Loading...
ResCheck , , REScheck Software Version 4.6.4 1 t Compliance Certificate eq a ,.-i 0 u Project 28X42 RANCH (1176) DECEOWIE5 of CNI Energy Code: 2015 IECC t\ +� bA Location: Glens Falls, New York 0 rt MAY 172019 a Construction Type: Single-family t rn +r C_� Project Type: New Construction Conditioned Floor Area: 0 ft2 TOWN OF QUEENSBURY . -, ‘a: Glazing Area 13% BUILDING&CODES .°„) o i Climate Zone: 6 (7635 HDD) 1 :' L\ Permit Date: o�lp y E r�-I Permit Number: G H Q cnV � t Construction Site: Owner/Agent: Designer/Contractor: 12 TIMMONS COURT CLUTE ENTERPRISES, INC — QUEENSBURY, NY 12804, NY 12804 6 HOLDEN AVE REVIEWED FOR QUEENSBURY, NY 12804 +t C tr 518-793-7277 CLUTEENTERPRISES@GMAIL.COM ENERGY CODE COMPLIANCE Compliance: Passes using UA trade-off Compliance: 3.4%Better Than Code Maximum UA: 179 Your UA: 173 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter Ceiling 1: Raised or Energy Truss 1,176 38.0 0.0 0.025 29 Wall 1:Wood Frame, 16"o.c. 1,088 19.0 0.0 0.060 55 Window 1:Vinyl Frame:Double Pane with Low-E 98 0.330 32 Door 1: Solid 38 0.160 6 Door 2: Glass 40 0.310 12 Basement Wall 1: Solid Concrete or Masonry 1,012 0.0 19.0 0.039 39 Wall height: 8.0' — — Depth below grade: 7.0' ,,,,, Insulation depth: 8.0' Compliance Statement: The proposed building design described here.s co isf;efit with t building plans, specifications, and other calculations submitted with the permit application.The proposed bui(din as. de f ed to meet the 2015 IECC requirements in REScheck Version 4.6.4 and to comply with the mandatory requirem in e check Inspection Checklist. Name-Title - / Sig ure Date Project Title: 28X42 RANCH (1176) Report date: 05/13/19 Data filename: Z:\Clutel\Rescheck\2019 - 12 TIMMONS COURT QSBY- 28X42 RANCH (1176).rck Page 1 of 9 t it REScheck Software Version 4.6.4 Ins pection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req,ID_ 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. [Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR212 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Manual J or other methods Btu/hr Btu/hr ❑Not Applicable approved by the code official. pp i Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 28X42 RANCH (1176) Report date: 05/13/19 Data filename: Z:\Clutel\Rescheck\2019- 12 TIMMONS COURT QSBY- 28X42 RANCH (1176).rck Page 2 of 9 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1 Conditioned basement wall R- R- EComplies See the Envelope Assemblies [F04]1 insulation R-value.Where interior R_ R- ElDoes Not table for values. insulation is used,verification may need to occur during ❑Not Observable Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [F05]1 insulation installed per ❑Does Not manufacturer's instructions. ENot Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies iSee the Envelope Assemblies [F06]1 insulation depth of burial or ❑Does Not table for values. distance from top of wall. ENot Observable ❑Not Applicable 303.2.1 ;A protective covering is installed ❑Complies [FOil]2 to protect exposed exterior ❑Does Not insulation and extends a minimum of 6 in. below grade. ;❑Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [F012]2 controls installed. ❑Does Not [Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 28X42 RANCH (1176) Report date: 05/13/19 Data filename: Z:\Clutel\Rescheck\2019 - 12 TIMMONS COURT QSBY- 28X42 RANCH (1176).rck Page 3 of 9 [ Section Framing/Rough-In Inspection Plans Verified Field Verified 9 p Value Value Complies? Comments/Assumptions & Req.l® 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 pilot Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- DComplies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.6,402.3.6, ❑Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products ❑Comp►ies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. ❑Not Observable ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]i installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR2O]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/1.5.2/A440 or has infiltration rates per NFRC ['Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures` ?❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate<2.0 cfm leakage at 75 Pa. ['Not Observable ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >= R-6 where < 3 inches. Supply and` ❑Not Observable return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as '❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids ! R- R- ❑Complies [FR17]2 above 105°F or chilled fluids ❑Does Not below 55°F are insulated to 3 ❑Not Observable ❑Not Applicable 403.4.1 ,Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 28X42 RANCH (1176) Report date: 05/13/19 Data filename: Z:\Clutel\Rescheck\2019 - 12 TIMMONS COURT QSBY- 28X42 RANCH (1176).rck Page 4 of 9 Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 28X42 RANCH (1176) Report date: 05/13/19 Data filename: Z:\Clutel\Rescheck\2019- 12 TIMMONS COURT QSBY- 28X42 RANCH (1176).rck Page 5 of 9 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions St Rer1.ID ,303.1 All installed insulation is labeled ❑Complies [IN13]z or the installed R-values ❑Does Not provided. ❑Not Observable ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies ;See the Envelope Assemblies 402.2.5, mass wall with at least 1A of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall [IN3]1 exterior,the exterior insulation Mass ❑ Mass ❑Not Observable requirement applies(FR10). ❑ Steel El Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4]1 'manufacturer's instructions. ElDoes Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 28X42 RANCH (1176) Report date: 05/13/19 Data filename: Z:\Clutel\Rescheck\2019 - 12 TIMMONS COURT QSBY- 28X42 RANCH (1176).rck Page 6 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.JD 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel ENot Observable 402.2.E ❑Not Applicable [FI1] pp 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [F1211 Blown insulation marked every 300 ft2. Not Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ' ❑Complies [FI22]2 insulation include baffle adjacent EDoes Not to soffit and eave vents that extends over insulation. ENot Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [F13]1 insulation >.R-value of the -❑Does Not adjacent assembly. ENot Observable ENot Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies [F117]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [F14]1 cfm/100 ft2 across the system or ! ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ❑Not Observable ; tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [F127]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ['Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 ;Air handler leakage designated EComplies [F124]1 by manufacturer at <=2%of ❑Does Not design air flow. ❑Not Observable ENot Applicable 403.1.1 Programmable thermostats ❑Complies fF19]2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. LJNot Applicable 403.1.2 Heat pump thermostat installed ;❑Complies [FI10]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water i❑Complies [F1ll]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 28X42 RANCH (1176) Report date: 05/13/19 Data filename: Z:\Clutel\Rescheck\2019 - 12 TIMMONS COURT QSBY- 28X42 RANCH (1176).rck Page 7 of 9 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions &Reg,ID III 403.6.1 All mechanical ventilation system ❑Complies [FI25]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. Not Observable ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [F126]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water [Not Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [F12812 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply Not Observable pipe.Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems DComplies [FI29]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically adjust the energy input to the Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F130]2 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated ❑Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104°F. 403.5.4 Drain water heat recovery units ❑Complies [F13112 tested in accordance with CSA Oboes Not B55.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units< 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [FI6]1 fixtures or 75%of permanent ['Does Not fixtures have high efficacy lamps. Does not apply to low-voltage Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [FI23]3 no continuous pilot light. ❑Does Not ENot Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 28X42 RANCH (1176) Report date: 05/13/19 Data filename: Z:\Clutel\Rescheck\2019 - 12 TIMMONS COURT QSBY- 28X42 RANCH (1176).rck Page 8 of 9 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions &Req.ID 401.3 Compliance certificate posted. EComplies [F17]2 ❑Does Not [Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [F118]3 mechanical and water heating 1 ❑Does Not systems have been provided. ['Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 28X42 RANCH (1176) Report date: 05/13/19 Data filename: Z:\Clutel\Rescheck\2019 - 12 TIMMONS COURT QSBY- 28X42 RANCH (1176).rck Page 9 of 9 A c2015 IECC Energy ...1( Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 19.00 Below-Grade Wall 19.00 Floor 0.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.33 Door 0.31 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments