used,verification
may need to occur during • QNot Observable
Insulation Inspection.Not. DNot Applicable
required in warns-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall QComplies
[F05]1 insulation installed per QDoes Not
manufacturer's instructions.
QNot Observable
QNot Applicable
402.2,9 •Conditioned basement wall ft • ft ;QComplies See the Envelope Assemblies
[F06]1 insulation depth of burial or QDoes Not table for values.
J :distance from top of wall. QNot Observable
•
i0Not Applicable
303.2.1 .A protective covering is installed QComplies
[F011]2 to protect exposed exterior QDoes Not
insulation and extends a
minimum of 6 in.below-grade. ['Not Observable
QNot Applicable
403.9 Snow-and ice-melting system ❑Complies
[F012]2 controls installed. 'QDoes Not •
['Not Observable
,ONot Applicable
Additional CommentsIAssumptiar st
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Tabs:Sanaiuga-B Report date: 04/18/19
Data filename: C:\Users\jkaz1\One®rive\Documents\REScheck\115 Richmond Hills Drive.rck Page 3 of 9
' Section ' T
Plans Verified Field Verifrie i I
# Framinti/Rough-En Inspection Vague Value Complies' / CO i14mients/Assaf' ptions
402.1.1, 'Door U-factor. U- ; U- ;[]Complies See the Envelope Assemblies
402.3.4 []Does Not "table for values.
[FR111
[]Not Observable
I]Not Applicable
402.1.1, 'Glazing U-factor(area-weighted U- ; U- ;[]Complies See the Envelope Assemblies
402.3.1, !average). []Does Not i table for values.
402.3.3,
402.5 ;DNot Observable
[FR211 ![]Not Applicable
303.1.3 li factors of fenestration products ElCompiies
[FR411 i are-determined in accordance 1 []Does Not
with the NFRC test procedure or
taken from the default table. []Not Observable
[]Not Applicable
402.4.1.1 ;Air barrier and thermal barrier []Complies
[FR2311 installed per manufacturer's Oboes Not
instructions. -
•;QNot Observable
[]Not Applicable
402.4.3 !Fenestration that is not site built ' []Complies
[FR2011 'is listed and labeled as meeting : - []Does Not
AANIAfifJDlviA/CSA 101/i,5.2/A440
or has infiltration rates per NFRC []Not Observable
400 that do not exceed code ElNot Applicable
:limits.
402.4.5 IC-rated recessed lighting fixtures []Complies
I[FR1612 sealed at housing/interior finish ' .[]Does Not
and labeled to indicate 5_2.0 cfm
feakaae at 75 Pa. []Not Observable
✓ ❑Not Applicable
403.3.1 ;Supply and return ducts in attics ;[]Complies
[FR1211 insulated>=R-B where duct is Oboes Not
'>=3 inches in diameter and>�.
R-b where<3 inches.Supply and []Not Observable
return ducts in other portions of []Not Applicable
the building insulated>=R-6 for
diameter>=3 inches and R-4.2
for<3 inches in diameter.
403.3.5 Building cavities are not used as QComplies
[FR15]3 ducts or plenums. '[]Does Not
v^
[]Not Observable
![]NotApplicable
403.4 'HVAC piping conveying fluids ; R- ; R- ;[]Complies
[FR1712 above 105-°F or chilled fluids []Does Not
below 55°F are insulated.to�R-
3. []Not Observable '
;[]Not Applicable
403.4.1 ;Protection of insulation on HVAC []Complies
[FR2411 piping. []Does Not
[]Not Observable
[]Not Applicable
403.5.3 :Hot water pipes are insulated to ; R- ' R- ;.[]Complies
[FR18]12 >_R-3. ;[]Does Not
_,, I f Not Observable
[]Not Applicable
403.6 Automatic or gravity dampers are []Complies
[FR1912 installed on all outdoor air jr1Does Not
intakes and exhausts.
[]Not Observable
;[]Nat Applicable
1 High Impact(Tier 1) 2 I Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title:Saratoga-B Report-date: 04/18/19
Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\115 Richmond Hills Drive.rck Page 4 of 9
Additional COREE iellt5/AsSEEITR 4 te0611So
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title:Sat dLo a-B Report-date: 04/18/19
Data filename: C:\Users\jkaz1\OneDrive\Documents\REScheckk115 Richmond Hills Drive.rck Page 5 of 9
SetaT r
llnsuletion hiSpectio Plans
Verified Field Verified lies? Continents/Assurnpti.ns
& Rego110 I I
303.1 'All installed insulation is labeled ❑Complies
[IN1312 or the installed R-values ❑Does Not
provided. [Not Observable
1 tiNot Applicable
402.1.1, .Floor insulation R-value. ; R- R- ;❑Complies ;See the Envelope Assemblies
402.2.6 ;0 Wood Q Wood '❑Does Not table for values.
[1N1I1
❑ Steel ❑ Steel ;DNot Observable
! ❑Not Applicable
I
303.2, ;Floor insulation installed per ❑Complies
402.2.7 manufacturer's instructions and ❑Does Not
[IN211 in substantial contact with the
underside of the subfloor,or floor ❑Not Observable
framing cavity insulation is in ❑Nat Applicable
contact with the top side of
sheathing,or continuous
i insulation is installed on the
underside of floor framing and
extends from the bottom to the
top of all perimeter floor framing
members.
402.1.1, :Wall insulation R-value.If this is a; R- ; R- ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the ❑ Wood Q Wood ;❑Does Not table for values.
402.2.6 :wall insulation on the wall 0 Mass ❑ Mass ;❑Not Observable
[IN3J1 exterior,the exterior insulation
requirement applies(FR10). Q Steel Steel ❑dot Applicable i
303.2 'Wall insulation is installed per .DComplies
[IN4)1 manufacturer's instructions. ❑Does Not
❑Not Observable
❑blot Applicable
Additional Comments/Assumptions
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Saratoga-B Report data: 04/18/19
Data filename: C:\Users\jkazl\OneDrive\Documents\Recheck\115 Richmond Hills Drive.rck Page 6 of 9
Section Plans Vernhed ( Field Verifie
Final laspect on Previsions Value Value Complies? Comments/Assumptions
Req.QD
402,1.1, :Ceiling insulation R-value. ; R- ; R- :E]Complies '.See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ODoes Not ;table for values.
402.2.2,
402.2 6 ❑ Steel O Steel ;ONot Observable
[Fll]1 ONot Applicable
303.1.1.1, Ceiling insulation installed per 'OComplies
303.2 manufacturer's instructions. ODoes Not
i[F12]1 ,Blown insulation marked every
300 ft2. E]Not Observable
ONot Applicable
1402.2.3 Vented attics with air permeable ' []Complies
[F12212 insulation include baffle adjacent ; ODoes Not
( to soffit and eave vents that ONot Observable
I extends over insulation.
,ONot Applicable
402.2,4 'Attic access hatch and door R- ; R- OComplies
[F13]1 insulation>_R-value of the ODoes Not
adjacent assembly..
;UNot Observable
ONot Applicable
402.4.1.2 ;Blower door test @ 50 Pa. <=5 ; ACH 50= ACH 50= []Complies
[F11711 ;ach in Climate Zones 1-2,and ❑Does Not
<=3 ach.in Climate Zones 3-8, ONot Observable
I
,ONot Applicable
403.3.4 ;Duct tightness test result of<=4 cfm/100 cfm/100 ;OComplies
[Fi4]1 ,ci'rri/100 ft2 across the system or ft2 ft2 ['Does Not
<=3 tint/100 ft2 without air
I handler @ 25 Pa. For rough-in ONot Observable
tests,verification may need to ONot Applicable
occur during Framing Inspection.
403.3.3 Ducts are pressure tested to cfm/100 cfm/100 OComplies
[F12711 determine air leakage with ft2 ft2 <ODoes Not
either: Rough-in test:Total
leakage measured with a ONot Observable
pressure differential of 0,1 inch ONot Appiicabie
w.g.across the system including
the manufacturer's air handler
enclosure if installed attime of
test.Postconstruction.test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g.across the entire system
including the manufacturer's air
handler enclosure_.
403.3.2.1 Air handler leakage designated 'OCompiies
[F124]/ i by manufacturer at<=2%of ODoes.Not
I design air flow.
,DNot Observable
ONot Applicable
403.1.1 Programmable thermostats OComplies
[Fi9]2 installed for control of primary ODoes Not
heating and cooling systems and ;
initially set by manufacturer to :ONot Observable
code specifications. ONot Applicable
403.1.2 'Heat pump thermostat installed :.00omplies
[FI10]2 on heat pumps. ;ODoes Not
:0Not Observable
ONot Applicable
403.5.1 Circulating service hot water • ;)]Compiles
[Fill]' systems have automatic or ODoes Not
accessible manual controls,
ONot Observable
ONot Applicable
1 High impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title:Saratoga-B Report dole. 04/18/19
Data filename: C:\Users\jkaz1\OneDrive\Documents\REScheck\115 Richmond Hills Drive.rck Page 7 of 9
Plans Verified Field Verified Complies? Comments/Assumptions
lie 1 Final inspection I�e�vi�iL.�� Value Value
403,6.1 All mechanical ventilation system QComplies
[F125]z fans not part of tested and listed QDoes Not
HVAC equipment meet efficacy QNot Observable
and air flow-limits.
ONot Applicable
403.2 Hot water boilers supplying heat DComplies
[F126)2 through one-or two-pipe heating QDoes Not
systems have outdoor setback [Not Observable
control to lower boiler water
temperature based on outdoor ONot Applicable
temperature.
403.5.1.1 Heated water circulation systems; ❑Complies
[FI2812 have a circulation pump.The QDoes Not
system return pipe is a dedicated ['Not Observable •.
return pipe or a cold water supply
pipe. Gravity and thermos- ONot Applicable
syphon circulation systems are
not present.Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand withinthe
occupancy.Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and.
no-demand-for hot water exists.
403.5.1.2 Electric heat trace systems 'QComplles-
l[FI2912 comply with IEEE 515.1 or UL QDoes Not
515.Controls automatically
ONot Observable
adjust the energy input to the [Not Applicable
heat-tracing to maintain the
desired water temperature in the
piping.
403.5.2 Water distribution systems that ❑Complies.
[F13012 have recirculation pumps that - ❑Does Not
pump water from a heated water ONot Observable
supply pipe back to the heated
water source through a cold QNot Applicable
water supply pipe have.a -
demand recirculation water
system.Pumps have controls - -
that manage operation of the
I pump and limit the temperature -
of the water entering the cold
water piping to 104°F.
f403.5.4 Drain water heat recovery units ❑Complies
E[FI3112 tested in accordance with CSA - QDoes Not
I B55.1..Potable water-side ONot Observable
pressure loss of drain water heat ONot Applicable
recovery.-units<3 psi for
individual units connected to one ! '
or two showers.Potable water-
side pressure loss of drain water
heat recovery units<2 psi for
individual units_connected to
three or more showers.
404.1 75%of lamps in permanent QComplies
[F16]1 fixtures or 75%of permanent ❑Does Not
;fixtures have high efficacy lamps. ['Not Observable
Does not apply to-low-voltage
lighting. ONot Applicable
404,1.1 Fuel-gas lighting systems have QCamplies
[F123)3 no continuous pilot light. QDoes Not
[Not Observable
QNot Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low lmpad.(Tier 3)
Project Title: Sardiuga -B Report date: 04/18/19"
Data filename: C:\llsers\jkazi\OneDrive\Documents\REScheck\115 Richmond Hills Drive.rck Page 8 of 9
::E:
Plans Veriifiedl F1eid Verified6�ina8 [a�siIeclLaon Pr®vial®ns @4a@rne �aC¢�� Cples?
401.3 Compliance certificate posted. DComplies
[F1772 ODoes Not
❑Not Observable
ONot Applicable
303.3 Manufacturer manuals for l]Complies
[FI1813 mechanical and water heating Oboes Not
'systems have been provided. ONot Observable
(E1Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Titie: Saratoga B Report dale: 04/18/19
Data filename: C:\Users\jkazl\OneDrivelDocuments\REScheck\115 Richmond Hills Drive.rck Page 9 of 9
JC ir(ry
L
filtaitdkR-414,4r5rx 4454 te,,..2-A'61,*
MA,t,.. 414.4
,,tzt A -142.,tgrer0.4Zegi.."eht.t%
Above-Grade Wall 21 MO.
Below-Grade Wall 24.00
Floor 30.00
Ceiling/Roof 49.00
Ductwork(unconditioned spaces):
jastg42)04, Ala ,,„ circ6,6',
oof
Window 0.30
Door 0.19
4.1110•A'1.14-erri;",,*-T' . 4
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments