Loading...
RC-0352-2019TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518) 761-8201 Yry' u G" 4 Community Development - Building & Codes (518) 761-8256 BUILDING PERMIT Permit Number: RC-03 52-2019 Tax Map No: 295.15-2-13 Permission is hereby granted to: FOOTHILLS BUILDERS, LLC For property located at:55 JOHN CLENDON RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: John Clendon Hidden Estates LL Single Family-New 1501000.00 Owner Address: 9 Mountainside DR Total Value 1501000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency FOOTHILLS BUILDERS,LLC 9 Mountainside DR Queensbury,NY 12804 Plans&Specifications Single Family Dwelling w/gas FP 1437 s.f. Garage 484 s.f. Lot 16 731.10 PERMIT FEE PAID -THIS PERMIT EXPIRES: Wednesday, June 10, 2020 If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury; Tuesday, June 11, 2019 SIGNED BY:for the Town of Queensbury. Director of Building&Code Enforcement Office Use Only PRINCIPLE STRUCTURE PERMIT Permit#: 4 APPLICATION Permit Fee:$ r5,.I O 742 Bay Road Queensbury, NV 12804 Rec. Fee:$ N114 P 518-761-8256 Invoice#: 151 1p Project Location: ' 30 14 iJ C L(N00 pD Tax Map #: 7-9 S , / S- - - 13 Subdivision Name: O RP r Pi/Apt-0 TOWN BD RESOLUTION 86-2013 $850 recreation fee for new dwellingunlis single du 5 f j family. p; <:;s-two-family: muitipiefamily. apartments condominiums townhouses,and car manufactured i modular homes but not mobile homes. This is in addition to the permit fee(s). CONTACT INFORMATION: Applicant: Name(s): E0 oTHI OA )3uit_DERS (ToC Liu<--i Mailing Address, CIS/Z: LI m b rid TA I tu5 c O b R.i vi= tut s8,4Izy Pk( i2.ra`1 Cell Ph.: t ( si ) -7'1 - t11 33 Land Lire: i (St1 ) iRra-3sZo £CEzA-) Email: Foo Ttili-LSaurL-Degst.ryg GmAJLec0rv\ Primary Owner(s): Name(s): StckME As APPt-Ic.flri7 Mailing Address, CISIZ: y \ Cell Ph.:L „Land Line: i,/ r ____...„ y eti/Email: Contractor(s): 3o7/]2019 Name(s): S Arne- AS A PpL CAN i TOBU 0, QUaEEN RbsBU Mailing Address, CISIZ: CCB€ r,/ Cell Ph.:Land Line: ( Email: Architect(s)/Engineer(s): Name(s): bRt.) yA1-J , PE CYiS1t?tJ r£r1L 1NE-e1~1ic-- ) Mailing Address, CISIZ: Soo G-L NJ 5 cLu re 5(0 G-Lt s FALO N '-f )2 O I Cell Ph.: _._...( Land Line: I ( 5'1 ? ) 79 2 - 12leti Email: 1)Rlii J trISlotJErvG- . emA1ir. Contact Person for Building & Code Compliance: 3c6 Lt;V'C.1 Cell Ph.: 1 (S-t ' ) 111- 1133 Land Line: i ( I S ) 1 q -3SZ.6 (46-L0 Email: Eoo T tkit-LSGuI Li)Ct2-SjJ`1( G MAII--- C..o reN Tr,O Ruildine R rndp FnfnrrQrnent Princinle Struriure Rrvi;nd Mardi 7QIR PROJECT INFORMATION: TYPE: Commercial V Residential WORK CLASS: Single-Family Two-Family Multi-Family(#of Townhouse Business Office Retail Hotel/Motel Industrial/Warehouse Garage(#ofcars ) Other(describe STRUCTURE SQUARE FOOTAGE: GARAGE SQUARE FOOTAGE: 1floor. (J3-7 1sT floor: La LI 2" floor: " 7 2d floor: srd floor: L/c L/Total square feet: Basement(habitable space): Total square feet: 1 L/3- ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction:$I S O CrO 0 2. Proposed use of the building: ff5 )b i to 3. If Commercial or Industrial,indicate the name of the business: 4. Source of Heat(circle one): ig Oil Propane Solar Other: Fireplaces need a separate Fuel Burning Appliances&Chimney Application,one per appliance) 5. Are there any structures not shown on the plot plan? YES N Explain: 5. Are there any easements on the property? YES 7, SITE INFORMATION: a.What is the dimensions or acreage of the parcel? 0 , 8 b. Is this a corner lot? YES c.Will the grade be changed as a result of the const '.a_ YES d.What is the water source? PUBLIC PRIVAT WELL e. Is the parcel on SEWER or a PRIVATE SEPTIC system? PIZ I v A 1C TOO Ruil din¢R(-Atli.FnfArfPR1ArN Prinrinia Sfnirfnri RPvicnri Mardi 7l7R DECLARATION: I. I acknowledge that no construction shall commence priorto issuance of a valid building perm and work will be completed within a 12 month period. 2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approve 1. 3. I certify that the application, plans and supporting materials are a t rue and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local buikling laws and ordinances, and in conformance with local zoning regulations. 4, I acknowledge that prior to occupying the facilities proposed I,or my agents, will obtain a certificate of occupancy. 5. I understand that lance are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: -ToS €P )4 Le SIGNATURE: Off\A 31111" BATE; TOO Building&Code Enforcement Prinrinia StnErta,ro RavicPri March 7M Office Use Only FUEL BURNING APPLIANCE & Permit#:_ 0--(..._—0 b2._•-2-0 11CHIMNEYAPPLICATION•-..., i i,.= Permit Fee:$t4;;:e0 -',1.'•,, Invoice it 74, 6d, Road. Queensbu , N 2804 P. 51.; 761-8256 Project Location: SS 3-014) CL6-1'-'"'s) Tax Map ID: 2-1 S-- - I S-- 2- - IS Room of Install: G-g-trwr agnt, Planned Install Date: -7) ) V iz,0 fq ONE APPLICATI ON PER APPLIANCE** CONTACT INFORMATION: Applicant: Name(s): FooTH i L-Ls Olik it_bEg. LL.c (:RE Leu C Mailing Address, C/S/Z: 61 1110LN,•)-ifiriv4./D6 De- Que e--,p•i-5 go P-1 N j i l_g O 1 Cell Ph.: I (c-ig ) 19 1- (6133 15te4 Line: f ( Cig ) -716 -3S-2.0 ct,-,-u-) Email: Foo-niiiLs 60,103e-0 NI 1 6:), C-In ti 1 L,co ryk Primary Owner(s): Name(s): SA revE— OS AP f L 1 ( (V r47 Mailing Address, C/SIZ: Cell Ph.: ( Land Line: ( Email: Installer/Builder: Name(s): Sta ro Mailing Address, C/S/Z: Cell Ph.: ( Land Line: ( Email: Contact Person for Building & Code Compliance: T3 E I-E Lk c I Cell Ph.: I (c-(r ) -rt I - 1133 band Line: ii 5"I S' ) 11 6 - 3 s-2-0 (c_e1-1--) Email: -g..9-6--F-1444;4;s3=4v,„- Foo-FH 11-“etAiLDE Ks wte C-IY‘Mb. L-0 ty>, Town of Otx-ensoury Budd ri .,,'-ii,Enforcement FUEL BURNING APPLIANCE INFORMATION: TYPE OF DEVICE: Stove X Fireplace Insert Fireplace t,\ i i i€ m°Li1,3171 N Shcb IJvb 3(0 P3oN IA HOC Dlr -AXE Fuel Fired Equipment(Garage Only,13"clearance per 1MC 304.3) Fireplace, factory built** Manufacturer's Name: Model#: SOURCE OF HEAT: Wood Coal Pellet Gas CHIMNEY INFORMATION: Masonry: block brick stone Flue: tie st) /size,in inches Material*: double-wall triple-aura!!_insulated Manufacturer's r-i r r-i eat_ Model#: ADDITIONAL INFORMATION: L Two inspections are required. A rough-in inspection,prior to installation and a final inspection,after installation. 2 Manufacturer's installation manual must be available at the time of inspection. 3 Masonry fireplaces &chimneys require plans to be submitted. 4 Twenty-four (24)hour notification is required for inspections. Declaration:Constructiontnstallation must conform to NYS Fire Prevention&Building Code and/or manufacturer requirements,The applicant or owner agreesto comply with all applicable laws,ordinances,regulations and all conditions that are part ofthese requirements and also will allow the inspector to enter the premises to perform the required inspections. I have read and agree to the above: PRINT NAME: .1303€PH L£u SIGNATURE:ATE: S 'Jo)' Fuel Burning Appliance&Chimney Application SEPTIC DISPOSAL PERMIT APPLICATION use c_.,,1 7 Bay Road,Qu: ensbury.\1- i-N0-t P518-76.-,:'56 Perm: (LC -bb`DZ' 1 Tax Map ID#: v`Zf Project Location: 3:Eolce a i Primary Owner(s) 1 TO c T I-t i .-t S Av-i L b e Q S 1_L-C (ac C Levi e i) Mailing Address i GLA-tsiTA WSIDE' R QU-6 uSBc0?-.1 I` 11 12goli Phone & Email ie) l`t!-t`f33 7cf._. 52 RNyG A)LrGOrtCoi(EtLZ5f3 L installer/Builder I Some- Rs 119Pc.i(R.nfr Mailing Address Phone & Email Engineer i, Mailing Address hol WW1LANi] RD Ike- NSt3i`tits1 AJ1 t210I Phone& Email 1-- l (s-ii)-19(0-zs--1 S ¶ r•i-I6-f.3( Q yA Noo, tor" Contact Person for Buikling&Code c raprliara :, LE c-) Phc r : (s 1$)i'i 1 ` 19 33 RESIDENCE NFORMATION: c1 ` `3, 2 0 Year Built # of bedrooms X gallons per bedroom = totaldaily flow Garbage Grinder Yes N 7980 or older installed? {circle one) 1981-091 Spa or Hot Tub Yes N 14g2 Pr-sen G 3 Installed? {circle one) i`_- PARCEL NFORMATION: Topography K Flat Rolling Steep Slope Slope Soil Nature Sand Loam Clay _Other Groundwater ._..__.,. ,_ ' At what depth? / / _.._._.._._ Bedrock/lmperviousmateriai At what depth? N /A Domestic Water Supply 1" Municipal _Well{if well,water supply from any septic system absorption is It.) Percolation Test Rate:)-c per minute per inch(test to be completed by licensed engneer/arcttect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: Tank size ) 6 0 t ga lions{min.size 1000 ga lions,add 250 ga lions for each garbage cylinder or spa/hot tub MEIAbsorption field with#2 stone Total length i CO ft.:Each Trench C 6 ft. __ ..-_._—.__ IIIIIIIIIIIII Seepage Pit with#3 stone How many: Size: Alternative System Bed or other type: Holding Tank System Total required capacity? tank size of tanks NOTES:1.Alarm system&associated electrica lwork must be inspected bya Town approved electrical inspection agency:2,We will no longer allow systems to be covered until such time as an as-built plan is received and approved. The installed system must match the septic layout on file-no exceptions. Declaration:Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void have read the regulations and agree to abide by these and all requirements of theTown ofQueensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: i g S Cr W c I DATE: S 36 I l SIGNATURE: 1/4-6 \ 34 l DATE: ro'in'0c... ,,,., ,E. Code En`orcement Town of Queensbury David Duell Highway Superintendent Highway t` qt 518-761-8212 Department 742 Bay Road—Queensbury,NY Mark Benware 12801 Deputy Highway Superintendent Phone: (518) 761-8211 518-761-8210 Fax: (518) 745-4466 DRIVEWAY PERMIT DATE: S )36 APPLICANT NAME:f o 6 N ILLS But I W US CSoE LELt TELEPHONE NO.:1071 l-1933I(St81716- 20 ADDRESS TO BE INSPECTED: C-' Ja Nw C LE:is Dt P RETURN ADDRESS:9 lY-10\,,,--c.ft,1 D C D B fl 7_8-6 Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location. The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: Preliminary Approval NEED: Slight swale Deep swale Level with the road Level with the top of the paved wing Size culvert pipe to be used (if necessary) 12" ( ) 15" ( ) 18" ( ) 24" ( ) 36" Preliminary inspection completed by: Date: Approval by Highway Supt: or) Deputy Supt: Upon completion, please resubmit this approved permit for a final approval. STEP 2: Final Approval ( ) Rejected Date: David Duell, Highway Superintendent Mark Benware, Deputy Highway Superintendent REScheck rsii Compliance Certificate Project Foothills Builders Energy Code: 2015 IECC Location: Glens Falls, New York Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 1,437 ft2 295.15-2-13 RC-0352-2019 Glazing Area 11% Foothills Builders Climate Zone: 6 (7635 HDD) Permit Date: 55 John Clendon Rd, Lot 16 Permit Number: SFD w/gas FP 1437 s.f., Gar. 484 s.f. Construction Site: Owner/Agent: Designer/Contractor: John Clendon Drive Daniel W Ryan PE Lot 16 206 Glen Street Queensbury, NY 12804 Suite 30 Glens Falls, NY 12801 518-792-9264 dryan@dwrpe.com Compliance: 0.4%Better Than Code Maximum UA: 241 Your UA: 240 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or R-Value R Value U-Factor UA Perimeter Ceiling 1: Raised or Energy Truss 1,437 42.0 0.0 0.023 33 Wall 1: Wood Frame, 16" o.c. 1,560 21.0 0.0 0.057 78 Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 132 0.290 38 Door 1: Solid 18 0.140 3 Door 2: Solid 20 0.240 5 Door 3: Glass 18 0.290 5 Floor 1: All-Wood Joist/Truss:Over Outside Air 12 30.0 0.0 0.033 0 Basement Wall 1: Solid Concrete or Masonry 1,443 0.0 15.0 0.046 65 Wall height: 7.8' Depth below grade: 6.8' Insulation depth: 7.8' Window 2: Vinyl/Fiberglass Frame:Double Pane 7 0.400 3 Window 3: Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.290 5 Basement Wall 2: Solid Concrete or Masonry 78 0.0 10.0 0.061 5 Wall height: 7.8' Depth below grade: 6.8' Insulation depth: 7.8' Project Title: Foothills Builders Report date: 04/28/19 Data filename: C:\Users\lrobision\Desktop\1430 Rescheck.rck Page 1 of10 Compliance Statement: The proposed building design described here is consistent with the building plans,specifications, and other calculations submitted with the permit application.The proposed buil ' g has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.4 and to comply with the mandatory require e s listed in the REScheck Inspection Checklist. clfr%'jb6- Name-Title Sig t Da 7z,--.1 C;t 4 L ¢ r Project Title: Foothills Builders Report date: 04/28/19 Data filename: C:\Users\Irobision\Desktop\1430 Rescheck.rck Page 2 of10 REScheck Software Version Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans.Verified Field Verified Pre-Inspection/Plan Review Value Value Complies? Coo ents/A sa mp ions RetpID 103.1, Construction drawings and Complies 103.2 documentation demonstrate Does Not PR1]i energy code compliance for the Not Observable building envelope.Thermal envelope represented on Not Applicable construction documents. 103.1, Construction drawings and Complies 103.2, documentation demonstrate Does Not 403.7 energy code compliance for PR31i lighting and mechanical systems. Not Observable Systems serving multiple Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr Does Not PR212 on loads calculated per ACCA Cooling: Cooling: Manual.] or other methods Not Appervable approved by the code official. Btu/hr Btu/hr1 Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Report date: 04/28/19 Data filename: C:\Users\lrobision\Desktop\1430 Rescheck.rck Page 3 of10 Section- Flans Verified Fieldllf6FoundationinspectionValuevalueerifi Complies3 CczmmentsfAs umpdons sID 402.1.1 Conditioned basement wall R- R- Complies See the Envelope Assemblies FO4]1 insulation R-value.Where interior R R_ Does Not table for values. insulation is used,verification may need to occur during Not Observable Insulation Inspection. Not Not Applicable required in warm-humid locations in Climate Zone 3. 303,2Conditioned basement wall r j Complies F05]i insulation installed per El Does Not Emanufacturer's instructions.le) r ' Not Observable Not Applicable 402.2.9 Conditioned basement wall ft ft Complies See the Envelope Assemblies F06]1 insulation depth of burial or Does Not table for values. distance from top of wall. Not Observable Not Applicable 303.2.1 A protective covering is installed # ,wPr f Complies FO1112 `toprotect exposed exteriors xp Does Not insulation and extends a j minimum of 6 in. below grade. 1 Not Observable a ;.µ, Not Applicable 403 9 . Snow-and ice-melting system Complies F01212, controls installed.Does Not j Not Observable 3K Not Applicable s v u u.e t6 a kzy.vg Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Report date: 04/28/19ProjectTitle: Foothills Builders Data filename: C:\Users\Irobision\Desktop\1430 Rescheck.rck Page 4 of10 i Section Plans Verified Field lteri#ied . Framing/Rough-In Inspection- Complies? Comments/Assumptions et(.ID _ ValueValue 402.1.1, Door U-factor.U- U- Complies See the Envelope Assemblies 402.3.4 Does Not table for values. FR1]1 Not Observable ; Not Applicable 402.1.1, Glazing U-factor(area weighted U U- Complies See the Envelope Assemblies 402.3.1, average). Does Not table for values. 402.3.3, Not Observable 402.3.6, 402.5 ENot Applicable FR2]1 l 303.1.3 ''U-factors of fenestration products Complies FR4]1 are determined in accordance Does Not with the NFRC test procedure or taken from the default table. Not Observable 1,1 Not Applicable E 402.4.1.1 ;Air barrier and thermal barrier Complies FR23]1 installed per manufacturer's Does Not 44) instructions. ENot Observable Not Applicable 402.4.3 ;Fenestration that is not site built Complies FR20]1 is listed and labeled as meeting Does Not ti AAMA/WDMA/CSA 101/1.5.2/A440 Not Observable or has infiltration rates per NFRCi 400 that do not exceed code Not Applicable limits. O24.5 ' ,IC-rated recessed lighting fixtures 1.,' : ElComplies FR16]2 sealed at housing/interior finish `a Does Not and labeled to indicate <_2.0 cfm leakage at 75 Pa. ENot Observable Not Applicable 403.2.1 ;Supply and return ducts in attics `' Complies FR12]1 insulated >= R-8 where duct is ElDoes Not 3 inches in diameter and >_ Not Observable R-6 where < 3 inches.Supply and return ducts in other portions of ENot Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 ;Building cavities are not used as Complies FR15]3 'ducts or plenums. Does Not s ENot Observable Not Applicable 4t)34 ;HVAC piping conveying fluids ; R- R- Complies FR17]2 [above 105 °F or chilled fluids Does Not below 55 °F are insulated to >_R : ID Not ObservableV3.EN ot Applicable 403.4.1 ;Protection of insulation on HVAC Complies Piping. Does Not ENot Observable ENot Applicable 403.5.3 Hot water pipes are insulated to R- R-Complies FR78]2 .' >_R-3. Does Not r ENot Observable ENot Applicable 403,E ,Automatic or gravity dampers are[ -` ` ' Complies FR1912 ;installed on all outdoor air Does Not intakes and exhausts. i ENot Observable I ENot Applicable , 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) l Project Title: Foothills Builders. Report date: 04/28/19 Data filename: C:\Users\Irobison\Desktop\1430 Rescheck.rck Page 5 of10 Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Report date: 04/28/19 Data filename: C:\Users\Irobision\Desktop\1430 Rescheck.rck Page 6 of10 t Section Plans Verified Field Verified insulation Inspection Value Value Complies? Comments/Assumptions Req.113 303,1 ;All installed insulation is labeled Complies IN1312 or the installed R-values Does Not provided. Not Observable j Not Applicable 402.1.1, Floor insulation R-value. R- R- EComplies See the Envelope Assemblies 402.2.6 Wood Wood Does Not table for values. IN111 Steel Steel Not Observable s.Not Applicable 303.2, ;Floor insulation installed per 1 Complies 402.2.7 :manufacturer's instructions and Does Not IN2]1 in substantial contact with the Not Observable underside of the subfloor, or floor. framing cavity insulation is•in Not Applicable contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. i- _ 402.1.1, Wall insulation R-value. If this is a R- R- EComplies See the Envelope Assemblies 402.2.5, mass wall with at least 1/ 2 of the Wood Wood Does Not table for values. 402.2.6 ,wall insulation on the wall Mass Mass Not Observable IN3]1 ;exterior,the exterior insulation requirement applies (FR10). ;El Steel ID Steel Not Applicable 303.2 Wall insulation is installed per Complies IN4]1 manufacturer's instructions. ! ',Does Not Not Observable i x'' Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Report date: 04/28/19 Data filename: C:\Users\Irobision\Desktop\1430 Rescheck.rck Page 7 of10 ctiOn plane verified F1s1rt.lPe 'shedF€ l Lne aect[oe , to isi s Complies? Comments/Assn ptions Req.lf'u AJaI[t lflue 1 _ , 402.2.1, ' Ceilinginsulation R-value. III Wood Wood Doespltes See the Envelope assembliesR- 402.2.2, Not table for values. 402.2.E Steel Ell Steel Not FIl]1 ( Not Applicable 303.1.1.1, :Ceiling insulation installed per Complies 303.2 :manufacturer's instructions. Does Not FI2]1 Blown insulation marked every 300 ft2.Not Observable Not Applicable 402.2,3 ;Vented attics with air permeable Complies fF12212 l insulation include baffle adjacent , Does Not to soffit and eave vents that i Not Observable£d _5 qextendsoverinsulation. a Not Applicable 402.2.4 Attic access hatch and door R- R- Complies Fl3]1 insulation >_R-value of the 10Does Not adjacent assembly. Not Observable Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = Complies FI17]1 ach in Climate Zones 1-2, and ElDoes Not 3 ach in Climate Zones 3-8. Not Observable Not Applicable 403.2.3 ;Duct tightness test result of<=4 cfm/100 cfm/100 Complies FI4]1 :cfm/100 ft2 across the system or ft2 ft2 Does Not 3 cfm/100 ft2 without air Not Observablehandler@25Pa. For rough-in tests,verification may need to Not Applicable occurduring Framing Inspection. 403.3.2----1 Ducts are pressure tested to cfm/100 cfm/100 Complies FI27]1 determine air leakage with ft2 ft2 Does Not either: Rough-in test:Total leakage measured with a Not Observable pressure differential of 0.1 inch Not Applicable w.g.across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air: handler leakage designated EiComplies FI24]1 by manufacturer at<=2%of Does Not design air flow. Not Observable Not Applicable 403.1.1 :Programmable thermostats Complies F19]2 :installed for control of primary Does Not heating and cooling systems and s initially set by manufacturer to Not Observable '. code specifications. Not Applicable 40 1.2 ',Heat pump thermostat installed Complies F110]2 ;on heat pumps. e NoDotsObseNotrvable Not Applicable 403.5,1 ,Circulating service hot water Complies F11 j2 systems have automatic or Does Not accessible manual controls. Not Observable Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Report date: 04/28/19 Data filename: C:\Users\lrobision\Desktop\1430 Rescheck.rck Page 8 of10 ectiore Plans Verified Field Verified Final inspetf on Provisions Value Value C mpiies?rsar en sl ssurnPti n 5c keq,IT 4Q3.6.1 ;All mechanical ventilation system Complies F125]2 i fans not part of tested and listed Does Not HVAC equipment meet efficacy ON ot Observable and air flow limits. Not Applicable 403.2 Hot water boilers supplying heat Complies FI26]2 through one-ortwo-pipe heating Does Not systems have outdoor setback Nat Observable control to lower boiler water temperature based on outdoor Not Applicable temperature. 403 5 1 l Heated; water circulation systems Complies FF28]2 :have a circulation pump.The Does Not system return pipe is a dedicated Not Observable return pipe or a cold water supply pipe. Gravity and thermos- Not Applicable syphon circulation systems are not present. Controls for circulating hot water system ," pumps start the pump with signal' ' for hot water demand within the ; occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 4Q',5 1 2;Electric heat trace systems 1 Complies I"i29]2 ; comply with IEEE 515.1 or UL Does Not 515.Controls automatically adjust the energy input to the Not Observable heat tracing to maintain the Not Applicable desired water temperature in the piping E_ 4Q; .5.2. ''Water distribution systems that plies F130]2 I have recirculation pumps that Does Not pump water from a heated water Not Observable supply pipe back to the heated water source through a cold Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature E of the water entering the cold water piping to 104°F. 4Q3 5 4 Drain water heat recovery units Complies Fi31]2 tested in accordance with CSA Does Not 655.1. Potable water-side Not Observable pressure loss of drain water heat 3 recovery units< 3 psi for Not Applicable individual units connected to one ' or two showers. Potable water- s:' side pressure loss of drain water heat recovery units < 2 psi for individual units connected to j y three or more showers. 404.1 _ 75%of lamps in permanent t,:, ;' Complies FI6]i ',fixtures or 75%of permanent •^,fiL' s Does Not fixtures have high efficacy lamps Not Observable Does not apply to low-voltage s V,gam Not Applicable lighting. 4Q4,1.1 Fuel gas lighting s stems have Complies 9 9 Y N E[23]3 no continuous pilot light. e ' Does Not i #hay ':. Not Observable41)f Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders. Report date: 04/28/19 Data filename: C:\Users\Irobison\Desktop\1430 Rescheck.rck Page 9 of10 Section Mans Verified Field VerifiedFinalInspectionProvisions lal Value Complies? Comments/Assumptions Req.IC3 gi31.3 ;Compliance certificate posted. f r Complies F1'71 l Does Not Not Observable Not Applicable 303.3 ',Manufacturer manuals for 1 b i , 1 Complies F118]3 mechanical and water heating Does Not systems have been provided. E Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Report date: 04/28/19 Data filename: C:\Users\lrobision\Desktop\1430 Rescheck.rck Page 10 of10 L 'J Sit „G[,, i,ma,Jyy u4-01 A Ite f -" *e' Yrr b Above-Grade Wall 21.00 Below-Grade Wall 15.00 Floor 30.00 Ceiling / Roof 42.00 Ductwork (unconditioned spy&cues): Glass&Door Rating Window 0.29 Door 0.24 n In la .,.. ..Equipment Efficiency ., Heating System: Cooling System: Water Heater: Name: Date: Comments z 1doECM HEAT RECOVERY VENTILATOR ll No ENGINEERING DATA LIFEBRERTH II THERMALLY CONDUCTIVE,PATENTED DEFROST ALUMINUM CORE Recirculating damper defrost system. The counter-flow heat recovery core transfers heat between the two airstreams.It is easily removed for cleaning or service. CASE Twenty gauge prepainted galvanized steel for superior corrosion resistance.Insulated to MOTORS AND BLOWERS prevent exterior condensation.Drain connections 2-1/2 in.(12 rum)OD.Balancing ports High efficiency electronic commutate ECM motor,for maximum energy savings.Each are located on door. airstream has one centrifugal blower,with multiple fanspeed operations driven by one double shaft motor. ELECTRONICS The DXPLO2 control included with the unit can be wall mounted in a central location of FILTERS the home.3 wire 20 gauge(min.)100 ft length(max.). Washable antimicrobial MERV 6 air filters in exhaust and supply airstreams. MOUNTING WARRANTY Four threaded inserts at corners of the cabinet designed to accept the's' hooks and Units carry a lifetime warranty on the HPV core and a 5 year hanging straps supplied with the unit. replacement parts warranty. OPTIONAL ACCESSORIES: Weather Hood TechGritte 99-EAG4 Terminator Wireless 20/40/60 99-185 9-EAG Fitting Min Timer 99-186 15 99 EAG6 99-TM4 99-DET02 by 99187 99-EAG8 i, 99-TM6 LIFEBREATH CONTROL OPTIONS TIMER OPTIONS 99-DETO1-Lifebreath 20/40/60 Minute Timer FEATURES 99-DXPLO2 99-BCO2 99-BC03 99-BC04 Initiates high speed Ventilation for 20,40 or 60 minutes.3 wire connection. 5 speed fan operation on each mode 99-DET02 2 speed fan operation(Low/High) V Wireless Lifebreath 20/40/60 Minute Timer Continuous low speed fan operation V Initiates high speed Ventilation for 20,40 or 60 minutes.Wirelessly connects to main control for Humidity control through adjustable Dehumidistat V V V ease of installation.40'approximate range. Excusive to Lifebreath. Large digital LCD screen 99-RX02-Wireless Lifebreath Repeater LED status indicator lights V V V Extends range of 99-DET02 Wireless Timers.Plugs into 120V power outlet.Wirelessly connects to Continuous Ventilation main control and 99-DET02.Install at halfway point between timer and main wall control if timer Continuous Recirculation is out of range. 20 ON/40 OFF 10 0N/50 OFF I-fill f 20 ON/40 Recirculation V V V 1 _- _ U(t'c# (0 o f 20/40/60 min.High speed override button 99-DXPLO2 99 BEToz Compatible with 99-DET02 Wireless Timer V I 3 wire connection V V V V LIFEBRERTH' 1118 Indoor Air Systems 100ECM(9-11-18) www.lifebreath.com iv 1 OECM 4,,, HEAT RECOVERY VENTILATOR r zlt PERFORMANCE (HVI CERTIFIED) th. LIFEBRERTH'111 as 0.1(25) 0.2(50) 0.3(75) 0.4(100) 0.5(125) 0.6(150) ELECTRICAL SPECIFICATIONS i" IN.W.G.(PA) [ FM(L/s) [FM(L/s) [FM(L/s) CFM(L/s) CFM(Lis) [FM(Lis) VAC @ 60Hz 120 Net Supply Airflow 161(16) 143(68) 129(61) 114(54) 97(46) 78(37) Watts/Low Speed 40 Gross Supply Airflow 165(18) 147(69) 131(62) 111(55) 102(48) 81(38) Watts/High Speed 115 Gross Exhaust Airflow 229(108) 215(101) 210(99) 203(96) 184(81) 142(67) Amp Rating 1.75 Sensible Effectiveness(ASE) 180 WEIGHT: @ 64 CFM(30 Us) 32°F(0°C) 78% 160 71 LBS(32 EKG) Sensible Efficiency(SRE) 32°F(0°C) 11% 140 SHIPPING WEIGHT: @ 64 CFM(30 Us) E in 73 LES Q33 MG) u Sensible Efficiency(SRE) 32°F(0°C) 69% 3 loci @ 95 GEM(45 Us) so GTE::Sensible Efficiency(SRE) a @ 68 CFM(32 Us) 13°F(-25°C) 64% 60 Front clearance of 25 in.(635 mm)is o recommended for servicing unit.All ducts 20 use 6 in.(152 mm)round collars.Balancing e ISO dampers are located in all air streams. z,00I, 44104,oI 0.2 0.3 0.4 0.5 0.6 us FIVI 9001 0._. , o„,„..,...d, CERTIFIED REGISTERED Static Pressure(in w.g.) DD f)v EN5ION5 FRONT VIEW SIDE VIEW O Filter 143/4 in.(375 mm) ill' Recirculating Defrost =1111 rI 1 IDamperA Removable le\WIIIIII/ •'\ i IlN Blower Heat 11RecoveryI/ Motor Stale air to outside Core i O Fresh air from outsiderStaleairfrominside I Fresh air to insideQ 6ouin. n(1d52Collammrs) l 33 5/8 in.(854 mm) — ,I o v R Date:WARRANTY Contractor: _ Units carry a lifetime warranty Tag: on the HRV core and a 5 year replacement parts warranty. Project' Oty:Supplier: Engineer: Quote#: All units conform to CSA and UL standards If Control: Submitted By: LIFEBRE/ /Q THI If Indoor Air Systems Timer: Timer Qty: 100ECM(9-11-18) www.lifebreath.com EXHAUST 5 Y 5 a a:.ata. ig Iii[ s''' i#:„:4. TABLE Ni150T•3a3(1EHOUSEMECHANICALVENTILATIONSYSTEMAIRFLOWRATEREQUIREMENT NUgER OF BEDROOMS k 1111101311111111111111312111111111 5-7 7 ram DWELLING AREA 0-1 Airflow In CFM r1:!-_, FLOOR Aeet) 90 square feet} 60 75 30 45 75 105 1,500 60 75 j,, 1,501-3,000 15 95 105 105 120 60 75__ 1205 135 t:`:-` 3,001—4,500 I 90 105 150 6, 501—67,500 75 120 IIIIMIIIIIII 90 105 150 165 6,0> 7,5000000 105 120 135 i.For SI: i square foot=0.0929 m2,1 cubic foot per minute=0.0004719 m3/s. fill TABLE M15a7,3.3(2)INTERMITTENT WHOLE-ROUSE MECHANICAL VENTILATION RATE FACTORS, nl GMENT 255o% 33% i v . RUN-TIME PERCENTAGE INEACH 4-HOUR1 5 1.3 4. Facto permitted to be determined by interpolation. it a.For ventilation system run time values between those given,the factors are,: r-:,.. q;;;, b.Extrapolation beyond the table is prohibited. F i TABLE M1507,4 the minimum air ONE AN®TWO-FAMILY DWELLINGSM1507ALoc. exhaust rates.Local exhaust systems shall MINIMUM REQUIRED LOCAL EXHAUST RATES E I's be designed to have the capacity to exhaustAREA TO BE EXHAUST RATES EXHAUSTED flow rate determined in accordance with Table M1507. • 100 cfm intermittent or 25 cfm co r' Kitchens tr:.- Bathrooms-Toilet Mechanical exhaust ca aci of'S1 f'e;i'; intermittent or 20 cfm continuous3: Rooms a,For SI: I cubic foot per minute=0.0004714 mils• `-` 9 N.. li e°C Fr 1.47 00)z -ifs crrx .tvD , e..); 0 1%9 30/6” --", i 0 el_-.1.4 V ifZi; ii.. F.St;r. 0r i;2015INTERNATION a Manual S Compliance Report Job: lot 16spec Date: May 02,2019 Entire House By: Plan: 1430 foothill builders Project Information For: foothill builders queensbury, ny 12804 Cooling Equipment Design Conditions Outdoor design DB: 85.0°F Sensible gain: 22286 Btuh Entering coil DB: 75.3°F Outdoor design WB: 71.0°F Latent gain: 4625 Btuh Entering coil WB: 62.6°F Indoor design DB: 75.0°F Total gain: 26911 Btuh Indoor RH: 50% Estimated airflow: 1066 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: York Model: TCGD30S41S3+FC35C3XC2+TM8X100C2OMP11 Actual airflow: 960 cfm Sensible capacity:0 Btuh 0% of load Latent capacity: 0 Btuh 0% of load Total capacity: 0 Btuh 0% of load SHR: 0% Heating Equipment Design Conditions Outdoor design DB: -4.0°F Heat loss: 96149 Btuh Entering coil DB: 65.1°F Indoor design DB: 68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: York Model: TM9X080B12MP11 Actual airflow: 960 cfm Output capacity: 76000 Btuh 79% of load Temp. rise: 50 °F Meets are all requirements of ACCA Manual S. 2019-May-02 13:45:51 wrightsoft° Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 ACCA ...cott.langeworthy\Documents\York\lot 16 spec.rup Calc=MJ7 Front Door faces: N i Residential Plans Examiner Review Form Form RPER 1ACCk. for HVAC System Design (Loads, Equipment, Ducts) 15Mar09 queensbury Header Information Contractor: foothill builders REQUIRED ATTACHMENTS ATTACHED Manual J1 Form(and supporting worksheets): Yes 0 No Mechanical license: or MJ1AE Form*(and supporting worksheets): Yes 0 No OEM performance data(heating,cooling,blower): Yes No 0Buildingplan#: 1430 Manual D Friction Rate Worksheet: Yes 0 No 0 Duct distribution sketch: Yes No Home address(Street or Lot#,Block,Subdivision): , Entire House HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature:4 °F Orientation: Front Door faces North Indoor temperature: 68 of North,East,West,South,Northeast,Northwest,Southeast,Southwest Total heat loss: 96149 Btuh Number of bedrooms: 3 Conditioned floor area: 4200 ft2 Summer Design Conditions Number of occupants: 0 Outdoor temperature: 85 °F Indoor temperature: 75 °F Windows RoofGrainsdifference: 27 grub @50% RH Eave overhang depth: 0 ft Sensible heat gain: 24762 Btuh Internal shade:none EaveLatentheatgain: 5139 Btuh Blinds,drapes,etc.esp Depth Window Total heat gain: 29901 Btuh Number of skylights: 0 HVAC EQUIPMENT SELECTION (IRC M1401.3) Heating Equipment Data Cooling Equipment Data Blower Data Equipment tye: Gas furnace Equipment type:Split AC Heating cfm: 960umace,Hea pump,Boiler,etc. Air Conditioner,Heat pump,etc.Cooling cfm: 960 Model: York Model: York Static pressure:0 in H2O TM9X080B12MP11 TCGD30S41S3 Fan's rated external static pressure for design airflow Heating output capacity:.761000 Btuh Total cooling capacity:0 BtuhHeatpumps-capacity at winter design ou door conditions Sensible cooling capacity: 0 Btuh Aux.heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1) Design airflow: 960 cfm Longest supply duct: 0 ft Duct Materials Used Equipment design ESP: 0 in H2O Longest return duct: 0 ft Trunk duct: Total device pressure losses: 0 in H2O Total effective length(TEL): 0 ft Available static pressure(ASP): 0 in H2O Friction rate: 0 in/100ft Branch duct: Sheet metal Friction Rate=ASP+(TELx 100) I declare the load calculation,equipment,equipment selection and duct design were rigorously performed based on the building plan listed above. I understand the claims made on these forms will be subject to review and verification. Contractor's printed name: Contractor's signature: Date: Reserved for County,Town Municipality orAuthority having jurisdiction use. Home qualifies for MJ1AE Form based on Abridged Edition Checklist 1 wrightsoft® Right-Suite®Universal 2017 17.0.16 RSU25116 Project Summary, Job: lot 16 specSummaryDate: May 02,2019EntireHouseBy: foothill builders Plan: 1430 Pro'ect Information For: foothill builders queensbury, ny 12804 Notes: Desi• n Information Weather: Glens Falls AP, NY, US Winter Design Conditions Summer Design Conditions Outside db 4 °F Outside db 85 °F Inside db 68 °F Inside db 75 °F Design TD 72 °F Design TD 10 °F Daily range M Relative humidity 50 % Moisture difference 27 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 90453 Btuh Structure 21247 Btuh Ducts 5697 Btuh Ducts 1039 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none) Humidification 0 Btuh Bloer( none) 0 Btuh Piping 0 Btuh Equipment load 96149 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 20058 Btuh Method Simplified Latent Cooling Equipment Load SizingConstructionqualityAverage Fireplaces 1 (Average) Structure 4625 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling none) Area(ftZ) 4200 4200 Equipment latent load 4625 Btuh Volume(ft') 37800 37800 Air changes/hour 0.90 0.40 Equipment total load 24683 Btuh Equiv.AVF (cfm) 567 252 Req. total capacity at 0.70 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary Make York Make York Trade YORK Trade LATITUDE Model TM9X080B12MP11 Cond TCGD30S41S3 AHRI ref 2008691 Coil FC35C3XC2+TM8X100C2OMP11 AHRI ref 3740180 Efficiency 95.5 AFUE Efficiency 12.0 EER, 14 SEER Heating input 80000 Btuh Sensible cooling 20160 Btuh Heating output 76000 Btuh Latent cooling 8640 Btuh Temperature rise 72 °F Total cooling 28800 Btuh Actual air flow 960 cfm Actual air flow 960 cfm Air flow factor 0.010 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.83 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. 2019-May-02 13:45:51 4CCP. wrightsoftW Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 cott.langeworthy\Documents\York\lot 16 spec.rup Cale=MJ7 Front Door faces: N Right-J®Worksheet Job: lot 16 spec Entire House Date: May 02,2019 foothill builders Plan: 1430 MANUAL J:7th Ed. 1 Name of room Entire House Room1 Room2 Room32Lengthofexposedwall570.0 ft 190.0 ft 190.0 ft 35.0 ft3Roomdimensions1.0 x 1400 ft 1.0 x 1400 ft 1.0 x 220.0 ft4CeilingsCondit.Option 9.0 ft d 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh)EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg 5 Gross a 12E3 5.4 1.0 5130 *""* **** 1710 **** "*** 1710 *""" ****315 **** ****Exposed b 0 0 111111 **** ****IIIIII **** ****IIIIII **** ****111111 **** **** walls and c 0 0 111111 **** ****111111 **** ****111111 **** ****IIIIII **** **** partitions d 0 0 IIIIII **** ****IIIIII **** ****huh **** ****Hill **** **** e 0 0 IIIIII **** ****IIIIII **** ****min **** ****IIIIII **** **** f 0 0 IIIIII **** ****win **** ****IIIIII **** ****IIIIII **** **** 6 Windows and a 3A0 39.7 ** 205 8133 **"" 55 2182 *""* 0 0 **** 30 1190 *""" glass doors b 0 "" 0 0 **** 0 0 *"** 0 0 "*** 0 0 **** Heating c 0 "" 0 0 **** 0 0 **** 0 0 **** 0 0 **** d 0 ** 0 0 "*** 0 0 **"" 0 0 **** 0 0 **** e 0 *" 0 0 ""** 0 0 **** 0 0 "*"* 0 0 "*** f 0 ** 0 0 *""* 0 0 *"** 0 0 ""*" 0 0 "*** 7 Windows and North 19.0 60 "***1140 0 **** 0 0 **** 0 30 ****570 glass doors NE/NW 0 0 **** 0 0 **** 0 0 ""** 0 0 "*** 0CoolingE/W 68.0 115 ""** 7820 55 **** 3740 0 "*** 0 0 **** 0 SE/SW 0 0 **** 0 0 "*** 0 0 **** 0 0 **** 0South34.0 30 **** 1020 0 ""** 0 0 "*** 0 0 ""** 0Horz00 **** 0 0 **** 0 0 **** 0 0 **** 0 8 Other doors a 10D0 33.1 6.3 63 2087 394 0 0 0 0 0 0 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 4862 26255 4959 1655 8937 1688 1710 9234 1744 285 1539 291 exposed b 0 0 null 0 0 111111 0 0 111111 walls and c 0 0 will 0 0 IIIIII 0 0 partitions d 0 0 111111 0 00 mill 0 0 111111 0 0 111111 0 0 0 0 IIIIII Q 0 IIIIII 0 0 e 0 0 IIIIII 0 0 111111 0 0 IIIIII 0 0 111111 f 0 0 IIIIII 0 0 null 0 0 IIIIII 0 0 0 0 HIM 0 0 10 Ceilings a 16G0 2.4 1.1 2800 6653 3142 0 0 0 1400 3326 1571 220 523 247 b 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 C 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 111111 0 0 d 0 0 111111 0 0 hull 0 0 rim,III 0 0 111111 0 0 e 0 0 111111 0 0 IIIIII 0 0 111111 0 0 111111 f 0 0 will 0 I) 1111110 0 0 0 IIIIII 0 0 IIIIII 0 0 11 Floors a 1910 1.7 0 1400 2419 0 1400 2419 0 0 0 0 0 0 0 Note:room b 0 0 IIIIII 0 0 IIIIII 0 0 mil l 0 0 111111 0 0 perimeter c 0 0 null 0 0 ulln is displ.d 0 0 111111 0 0 min0 0 111111 0 0 lulu 0 0 0 0 111111 0 0 111111 0 0 for slab e 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 floors) f 0 0 111111 0 0 111111 0 0 IIIIII 0 0 111111 0 0 12 Infiltration a 168 10.3 268 44906 2772 55 9216 569 0 0 0 30 5027 310Ventilation00000000 13 Subtotal loss=6+8..+11+12 90453 **** **** 22754 **** **** 12560 **** **** 8279 ****Less external heating 0 "*** **** 0 **** **** 0 **"" **** Q **** Less transfer 0 """" **** 0 **** **** 0 **"" **** 0 *"** Heating redistribution Q **** **** Q **** **** 0 "*** **** 0 **** 14 Duct loss 6% 5697 **** 6% 1433 **** 6% 791 **** 6% 521 **** 15 Total loss=13+14 96149 **** **** 24187 **** **** 13351 **** **** 8800 **** 16 Int.gains: People @ 300 0 """* 0 0 **** 0 0 **** 0 0 ""** 0 Appl. @ 1200 0 "*** 0 0 "*** 0 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8..+12+16 21247 "*** **** 5997 **** **** 3315 **** **** 1418 Less external cooling 0 **** **** 0 **** **** 0 ***" **** 0 Less transfer 0 **** **** 0 **** **** 0 **** **** 0 Cooling redistribution 0 **** **** 0 **** **** 0 "*"" **** 0 18 Duct gain 5% **** 1039 5% ****293 5% *"**162 5% **** 69 19 Total RSH gain=(17+18)*PLF 1.00 **** 22286 1.00 ""** 6290 1.00 *"** 3477 1.00 *""" 148720Airrequired(cfm) 960 960 241 271 133 150 88 64 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. wrightsOft" 2019-May-02 13:45:51Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1cott.langeworthy\Documents\York\lot 16 spec.rup Calc=MJ7 Front Door faces: N Right-J®Worksheet Job: lot 16 spec Entire House Date: May 02,2019 foothill builders Plan: 1430 MANUAL J:7th Ed. 1 Name of room Room4 Room5 Room6 Room82Lengthofexposedwall0ft9.0 ft 0 ft 11.0 ft3Roomdimensions1.0 x 52.0 ft 6.0 x 9.0 ft 5.0 x 10.0 ft 11.0 x 11.0 ft4CeilingsCondit.Option 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh)EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg 5 Gross a 12E3 5.4 1.0 0 **** **** 81 **** **** 0 **** **** 99 **** *,**Exposed b 0 0 mill **** ****hull **** ****111111 **** ****111111 **** **** walls and c 0 0 111111 **** ****111111 **** ****111111 **** ****111111 **** **** partitions d 0 0 1H111 **** ****111111 **** ****111111 **** ****111111 **** **** e 0 0 111111 **** ****111111 **** ****111111 **** ****HMI **** **** f 0 0 III 111 **** ****111111 **** ****111111 **** ****111111 **** **** 6 Windows and a 3A0 39.7 ** 0 0 **** 15 595 **** 0 0 **** 15 595 **** glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** d 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** f 0 ** 0 0 **** 0 0 **** 0 0 '*** 0 0 **** 7 Windows and North 19.0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0CoolingE/W 68.0 0 **** 0 15 **** 1020 0 **** 0 15 **** 1020 SE/SW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0South34.0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Horz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 8 Other doors a 10D0 33.1 6.3 0 0 0 0 0 0 0 0 0 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 0 0 0 66 356 67 0 0 0 84 454 86 exposed b 0 0 will 0 0 111111 0 0 111111 walls and c 0 0 willwill 0 0 111111 0 0 partitions d 0 0 111111 00 00 111111 0 0 111111 0 0 111111 0 0 0 0 IIIIII 0 0 111111 0 0 e 0 0 111111 0 0 111111 0 0 111111 0 0 111111 f 0 0 111111 0 0 111111 0 0 111111 0 0 0 0 IIIIII 0 0 10 Ceilings a 16G0 2.4 1.1 52 124 58 54 128 61 50 119 56 121 287 136 b 0 0 null 0 0 111111 0 0 111111 0 0 111111 0 0 c 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 d 0 0 111111 0 0 mill 0 0 111111 0 0 111111 0 0 e 0 0 111111 0 0 1m m i l l 0 0 111111 0 0 111111 f 0 0 mill 0 0 1111110 0 0 0 IIIIII 0 0 111111 0 0 11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0Note:room b 0 0 lull 0 0 111111 0 0 111111 0 0 111111 0 0 perimeter c 0 0 mill 0 0 minisdispl.d 0 0 hill 0 0 nun 0 0 n ull 0 0 111111 0 0 0 0 111111 0 0 111111 0 0 for slab e 0 0 111111 0 0 IIIIII 0 0 illlll 0 0 111111 0 0 floors) f 0 0 min 0 0 111111 0 0 111111 0 0 IIIIII 0 0 12 Infiltration a 168 10.3 0 0 0 15 2513 155 0 0 0 15 2513 155 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 124 **** **** 3593 **** **** 119 **** **** 3850 ****Less external heating p **** **** p **** **** p **** **** 0 **** Less transfer 0 **** **** 0 **** **** 0 **** **** 0 **** Heating redistribution 0 **** **** 0 **** ***• 0 **** **** 0 **** 14 Duct loss 6% 8 **** 6% 226 **** 6% 7 **** 6% 242 **** 15 Total loss=13+14 131 **** **** 3820 **** ****126 **** **** 4092 **** 16 Int.gains: People @ 300 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Appl. @ 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8..+12+16 58 **** **** 1303 **** **** 56 **** **** 1397 Less external cooling 0 **** **** 0 **** **** 0 **** **** 0 Less transfer p **** **** 0 **** **** 0 **** **** 0 Cooling redistribution 0 **** **** 0 **** **** 0 **** **** 018Ductgain5% "*** 3 5% **** 64 5% **** 3 5% **** 68 19 Total RSH gain=(17+18)*PLF 1.00 **** 61 1.00 **** 1367 1.00 **** 59 1.00 **** 1465 20 Air required(cfm) 1 3 38 59 1 3 41 63 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. wrightSOFt Right-Suite®Universal 2017 17.0.16 RSU25116 2019-May-02 13:45:51 ACC Page 2cott.langeworthy\DocumentsWork\lot 16 spec.rup Calc=MJ7 Front Door faces: N Ri ht-J®Work iheet Job: lot 16 spec Entire House Date: May 02,2019 foothill builders•Plan: 1430 MANUAL J:7th Ed. 1 Name of room Room9 Room10 Room11 Room12 2 Length of exposed wall 4.0 ft 10.0 ft 21.0 ft 8.0 ft 3 Room dimensions 4.0 x 4.0 ft 4.0 x 6.0 ft 12.0 x 12.0 ft 10.0 x 4.0 ft 4 Ceilings Condit.Option 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft') Htg Clg 5 Gross a 12E3 5.4 1.0 36 **** **** 90 **** ****189 **** **** 72 ***" **** Exposed b 0 0 111111 **** ****IIIIII **** ****111111 **** ****111111 **** **** walls and c 0 0 111111 **** ****Him **** ****111111 **** ****Mill **** **** partitions d 0 0 111111 **** ****IIIIII **** ****IIIIII **** ****min **** **** e 0 0 IIIIII **** ****mill **** ****Him **** ****111111 **** **** f 0 0 111111 **** ****IIIIII **** ****min **** ****111111 **** **** 6 Windows and a 3A0 39.7 ** 0 0 **** 0 0 **'* 30 1190 **** 0 0 **** glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** d 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** f 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** 7 Windows and North 19.0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Cooling E/W 68.0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 SE/SW 0 0 *'** 0 0 **** 0 0 **** 0 0 **** 0 South 34.0 0 **** 0 0 **** 0 30 **** 1020 0 **** 0 Horz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 8 Other doors a 10D0 33.1 6.3 0 0 0 0 0 0 0 0 0 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 36 194 37 90 486 92 159 859 162 72 389 73 exposed b 0 0 IIIIII 0 0 mill 0 0 111111 walls and c 0 0 111111 0 0 111111 0 0 partitions d 0 0 will 00 0 IIIIII 0 0 111111 0 0 111111 0 0 0 0 nnn 0 0 111111 0 0 e 0 0 IIIIII 0 0 111111 0 0 111111 0 0 111111 0 0 f 0 0 IIIIII 0 0 111111 0 0 111111 0 0 IIIIII 0 0 10 Ceilings a 16G0 2.4 1.1 16 38 18 24 57 27 144 342 162 40 95 45 b 0 0 111111 0 0 Him 0 0 111111 0 0 111111 0 0 c 0 0 HIM 0 0 IIIIII 0 0 111111 0 0 111111 0 0 d 0 0 IIIIII 0 0 111111 0 0 IIIIII 0 0 111111 0 0 e 0 0 IIIIII 0 0 111111 0 0 111111 0 0 IIIIII 0 0 f 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0 Note:room b 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 perimeter c 0 0 111111 0 0 IIIIII is displ.d 0 0 1111110 0 111111 0 0 111111 0 0 111111 0 0 0 0 111111 0 0 WWII 0 0 for slab e 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 floors) f 0 0 111111 0 0 IIIIII 0 0 111111 0 0 WWII 0 0 12 Infiltration a 168 10.3 0 0 0 0 0 0 30 5027 310 0 0 0 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 232 **** ****543 **** **** 7418 **** ****484 **** Less external heating 0 **** **** 0 **** **** 0 **** **** 0 **** Less transfer 0 **** **** 0 **** **** 0 **** **** 0 **** Heating redistribution 0 **** **** 0 **** **** 0 **** **** 0 **** 14 Duct loss 6%15 **** 6%34 **** 6% 467 **** 6%30 **** 15 Total loss=13+14 247 **** ****577 **** **** 7885 **** ****514 **** 16 Int.gains: People @ 300 0 **** 0 0 *'** 0 0 **** 0 0 **** 0 Appl. @ 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8..+12+16 55 **** ****119 **** **** 1654 **** **** 118 Less external cooling 0 **** **** 0 **** **** 0 **** **** 0 Less transfer 0 **** **** 0 **** **** 0 **** **** 0 Cooling redistribution 0 **** **** 0 **** **** 0 **** **** 0 18 Duct gain 5% **** 3 5% **** 6 5% **** 81 5% **** 6 19 Total RSH gain=(17+18)*PLF 1.00 **** 57 1.00 ****125 1.00 **** 1735 1.00 ****124 20 Air required(cfm) 2 2 6 5 79 75 5 5 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. wrightsOft® 2019-May-02 13:45:51Right-Suite®Universal 2017 17.0.16 RSU25116 Page 34CCN ...cott.langeworthy\Documents\York\lot 16 spec.rup Calc=MJ7 Front Door faces: N Rig ht-J®Worksheet Job: lot 16 spec Entire House Date: May 02,2019 foothill builders Plan: 1430 MANUAL J:7th Ed. 1 Name of room Room13 Room14 2 Length of exposed wall 13.0 ft 79.0 ft 3 Room dimensions 7.0 x 6.0 ft 1.0 x 637.0 ft 4 Ceilings Condit.Option 9.0 ft heat/cool 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Area EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg Htg Clg Htg Clg 5 Gross a 12E3 5.4 1.0 117 **** ****711 **** **** Exposed b 0 0 Will **** ****i i i i i i **** **** walls and c 0 0 111111 **** ****111111 **** **** partitions d 0 0 111111 **** ****win **** **** e 0 0 111111 **** ****rum **** **** f 0 0 111111 **** ****Him **** **** 6 Windows and a 3A0 39.7 ** 0 0 **** 60 2380 **** glass doors b 0 ** 0 0 **** 0 0 **** Heating c 0 ** 0 0 **** 0 0 **** d 0 ** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** f 0 ** 0 0 **** 0 0 **** 7 Windows and North 19.0 0 **** 0 30 ****570 glass doors NE/NW 0 0 **** 0 0 **** 0 Cooling E/W 68.0 0 **** 0 30 **** 2040 SE/SW 0 0 **** 0 0 **** 0 South 34.0 0 **** 0 0 **** 0 Horz 0 0 **** 0 0 **** 0 8 Other doors a 10D0 33.1 6.3 0 0 0 63 2087 394 b 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 117 632 119 588 3175 600 exposed b 0 0 111111 0 0 111111 0 0 walls and c 0 0 nun 0 0 111111 0 0 partitions d 0 0 1 1 1 111 0 0 111111 0 0 e 0 0 111111 0 0 win 0 0 f 0 0 111111 0 0 111111 0 0 10 Ceilings a 16G0 2.4 1.1 42 100 47 637 1514 715 b 0 0 trim 0 0 111111 0 0 c 0 0 111111 0 0 111111 0 0 d 0 0 111111 0 0 min 0 0 e 0 0 111111 0 0 111111 0 0 f 0 0 111111 0 0 min 0 0 11 Floors a 1910 1.7 0 0 0 0 0 0 0 Note:room b 0 0 111111 0 0 111111 0 0 perimeter c 0 0 111111 0 0 111111 0 0 is displ.d 0 0 111111 0 0 111111 0 0 for slab e 0 0 will 0 0 111111 0 0 floors) f 0 0 111111 0 0 111111 0 0 12 Infiltration a 168 10.3 0 0 0 123 20610 1272 Ventilation 0 0 0 0 13 Subtotal loss=6+8..+11+12 732 **** **** 29766 **** **** Less external heating 0 **** **** 0 **** '*** Less transfer 0 **** **** 0 **** **** Heating redistribution 0 **** **** 0 **** **** 14 Duct loss 6%46 **** 6% 1875 **** 15 Total loss= 13+14 778 **** **** 31640 **** **** 16 Int.gains: People @ 300 0 **** 0 0 **** 0 Appl. @ 1200 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8..+12+16 166 **** **** 5591 **** **** Less external cooling 0 **** **** 0 **** **** Less transfer 0 **** **** 0 **** **** Cooling redistribution 0 **** **** 0 **** **** 18 Duct gain 5% **** 8 5% ****273 19 Total RSH gain=(17+18)*PLF 1.00 ****175 1.00 **** 5864 20 Air required(cfm) 8 8 316 253 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. 2019-May-02 13:45:51wrightsoft® Right-Suite®Universal 2017 17.0.16 RSU25116 Page 4 ACC ...cott.langeworthy\Documents\York\lot 16 spec.rup Calc=MJ7 Front Door faces: N NORTH EASTBUILDING PERFORMANCE ADVISORS Serving the Capital District, Saratoga and Adirondack Regions March 31, 2020 7 Rocky Ridge, Warrensburg, NY 12885 Foothill Builders LLC 9 Mountainside Drive Queensbury, NY 12804 RE: Blower Door Test for NYS Building Code, Mr. Joseph Leuci: After inspection of the New 1 Story Home at 55 John Clendon Road, Queensbury, New York and completion of a Blower Door Test consistent with the practice of depressurization to 50 Pascal in a winter condition with the exterior windows and doors shut and the interior doors to all the rooms open, my observations are as follows: This home tested passed the current New York State Building Code for Air Changes per Hour @ 50 Pascal of less than or equal to 3 ACH/50 (for Homes permitted after stNovember1, 2016). The tested number is 2.878 ACH/50 Pascal. The total volume of conditioned space at 55 John Clendon Road is 25332 cubic feet taking into consideration all conditioned space in the home. The cubic feet per minute @ 50 Pascal was 1215 CFM/50. The height correction factor for New York State is 19 for a one story building, as such the tested home @ 55 John Clendon Road, has the natural rate of air exchange of 0.15146 air changes per hour/natural or 64 cfm natural air infiltration credit based on the blower door test. In the latest (2013) version of ASHRAE 62.2, high-performance homes need to be ventilated at 7.5 cfm per bedroom + 1, plus 3 cfm per 100 square feet of living space. That means for 3+1 bedrooms it would need 1437 sq ft/100 times 3 cfm= 43 cfm + 30 cfm or 74 cfm total for a deficit of about 10 cfm. It would also be advantageous to use the bathroom and kitchen fans to help control humidity and set or run a fan or HRV in the heating season to improve indoor air quality and make up for the deficit. My credentials are as follows: BPI Certified Building Analyst BPI Certified Envelope Specialist BPI Certified Heating Professional If you have any questions regarding my findings please feel free to contact me. Sincerely, Jack Towne 1.888.472.2774 7 Rocky Ridge Road 4A Vatrano Drive Warrensburg, NY 12885 Albany, NY 12205 Phone (518)623.7016 Phone (518)350.2941 Fax (518)623.7015 Fax (518)694.0102