Loading...
blower doorTesting Company: Name:LoCascio Energy Solutions Address:20 Ogden Rd. Queensbury , NEW YORK 12804 Phone: 5188573144 Technician: Name:Anthony LoCascio Credentials:HERS Rater#4242961 Email:tony@locascioenergysolutions.com Building Information: Project ID:68 John Address:68 John Clendon Rd. Queensbury, NY 12804 Geo-Tag Data:Latitude: 43.341352 Longitude: -73.707928 Timestamp: 2019-12-26 16:06:54 Customer Information: Name:Foothills Builders Address:Queensbury, NY 12804 Measured Leakage:1,213.9 CFM50 Test ID:68 John Purpose of Test:RESNET Multi-Pt Env. Leakage Measured ACH50:2.80 (+/- 3.0%)Effective Leakage Area: 63.7 in² Building Volume:26,058.0 ft³Enclosure Surface Area: 3,280.0 ft² Flow Coefficient (C):88.8 (+/- 11.2%)Exponent (n): 0.668 (+/- 0.033) Correlation Coefficient:0.99965 Test Standard:RESNET 380 Multi-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 65 °F Altitude: 456.0 ft Outdoor Temp: 35 °F Time Average Period: 10 seconds Test Date and Time:2019-12-26 16:28:21 Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -1.3 -60.0 -61.7 -60.4 -63.2 1,435.6 Ring A -48.0 -49.2 -47.9 -46.7 1,238.7 Ring A -35.0 -35.9 -34.6 -31.1 1,015.3 Ring A -23.0 -23.1 -21.8 -159.4 748.5 Ring B -10.0 -9.6 -8.3 -41.0 381.9 Ring B Test Equipment: Flow Device:Model 3 110V Fan Serial #: 3172 Pressure Gauge:DG1000 Serial #: 3172 Calibration Date: 2019-02-18 Deviations from Standard: None Comments: Envelope Leakage Test (Page 2) Report generated by TEC Auto Test version 1.6.3 (2), © 2019 by The Energy Conservatory, Inc.