Loading...
FM Inspections s .< f fi Town of Queensbury- Building and Codes- Fire Marshal 742 Bay Road-(518)761-8256 Building (518)761-8206 Fire Marshal Case Number: CC-0539-2018 Case Module: Permit Inspection Date: Fri Sep 20, 2019 Inspection Status: Passed Inspector: Mike Palmer Inspection Type: OCC-Inspections Job Address: 59 WEST MOUNTAIN RD Parcel Number: 307.-1-29 Queensbury, NY 12804 Contact Type Company Name Name Primary Owner East Slope Holding, LP Architect AJA Architecture & Planning Granted Permission East Slope Holding, LP Applicant Spencer Montgomery Checklist Item Status Fire Marshal Passed Exit Access Passed Exit Enclosure Passed Exit Discharge Passed Locks and Latches Passed Sign: Normal Passed Page(1) Sep 20,2019 Checklist Item Status Sign: Backup Passed Main Aisle Width Passed Secondary Aisle Width Passed Fire Extinguisher Hung Passed Inspection of Extinguisher Passed Evac Plan Passed Truss ID Signage Passed Emergency Lighting Interior Passed Emergency Lighting Exterior Passed Clearance to Electrical Passed Electrical Wiring Enclosed/Labeled Passed Sep 20,2019 Page(2) Checklist Item Status Combustibles in Equipment Rooms Passed Storage Passed Interior Finishes Passed CO Detectors Passed Clearance to Sprinkler/Ceiling Passed Hood Installation Passed 8/20- need to verify fan override function FIRE ALARM Annual Passed Sprinkler System Annual Passed Sprinkler FDC Passed Kitchen Suppression Semi Annual Passed 8/20-function test was successful however shunt trip is required for electric outlets behind appliances Hood Cleaning 3-6 Annual Passed Knox Box: installed/checked Passed Sep 20,2019 Page(3) Checklist Item Status Occupancy Cycle Passed A Palmer,Mike Sep 20,2019 Page(4) Town of Queensbury- Building and Codes- Fire Marshal 742 Bay Road-(518)761-8256 Building (518) 761-8206 Fire Marshal Case Number: CC-0539-2018 Case Module: Permit Inspection Date: Tue Aug 20, 2019 Inspection Status: Partial Pass Inspector: Mike Palmer Inspection Type: OCC-Inspections Job Address: 59 WEST MOUNTAIN RD Parcel Number: 307.-1-29 Queensbury, NY 12804 Contact Type Company Name Name Primary Owner East Slope Holding, LP Granted Permission East Slope Holding, LP Architect AJA Architecture& Planning Applicant Spencer Montgomery Checklist Item Status Fire Marshal Passed Exit Access Passed Exit Enclosure Passed Exit Discharge Passed Locks and Latches Passed See email Sign: Normal Passed Aug 20,2019 Page(1) Checklist Item Status See email Sign: Backup Passed See email Main Aisle Width Passed Secondary Aisle Width Passed Fire Extinguisher Hung Passed Inspection of Extinguisher Passed Evac Plan Passed Truss ID Signage Passed Emergency Lighting Interior Passed See email Emergency Lighting Exterior Passed Seeemail Clearance to Electrical Passed Electrical Wiring Enclosed/Labeled Passed See email Aug 20,2019 Page(2) Checklist Item Status Combustibles in Equipment Rooms Passed Storage Passed Interior Finishes Passed CO Detectors Passed Clearance to Sprinkler/Ceiling Passed Hood Installation Failed 8/20-cannot find make up air. If external to hood, show were it comes in and a balancing report 8/20- need to verify fan override function 8/20-need grease light test reports FIRE ALARM Annual Passed Sprinkler System Annual Passed Sprinkler FDC Passed Kitchen Suppression Semi Annual Failed 8/20-function test was successful however shunt trip is required for electric outlets behind appliances Hood Cleaning 3-6 Annual Passed Aug 20,2019 Page(3) INSPECTION WORKSHEET1 1 • 1 Checklist Item Status Knox Box: installed/checked Passed Occupancy Cycle Passed A Palmer,Mike Aug 20,2019 Page(4) a , Town of Queensbury- Building and Codes- Fire Marshal 742 Bay Road-(518) 761-8256 Building (518)761-8206 Fire Marshal Case Number: CC-0539-2018 Case Module: Permit Inspection Date: Mon Aug 5, 2019 Inspection Status: Partial Pass Inspector: Mike Palmer Inspection Type: OCC-Inspections Job Address: 59 WEST MOUNTAIN RD Parcel Number: 307.-1-29 Queensbury, NY 12804 Contact Type Company Name Name Applicant Spencer Montgomery Primary Owner East Slope Holding, LP Architect AJA Architecture& Planning Granted Permission East Slope Holding, LP Checklist Item Status Fire Marshal Passed Exit Access Passed Exit Enclosure Passed Exit Discharge Passed Locks and Latches Passed See email Sign: Normal Passed Aug 05,2019 Page(1) f� Checklist Item Status See email Sign: Backup Passed See email Main Aisle Width Passed Secondary Aisle Width Passed Fire Extinguisher Hung Failed See email Inspection of Extinguisher Failed See email Evac Plan Passed Truss ID Signage Failed See email Emergency Lighting Interior Passed See email Emergency Lighting Exterior Passed Seeemail Clearance to Electrical Passed Electrical Wiring Enclosed/Labeled Passed See email Aug 05,2019 Page(2) Checklist Item Status Combustibles in Equipment Rooms Passed Storage Passed Interior Finishes Passed CO Detectors Passed Clearance to Sprinkler/Ceiling Passed Hood Installation Failed See email-cannot find make up air. If external to hood, show were it comes in and a balancing report FIRE ALARM Annual Passed See email Sprinkler System Annual Passed See email Sprinkler FDC Passed Kitchen Suppression Semi Annual Failed See email Hood Cleaning 3-6 Annual Passed Knox Box: installed/checked Passed Aug 05,2019 Page(3) Checklist Item Status Occupancy Cycle Passed A Palmer,Mike Aug 05,2019 Page(4) Town of Queensbury-Building and Codes- Fire Marshal 742 Bay Road-(518)761-8256 Building (518)761-8206 Fire Marshal Case Number: CC-0539-2018 Case Module: Permit Inspection Date: Fri Jun 28, 2019 Inspection Status: Failed Inspector: Mike Palmer Inspection Type: OCC-Inspections Job Address: 59 WEST MOUNTAIN RD Parcel Number: 307.-1-29 Queensbury, NY 12804 Contact Type Company Name Name Architect AJA Architecture & Planning Applicant Spencer Montgomery Granted Permission East Slope Holding, LP Primary Owner East Slope Holding, LP Checklist Item Status Fire Marshal Passed Exit Access Passed Exit Enclosure Passed Exit Discharge Passed Locks and Latches Failed See email Sign: Normal Failed Jun 28,2019 � ��� a� Page(i) Checklist Item Status See email Sign: Backup Failed See email Main Aisle Width Passed Secondary Aisle Width Passed Fire Extinguisher Hung Failed See email Inspection of Extinguisher Failed See email Evac Plan Passed Truss ID Signage Failed See email Emergency Lighting Interior Failed See email Emergency Lighting Exterior Failed Seeemail Clearance to Electrical Passed Electrical Wiring Enclosed/Labeled Failed See email Jun 28,2019 Page(2) Checklist Item Status Combustibles in Equipment Rooms Passed Storage Passed Interior Finishes Passed CO Detectors Passed Clearance to Sprinkler/Ceiling Passed Fuel Pump Warning Signs Failed Hood Installation Failed See email FIRE ALARM Annual Failed See email Sprinkler System Annual Failed See email Sprinkler FDC Passed Kitchen Suppression Semi Annual Failed See email Hood Cleaning 3-6 Annual Passed Jun 28,2019 Page(3) ,'408i Checklist Item Status Knox Box: installed/checked Passed Occupancy Cycle Passed A Palmer,Mike Jun 28,2019 Page(4) F -. # ' �. [t t i 1f. Town of Queensbury FIRE MARSHAL'S OFFICE FIRE ALARM SYSTEM INSPECTION DATE: ✓1 �Ll FA CONTRACTOR � ' ~I r LOCATION: V;c7l 'Anl-' CENTRAL STATION TIE IN AND CONFIRMED COPY OF LICENSE FIRE ALARM PLANS AND CUT SHEETS PROVIDED RECORD OF COMPLETION PROVIDED NFPA 72 INSPECTION REPORT PROVIDED FIRE DEVICES VISIBLE DO NOT RESET STICKER ON PANEL ZONE CHART PROVIDED STROBE FUNCTION ON SILENCE ACTIVE/ DISABLED ALL REQUIED KEYS PROVIDED FUNCTION TEST: PULL STATION SMOKE DETECTOR HEAT DETECTOR HORN STROBE HVAC SHUTDOWN ANSUL TIE IN FUEL ISLAND TIE IN TAMPER i FLOW +f� i CO DETECTION _ PROTECTION SYSTEM NEW YORK FIRE&SECURITY INSPECTION REPORT 4 Glens Falls Technical Park Glens Falls,NY 12801-3802 DATE OF ORDER 6-13-2019 WORK ORDERED BY (518)798.9551 ORDER TAKEN BY PHONE Fax(518)792-5199 P.G.NO West Mt Ski Area JOBNAMEING _ 59 West Mt Rd "LOCATION Acct#OJ2838 Queensbury NY 12804 INSTALLATION DATE LAST INSPECTION 11-8-2018 INVOICE GATE JOB PHONE INSPECTION INFORMATION SYSTM INFORMATION 4 SYSTEM EQUIPMENT MANUFACTURE Silent Knight SK 5820 XL 4 �' 4 k R.O.R. 26 SYSTEM INSTALLER NYFS � Fixed Heat SYSTEM APPLICATION Ski Lodge Photoelectric 31 Ion TYPE OF SYSTEM Fire Alarm Duct MAINTENANCE PROGRAM BY NYFS Flame CALL LIST UP TO DATE Manual 16 v ❑Yes �N-.; Z G" Cross Zone REMARKS t= ACCT NUMBER OJ2838 Single Zone -- — ------ --- Contacts Motions Photobeams CONTROL PANEL AGENT TANK COMMUNICATIONS DEVICES Water Flow 1 Low Air 1 A.C.Voltage 125.9 Weight A.C.Voltage Sprinkler Tamper 1 D.C.with Load Last Hydro D.C.Voltage Bed Shaker Elev/Shunt Trip 1 D.C.without Load 26.6 Gauge Pressure D.C.without Load Air Hand. 2 Batt A 12.59 serial# Ansel 2 Door Release Duct Damper Batt B 12.60 Equipment Shutdown CO Detector added and inspected Additional devices added for remodel ij A.C.Voltage _ v BZ4. D.C-Voltage IBattery J Z Detection Circuit0 Audible Circuit --- Remote Activation gi. Audible Devices 18 Visual Devices 24 Pre.Discharge Signs As Needed Selector Valves Piping [0 The testing performed and noted on this inspection report is based on NFPA 72 guidelines Nozzles sW Tanks - uf Gauges — INSPECTOR vy "Z{ Piston Activator TD/BF hereby acknowledge the satisfactory completion Q SYSTEM FUNCTIONAL Solenoid of the above described work. Manual Release ❑ SYSTEM NON-FUNCTIONAL Time Delay -- Remote Station Trans. � Digital Dialer � DISCREPANCIES x.Ia NOTED ABOVE pVoice Dialer Ayr 6-13-2019 Phone Line Signature(Title) Date