ComCheck T COMcheck Software Version 4.1.1.0 Envelope Compliance Certificate Project Information FILE COPY Energy Code: 2015 IECC Project Title: West Glens Falls-WGFB-374 Location: Glens Falls, New York Climate Zone: 6a Project Type: New Construction -_-.. Vertical Glazing/Wall Area: 12% ��, N 3v, j�, a Construction Site: Owner/Agent: Desigher/Con(ractor 221 Corinth Road Stewart's Shops Corp. St vart s 5hR,f, Comic] ' c , Queensbury, NY 12804 ti % ". in.t its Additional Efficiency Package(s) `'!,_ .. :4,4 4 )Is1 ` "IReduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance catcto9s. g3 , Building Area Floor Area 8ff/'t` ,7. > ',� ` ,: 1-Retail : Nonresidential 4979 Envelope Assemblies Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factorial Perimeter Roof 1:Attic Roof with Wood Joists,[Bldg.Use 1 -Retail] 4979 49.0 0.0 0.021 0.021 Floor 1:Slab-On-Grade:Unheated,Vertical 4 ft.,[Bldg.Use 1 - 296 --- 10.0 0.480 0.540 Retail](c) NORTH Exterior Wall 1:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Retail] 1083 21.0 6.0 0.043 0.051 Window 1:Metal Frame with Thermal Break:Fixed,Perf.Specs.: 216 --- --- 0.360 0.360 Product ID na,SHGC 0.40,[Bldg.Use 1 -Retail](b) Door 2:Glass(>50%glazing):Metal Frame,Entrance Door, Perf. 57 --- --- 0.360 0.770 Specs.:Product ID na,SHGC 0.40,[Bldg.Use 1 -Retail](b) Door 3:Glass(>50%glazing):Metal Frame,Entrance Door,Perf. 57 --- --- 0.360 0.770 Specs.:Product ID na,SHGC 0.40,[Bldg. Use 1 -Retail](b) EAST Exterior Wall 3:Wood-Framed, 16"o.c.,[Bldg. Use 1 -Retail] 573 21.0 6.0 0.043 0.051 SOUTH Exterior Wall 2:Wood-Framed, 16"o.c.,[Bldg. Use 1 -Retail] 1083 21.0 6.0 0.043 0.051 Door 1:Insulated Metal,Swinging,[Bldg.Use 1 -Retail] 21 --- --- 0.370 0.370 Door 4:Insulated Metal,Swinging,[Bldg.Use 1 -Retail] 21 --- --- 0.370 0.370 WEST Exterior Wall 4:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Retail] 573 21.0 6.0 0.043 0.051 Window 2:Metal Frame with Thermal Break:Fixed,Perf.Specs.: 41 --- --- 0.360 0.360 Product ID na,SHGC 0.40,[Bldg.Use 1 -Retail](b) Window 3:Metal Frame with Thermal Break:Fixed,Perf.Specs.: 41 --- --- 0.360 0.360 Product ID na,SHGC 0.40,[Bldg.Use 1 -Retail](b) Project Title: West Glens Falls-WGFB-374 Report date: 05/13/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 1 of 18 Perm its\374 WEST GLENS FALLS-Building Permit\374-COMCHECK.cck f i = (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. (b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (c) Slab-On-Grade proposed and budget U-factors shown in table are F-factors. Envelope PASSES: Design 14% better than code Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application.The proposed envelope systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. �� ``�� 9 Name-Title Signature Date /��of NEN/r ./ �0W IN irixqlS co rn 2N - C� tad 09100 ee A°PESSIO1.0/ Project Title: West Glens Falls-WGFB-374 Report date: 05/13/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 2 of 18 Permits\374 WEST GLENS FALLS- Building Permit\374-COMCHECK.cck { COMcheck Software Version 4.1.1.0 11 Interior Lighting Compliance Certificate Project Information Energy Code: 2015 IECC FILE COPYJ Project Title: West Glens Falls-WGFB-374 Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: 221 Corinth Road Stewart's Shops Corp. Stewart's Shops Corp. Queensbury, NY 12804 Additional Efficiency Package(s) Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations. Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Retail 4979 1.13 5646 Total Allowed Watts= 5646 Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. 1-Retail LED 1:show room:LED Panel 40W: 2 62 39 2418 LED 2:4'strip/wrap:LED Other Fixture Unit 40W: 1 18 42 756 Total Proposed Watts= 3174 Interior Lighting PASSES: Design 44% better than code Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. fiCiL (.737;Y Name-Title Signature Date ,c pF NEW y `� i�� MAP �pW IN kT �'Q ey 5 kill_Ng" 73 IT ..,„tr? 0 lit W-1 �$ S. - asi`*�s15- . ., °91096 ' Ia 44, " s pr't • Project Title: West Glens Falls-WGFB-374 Report date: 05/13/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 3 of 18 Permits\374 WEST GLENS FALLS-Building Permit\374-COMCHECK.cck • 1 • ' COMcheck Software Version 4.1.1.0 \/(1 rflr Mechanical Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: West Glens Falls-WGFB-374 Location: Glens Falls, New York Climate Zone: 6a Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: 221 Corinth Road Stewart's Shops Corp. Stewart's Shops Corp. Queensbury, NY 12804 Additional Efficiency Package(s) Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations. Mechanical Systems List Quantity System Type&Description 1 HVAC System 1 (Single Zone): Heating:2 each-Central Furnace,Electric,Capacity=5 kBtu/h No minimum efficiency requirement applies Cooling:2 each-Single Package Vertical AC Unit,Capacity=5 kBtu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=65.00 EER,Required Efficiency: 9.00 EER Fan System: None 2 Water Heater 1: Electric Storage Water Heater,Capacity:40 gallons Proposed Efficiency:0.95 SL,%/h(if>12 kW),Required Efficiency:0.98 SL,%/h(if> 12 kW) 1 Water Heater 2: Electric Storage Water Heater,Capacity:4 gallons Proposed Efficiency:0.98 SL,%/h(if> 12 kW),Required Efficiency:7.05 SL,%/h(if>12 kW) Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in thet Inspection Checklist. �q C; Li - 1� 1 TGr1.J � r , c/'f/!/ Name-Title Signature Date / G�OFN�h� - 0 z 314 w ,h .gyp 'y,� z rl Ill 1-€."`‘ ,e. s'A4', u r.- ' n 0 !t04614,11 Xi M -as y f f-, v41)A 91p9 r . , 14 Ii, /40"*: t N „,L � Project Title: West Glens Falls-WGFB-374 Report date: 05/13/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 4 of 18 Permits\374 WEST GLENS FALLS-Building Permit\374-COMCHECK.cck COMcheck Software Version 4.1.1.0 Inspection Checklist Energy Code: 2015 IECC IPA Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions &Req.ID C103.2 Plans and/or specifications provide all ❑Complies 'Requirement will be met. [PR1]i information with which compliance ❑Does Not can be determined for the building envelope and document where Not Observable exceptions to the standard are ❑Not Applicable j claimed. C103.2 Plans, specifications,and/or ❑Complies Requirement will be met. [PR2]i calculations provide all information ❑Does Not with which compliance can be determined for the mechanical ['Not Observable systems and equipment and ENot Applicable document where exceptions to the 'standard are claimed. Load calculations per acceptable engineering standards and ;handbooks. C103.2 'Plans, specifications, and/or '❑Complies Requirement will be met. [PR3]1 calculations provide all information ❑Does Not with which compliance can be determined for the service water ['Not Observable heating systems and equipment and ❑Not Applicable document where exceptions to the 'standard are claimed. Hot water system sized per manufacturer's sizing guide. C103.2 Plans, specifications, and/or i❑Complies ;Requirement will be met. [PR4]i calculations provide all information ,❑Does Not ;with which compliance can be determined for the interior lighting ❑Not Observable and electrical systems and equipment ❑Not Applicable and document where exceptions to 'the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts,transformers and control devices. i C402.4.1 ;The vertical fenestration area <= 30 '❑Complies 'Requirement will be met. [PR10]1 percent of the gross above-grade wall ;❑Does Not area. ❑Not Observable ❑Not Applicable C402.4.1 The skylight area <= 3 percent of the ❑Complies Requirement will be met. [PR11]1 gross roof area. ❑Does Not ['Not Observable ❑Not Applicable C406 Plans, specifications,and/or ❑Complies Requirement will be met. [PR9]' calculations provide all information 1DDoes Not with which compliance can be determined for the additional energy Not Observable efficiency package options. Observable__, Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: West Glens Falls-WGFB-374 Report date: 05/13/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 5 of 18 Permits\374 WEST GLENS FALLS-Building Permit\374-COMCHECK.cck 1 ' ' Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: West Glens Falls-WGFB-374 Report date: 05/13/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 6 of 18 Permits\374 WEST GLENS FALLS- Building Permit\374-COMCHECK.cck Section Footing/Foundation Inspection Complies? Comments/Assumptions & Req,ID C303.2 Slab edge insulation installed per Complies Requirement will be met. [FO4]2 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable • C303.2.1 Exterior insulation protected against ❑Complies Requirement will be met. [FO6]1 damage, sunlight, moisture,wind, ❑Does Not landscaping and equipment maintenance activities. Not Observable j❑Not Applicable C402.2.5 Slab edge insulation R-value. ❑Complies See the Envelope Assemblies table for values. [FO3]2 ❑Does Not ❑Not Observable ❑Not Applicable C402.2.6 Radiant heating systems panels ❑Complies Exception: Requirement does not apply. [FO12]3 insulated to>=R-3.5 on face opposite ❑Does Not space being heated. See the Envelope Assemblies table for values. ['Not Observable ❑Not Applicable C403.2.4. Snow/ice melting system sensors for Complies Requirement will be met. 5, future connection to controls. Freeze EDoes Not C403.2.4. protection systems have automatic 6 controls installed. ❑Not Observable [FO9]3 ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: West Glens Falls-WGFB-374 Report date: 05/13/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 7 of 18 Permits\374 WEST GLENS FALLS-Building Permit\374-COMCHECK.cck Section Framing/Rough-In Inspection Complies? Comments/Assumptions & Req.ID C303.1.3 ;Fenestration products rated in ❑Complies ;Requirement will be met. [FR12]2 accordance with NFRC. ❑Does Not ❑Not Observable ❑Not Applicable C303.1.3 ;Fenestration products are certified as EComplies Requirement will be met. [FR13I1 :to performance labels or certificates ❑Does Not provided. ❑Not Observable ❑Not Applicable C402.4.3 Vertical fenestration SHGC value. ❑Complies ;See the Envelope Assemblies table for values. [FR10]1 ❑Does Not I❑Not Observable ❑Not Applicable C402.4.3, ;Vertical fenestration U-Factor. ;❑Complies See the Envelope Assemblies table for values. C402.4.3. ❑Does Not 4 [FR8]1 ;❑Not Observable ❑Not Applicable C402.4.4 ;U-factor of opaque doors associated ❑Complies See the Envelope Assemblies table for values. [FR14]2 with the building thermal envelope ;❑Does Not meets requirements. ❑Not Observable ❑Not Applicable C402.5.7 Vestibules are installed on all building ❑Complies Requirement will be met. [FR17]3 entrances. Doors have self-closing ❑Does Not devices. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: West Glens Falls-WGFB-374 Report date: 05/13/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 8 of 18 Permits\374 WEST GLENS FALLS-Building Permit\374-COMCHECK.cck Section Plumbing Rough-In Inspection Complies? Comments/Assumptions & Req.ID C404.5, 'Heated water supply piping conforms ❑Complies Exception: Requirement does not apply. C404.5.1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. [PL613 ['Not Observable ❑Not Applicable C404.5, Heated water supply piping conforms ❑Complies ;Requirement will be met. C404.5.1, to pipe length and volume ❑Does Not C404.5.2 =requirements. Refer to section details. [PL6]3 Not Observable ❑Not Applicable C404.5, ;Heated water supply piping conforms ❑Complies ;Requirement will be met. C404.5.1, 'to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. [PL6]3 ['Not Observable ❑Not Applicable C404.6.3 :Pumps that circulate water between a ❑Complies =Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to <= 5 minutes after end of heating Not Observable cycle. ❑Not Applicable C404.6.3 Pumps that circulate water between a ❑Complies Exception: Requirement does not apply. [PL713 heater and storage tank have controls ❑Does Not that limit operation from startup to <= 5 minutes after end of heating Not Observable cycle. .❑Not Applicable C404.6.3 Pumps that circulate water between a ❑Complies Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to • <= 5 minutes after end of heating Not Observable cycle. ❑Not Applicable C404.7 Water distribution system that pumps ❑Complies Exception: Requirement does not apply. [PL8]3 water from a heated-water supply ❑Does Not pipe back to the heated-water source through a cold-water supply pipe is a Not Observable demand recirculation water system. ❑Not Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. C404.7 Water distribution system that pumps ;❑Complies Exception: Requirement does not apply. [PL8]3 water from a heated-water supply I❑Does Not pipe back to the heated-water source through a cold-water supply pipe is a Not Observable demand recirculation water system. ❑Not Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: West Glens Falls-WGFB-374 Report date: 05/13/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 9 of 18 Permits\374 WEST GLENS FALLS-Building Permit\374-COMCHECK.cck Section # Plumbing Rough-In Inspection Complies? Comments/Assumptions & Req.ID C404.7 ;Water distribution system that pumps ❑Complies Exception: Requirement does not apply. [PL8]3 I water from a heated-water supply '❑Does Not pipe back to the heated-water source ;through a cold-water supply pipe is a ❑Not Observable demand recirculation water system. ;❑Not Applicable Pumps within this system have controls that start the pump upon 'receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to ;104°F. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: West Glens Falls-WGFB-374 Report date: 05/13/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 10 of 18 Permits\374 WEST GLENS FALLS-Building Permit\374-COMCHECK.cck • Section Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req ID C402.2.6 ;Thermally ineffective panel surfaces of ❑Complies 'Exception: Requirement does not apply. [ME41]3 ;sensible heating panels have ❑Does Not insulation >= R-3.5. ❑Not Observable ❑Not Applicable C402.5.5, Stair and elevator shaft vents have ❑Complies :Exception: Requirement does not apply. C403.2.4. motorized dampers that automatically ❑Does Not 3 ;close. [ME3]3 ❑Not Observable ❑Not Applicable C402.5.5, Outdoor air and exhaust systems have ❑Complies Exception: Gravity dampers acceptable for exhaust and relief C403.2.4. motorized dampers that automatically ❑Does Not dampers. 3 shut when not in use and meet [ME58]3 maximum leakage rates. Check ❑Not Observable gravity dampers where allowed. ❑Not Applicable C403.2.12 HVAC fan systems at design ❑Complies Exception: Requirement does not apply. .1 conditions do not exceed allowable ❑Does Not [ME65]3 fan system motor nameplate hp or fan ❑Not Observable See the Mechanical Systems list for values. system bhp. ❑Not Applicable C403.2.12 Fans have efficiency grade(FEG) >= ❑Complies Exception: Fans integral to equipment listed under Section .3 67.The total efficiency of the fan at ❑Does Not C403.2.3. [ME117]2 the design point of operation <= 15% of maximum total efficiency of the ENot Observable fan. ❑Not Applicable C403.2.13 Unenclosed spaces that are heated EComplies Exception: Requirement does not apply. [ME71]2 use only radiant heat. ❑Does Not ❑Not Observable ❑Not Applicable C403.2.3 HVAC equipment efficiency verified. ❑Complies 'See the Mechanical Systems list for values. [ME55]2 ❑Does Not ['Not Observable ❑Not Applicable C403.2.6. Demand control ventilation provided ❑Complies ;Requirement will be met. 1 for spaces>500 ft2 and >25 ❑Does Not [ME59]1 people/1000 ft2 occupant density and served by systems with air side Not Observable economizer, auto modulating outside ❑Not Applicable air damper control, or design airflow >3,000 cfm. C403.2.6. Enclosed parking garage ventilation ❑Complies Exception: Requirement does not apply. 2 has automatic contaminant detection ❑Does Not [ME115]3 and capacity to stage or modulate fans to 50%or less of design capacity. ❑Not Observable ❑Not Applicable C403.2.7 Exhaust air energy recovery on ❑Complies Exception: Requirement does not apply. [ME57]i systems meeting Table C403.2.7(1) ❑Does Not and C403.2.7(2). ❑Not Observable ❑Not Applicable C403.2.8 Kitchen exhaust systems comply with ❑Complies Exception: Requirement does not apply. [ME11613 replacement air and conditioned ❑Does Not supply air limitations, and satisfy hood rating requirements and maximum Not Observable exhaust rate criteria. ;❑Not Applicable C403,2.9 HVAC ducts and plenums insulated. ❑Complies Requirement will be met. [ME60]2 Where ducts or plenums are installed ❑Does Not in or under a slab,verification may need to occur during Foundation ['Not Observable Inspection. ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: West Glens Falls-WGFB-374 Report date: 05/13/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 11 of 18 Permits\374 WEST GLENS FALLS- Building Permit\374-COMCHECK.cck • Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req,ID C403.2.9 Ducts and plenums sealed based on ❑Complies Requirement will be met. [ME10]z static pressure and location. '❑Does Not DNot Observable Not Applicable C403.2.9. :Ductwork operating >3 in. water ;❑Complies Exception: Requirement does not apply. 1.3 'column requires air leakage testing. ❑Does Not [ME11]3 ❑Not Observable ❑Not Applicable C403.4.4. ;Multiple zone VAV systems with DDC '❑Complies ;Exception: Requirement does not apply. 6 of individual zone boxes have static ❑Does Not [ME110]3 pressure setpoint reset controls. See the Mechanical Systems list for values. ['Not Observable ❑Not Applicable C408.2.2. ;Air outlets and zone terminal devices '❑Complies Exception: Requirement does not apply. 1 :have means for air balancing. DDoes Not [ME53]3 Not Observable ❑Not Applicable C403.5, I Refrigerated display cases, walk-in 'DComplies Requirement will be met. C403.5.1, !coolers or walk-in freezers served by ;❑Does Not C403.5.2 ;remote compressors and remote [ME123]3 :condensers not located in a DNot Observable condensing unit, have fan-powered ❑Not Applicable condensers that comply with Sections C403.5.1 and refrigeration compressor' systems that comply with C403.5.2.. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: West Glens Falls-WGFB-374 Report date: 05/13/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 12 of 18 Permits\374 WEST GLENS FALLS-Building Permit\374-COMCHECK.cck Section Rough-In Electrical Inspection Complies? Comments/Assumptions & Req ID C405.2.1 Lighting controls installed to uniformly Complies Requirement will be met. [EL15]' reduce the lighting load by at least ❑Does Not 50%. ❑Not Observable ;❑Not Applicable C405.2.1 Occupancy sensors installed in ❑Complies Requirement will be met. [EL18]1 required spaces. ❑Does Not ❑Not Observable ❑Not Applicable C405.2.1, Independent lighting controls installed ❑Complies Requirement will be met. C405.2.2. per approved lighting plans and all ❑Does Not 3 manual controls readily accessible and • [EL23]2 visible to occupants. ENot Observable ❑Not Applicable C405.2.2. ;Automatic controls to shut off all ❑Complies Requirement will be met. 1 !building lighting installed in all ❑Does Not [EL22]2 buildings. ['Not Observable ❑Not Applicable C405.2.3 Daylight zones provided with ;❑Complies Requirement will be met. [EL16]2 I individual controls that control the ❑Does Not lights independent of general area ;lighting. ❑Not Observable ❑Not Applicable C405.2.3, Primary sidelighted areas are ❑Complies ;Exception: Requirement does not apply. C405.2.3. equipped with required lighting ❑Does Not 1, controls. C405.2.3. ['Not Observable 2 ❑Not Applicable [EL20]1 C405.2.3, Enclosed spaces with daylight area ❑Complies Exception: Requirement does not apply. C405.2.3. under skylights and rooftop monitors EDoes Not 1, are equipped with required lighting C405.2.3. controls. Not Observable 3 ❑Not Applicable [EL21]1 C405.2.4 Separate lighting control devices for EComplies Requirement will be met. [EL411 specific uses installed per approved ❑Does Not lighting plans. ['Not Observable ❑Not Applicable C405.2.4 Additional interior lighting power ❑Complies Requirement will be met. [EL8]1 allowed for special functions per the ❑Does Not approved lighting plans and is automatically controlled and [Not Observable separated from general lighting. ❑Not Applicable C405.3 Exit signs do not exceed 5 watts per ElComplies Requirement will be met. [EL6]'- face. ❑Does Not ['Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: West Glens Falls-WGFB-374 Report date: 05/13/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 13 of 18 Permits\374 WEST GLENS FALLS-Building Permit\374-COMCHECK.cck Section Insulation Inspection Complies? Comments/Assumptions & Req.ID C303.1 Roof insulation installed per ❑Complies Requirement will be met. [IN3]1 manufacturer's instructions. Blown or ❑Does Not poured loose-fill insulation is installed only where the roof slope is<=3 in Not Observable 12. ❑Not Applicable C303.1 'Building envelope insulation is labeled ❑Complies Requirement will be met. [IN10]2 with R-value or insulation certificate ❑Does Not providing R-value and other relevant data. :Not Observable ❑Not Applicable C303.2 Above-grade wall insulation installed ❑Complies Requirement will be met. [IN7]1 per manufacturer's instructions. ❑Does Not ['Not Observable ❑Not Applicable C303.2.1 Exterior insulation is protected from ❑Complies ;Requirement will be met. [IN14]2 damage with a protective material. ❑Does Not Verification for exposed foundation insulation may need to occur during ❑Not Observable Foundation Inspection. ❑Not Applicable C402.2.1 ;Insulation intended to meet the roof ❑Complies Requirement will be met. [IN17]3 insulation requirements cannot be ❑Does Not installed on top of a suspended ceiling. Mark this requirement Not Observable compliant if insulation is installed ❑Not Applicable accordingly. C402.2.3 Above-grade wall insulation R-value. ❑Complies See the Envelope Assemblies table for values. [IN6]1 ❑Does Not ❑Not Observable ❑Not Applicable C402.2.5 Floor insulation R-value. ❑Complies See the Envelope Assemblies table for values. [IN8]2 ❑Does Not ❑Not Observable ❑Not Applicable C402.2.6 ;Radiant panels and associated ❑Complies !Exception: Requirement does not apply. [IN18]3 components, designed for heat DDoes Not ;transfer from the panel surfaces to the occupants or indoor space are ['Not Observable insulated with a minimum of R-3.5. ❑Not Applicable C402.2.2 Roof R-value. For some ceiling ;❑Complies See the Envelope Assemblies table for values. [IN2]1 systems,verification may need to ;❑Does Not occur during Framing Inspection. ['Not Observable ❑Not Applicable C402.5.1. All sources of air leakage in the ❑Complies Requirement will be met. 1 building thermal envelope are sealed, Does Not [IN1]1 caulked,gasketed,weather stripped or wrapped with moisture vapor- ['Not Observable permeable wrapping material to ❑Not Applicable minimize air leakage. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: West Glens Falls-WGFB-374 Report date: 05/13/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 14 of 18 Permits\374 WEST GLENS FALLS-Building Permit\374-COMCHECK.cck Section Final Inspection Complies? Comments/Assumptions & Req.ID C303.3, Furnished O&M instructions for ❑Complies Requirement will be met. C408.2.5. systems and equipment to the ❑Does Not 2 building owner or designated [FI17]3 representative. ❑Not Observable ENot Applicable C303.3, Furnished O&M manuals for HVAC ❑Complies 'Requirement will be met. C408.2.5. :systems within 90 days of system ❑Does Not 3 ;acceptance. [F18]3 [Not Observable ❑Not Applicable C402.5 Building envelope contains a ;❑Complies Requirement will be met. [FI55]1 continuous air barrier that has been ❑Does Not tested and deemed to limit air leakage;❑Not Observable <= 0.40 cfm/ft2. ❑Not Applicable C402.5.6 Weatherseals installed on all loading ❑Complies Exception: Requirement does not apply. [FI37]1 dock cargo doors. ❑Does Not ❑Not Observable ❑Not Applicable C403.2.2 HVAC systems and equipment ❑Complies Requirement will be met. [FI27]3 capacity does not exceed calculated ❑Does Not loads. ❑Not Observable ❑Not Applicable C403.2.4. :Heating and cooling to each zone is ❑Complies Requirement will be met. 1 :controlled by a thermostat control. ❑Does Not [F147]3 !Minimum one humidity control device per installed Not Observable :humidification/dehumidification ❑Not Applicable system. C403.2.4. Thermostatic controls have a 5 °F ❑Complies Exception: Manual changeover thermostats. 1.2 deadband. ❑Does Not [FI38]3 ❑Not Observable ❑Not Applicable C403.2.4. (Temperature controls have setpoint '❑Complies Requirement will be met. 1.3 overlap restrictions. ❑Does Not [FI20]3 ❑Not Observable ❑Not Applicable C403.2.4. Each zone equipped with setback ❑Complies Requirement will be met. 2 controls using automatic time clock or ❑Does Not [F139]3 programmable control system. ❑Not Observable ❑Not Applicable C403.2.4. 'Automatic Controls: Setback to 55°F ❑Complies Requirement will be met. 2.1, (heat)and 85°F(cool); 7-day clock, 2- ❑Does Not C403.2.4. hour occupant override, 10-hour 2.2 backup Not Observable [F140]3 ❑Not Applicable C404.3 Heat traps installed on supply and ❑Complies Requirement will be met. [FI11]3 discharge piping of non-circulating ❑Does Not systems. ❑Not Observable ❑Not Applicable C404.3 Heat traps installed on supply and ❑Complies Requirement will be met. [FI11]3 discharge piping of non-circulating Oboes Not systems. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: West Glens Falls-WGFB-374 Report date: 05/13/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 15 of 18 Permits\374 WEST GLENS FALLS-Building Permit\374-COMCHECK.cck Section Final Inspection Complies? Comments/Assumptions & Req.ID C404.4 ;All piping insulated in accordance with ❑Complies Requirement will be met. [F125]2 I section details and Table C403.2.10. ❑Does Not :Not Observable DNot Applicable C404.4 ;All piping insulated in accordance with ;❑Complies Requirement will be met. [F125]2 ;section details and Table C403.2.10. ;❑Does Not ENot Observable DNot Applicable C405.4.1 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values. [FI18]1 lighting power is consistent with what ❑Does Not is shown on the approved lighting plans, demonstrating proposed watts ❑Not Observable, are less than or equal to allowed ;DNot Applicable watts. C408.2.1 Commissioning plan developed by ❑Complies Requirement will be met. [F128]1 registered design professional or ❑Does Not approved agency. ;DNot Observable ;❑Not Applicable C408.2.3. HVAC equipment has been tested to ❑Complies Requirement will be met. 1 ensure proper operation. ❑Does Not [F131]1 ❑Not Observable ❑Not Applicable C408.2.3. HVAC control systems have been ❑Complies Requirement will be met. 2 tested to ensure proper operation, ❑Does Not [F110]1 calibration and adjustment of controls. ❑Not Observable ❑Not Applicable C408.2.4 Preliminary commissioning report ❑Complies Requirement will be met. [FI29]1 completed and certified by registered ❑Does Not design professional or approved agency. [Not Observable ❑Not Applicable C408.2.5. ;Furnished HVAC as-built drawings ❑Complies Requirement will be met. 1 'submitted within 90 days of system ❑Does Not [F17]3 acceptance. ['Not Observable ❑Not Applicable ; C408.2.5. Furnished as-built drawings for ❑Complies Requirement will be met. 1 electric power systems within 90 days Does Not [F116]3 of system acceptance. DNot Observable DNot Applicable C408.2.5. An air and/or hydronic system ❑Complies Requirement will be met. 3 balancing report is provided for HVAC ❑Does Not [FI43]1 systems. DNot Observable DNot Applicable C408.2.5. Final commissioning report due to ❑Complies Requirement will be met. 4 building owner within 90 days of ❑Does Not [F130]1 receipt of certificate of occupancy. ❑Not Observable ❑Not Applicable C408.3 Lighting systems have been tested to ❑Complies Requirement will be met. [F133]1 ensure proper calibration, adjustment, ❑Does Not programming, and operation. DNot Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: West Glens Falls-WGFB-374 Report date: 05/13/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 16 of 18 Permits\374 WEST GLENS FALLS-Building Permit\374-COMCHECK.cck 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: West Glens Falls-WGFB-374 Report date: 05/13/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 17 of 18 Permits\374 WEST GLENS FALLS-Building Permit\374-COMCHECK.cck COMcheck Software Version 4.1.1.0 ' %,. Interior Lighting Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: Glens Falls National Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 221 Corinth Rd Stewart's Shops Corp. Queensbury, NY 12804 Ballston Spa, NY 12020 Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Office 1283 0.82 1052 Total Allowed Watts= 1052 Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp I Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Office(1283 sq.ft.) LED 1:2 x 2 Bank:LED Panel 40W: 1 19 40 760 LED 5:LED can light:LED Undercabinet Unit 12W: 1 5 12 60 Total Proposed Watts= 820 Interior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Ch st. 1/1-5 B Name-Title Signature Date nzft 'en ' * ® I 4 b4 +• �. * (%; ", ;, kl r ( 1 1, r �j dw % t• 40 £ tYz 1- ,1 190FESSIO4 Project Title: Glens Falls National Report date: 05/14/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 1 of 11 Permits\374 WEST GLENS FALLS-Building Permit\374-Bank fit-up.cck 11116- COMcheck Software Version 4.1.1.0 Mechanical Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: Glens Falls National Location: Glens Falls, New York Climate Zone: 6a Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 221 Corinth Rd Stewart's Shops Corp. Queensbury, NY 12804 Ballston Spa, NY 12020 Mechanical Systems List Quantity System Type&Description 1 HVAC System 3(Single Zone): Heating: 1 each-Duct Furnace,Propane,Capacity=130 kBtu/h Proposed Efficiency=95.50%Ec,Required Efficiency: 80.00%Ec Cooling: 1 each-Single Package Vertical AC Unit,Capacity=36 kBtu/h,Air-Cooled Condenser,No Economizer,Economizer exception:Heat Recovery System Proposed Efficiency=14.00 EER,Required Efficiency: 9.00 EER Fan System: None 1 Water Heater 1: Electric Instantaneous Water Heater,Capacity:4 gallons Proposed Efficiency:7.05 SL,%/h(if> 12 kW), Required Efficiency:7.05 SL,%/h(if>12 kW) Mechanical Compliance Statement Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable manda ory requirements listed in the Inspection Checklist. Seri- r . IL 1-ri..i,► / - = ' /r /� Name-Title Signature Date ' 4,0F NEW y tpI. ��.1 R�ESSION� o,..7)) = s e b 0 9:,:i .. ' / y�} P Project Title: Glens Falls National Report date: 05/14/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 2 of 11 Permits\374 WEST GLENS FALLS-Building Permit\374-Bank fit-up.cck COMcheck Software Version 4.1.1.0 Inspection Checklist Energy Code: 2015 IECC irdt Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans, specifications, and/or ❑Complies ;Requirement will be met. [PR2]1 .calculations provide all information ❑Does Not with which compliance can be determined for the mechanical ['Not Observable I systems and equipment and ❑Not Applicable document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and ;handbooks. C103.2 ;Plans, specifications, and/or ❑Complies Requirement will be met. [PR3]1 .calculations provide all information ❑Does Not with which compliance can be I determined for the service water ❑Not Observable heating systems and equipment and ❑Not Applicable ; document where exceptions to the standard are claimed. Hot water system sized per manufacturer's sizing guide. C103.2 Plans, specifications, and/or ❑Complies !Requirement will be met. [PR4]1 calculations provide all information ❑Does Not with which compliance can be determined for the interior lighting ❑Not Observable and electrical systems and equipment I❑Not Applicable and document where exceptions to ;the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts,transformers and control devices. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Glens Falls National Report date: 05/14/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 3 of 11 Permits\374 WEST GLENS FALLS-Building Permit\374-Bank fit-up.cck Section # Footing/Foundation Inspection Complies? Comments/Assumptions & Req.ID C403.2.4. Snow/ice melting system sensors for ❑Complies Requirement will be met. 5, ;future connection to controls. Freeze ❑Does Not C403.2.4. protection systems have automatic 6 controls installed. Not Observable [FO913 ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Glens Falls National Report date: 05/14/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 4 of 11 Permits\374 WEST GLENS FALLS- Building Permit\374-Bank fit-up.cck Section # Plumbing Rough-In Inspection Complies? Comments/Assumptions & Req.ID C404.5, Heated water supply piping conforms ❑Complies Requirement will be met. C404.5.1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. [PL613 ❑Not Observable, ❑Not Applicable C404.5, Heated water supply piping conforms EComplies Requirement will be met. C404.5.1, to pipe length and volume '❑Does Not C404.5.2 requirements. Refer to section details. [PL6]3 ❑Not Observable ❑Not Applicable C404.6.3 Pumps that circulate water between a ❑Complies Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to <= 5 minutes after end of heating ['Not Observable I cycle. ElNot Applicable C404.6.3 Pumps that circulate water between a ❑Complies Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to <= 5 minutes after end of heating [Not Observable cycle. ❑Not Applicable C404.7 'Water distribution system that pumps ❑Complies Exception: Requirement does not apply. [PL8]3 water from a heated-water supply ❑Does Not pipe back to the heated-water source through a cold-water supply pipe is a ❑Not Observable demand recirculation water system. ❑Not Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. C404.7 Water distribution system that pumps `❑Complies Exception: Requirement does not apply. [PL8]3 water from a heated-water supply ❑Does Not pipe back to the heated-water source through a cold-water supply pipe is a ,❑Not Observable demand recirculation water system. ❑Not Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Glens Falls National Report date: 05/14/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 5 of 11 Permits\374 WEST GLENS FALLS-Building Permit\374-Bank fit-up.cck Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C402.2.6 Thermally ineffective panel surfaces of DComplies Exception: Requirement does not apply. [ME41]3 sensible heating panels have ❑Does Not insulation >= R-3.5. ❑Not Observable ❑Not Applicable C403.2.12 HVAC fan systems at design DComplies Requirement will be met. .1 conditions do not exceed allowable ❑Does Not [ME65]3 fan system motor nameplate hp or fan ❑Not Observable See the Mechanical Systems list for values. system bhp. ❑Not Applicable C403.2.12;Fans have efficiency grade(FEG) >= DComplies Exception: Fans included in equipment having certified seal .3 ;67.The total efficiency of the fan at DDoes Not for air or energy performance of the equipment package. [ME117]2 ;the design point of operation <= 15% of maximum total efficiency of the ['Not Observable Ifan. ;❑Not Applicable C403.2.13 Unenclosed spaces that are heated DComplies Exception: Requirement does not apply. [ME71]2 use only radiant heat. ❑Does Not ❑Not Observable ❑Not Applicable C403.2.3 ;HVAC equipment efficiency verified. DComplies 'See the Mechanical Systems list for values. [ME55]2 I DDoes Not ;❑Not Observable DNot Applicable C403.2.6. Demand control ventilation provided DComplies Exception: Systems with energy recovery. 1 for spaces>500 ft2 and >25 DDoes Not [ME59]1 people/1000 ft2 occupant density and served by systems with air side ['Not Observable economizer, auto modulating outside ❑Not Applicable air damper control, or design airflow >3,000 cfm. C403,2.6. ;Enclosed parking garage ventilation ❑Complies Exception: Requirement does not apply. 2 ;has automatic contaminant detection ❑Does Not [ME115]3 and capacity to stage or modulate ;fans to 50%or less of design capacity. Not Observable ❑Not Applicable C403.2.7 Exhaust air energy recovery on DComplies Requirement will be met. [ME57]1 systems meeting Table C403.2.7(1) DDoes Not and C403.2.7(2). ENot Observable ❑Not Applicable C403.2.8 Kitchen exhaust systems comply with DComplies Exception: Requirement does not apply. [ME116]3 replacement air and conditioned DDoes Not supply air limitations, and satisfy hood rating requirements and maximum ['Not Observable exhaust rate criteria. ❑Not Applicable C403.2.9 ;HVAC ducts and plenums insulated. ;DComplies Requirement will be met. [ME60j2 'Where ducts or plenums are installed !DDoes Not in or under a slab,verification may ;need to occur during Foundation ❑Not Observable Inspection. DNot Applicable C403,2.9 Ducts and plenums sealed based on DComplies Requirement will be met. [ME10]z static pressure and location. DDoes Not ❑Not Observable ❑Not Applicable . C403.2.9. Ductwork operating >3 in.water DComplies Requirement will be met. 1.3 column requires air leakage testing. DDoes Not [ME11]3 [Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Glens Falls National Report date: 05/14/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 6 of 11 Permits\374 WEST GLENS FALLS-Building Permit\374-Bank fit-up.cck Section Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C403.4.4. Multiple zone VAV systems with DDC ❑Complies ;Exception: Requirement does not apply. 6 lof individual zone boxes have static ❑Does Not [ME110]3 pressure setpoint reset controls. See the Mechanical Systems list for values. ❑Not Observable; ❑Not Applicable C408.2.2. Air outlets and zone terminal devices ❑Complies ;Exception: Fans with fan motors of 1 hp (0.74 kW)or less. 1 have means for air balancing. ❑Does Not [ME53]3 ❑Not Observable! ❑Not Applicable C403.5, Refrigerated display cases, walk-in ❑Complies ;Exception: Requirement does not apply. C403.5.1, !coolers or walk-in freezers served by ❑Does Not C403.5.2 remote compressors and remote [ME123]3 condensers not located in a ENot Observable condensing unit, have fan-powered 1,—Not Applicable condensers that comply with Sections ;C403.5.1 and refrigeration compressor systems that comply with C403.5.2.. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Glens Falls National Report date: 05/14/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 7 of 11 Permits\374 WEST GLENS FALLS- Building Permit\374-Bank fit-up.cck Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.1 Lighting controls installed to uniformly ❑Complies Requirement will be met. [EL15]1 reduce the lighting load by at least ❑Does Not 50%. DNot Observable; ❑Not Applicable C405.2.1 Occupancy sensors installed in ❑Complies !Requirement will be met. [EL18]1 required spaces. ❑Does Not [Not Observable ❑Not Applicable C405.2.1, Independent lighting controls installed ❑Complies Requirement will be met. C405.2.2. per approved lighting plans and all ❑Does Not 3 manual controls readily accessible and [EL23]2 visible to occupants. ❑Not Observable ENot Applicable C405.2.2. Automatic controls to shut off all DComplies Requirement will be met. 1 building lighting installed in all ❑Does Not [EL22]2 buildings. DNot Observable ❑Not Applicable C405.2.3 Daylight zones provided with ❑Complies Exception: Requirement does not apply. [EL16]2 :individual controls that control the ❑Does Not lights independent of general area ;lighting. ❑Not Observable ❑Not Applicable C405.2.3, Primary sidelighted areas are ❑Complies Exception: Requirement does not apply. C405.2.3. equipped with required lighting ❑Does Not 1, controls. C405.2.3. DNot Observable 2 ❑Not Applicable [EL20]1 C405.2.3, Enclosed spaces with daylight area ❑Complies :Exception: Requirement does not apply. C405.2.3. under skylights and rooftop monitors ❑Does Not 1, are equipped with required lighting C405.2.3. controls. ❑Not Observable 3 ❑Not Applicable [EL21]1 C405.2.4 Separate lighting control devices for ❑Complies 'Requirement will be met. [EL4]1 specific uses installed per approved ❑Does Not lighting plans. DNot Observable DNot Applicable C405.2.4 Additional interior lighting power ❑Complies Requirement will be met. [EL8]1 allowed for special functions per the ❑Does Not approved lighting plans and is automatically controlled and DNot Observable separated from general lighting. DNot Applicable C405.3 'Exit signs do not exceed 5 watts per ;❑Complies Requirement will be met. [EL6]1 face. !❑Does Not ['Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Glens Falls National Report date: 05/14/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 8 of 11 Permits\374 WEST GLENS FALLS-Building Permit\374-Bank fit-up.cck Section Final Inspection Complies? Comments/Assumptions & Req.ID C303.3, Furnished O&M instructions for Complies Requirement will be met. C408.2.5. systems and equipment to the EDoes Not 2 building owner or designated [FI17]3 representative. ['Not Observable ENot Applicable C303.3, Furnished O&M manuals for HVAC ;EComplies Requirement will be met. C408.2.5. systems within 90 days of system :EDoes Not 3 acceptance. [F18]3 '❑Not Observable ❑Not Applicable C403.2.2 HVAC systems and equipment EComplies Requirement will be met. [FI27]3 capacity does not exceed calculated EDoes Not loads. ['Not Observable ❑Not Applicable C403.2.4. Heating and cooling to each zone is EComplies Requirement will be met. 1 controlled by a thermostat control. EDoes Not [F147]3 Minimum one humidity control device per installed ['Not Observable humidification/dehumidification ENot Applicable system. C403.2.4. Thermostatic controls have a 5 °F ❑Complies Requirement will be met. 1.2 deadband. EDoes Not [FI38]3 ['Not Observable ❑Not Applicable C403.2.4. Temperature controls have setpoint EComplies Requirement will be met. 1.3 overlap restrictions. EDoes Not [F120]3 ENot Observable ENot Applicable C403.2.4. Each zone equipped with setback ;EComplies Exception: Requirement does not apply. 2 controls using automatic time clock or i❑Does Not [F139]3 programmable control system. ENot Observable; ❑Not Applicable C403.2.4. Automatic Controls: Setback to 55°F EComplies Requirement will be met. 2.1, (heat) and 85°F(cool); 7-day clock, 2- EDoes Not C403.2.4. hour occupant override, 10-hour 2.2 backup Not Observable [F140]3 ENot Applicable C404.3 Heat traps installed on supply and EComplies Requirement will be met. [F111]3 discharge piping of non-circulating ElDoes Not systems. ENot Observable ENot Applicable C404.4 All piping insulated in accordance with EComplies Requirement will be met. [F125]2 section details and Table C403.2.10. EDoes Not ['Not Observable ENot Applicable C405.4.1 Interior installed lamp and fixture EComplies See the Interior Lighting fixture schedule for values. [F118)1 lighting power is consistent with what EDoes Not is shown on the approved lighting plans, demonstrating proposed watts [(Not Observable are less than or equal to allowed Observable,_._, Applicable watts. C408.2.1 Commissioning plan developed by EComplies Requirement will be met. [F128)1 registered design professional or EDoes Not approved agency. ENot Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Glens Falls National Report date: 05/14/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 9 of 11 Permits\374 WEST GLENS FALLS-Building Permit\374-Bank fit-up.cck Section Final Inspection Complies? Comments/Assumptions & Req.ID C408.2.3. 'HVAC equipment has been tested to Complies Requirement will be met. 1 !ensure proper operation. ❑Does Not [FI31]1 [Not Observable ❑Not Applicable C408.2.3. HVAC control systems have been ❑Complies Requirement will be met. 2 tested to ensure proper operation, ❑Does Not [FI10]1 calibration and adjustment of controls. ['Not Observable ❑Not Applicable C408.2.4 Preliminary commissioning report Complies Requirement will be met. [FI29]1 completed and certified by registered ❑Does Not design professional or approved agency. ❑Not Observable ❑Not Applicable C408.2.5. Furnished HVAC as-built drawings ❑Complies Requirement will be met. 1 submitted within 90 days of system ❑Does Not [F17]3 acceptance. ❑Not Observable ❑Not Applicable C408.2.5. Furnished as-built drawings for ❑Complies Requirement will be met. 1 electric power systems within 90 days ❑Does Not [FI16]3 of system acceptance. ❑Not Observable ❑Not Applicable C408.2.5. An air and/or hydronic system °❑Complies Requirement will be met. 3 balancing report is provided for HVAC ❑Does Not [FI43]1 systems. ❑Not Observable ❑Not Applicable C408.2.5. Final commissioning report due to ❑Complies Requirement will be met. 4 building owner within 90 days of ❑Does Not [F130]1 receipt of certificate of occupancy. ❑Not Observable DNot Applicable C408.3 Lighting systems have been tested to ❑Complies Requirement will be met. [F133]1 ensure proper calibration, adjustment, ❑Does Not programming, and operation. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Glens Falls National Report date: 05/14/19 Data filename: G:\Facility\Shop Construction\374 WEST GLENS FALLS\374 WEST GLENS FALLS-Applications ar Page 10 of 11 Permits\374 WEST GLENS FALLS-Building Permit\374-Bank fit-up.cck