RC-0352-2019TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518) 761-8201
Yry'
u
G"
4
Community Development - Building & Codes (518) 761-8256
BUILDING PERMIT
Permit Number: RC-03 52-2019
Tax Map No: 295.15-2-13
Permission is hereby granted to: FOOTHILLS BUILDERS, LLC
For property located at:55 JOHN CLENDON RD
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Type of Construction
Owner Name: John Clendon Hidden Estates LL Single Family-New 1501000.00
Owner Address: 9 Mountainside DR Total Value 1501000.00
Queensbury,NY 12804
Contractor or Builder's Name/Address Electrical Inspection Agency
FOOTHILLS BUILDERS,LLC
9 Mountainside DR
Queensbury,NY 12804
Plans&Specifications
Single Family Dwelling w/gas FP 1437 s.f.
Garage 484 s.f.
Lot 16
731.10 PERMIT FEE PAID -THIS PERMIT EXPIRES: Wednesday, June 10, 2020
If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town of Queensbury; Tuesday, June 11, 2019
SIGNED BY:for the Town of Queensbury.
Director of Building&Code Enforcement
Office Use Only
PRINCIPLE STRUCTURE PERMIT
Permit#:
4
APPLICATION Permit Fee:$ r5,.I O
742 Bay Road Queensbury, NV 12804 Rec. Fee:$ N114
P 518-761-8256 Invoice#: 151 1p
Project Location: ' 30 14 iJ C L(N00 pD
Tax Map #: 7-9 S , / S- - - 13 Subdivision Name: O RP r Pi/Apt-0
TOWN BD RESOLUTION 86-2013 $850 recreation fee for new dwellingunlis single du 5 f j family. p; <:;s-two-family:
muitipiefamily. apartments condominiums townhouses,and car manufactured i modular homes but not mobile
homes. This is in addition to the permit fee(s).
CONTACT INFORMATION:
Applicant:
Name(s): E0 oTHI OA )3uit_DERS (ToC Liu<--i
Mailing Address, CIS/Z: LI m b rid TA I tu5 c O b R.i vi= tut s8,4Izy Pk( i2.ra`1
Cell Ph.: t ( si ) -7'1 - t11 33 Land Lire: i (St1 ) iRra-3sZo £CEzA-)
Email: Foo Ttili-LSaurL-Degst.ryg GmAJLec0rv\
Primary Owner(s):
Name(s): StckME As APPt-Ic.flri7
Mailing Address, CISIZ:
y \
Cell Ph.:L „Land Line:
i,/ r ____...„ y
eti/Email:
Contractor(s): 3o7/]2019
Name(s): S Arne- AS A PpL CAN i
TOBU 0,
QUaEEN RbsBU
Mailing Address, CISIZ: CCB€
r,/
Cell Ph.:Land Line: (
Email:
Architect(s)/Engineer(s):
Name(s): bRt.) yA1-J , PE CYiS1t?tJ r£r1L 1NE-e1~1ic-- )
Mailing Address, CISIZ: Soo G-L NJ 5 cLu re 5(0 G-Lt s FALO N '-f )2 O I
Cell Ph.: _._...( Land Line: I ( 5'1 ? ) 79 2 - 12leti
Email: 1)Rlii J trISlotJErvG- . emA1ir.
Contact Person for Building & Code Compliance: 3c6 Lt;V'C.1
Cell Ph.: 1 (S-t ' ) 111- 1133 Land Line: i ( I S ) 1 q -3SZ.6 (46-L0
Email: Eoo T tkit-LSGuI Li)Ct2-SjJ`1( G MAII--- C..o reN
Tr,O Ruildine R rndp FnfnrrQrnent Princinle Struriure Rrvi;nd Mardi 7QIR
PROJECT INFORMATION:
TYPE: Commercial V Residential
WORK CLASS:
Single-Family Two-Family Multi-Family(#of
Townhouse Business Office Retail Hotel/Motel
Industrial/Warehouse Garage(#ofcars ) Other(describe
STRUCTURE SQUARE FOOTAGE: GARAGE SQUARE FOOTAGE:
1floor. (J3-7 1sT floor: La LI
2" floor: " 7 2d floor:
srd floor: L/c L/Total square feet:
Basement(habitable space):
Total square feet: 1 L/3-
ADDITIONAL PROJECT INFORMATION:
1. Estimated Cost of Construction:$I S O CrO 0
2. Proposed use of the building: ff5 )b i to
3. If Commercial or Industrial,indicate the name of the business:
4. Source of Heat(circle one): ig Oil Propane Solar Other:
Fireplaces need a separate Fuel Burning Appliances&Chimney Application,one per appliance)
5. Are there any structures not shown on the plot plan? YES N Explain:
5. Are there any easements on the property? YES
7, SITE INFORMATION:
a.What is the dimensions or acreage of the parcel? 0 , 8
b. Is this a corner lot? YES
c.Will the grade be changed as a result of the const '.a_ YES
d.What is the water source? PUBLIC PRIVAT WELL
e. Is the parcel on SEWER or a PRIVATE SEPTIC system? PIZ I v A 1C
TOO Ruil din¢R(-Atli.FnfArfPR1ArN
Prinrinia Sfnirfnri RPvicnri Mardi 7l7R
DECLARATION:
I. I acknowledge that no construction shall commence priorto issuance of a valid building
perm and work will be completed within a 12 month period.
2. If the work is not completed by the 1 year expiration date the permit may be renewed,
subject to fees and department approve 1.
3. I certify that the application, plans and supporting materials are a t rue and complete statement
and/or description of the work proposed, that all work will be performed in accordance with the
NYS Building Codes, local buikling laws and ordinances, and in conformance with local zoning
regulations.
4, I acknowledge that prior to occupying the facilities proposed I,or my agents, will obtain a
certificate of occupancy.
5. I understand that lance are required to provide an as-built survey by a licensed land surveyor of
all newly constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINT NAME: -ToS €P )4 Le
SIGNATURE: Off\A 31111" BATE;
TOO Building&Code Enforcement Prinrinia StnErta,ro RavicPri March 7M
Office Use Only
FUEL BURNING APPLIANCE & Permit#:_ 0--(..._—0 b2._•-2-0 11CHIMNEYAPPLICATION•-..., i i,.= Permit Fee:$t4;;:e0 -',1.'•,,
Invoice it
74, 6d, Road. Queensbu , N 2804 P.
51.; 761-8256
Project Location: SS 3-014) CL6-1'-'"'s)
Tax Map ID: 2-1 S-- - I S-- 2- - IS
Room of Install: G-g-trwr agnt, Planned Install Date: -7) ) V iz,0 fq
ONE APPLICATI ON PER APPLIANCE**
CONTACT INFORMATION:
Applicant:
Name(s): FooTH i L-Ls Olik it_bEg. LL.c (:RE Leu C
Mailing Address, C/S/Z: 61 1110LN,•)-ifiriv4./D6 De- Que e--,p•i-5 go P-1 N j i l_g O 1
Cell Ph.: I (c-ig ) 19 1- (6133 15te4 Line: f ( Cig ) -716 -3S-2.0 ct,-,-u-)
Email: Foo-niiiLs 60,103e-0 NI 1 6:), C-In ti 1 L,co ryk
Primary Owner(s):
Name(s): SA revE— OS AP f L 1 ( (V r47
Mailing Address, C/SIZ:
Cell Ph.: ( Land Line: (
Email:
Installer/Builder:
Name(s): Sta ro
Mailing Address, C/S/Z:
Cell Ph.: ( Land Line: (
Email:
Contact Person for Building & Code Compliance: T3 E I-E Lk c I
Cell Ph.: I (c-(r ) -rt I - 1133 band Line: ii 5"I S' ) 11 6 - 3 s-2-0 (c_e1-1--)
Email: -g..9-6--F-1444;4;s3=4v,„- Foo-FH 11-“etAiLDE Ks wte C-IY‘Mb. L-0 ty>,
Town of Otx-ensoury Budd ri .,,'-ii,Enforcement
FUEL BURNING APPLIANCE INFORMATION:
TYPE OF DEVICE:
Stove X Fireplace Insert Fireplace
t,\ i i i€ m°Li1,3171 N Shcb IJvb 3(0 P3oN IA HOC Dlr -AXE
Fuel Fired Equipment(Garage Only,13"clearance per 1MC 304.3)
Fireplace, factory built**
Manufacturer's Name: Model#:
SOURCE OF HEAT:
Wood Coal Pellet Gas
CHIMNEY INFORMATION:
Masonry:
block brick stone
Flue:
tie st) /size,in inches
Material*:
double-wall triple-aura!!_insulated
Manufacturer's r-i r r-i eat_ Model#:
ADDITIONAL INFORMATION:
L Two inspections are required. A rough-in inspection,prior to installation and a final inspection,after
installation.
2 Manufacturer's installation manual must be available at the time of inspection.
3 Masonry fireplaces &chimneys require plans to be submitted.
4 Twenty-four (24)hour notification is required for inspections.
Declaration:Constructiontnstallation must conform to NYS Fire Prevention&Building Code and/or manufacturer
requirements,The applicant or owner agreesto comply with all applicable laws,ordinances,regulations and all
conditions that are part ofthese requirements and also will allow the inspector to enter the premises to perform the
required inspections.
I have read and agree to the above:
PRINT NAME: .1303€PH L£u
SIGNATURE:ATE: S 'Jo)'
Fuel Burning Appliance&Chimney Application
SEPTIC DISPOSAL PERMIT APPLICATION use c_.,,1
7 Bay Road,Qu: ensbury.\1- i-N0-t
P518-76.-,:'56 Perm: (LC -bb`DZ' 1
Tax Map ID#: v`Zf
Project Location: 3:Eolce a i
Primary Owner(s) 1 TO c T I-t i .-t S Av-i L b e Q S 1_L-C (ac C Levi e i)
Mailing Address
i GLA-tsiTA WSIDE' R QU-6 uSBc0?-.1 I` 11 12goli
Phone & Email ie) l`t!-t`f33 7cf._. 52 RNyG A)LrGOrtCoi(EtLZ5f3 L
installer/Builder I Some- Rs 119Pc.i(R.nfr
Mailing Address
Phone & Email
Engineer
i,
Mailing Address hol WW1LANi] RD Ike- NSt3i`tits1 AJ1 t210I
Phone& Email 1--
l (s-ii)-19(0-zs--1 S ¶ r•i-I6-f.3( Q yA Noo, tor"
Contact Person for Buikling&Code c raprliara :,
LE c-)
Phc r : (s 1$)i'i 1 ` 19 33
RESIDENCE NFORMATION:
c1 ` `3, 2 0
Year Built # of bedrooms X gallons per bedroom = totaldaily flow Garbage Grinder Yes N
7980 or older installed? {circle one)
1981-091 Spa or Hot Tub Yes N
14g2 Pr-sen
G 3
Installed? {circle one)
i`_-
PARCEL NFORMATION:
Topography K Flat Rolling Steep Slope Slope
Soil Nature Sand Loam Clay _Other
Groundwater ._..__.,. ,_ ' At what depth? / / _.._._.._._
Bedrock/lmperviousmateriai At what depth? N /A
Domestic Water Supply 1" Municipal _Well{if well,water supply from any septic system absorption is It.)
Percolation Test Rate:)-c per minute per inch(test to be completed by licensed engneer/arcttect)
PROPOSED SYSTEM FOR NEW CONSTRUCTION:
Tank size ) 6 0 t ga lions{min.size 1000 ga lions,add 250 ga lions for each garbage cylinder or spa/hot tub
MEIAbsorption field with#2 stone Total length i CO ft.:Each Trench C 6 ft. __ ..-_._—.__
IIIIIIIIIIIII Seepage Pit with#3 stone How many: Size:
Alternative System Bed or other type:
Holding Tank System Total required capacity? tank size of tanks
NOTES:1.Alarm system&associated electrica lwork must be inspected bya Town approved electrical inspection
agency:2,We will no longer allow systems to be covered until such time as an as-built plan is received and approved.
The installed system must match the septic layout on file-no exceptions.
Declaration:Any permit or approval granted which is based upon or is granted in reliance upon any material
representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void
have read the regulations and agree to abide by these and all requirements of theTown ofQueensbury Sanitary Sewage
Disposal Ordinance.
PRINT NAME: i g S Cr W c I DATE:
S 36 I l
SIGNATURE:
1/4-6 \ 34 l
DATE:
ro'in'0c... ,,,., ,E. Code En`orcement
Town of Queensbury David Duell
Highway Superintendent
Highway t`
qt
518-761-8212
Department
742 Bay Road—Queensbury,NY
Mark Benware
12801 Deputy Highway Superintendent
Phone: (518) 761-8211
518-761-8210
Fax: (518) 745-4466
DRIVEWAY PERMIT
DATE: S )36
APPLICANT NAME:f o 6 N ILLS But I W US CSoE LELt
TELEPHONE NO.:1071 l-1933I(St81716- 20
ADDRESS TO BE INSPECTED: C-' Ja Nw C LE:is Dt P
RETURN ADDRESS:9 lY-10\,,,--c.ft,1 D C D B
fl 7_8-6
Applicant must show exact location and width of driveway(s) to be connected to the highway by
placing stakes at the specified location.
The Superintendent of Highways of the Town of Queensbury has reviewed this application. The
following action has been taken:
STEP 1: Preliminary Approval
NEED: Slight swale
Deep swale
Level with the road
Level with the top of the paved wing
Size culvert pipe to be used (if necessary)
12" ( ) 15" ( ) 18" ( ) 24" ( ) 36"
Preliminary inspection completed by: Date:
Approval by Highway Supt: or) Deputy Supt:
Upon completion, please resubmit this approved permit for a final approval.
STEP 2: Final Approval ( ) Rejected
Date:
David Duell, Highway Superintendent Mark Benware, Deputy Highway Superintendent
REScheck rsii
Compliance Certificate
Project Foothills Builders
Energy Code: 2015 IECC
Location: Glens Falls, New York
Construction Type: Single-family
Project Type: New Construction
Conditioned Floor Area: 1,437 ft2 295.15-2-13 RC-0352-2019
Glazing Area 11% Foothills Builders
Climate Zone: 6 (7635 HDD)
Permit Date: 55 John Clendon Rd, Lot 16
Permit Number: SFD w/gas FP 1437 s.f., Gar. 484 s.f.
Construction Site: Owner/Agent: Designer/Contractor:
John Clendon Drive Daniel W Ryan PE
Lot 16 206 Glen Street
Queensbury, NY 12804 Suite 30
Glens Falls, NY 12801
518-792-9264
dryan@dwrpe.com
Compliance: 0.4%Better Than Code Maximum UA: 241 Your UA: 240
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area
Cavity Cont.
Assembly or
R-Value R Value
U-Factor UA
Perimeter
Ceiling 1: Raised or Energy Truss 1,437 42.0 0.0 0.023 33
Wall 1: Wood Frame, 16" o.c. 1,560 21.0 0.0 0.057 78
Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 132 0.290 38
Door 1: Solid 18 0.140 3
Door 2: Solid 20 0.240 5
Door 3: Glass 18 0.290 5
Floor 1: All-Wood Joist/Truss:Over Outside Air 12 30.0 0.0 0.033 0
Basement Wall 1: Solid Concrete or Masonry 1,443 0.0 15.0 0.046 65
Wall height: 7.8'
Depth below grade: 6.8'
Insulation depth: 7.8'
Window 2: Vinyl/Fiberglass Frame:Double Pane 7 0.400 3
Window 3: Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.290 5
Basement Wall 2: Solid Concrete or Masonry 78 0.0 10.0 0.061 5
Wall height: 7.8'
Depth below grade: 6.8'
Insulation depth: 7.8'
Project Title: Foothills Builders Report date: 04/28/19
Data filename: C:\Users\lrobision\Desktop\1430 Rescheck.rck Page 1 of10
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications, and other
calculations submitted with the permit application.The proposed buil ' g has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.4 and to comply with the mandatory require e s listed in the REScheck Inspection Checklist.
clfr%'jb6-
Name-Title Sig t Da
7z,--.1 C;t
4
L ¢ r
Project Title: Foothills Builders Report date: 04/28/19
Data filename: C:\Users\Irobision\Desktop\1430 Rescheck.rck Page 2 of10
REScheck Software Version
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans.Verified Field Verified
Pre-Inspection/Plan Review
Value Value
Complies? Coo ents/A sa mp ions
RetpID
103.1, Construction drawings and Complies
103.2 documentation demonstrate Does Not
PR1]i
energy code compliance for the
Not Observable
building envelope.Thermal
envelope represented on
Not Applicable
construction documents.
103.1, Construction drawings and Complies
103.2, documentation demonstrate Does Not
403.7 energy code compliance for
PR31i lighting and mechanical systems.
Not Observable
Systems serving multiple
Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: Complies
403.7 sized per ACCA Manual S based Btu/hr Btu/hr Does Not
PR212 on loads calculated per ACCA Cooling: Cooling:
Manual.] or other methods
Not Appervable
approved by the code official.
Btu/hr Btu/hr1 Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Foothills Builders Report date: 04/28/19
Data filename: C:\Users\lrobision\Desktop\1430 Rescheck.rck Page 3 of10
Section-
Flans Verified Fieldllf6FoundationinspectionValuevalueerifi Complies3 CczmmentsfAs umpdons
sID
402.1.1 Conditioned basement wall R- R- Complies See the Envelope Assemblies
FO4]1 insulation R-value.Where interior R R_ Does Not table for values.
insulation is used,verification
may need to occur during Not Observable
Insulation Inspection. Not Not Applicable
required in warm-humid locations
in Climate Zone 3.
303,2Conditioned basement wall r j Complies
F05]i insulation installed per El Does Not
Emanufacturer's instructions.le) r ' Not Observable
Not Applicable
402.2.9 Conditioned basement wall ft ft Complies See the Envelope Assemblies
F06]1 insulation depth of burial or Does Not table for values.
distance from top of wall.
Not Observable
Not Applicable
303.2.1 A protective covering is installed # ,wPr f Complies
FO1112 `toprotect exposed exteriors xp Does Not
insulation and extends a j
minimum of 6 in. below grade. 1 Not Observable
a ;.µ, Not Applicable
403 9 . Snow-and ice-melting system Complies
F01212, controls installed.Does Not
j Not Observable
3K Not Applicable
s
v u u.e t6 a kzy.vg
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Report date: 04/28/19ProjectTitle: Foothills Builders
Data filename: C:\Users\Irobision\Desktop\1430 Rescheck.rck Page 4 of10
i
Section
Plans Verified Field lteri#ied .
Framing/Rough-In Inspection- Complies? Comments/Assumptions
et(.ID _
ValueValue
402.1.1, Door U-factor.U- U- Complies See the Envelope Assemblies
402.3.4 Does Not
table for values.
FR1]1
Not Observable ;
Not Applicable
402.1.1, Glazing U-factor(area weighted U U- Complies See the Envelope Assemblies
402.3.1, average). Does Not table for values.
402.3.3, Not Observable
402.3.6,
402.5
ENot Applicable
FR2]1
l
303.1.3 ''U-factors of fenestration products Complies
FR4]1 are determined in accordance Does Not
with the NFRC test procedure or
taken from the default table.
Not Observable
1,1 Not Applicable E
402.4.1.1 ;Air barrier and thermal barrier Complies
FR23]1 installed per manufacturer's Does Not
44)
instructions. ENot Observable
Not Applicable
402.4.3 ;Fenestration that is not site built Complies
FR20]1 is listed and labeled as meeting Does Not
ti
AAMA/WDMA/CSA 101/1.5.2/A440
Not Observable
or has infiltration rates per NFRCi
400 that do not exceed code
Not Applicable
limits.
O24.5 ' ,IC-rated recessed lighting fixtures
1.,' : ElComplies
FR16]2 sealed at housing/interior finish `a Does Not
and labeled to indicate <_2.0 cfm
leakage at 75 Pa.
ENot Observable
Not Applicable
403.2.1 ;Supply and return ducts in attics `' Complies
FR12]1 insulated >= R-8 where duct is ElDoes Not
3 inches in diameter and >_ Not Observable
R-6 where < 3 inches.Supply and
return ducts in other portions of ENot Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3.3.5 ;Building cavities are not used as Complies
FR15]3 'ducts or plenums. Does Not
s ENot Observable
Not Applicable
4t)34 ;HVAC piping conveying fluids ; R- R- Complies
FR17]2 [above 105 °F or chilled fluids Does Not
below 55 °F are insulated to >_R : ID Not ObservableV3.EN ot Applicable
403.4.1 ;Protection of insulation on HVAC Complies
Piping. Does Not
ENot Observable
ENot Applicable
403.5.3 Hot water pipes are insulated to R- R-Complies
FR78]2 .' >_R-3. Does Not
r ENot Observable
ENot Applicable
403,E ,Automatic or gravity dampers are[ -` ` ' Complies
FR1912 ;installed on all outdoor air Does Not
intakes and exhausts.
i ENot Observable I
ENot Applicable ,
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) l
Project Title: Foothills Builders. Report date: 04/28/19
Data filename: C:\Users\Irobison\Desktop\1430 Rescheck.rck Page 5 of10
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Foothills Builders Report date: 04/28/19
Data filename: C:\Users\Irobision\Desktop\1430 Rescheck.rck Page 6 of10
t
Section Plans Verified Field Verified
insulation Inspection Value Value Complies? Comments/Assumptions
Req.113
303,1 ;All installed insulation is labeled Complies
IN1312 or the installed R-values Does Not
provided. Not Observable
j Not Applicable
402.1.1, Floor insulation R-value. R- R- EComplies See the Envelope Assemblies
402.2.6 Wood Wood Does Not table for values.
IN111 Steel Steel Not Observable
s.Not Applicable
303.2, ;Floor insulation installed per 1 Complies
402.2.7 :manufacturer's instructions and Does Not
IN2]1 in substantial contact with the Not Observable
underside of the subfloor, or floor.
framing cavity insulation is•in
Not Applicable
contact with the top side of
sheathing, or continuous
insulation is installed on the
underside of floor framing and
extends from the bottom to the
top of all perimeter floor framing
members.
i- _
402.1.1, Wall insulation R-value. If this is a R- R- EComplies See the Envelope Assemblies
402.2.5, mass wall with at least 1/
2 of the Wood Wood Does Not table for values.
402.2.6 ,wall insulation on the wall Mass Mass Not Observable
IN3]1 ;exterior,the exterior insulation
requirement applies (FR10). ;El Steel ID Steel Not Applicable
303.2 Wall insulation is installed per Complies
IN4]1 manufacturer's instructions. ! ',Does Not
Not Observable
i
x'' Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Foothills Builders Report date: 04/28/19
Data filename: C:\Users\Irobision\Desktop\1430 Rescheck.rck Page 7 of10
ctiOn
plane verified F1s1rt.lPe 'shedF€ l Lne aect[oe , to isi s Complies? Comments/Assn ptions
Req.lf'u
AJaI[t lflue 1 _ ,
402.2.1, '
Ceilinginsulation R-value.
III Wood Wood Doespltes See the Envelope assembliesR-
402.2.2,
Not table for values.
402.2.E
Steel Ell Steel Not
FIl]1 ( Not Applicable
303.1.1.1, :Ceiling insulation installed per Complies
303.2 :manufacturer's instructions. Does Not
FI2]1 Blown insulation marked every
300 ft2.Not Observable
Not Applicable
402.2,3 ;Vented attics with air permeable Complies
fF12212 l insulation include baffle adjacent , Does Not
to soffit and eave vents that i Not Observable£d _5 qextendsoverinsulation.
a Not Applicable
402.2.4 Attic access hatch and door R- R- Complies
Fl3]1 insulation >_R-value of the 10Does Not
adjacent assembly.
Not Observable
Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = Complies
FI17]1 ach in Climate Zones 1-2, and ElDoes Not
3 ach in Climate Zones 3-8.
Not Observable
Not Applicable
403.2.3 ;Duct tightness test result of<=4 cfm/100 cfm/100 Complies
FI4]1 :cfm/100 ft2 across the system or ft2 ft2 Does Not
3 cfm/100 ft2 without air
Not Observablehandler@25Pa. For rough-in
tests,verification may need to Not Applicable
occurduring Framing Inspection.
403.3.2----1 Ducts are pressure tested to cfm/100 cfm/100 Complies
FI27]1 determine air leakage with ft2 ft2 Does Not
either: Rough-in test:Total
leakage measured with a Not Observable
pressure differential of 0.1 inch Not Applicable
w.g.across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g.across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air: handler leakage designated EiComplies
FI24]1 by manufacturer at<=2%of Does Not
design air flow.
Not Observable
Not Applicable
403.1.1 :Programmable thermostats Complies
F19]2 :installed for control of primary Does Not
heating and cooling systems and
s
initially set by manufacturer to Not Observable '.
code specifications. Not Applicable
40 1.2 ',Heat pump thermostat installed Complies
F110]2 ;on heat pumps. e
NoDotsObseNotrvable
Not Applicable
403.5,1 ,Circulating service hot water Complies
F11 j2 systems have automatic or Does Not
accessible manual controls.
Not Observable
Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Foothills Builders Report date: 04/28/19
Data filename: C:\Users\lrobision\Desktop\1430 Rescheck.rck Page 8 of10
ectiore Plans Verified Field Verified
Final inspetf on Provisions Value Value
C mpiies?rsar en sl ssurnPti n
5c keq,IT
4Q3.6.1 ;All mechanical ventilation system Complies
F125]2 i fans not part of tested and listed Does Not
HVAC equipment meet efficacy ON ot Observable
and air flow limits.
Not Applicable
403.2 Hot water boilers supplying heat Complies
FI26]2 through one-ortwo-pipe heating Does Not
systems have outdoor setback Nat Observable
control to lower boiler water
temperature based on outdoor
Not Applicable
temperature.
403 5 1 l Heated; water circulation systems Complies
FF28]2 :have a circulation pump.The Does Not
system return pipe is a dedicated Not Observable
return pipe or a cold water supply
pipe. Gravity and thermos-
Not Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system ,"
pumps start the pump with signal' '
for hot water demand within the ;
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
4Q',5 1 2;Electric heat trace systems 1 Complies
I"i29]2 ;
comply with IEEE 515.1 or UL Does Not
515.Controls automatically
adjust the energy input to the
Not Observable
heat tracing to maintain the
Not Applicable
desired water temperature in the
piping E_
4Q; .5.2. ''Water distribution systems that plies
F130]2 I have recirculation pumps that Does Not
pump water from a heated water Not Observable
supply pipe back to the heated
water source through a cold Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
E of the water entering the cold
water piping to 104°F.
4Q3 5 4 Drain water heat recovery units Complies
Fi31]2 tested in accordance with CSA Does Not
655.1. Potable water-side Not Observable
pressure loss of drain water heat
3 recovery units< 3 psi for
Not Applicable
individual units connected to one '
or two showers. Potable water- s:'
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to j
y
three or more showers.
404.1 _ 75%of lamps in permanent
t,:, ;' Complies
FI6]i ',fixtures or 75%of permanent •^,fiL'
s
Does Not
fixtures have high efficacy lamps Not Observable
Does not apply to low-voltage s
V,gam Not Applicable
lighting.
4Q4,1.1 Fuel gas lighting s stems have Complies
9 9 Y
N
E[23]3 no continuous pilot light. e ' Does Not
i #hay ':.
Not Observable41)f
Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Foothills Builders. Report date: 04/28/19
Data filename: C:\Users\Irobison\Desktop\1430 Rescheck.rck Page 9 of10
Section
Mans Verified Field VerifiedFinalInspectionProvisions
lal Value Complies? Comments/Assumptions
Req.IC3
gi31.3 ;Compliance certificate posted. f r Complies
F1'71
l
Does Not
Not Observable
Not Applicable
303.3 ',Manufacturer manuals for 1
b i , 1 Complies
F118]3 mechanical and water heating Does Not
systems have been provided. E Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Foothills Builders Report date: 04/28/19
Data filename: C:\Users\lrobision\Desktop\1430 Rescheck.rck Page 10 of10
L 'J Sit „G[,, i,ma,Jyy
u4-01 A Ite f -" *e' Yrr b
Above-Grade Wall 21.00
Below-Grade Wall 15.00
Floor 30.00
Ceiling / Roof 42.00
Ductwork (unconditioned spy&cues):
Glass&Door Rating
Window 0.29
Door 0.24
n In la .,.. ..Equipment Efficiency .,
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments
z
1doECM
HEAT RECOVERY VENTILATOR
ll No
ENGINEERING DATA LIFEBRERTH
II
THERMALLY CONDUCTIVE,PATENTED DEFROST
ALUMINUM CORE Recirculating damper defrost system.
The counter-flow heat recovery core transfers heat between the two airstreams.It is
easily removed for cleaning or service. CASE
Twenty gauge prepainted galvanized steel for superior corrosion resistance.Insulated to
MOTORS AND BLOWERS prevent exterior condensation.Drain connections 2-1/2 in.(12 rum)OD.Balancing ports
High efficiency electronic commutate ECM motor,for maximum energy savings.Each are located on door.
airstream has one centrifugal blower,with multiple fanspeed operations driven by one
double shaft motor. ELECTRONICS
The DXPLO2 control included with the unit can be wall mounted in a central location of
FILTERS the home.3 wire 20 gauge(min.)100 ft length(max.).
Washable antimicrobial MERV 6 air filters in exhaust and supply airstreams.
MOUNTING WARRANTY
Four threaded inserts at corners of the cabinet designed to accept the's' hooks and Units carry a lifetime warranty on the HPV core and a 5 year
hanging straps supplied with the unit. replacement parts warranty.
OPTIONAL ACCESSORIES:
Weather Hood TechGritte
99-EAG4 Terminator Wireless 20/40/60
99-185
9-EAG
Fitting Min Timer
99-186
15
99 EAG6 99-TM4 99-DET02 by
99187 99-EAG8 i, 99-TM6
LIFEBREATH CONTROL OPTIONS TIMER OPTIONS
99-DETO1-Lifebreath 20/40/60 Minute Timer
FEATURES 99-DXPLO2 99-BCO2 99-BC03 99-BC04
Initiates high speed Ventilation for 20,40 or 60
minutes.3 wire connection.
5 speed fan operation on each mode
99-DET02
2 speed fan operation(Low/High) V
Wireless Lifebreath 20/40/60 Minute Timer
Continuous low speed fan operation V Initiates high speed Ventilation for 20,40 or 60
minutes.Wirelessly connects to main control for
Humidity control through adjustable Dehumidistat V V V ease of installation.40'approximate range.
Excusive to Lifebreath.
Large digital LCD screen
99-RX02-Wireless Lifebreath Repeater
LED status indicator lights V V V Extends range of 99-DET02 Wireless Timers.Plugs
into 120V power outlet.Wirelessly connects to
Continuous Ventilation main control and 99-DET02.Install at halfway
point between timer and main wall control if timer
Continuous Recirculation is out of range.
20 ON/40 OFF
10 0N/50 OFF I-fill
f
20 ON/40 Recirculation V V V 1 _- _
U(t'c# (0 o f
20/40/60 min.High speed override button 99-DXPLO2 99 BEToz
Compatible with 99-DET02 Wireless Timer V
I
3 wire connection V V V V LIFEBRERTH'
1118 Indoor Air Systems
100ECM(9-11-18) www.lifebreath.com
iv 1 OECM
4,,,
HEAT RECOVERY VENTILATOR r
zlt
PERFORMANCE (HVI CERTIFIED) th.
LIFEBRERTH'111
as
0.1(25) 0.2(50) 0.3(75) 0.4(100) 0.5(125) 0.6(150) ELECTRICAL SPECIFICATIONS i"
IN.W.G.(PA) [
FM(L/s) [FM(L/s) [FM(L/s) CFM(L/s) CFM(Lis) [FM(Lis)
VAC @ 60Hz 120
Net Supply Airflow 161(16) 143(68) 129(61) 114(54) 97(46) 78(37) Watts/Low Speed 40
Gross Supply Airflow 165(18) 147(69) 131(62) 111(55) 102(48) 81(38) Watts/High Speed 115
Gross Exhaust Airflow 229(108) 215(101) 210(99) 203(96) 184(81) 142(67) Amp Rating 1.75
Sensible Effectiveness(ASE)
180 WEIGHT:
@ 64 CFM(30 Us)
32°F(0°C) 78%
160 71 LBS(32 EKG)
Sensible Efficiency(SRE)
32°F(0°C) 11%
140 SHIPPING WEIGHT:
@ 64 CFM(30 Us) E in 73 LES Q33 MG)
u
Sensible Efficiency(SRE)
32°F(0°C) 69% 3 loci
@ 95 GEM(45 Us)
so
GTE::Sensible Efficiency(SRE) a
@ 68 CFM(32 Us)
13°F(-25°C) 64% 60
Front clearance of 25 in.(635 mm)is
o recommended for servicing unit.All ducts
20 use 6 in.(152 mm)round collars.Balancing
e ISO
dampers are located in all air streams.
z,00I, 44104,oI 0.2 0.3 0.4 0.5 0.6
us FIVI 9001 0._. ,
o„,„..,...d, CERTIFIED REGISTERED Static Pressure(in w.g.)
DD f)v EN5ION5
FRONT VIEW SIDE VIEW
O Filter
143/4 in.(375 mm)
ill'
Recirculating
Defrost =1111 rI 1 IDamperA
Removable le\WIIIIII/ •'\ i IlN Blower
Heat 11RecoveryI/
Motor Stale air to outside
Core i O Fresh air from outsiderStaleairfrominside
I Fresh air to insideQ
6ouin.
n(1d52Collammrs) l 33 5/8 in.(854 mm) — ,I o v
R
Date:WARRANTY
Contractor: _ Units carry a lifetime warranty
Tag: on the HRV core and a 5 year
replacement parts warranty.
Project' Oty:Supplier:
Engineer: Quote#: All units conform to CSA and UL standards
If
Control: Submitted By: LIFEBRE/ /Q THI
If Indoor Air Systems
Timer: Timer Qty:
100ECM(9-11-18) www.lifebreath.com
EXHAUST 5 Y 5 a a:.ata.
ig
Iii[
s''' i#:„:4.
TABLE Ni150T•3a3(1EHOUSEMECHANICALVENTILATIONSYSTEMAIRFLOWRATEREQUIREMENT
NUgER OF BEDROOMS
k
1111101311111111111111312111111111 5-7 7
ram
DWELLING
AREA 0-1 Airflow In CFM
r1:!-_,
FLOOR Aeet) 90
square feet} 60 75
30 45
75
105
1,500
60
75
j,,
1,501-3,000 15 95 105
105
120
60 75__ 1205 135
t:`:-` 3,001—4,500 I
90
105
150
6,
501—67,500
75
120 IIIIMIIIIIII
90 105 150 165
6,0>
7,5000000 105 120
135
i.For SI: i square foot=0.0929 m2,1 cubic foot per minute=0.0004719 m3/s.
fill
TABLE M15a7,3.3(2)INTERMITTENT WHOLE-ROUSE MECHANICAL VENTILATION RATE FACTORS,
nl
GMENT
255o% 33%
i v .
RUN-TIME PERCENTAGE INEACH 4-HOUR1 5 1.3
4.
Facto permitted to be determined by interpolation.
it
a.For ventilation system run time values between those given,the factors are,:
r-:,..
q;;;, b.Extrapolation beyond the table is prohibited.
F
i
TABLE M1507,4
the minimum air
ONE AN®TWO-FAMILY DWELLINGSM1507ALoc. exhaust rates.Local exhaust systems shall MINIMUM REQUIRED LOCAL EXHAUST RATES E
I's be designed to have the capacity to exhaustAREA TO BE EXHAUST RATES
EXHAUSTED
flow rate determined in accordance with Table M1507. •
100 cfm intermittent or 25 cfm co
r'
Kitchens
tr:.- Bathrooms-Toilet Mechanical exhaust ca aci of'S1
f'e;i'; intermittent or 20 cfm continuous3: Rooms
a,For SI: I cubic foot per minute=0.0004714 mils• `-`
9
N.. li e°C Fr 1.47 00)z -ifs crrx .tvD , e..); 0
1%9
30/6” --", i 0 el_-.1.4
V
ifZi;
ii..
F.St;r.
0r i;2015INTERNATION
a
Manual S Compliance Report Job: lot 16spec
Date: May 02,2019
Entire House By:
Plan: 1430
foothill builders
Project Information
For: foothill builders
queensbury, ny 12804
Cooling Equipment
Design Conditions
Outdoor design DB: 85.0°F Sensible gain: 22286 Btuh Entering coil DB: 75.3°F
Outdoor design WB: 71.0°F Latent gain: 4625 Btuh Entering coil WB: 62.6°F
Indoor design DB: 75.0°F Total gain: 26911 Btuh
Indoor RH: 50% Estimated airflow: 1066 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split AC
Manufacturer: York Model: TCGD30S41S3+FC35C3XC2+TM8X100C2OMP11
Actual airflow: 960 cfm
Sensible capacity:0 Btuh 0% of load
Latent capacity: 0 Btuh 0% of load
Total capacity: 0 Btuh 0% of load SHR: 0%
Heating Equipment
Design Conditions
Outdoor design DB: -4.0°F Heat loss: 96149 Btuh Entering coil DB: 65.1°F
Indoor design DB: 68.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Gas furnace
Manufacturer: York Model: TM9X080B12MP11
Actual airflow: 960 cfm
Output capacity: 76000 Btuh 79% of load Temp. rise: 50 °F
Meets are all requirements of ACCA Manual S.
2019-May-02 13:45:51
wrightsoft° Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1
ACCA ...cott.langeworthy\Documents\York\lot 16 spec.rup Calc=MJ7 Front Door faces: N
i Residential Plans Examiner Review Form Form
RPER 1ACCk. for HVAC System Design (Loads, Equipment, Ducts) 15Mar09
queensbury
Header Information
Contractor: foothill builders REQUIRED ATTACHMENTS ATTACHED
Manual J1 Form(and supporting worksheets): Yes 0 No
Mechanical license: or MJ1AE Form*(and supporting worksheets): Yes 0 No
OEM performance data(heating,cooling,blower): Yes No 0Buildingplan#: 1430 Manual D Friction Rate Worksheet: Yes 0 No 0
Duct distribution sketch: Yes No
Home address(Street or Lot#,Block,Subdivision): , Entire House
HVAC LOAD CALCULATION (IRC M1401.3)
Design Conditions Building Construction Information
Winter Design Conditions Building
Outdoor temperature:4 °F Orientation: Front Door faces North
Indoor temperature: 68 of North,East,West,South,Northeast,Northwest,Southeast,Southwest
Total heat loss: 96149 Btuh Number of bedrooms: 3
Conditioned floor area: 4200 ft2
Summer Design Conditions Number of occupants: 0
Outdoor temperature: 85 °F
Indoor temperature: 75 °F Windows RoofGrainsdifference: 27 grub @50% RH Eave overhang depth: 0 ft
Sensible heat gain: 24762 Btuh Internal shade:none EaveLatentheatgain: 5139 Btuh Blinds,drapes,etc.esp
Depth Window
Total heat gain: 29901 Btuh Number of skylights: 0
HVAC EQUIPMENT SELECTION (IRC M1401.3)
Heating Equipment Data Cooling Equipment Data Blower Data
Equipment tye: Gas furnace Equipment type:Split AC Heating cfm: 960umace,Hea pump,Boiler,etc. Air Conditioner,Heat pump,etc.Cooling cfm: 960
Model: York Model: York Static pressure:0 in H2O
TM9X080B12MP11 TCGD30S41S3 Fan's rated external static pressure for
design airflow
Heating output capacity:.761000 Btuh Total cooling capacity:0 BtuhHeatpumps-capacity at winter design ou door conditions
Sensible cooling capacity: 0 Btuh
Aux.heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh
HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1)
Design airflow: 960 cfm Longest supply duct: 0 ft Duct Materials Used
Equipment design ESP: 0 in H2O Longest return duct: 0 ft Trunk duct:
Total device pressure losses: 0 in H2O Total effective length(TEL): 0 ft
Available static pressure(ASP): 0 in H2O Friction rate: 0 in/100ft Branch duct: Sheet metal
Friction Rate=ASP+(TELx 100)
I declare the load calculation,equipment,equipment selection and duct design were rigorously performed based on the building
plan listed above. I understand the claims made on these forms will be subject to review and verification.
Contractor's printed name:
Contractor's signature: Date:
Reserved for County,Town Municipality orAuthority having jurisdiction use.
Home qualifies for MJ1AE Form based on Abridged Edition Checklist
1 wrightsoft® Right-Suite®Universal 2017 17.0.16 RSU25116
Project Summary, Job: lot 16 specSummaryDate: May 02,2019EntireHouseBy:
foothill builders Plan: 1430
Pro'ect Information
For: foothill builders
queensbury, ny 12804
Notes:
Desi• n Information
Weather: Glens Falls AP, NY, US
Winter Design Conditions Summer Design Conditions
Outside db 4 °F Outside db 85 °F
Inside db 68 °F Inside db 75 °F
Design TD 72 °F Design TD 10 °F
Daily range M
Relative humidity 50 %
Moisture difference 27 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 90453 Btuh Structure 21247 Btuh
Ducts 5697 Btuh Ducts 1039 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
none)
Humidification 0 Btuh Bloer(
none)
0 Btuh
Piping 0 Btuh
Equipment load 96149 Btuh Use manufacturer's data n
Rate/swing multiplier 0.90
Infiltration Equipment sensible load 20058 Btuh
Method Simplified Latent Cooling Equipment Load SizingConstructionqualityAverage
Fireplaces 1 (Average) Structure 4625 Btuh
Ducts 0 Btuh
Central vent (0 cfm) 0 Btuh
Heating Cooling none)
Area(ftZ) 4200 4200 Equipment latent load 4625 Btuh
Volume(ft') 37800 37800
Air changes/hour 0.90 0.40 Equipment total load 24683 Btuh
Equiv.AVF (cfm) 567 252 Req. total capacity at 0.70 SHR 2.4 ton
Heating Equipment Summary Cooling Equipment Summary
Make York Make York
Trade YORK Trade LATITUDE
Model TM9X080B12MP11 Cond TCGD30S41S3
AHRI ref 2008691 Coil FC35C3XC2+TM8X100C2OMP11
AHRI ref 3740180
Efficiency 95.5 AFUE Efficiency 12.0 EER, 14 SEER
Heating input 80000 Btuh Sensible cooling 20160 Btuh
Heating output 76000 Btuh Latent cooling 8640 Btuh
Temperature rise 72 °F Total cooling 28800 Btuh
Actual air flow 960 cfm Actual air flow 960 cfm
Air flow factor 0.010 cfm/Btuh Air flow factor 0.043 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.83
Calculations approved by ACCA to meet all requirements of Manual J 7th Ed.
2019-May-02 13:45:51
4CCP.
wrightsoftW Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1
cott.langeworthy\Documents\York\lot 16 spec.rup Cale=MJ7 Front Door faces: N
Right-J®Worksheet Job: lot 16 spec
Entire House Date: May 02,2019
foothill builders Plan: 1430
MANUAL J:7th Ed.
1 Name of room Entire House Room1 Room2 Room32Lengthofexposedwall570.0 ft 190.0 ft 190.0 ft 35.0 ft3Roomdimensions1.0 x 1400 ft 1.0 x 1400 ft 1.0 x 220.0 ft4CeilingsCondit.Option 9.0 ft d 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool
TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh)EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg
5 Gross a 12E3 5.4 1.0 5130 *""* **** 1710 **** "*** 1710 *""" ****315 **** ****Exposed b 0 0 111111 **** ****IIIIII **** ****IIIIII **** ****111111 **** ****
walls and c 0 0 111111 **** ****111111 **** ****111111 **** ****IIIIII **** ****
partitions d 0 0 IIIIII **** ****IIIIII **** ****huh **** ****Hill **** ****
e 0 0 IIIIII **** ****IIIIII **** ****min **** ****IIIIII **** ****
f 0 0 IIIIII **** ****win **** ****IIIIII **** ****IIIIII **** ****
6 Windows and a 3A0 39.7 ** 205 8133 **"" 55 2182 *""* 0 0 **** 30 1190 *"""
glass doors b 0 "" 0 0 **** 0 0 *"** 0 0 "*** 0 0 ****
Heating c 0 "" 0 0 **** 0 0 **** 0 0 **** 0 0 ****
d 0 ** 0 0 "*** 0 0 **"" 0 0 **** 0 0 ****
e 0 *" 0 0 ""** 0 0 **** 0 0 "*"* 0 0 "***
f 0 ** 0 0 *""* 0 0 *"** 0 0 ""*" 0 0 "***
7 Windows and North 19.0 60 "***1140 0 **** 0 0 **** 0 30 ****570
glass doors NE/NW 0 0 **** 0 0 **** 0 0 ""** 0 0 "*** 0CoolingE/W 68.0 115 ""** 7820 55 **** 3740 0 "*** 0 0 **** 0
SE/SW 0 0 **** 0 0 "*** 0 0 **** 0 0 **** 0South34.0 30 **** 1020 0 ""** 0 0 "*** 0 0 ""** 0Horz00 **** 0 0 **** 0 0 **** 0 0 **** 0
8 Other doors a 10D0 33.1 6.3 63 2087 394 0 0 0 0 0 0 0 0 0
b 0 0 0 0 0 0 0 0 0 0 0 0 0 0
c 0 0 0 0 0 0 0 0 0 0 0 0 0 0
9 Net a 12E3 5.4 1.0 4862 26255 4959 1655 8937 1688 1710 9234 1744 285 1539 291
exposed b 0 0 null 0 0 111111 0 0 111111
walls and c 0 0 will
0 0 IIIIII 0 0
partitions d 0 0 111111 0 00 mill
0 0 111111 0 0 111111 0 0
0 0 IIIIII Q 0 IIIIII 0 0
e 0 0 IIIIII 0 0 111111 0 0 IIIIII 0 0 111111
f 0 0 IIIIII 0 0 null 0 0 IIIIII
0 0
0 0 HIM 0 0
10 Ceilings a 16G0 2.4 1.1 2800 6653 3142 0 0 0 1400 3326 1571 220 523 247
b 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0
C 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 111111 0 0
d 0 0 111111 0 0 hull 0 0 rim,III 0 0 111111 0 0
e 0 0 111111 0 0 IIIIII 0 0 111111 0 0 111111
f 0 0 will 0 I) 1111110 0
0 0 IIIIII 0 0 IIIIII 0 0
11 Floors a 1910 1.7 0 1400 2419 0 1400 2419 0 0 0 0 0 0 0
Note:room b 0 0 IIIIII 0 0 IIIIII 0 0 mil l 0 0 111111 0 0
perimeter c 0 0 null 0 0 ulln
is displ.d 0 0 111111 0 0 min0 0 111111 0 0 lulu 0 0
0 0 111111 0 0 111111 0 0
for slab e 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0
floors) f 0 0 111111 0 0 111111 0 0 IIIIII 0 0 111111 0 0
12 Infiltration a 168 10.3 268 44906 2772 55 9216 569 0 0 0 30 5027 310Ventilation00000000
13 Subtotal loss=6+8..+11+12 90453 **** **** 22754 **** **** 12560 **** **** 8279 ****Less external heating 0 "*** **** 0 **** **** 0 **"" **** Q ****
Less transfer 0 """" **** 0 **** **** 0 **"" **** 0 *"**
Heating redistribution Q **** **** Q **** **** 0 "*** **** 0 ****
14 Duct loss 6% 5697 **** 6% 1433 **** 6% 791 **** 6% 521 ****
15 Total loss=13+14 96149 **** **** 24187 **** **** 13351 **** **** 8800 ****
16 Int.gains: People @ 300 0 """* 0 0 **** 0 0 **** 0 0 ""** 0
Appl. @ 1200 0 "*** 0 0 "*** 0 0 **** 0 0 **** 0
17 Subtot RSH gain=7+8..+12+16 21247 "*** **** 5997 **** **** 3315 **** **** 1418
Less external cooling 0 **** **** 0 **** **** 0 ***" **** 0
Less transfer 0 **** **** 0 **** **** 0 **** **** 0
Cooling redistribution 0 **** **** 0 **** **** 0 "*"" **** 0
18 Duct gain 5% **** 1039 5% ****293 5% *"**162 5% **** 69
19 Total RSH gain=(17+18)*PLF 1.00 **** 22286 1.00 ""** 6290 1.00 *"** 3477 1.00 *""" 148720Airrequired(cfm) 960 960 241 271 133 150 88 64
Calculations approved by ACCA to meet all requirements of Manual J 7th Ed.
wrightsOft" 2019-May-02 13:45:51Right-Suite®Universal 2017 17.0.16 RSU25116
Page 1cott.langeworthy\Documents\York\lot 16 spec.rup Calc=MJ7 Front Door faces: N
Right-J®Worksheet Job: lot 16 spec
Entire House Date: May 02,2019
foothill builders Plan: 1430
MANUAL J:7th Ed.
1 Name of room Room4 Room5 Room6 Room82Lengthofexposedwall0ft9.0 ft 0 ft 11.0 ft3Roomdimensions1.0 x 52.0 ft 6.0 x 9.0 ft 5.0 x 10.0 ft 11.0 x 11.0 ft4CeilingsCondit.Option 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool
TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh)EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg
5 Gross a 12E3 5.4 1.0 0 **** **** 81 **** **** 0 **** **** 99 **** *,**Exposed b 0 0 mill **** ****hull **** ****111111 **** ****111111 **** ****
walls and c 0 0 111111 **** ****111111 **** ****111111 **** ****111111 **** ****
partitions d 0 0 1H111 **** ****111111 **** ****111111 **** ****111111 **** ****
e 0 0 111111 **** ****111111 **** ****111111 **** ****HMI **** ****
f 0 0 III 111 **** ****111111 **** ****111111 **** ****111111 **** ****
6 Windows and a 3A0 39.7 ** 0 0 **** 15 595 **** 0 0 **** 15 595 ****
glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 ****
Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 ****
d 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 ****
e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 ****
f 0 ** 0 0 **** 0 0 **** 0 0 '*** 0 0 ****
7 Windows and North 19.0 0 **** 0 0 **** 0 0 **** 0 0 **** 0
glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0CoolingE/W 68.0 0 **** 0 15 **** 1020 0 **** 0 15 **** 1020
SE/SW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0South34.0 0 **** 0 0 **** 0 0 **** 0 0 **** 0
Horz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0
8 Other doors a 10D0 33.1 6.3 0 0 0 0 0 0 0 0 0 0 0 0
b 0 0 0 0 0 0 0 0 0 0 0 0 0 0
c 0 0 0 0 0 0 0 0 0 0 0 0 0 0
9 Net a 12E3 5.4 1.0 0 0 0 66 356 67 0 0 0 84 454 86
exposed b 0 0 will 0 0 111111 0 0 111111
walls and c 0 0 willwill
0 0 111111 0 0
partitions d 0 0 111111 00 00 111111
0 0 111111 0 0 111111 0 0
0 0 IIIIII 0 0 111111 0 0
e 0 0 111111 0 0 111111 0 0 111111 0 0 111111
f 0 0 111111 0 0 111111 0 0 111111
0 0
0 0 IIIIII 0 0
10 Ceilings a 16G0 2.4 1.1 52 124 58 54 128 61 50 119 56 121 287 136
b 0 0 null 0 0 111111 0 0 111111 0 0 111111 0 0
c 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0
d 0 0 111111 0 0 mill 0 0 111111 0 0 111111 0 0
e 0 0 111111 0 0 1m m i l l 0 0 111111 0 0 111111
f 0 0 mill 0 0 1111110 0
0 0 IIIIII 0 0 111111 0 0
11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0Note:room b 0 0 lull 0 0 111111 0 0 111111 0 0 111111 0 0
perimeter c 0 0 mill 0 0 minisdispl.d 0 0 hill 0 0 nun
0 0 n ull 0 0 111111 0 0
0 0 111111 0 0 111111 0 0
for slab e 0 0 111111 0 0 IIIIII 0 0 illlll 0 0 111111 0 0
floors) f 0 0 min 0 0 111111 0 0 111111 0 0 IIIIII 0 0
12 Infiltration a 168 10.3 0 0 0 15 2513 155 0 0 0 15 2513 155
Ventilation 0 0 0 0 0 0 0 0
13 Subtotal loss=6+8..+11+12 124 **** **** 3593 **** **** 119 **** **** 3850 ****Less external heating p **** **** p **** **** p **** **** 0 ****
Less transfer 0 **** **** 0 **** **** 0 **** **** 0 ****
Heating redistribution 0 **** **** 0 **** ***• 0 **** **** 0 ****
14 Duct loss 6% 8 **** 6% 226 **** 6% 7 **** 6% 242 ****
15 Total loss=13+14 131 **** **** 3820 **** ****126 **** **** 4092 ****
16 Int.gains: People @ 300 0 **** 0 0 **** 0 0 **** 0 0 **** 0
Appl. @ 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0
17 Subtot RSH gain=7+8..+12+16 58 **** **** 1303 **** **** 56 **** **** 1397
Less external cooling 0 **** **** 0 **** **** 0 **** **** 0
Less transfer p **** **** 0 **** **** 0 **** **** 0
Cooling redistribution 0 **** **** 0 **** **** 0 **** **** 018Ductgain5% "*** 3 5% **** 64 5% **** 3 5% **** 68
19 Total RSH gain=(17+18)*PLF 1.00 **** 61 1.00 **** 1367 1.00 **** 59 1.00 **** 1465
20 Air required(cfm) 1 3 38 59 1 3 41 63
Calculations approved by ACCA to meet all requirements of Manual J 7th Ed.
wrightSOFt Right-Suite®Universal 2017 17.0.16 RSU25116 2019-May-02 13:45:51
ACC Page 2cott.langeworthy\DocumentsWork\lot 16 spec.rup Calc=MJ7 Front Door faces: N
Ri ht-J®Work iheet Job: lot 16 spec
Entire House Date: May 02,2019
foothill builders•Plan: 1430
MANUAL J:7th Ed.
1 Name of room Room9 Room10 Room11 Room12
2 Length of exposed wall 4.0 ft 10.0 ft 21.0 ft 8.0 ft
3 Room dimensions 4.0 x 4.0 ft 4.0 x 6.0 ft 12.0 x 12.0 ft 10.0 x 4.0 ft
4 Ceilings Condit.Option 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool
TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh)
EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft') Htg Clg
5 Gross a 12E3 5.4 1.0 36 **** **** 90 **** ****189 **** **** 72 ***" ****
Exposed b 0 0 111111 **** ****IIIIII **** ****111111 **** ****111111 **** ****
walls and c 0 0 111111 **** ****Him **** ****111111 **** ****Mill **** ****
partitions d 0 0 111111 **** ****IIIIII **** ****IIIIII **** ****min **** ****
e 0 0 IIIIII **** ****mill **** ****Him **** ****111111 **** ****
f 0 0 111111 **** ****IIIIII **** ****min **** ****111111 **** ****
6 Windows and a 3A0 39.7 ** 0 0 **** 0 0 **'* 30 1190 **** 0 0 ****
glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 ****
Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 ****
d 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 ****
e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 ****
f 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 ****
7 Windows and North 19.0 0 **** 0 0 **** 0 0 **** 0 0 **** 0
glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0
Cooling E/W 68.0 0 **** 0 0 **** 0 0 **** 0 0 **** 0
SE/SW 0 0 *'** 0 0 **** 0 0 **** 0 0 **** 0
South 34.0 0 **** 0 0 **** 0 30 **** 1020 0 **** 0
Horz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0
8 Other doors a 10D0 33.1 6.3 0 0 0 0 0 0 0 0 0 0 0 0
b 0 0 0 0 0 0 0 0 0 0 0 0 0 0
c 0 0 0 0 0 0 0 0 0 0 0 0 0 0
9 Net a 12E3 5.4 1.0 36 194 37 90 486 92 159 859 162 72 389 73
exposed b 0 0 IIIIII 0 0 mill 0 0 111111
walls and c 0 0 111111
0 0 111111 0 0
partitions d 0 0 will 00 0 IIIIII
0 0 111111 0 0 111111 0 0
0 0 nnn 0 0 111111 0 0
e 0 0 IIIIII 0 0 111111 0 0 111111 0 0 111111 0 0
f 0 0 IIIIII 0 0 111111 0 0 111111 0 0 IIIIII 0 0
10 Ceilings a 16G0 2.4 1.1 16 38 18 24 57 27 144 342 162 40 95 45
b 0 0 111111 0 0 Him 0 0 111111 0 0 111111 0 0
c 0 0 HIM 0 0 IIIIII 0 0 111111 0 0 111111 0 0
d 0 0 IIIIII 0 0 111111 0 0 IIIIII 0 0 111111 0 0
e 0 0 IIIIII 0 0 111111 0 0 111111 0 0 IIIIII 0 0
f 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0
11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0
Note:room b 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0
perimeter c 0 0 111111 0 0 IIIIII
is displ.d 0 0 1111110 0 111111
0 0 111111 0 0 111111 0 0
0 0 111111 0 0 WWII 0 0
for slab e 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0
floors) f 0 0 111111 0 0 IIIIII 0 0 111111 0 0 WWII 0 0
12 Infiltration a 168 10.3 0 0 0 0 0 0 30 5027 310 0 0 0
Ventilation 0 0 0 0 0 0 0 0
13 Subtotal loss=6+8..+11+12 232 **** ****543 **** **** 7418 **** ****484 ****
Less external heating 0 **** **** 0 **** **** 0 **** **** 0 ****
Less transfer 0 **** **** 0 **** **** 0 **** **** 0 ****
Heating redistribution 0 **** **** 0 **** **** 0 **** **** 0 ****
14 Duct loss 6%15 **** 6%34 **** 6% 467 **** 6%30 ****
15 Total loss=13+14 247 **** ****577 **** **** 7885 **** ****514 ****
16 Int.gains: People @ 300 0 **** 0 0 *'** 0 0 **** 0 0 **** 0
Appl. @ 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0
17 Subtot RSH gain=7+8..+12+16 55 **** ****119 **** **** 1654 **** **** 118
Less external cooling 0 **** **** 0 **** **** 0 **** **** 0
Less transfer 0 **** **** 0 **** **** 0 **** **** 0
Cooling redistribution 0 **** **** 0 **** **** 0 **** **** 0
18 Duct gain 5% **** 3 5% **** 6 5% **** 81 5% **** 6
19 Total RSH gain=(17+18)*PLF 1.00 **** 57 1.00 ****125 1.00 **** 1735 1.00 ****124
20 Air required(cfm) 2 2 6 5 79 75 5 5
Calculations approved by ACCA to meet all requirements of Manual J 7th Ed.
wrightsOft® 2019-May-02 13:45:51Right-Suite®Universal 2017 17.0.16 RSU25116 Page 34CCN ...cott.langeworthy\Documents\York\lot 16 spec.rup Calc=MJ7 Front Door faces: N
Rig ht-J®Worksheet Job: lot 16 spec
Entire House Date: May 02,2019
foothill builders Plan: 1430
MANUAL J:7th Ed.
1 Name of room Room13 Room14
2 Length of exposed wall 13.0 ft 79.0 ft
3 Room dimensions 7.0 x 6.0 ft 1.0 x 637.0 ft
4 Ceilings Condit.Option 9.0 ft heat/cool 9.0 ft heat/cool
TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Area
EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg Htg Clg Htg Clg
5 Gross a 12E3 5.4 1.0 117 **** ****711 **** ****
Exposed b 0 0 Will **** ****i i i i i i **** ****
walls and c 0 0 111111 **** ****111111 **** ****
partitions d 0 0 111111 **** ****win **** ****
e 0 0 111111 **** ****rum **** ****
f 0 0 111111 **** ****Him **** ****
6 Windows and a 3A0 39.7 ** 0 0 **** 60 2380 ****
glass doors b 0 ** 0 0 **** 0 0 ****
Heating c 0 ** 0 0 **** 0 0 ****
d 0 ** 0 0 **** 0 0 ****
e 0 ** 0 0 **** 0 0 ****
f 0 ** 0 0 **** 0 0 ****
7 Windows and North 19.0 0 **** 0 30 ****570
glass doors NE/NW 0 0 **** 0 0 **** 0
Cooling E/W 68.0 0 **** 0 30 **** 2040
SE/SW 0 0 **** 0 0 **** 0
South 34.0 0 **** 0 0 **** 0
Horz 0 0 **** 0 0 **** 0
8 Other doors a 10D0 33.1 6.3 0 0 0 63 2087 394
b 0 0 0 0 0 0 0 0
c 0 0 0 0 0 0 0 0
9 Net a 12E3 5.4 1.0 117 632 119 588 3175 600
exposed b 0 0 111111 0 0 111111 0 0
walls and c 0 0 nun 0 0 111111 0 0
partitions d 0 0 1 1 1 111 0 0 111111 0 0
e 0 0 111111 0 0 win 0 0
f 0 0 111111 0 0 111111 0 0
10 Ceilings a 16G0 2.4 1.1 42 100 47 637 1514 715
b 0 0 trim 0 0 111111 0 0
c 0 0 111111 0 0 111111 0 0
d 0 0 111111 0 0 min 0 0
e 0 0 111111 0 0 111111 0 0
f 0 0 111111 0 0 min 0 0
11 Floors a 1910 1.7 0 0 0 0 0 0 0
Note:room b 0 0 111111 0 0 111111 0 0
perimeter c 0 0 111111 0 0 111111 0 0
is displ.d 0 0 111111 0 0 111111 0 0
for slab e 0 0 will 0 0 111111 0 0
floors) f 0 0 111111 0 0 111111 0 0
12 Infiltration a 168 10.3 0 0 0 123 20610 1272
Ventilation 0 0 0 0
13 Subtotal loss=6+8..+11+12 732 **** **** 29766 **** ****
Less external heating 0 **** **** 0 **** '***
Less transfer 0 **** **** 0 **** ****
Heating redistribution 0 **** **** 0 **** ****
14 Duct loss 6%46 **** 6% 1875 ****
15 Total loss= 13+14 778 **** **** 31640 **** ****
16 Int.gains: People @ 300 0 **** 0 0 **** 0
Appl. @ 1200 0 **** 0 0 **** 0
17 Subtot RSH gain=7+8..+12+16 166 **** **** 5591 **** ****
Less external cooling 0 **** **** 0 **** ****
Less transfer 0 **** **** 0 **** ****
Cooling redistribution 0 **** **** 0 **** ****
18 Duct gain 5% **** 8 5% ****273
19 Total RSH gain=(17+18)*PLF 1.00 ****175 1.00 **** 5864
20 Air required(cfm) 8 8 316 253
Calculations approved by ACCA to meet all requirements of Manual J 7th Ed.
2019-May-02 13:45:51wrightsoft® Right-Suite®Universal 2017 17.0.16 RSU25116 Page 4
ACC ...cott.langeworthy\Documents\York\lot 16 spec.rup Calc=MJ7 Front Door faces: N
NORTH EASTBUILDING PERFORMANCE ADVISORS
Serving the Capital District, Saratoga and Adirondack Regions
March 31, 2020 7 Rocky Ridge, Warrensburg, NY 12885
Foothill Builders LLC
9 Mountainside Drive
Queensbury, NY 12804
RE: Blower Door Test for NYS Building Code,
Mr. Joseph Leuci:
After inspection of the New 1 Story Home at 55 John Clendon Road, Queensbury,
New York and completion of a Blower Door Test consistent with the practice of
depressurization to 50 Pascal in a winter condition with the exterior windows and
doors shut and the interior doors to all the rooms open, my observations are as
follows:
This home tested passed the current New York State Building Code for Air Changes
per Hour @ 50 Pascal of less than or equal to 3 ACH/50 (for Homes permitted after
stNovember1, 2016). The tested number is 2.878 ACH/50 Pascal.
The total volume of conditioned space at 55 John Clendon Road is 25332 cubic feet
taking into consideration all conditioned space in the home. The cubic feet per
minute @ 50 Pascal was 1215 CFM/50. The height correction factor for New York
State is 19 for a one story building, as such the tested home @ 55 John Clendon
Road, has the natural rate of air exchange of 0.15146 air changes per hour/natural or
64 cfm natural air infiltration credit based on the blower door test.
In the latest (2013) version of ASHRAE 62.2, high-performance homes need to be
ventilated at 7.5 cfm per bedroom + 1, plus 3 cfm per 100 square feet of living space.
That means for 3+1 bedrooms it would need 1437 sq ft/100 times 3 cfm= 43 cfm + 30
cfm or 74 cfm total for a deficit of about 10 cfm. It would also be advantageous to
use the bathroom and kitchen fans to help control humidity and set or run a fan or
HRV in the heating season to improve indoor air quality and make up for the deficit.
My credentials are as follows:
BPI Certified Building Analyst
BPI Certified Envelope Specialist
BPI Certified Heating Professional
If you have any questions regarding my findings please feel free to contact me.
Sincerely,
Jack Towne
1.888.472.2774
7 Rocky Ridge Road 4A Vatrano Drive
Warrensburg, NY 12885 Albany, NY 12205
Phone (518)623.7016 Phone (518)350.2941
Fax (518)623.7015 Fax (518)694.0102