Loading...
98-523 . ifilW TOWN OF QUEENSBURY /..switi.1 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY C/O Number: C20000492 C/O Date: Monday, July 31, 2000 Application Number: 98523 Permit Number: 98523 This is to certify that work requested to be done as shown by Permit Number 98523 has been completed. ' This structure may be occupied as a Porch Tax Map Number: 523400-051-000-0002-002-001-0000 Location: 1118 BAY Rd Owner: JOHN & LARA MEHR CURRIE By Order of Town Board r7FarNIUIROt Director of Building&Code Enforcement ,11 BUILDING PERMIT TOWN OF QUEENSBURY VALUE $ 7000 No. qgc9 TAX MAP NO. 51 . -2-2. 1 WARREN COUNTY, NEW YORK PERMISSION is hereby granted to CURRIE, JOLIlti _ LARA_ MEHR OWNER of property located at 1118 BAY RD. Street.Road or Ave. in the Town of Oueensbury,To Construct or place a PORCH at the above location in accordance to application together with plot plans and other information hereto filed and approved and in compliance with the Town of Oueensbury Building and Zoning Ordinance. t. OWNER'S Address is CURRIE 1118 BAY RD. LAKE GEORGE, NY 12845 2. CONTRACTOR or BUILDERS Name CURRIE, JOHN 3. CONTRACTOR or BUILDERS Address 4. ARCHITECT'S Name 5. ARCHITECTS Address 6. TYPE of Construction—(Please indicate by XI PORCH I Wood Frame ( I Masonry ( I Steel 1 1 7. PLANS and Specifications 224fa FT PORCH AS PER PLOT PLAN SPECIFICATION 8. Proposed Use PORCH 16 August 28 2000 $ PERMIT FEE PAID —THIS PERMIT EXPIRES 19 (If a longer period is required an application for an extension must be made to the Building and Zoning inspector of the town of Oueensbury before the expiration dete.l 28 August 1998 Dated at the Town of Oueensbury this Day of 19 SIGNED BY for the Town of Oueensbury Building a Zoning Inspector . ,,, , iAP1J .. TOWN OF QUEENSBURY Fee Paid ree BUILDING & CODES DEPARTMENT Permit 11 APPLICATION FOR: PORCHES-DECKS- DOCKS & BOATHOUSES Est. Cos A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. PLEASE ANSWER ALL OF HE FOLLOWING: The undersigned hereby applies for a Building Permit to do the following work which will be done in accordance with the description , plans and specifications submitted, and such special conditions as may be indicated on the permit. TWO SETS OF STRUCTURAL PLANS SHALL BE SUBMITTED WITH THIS APPLICATION. Owner of Property: a G,n sr ,ter e.� �,u r J-/ , (fir S P.O. Address .11 ld'' exsci pd ,4� �,, Phone Property Location , I J 1 I A �o ,e L Tax Mari II .1-, -�, Subdivision Name (If applicable) PERSON RESPONSIBLE FOR SUPERVIS ON OF WORK AS REGARD TO BUILDING CODES: Name: Address Phonell BUILDING SPECIFICATIONS: Type of work to be done: Porch Deck Dock Boathou e Ci cle one) /7 Size of Structure to be bui square footage) : 50--e-er—e _ [� In Foundation Material : Width V L 5e v�7 Thickness `` u e '11- �J Depth of Footing, below grade: /� `pr-r.„4._ Size of Posts or Studs: 14 x 1 x Long Size of Floor Joists: -7 6 x it) x Span ‘t O. C- Decking or Flooring Material : CCP/> C/__ How will Porch or Deck be fastened to building? LA:VC., , u00 � Avr3y 1998 If Roof Will Be Installed, Answer Followi g Questions « r� Size of 'Posts or St ds: x x r Long Roof Rafters: �tS�c � Spacing ` Span , � f Roof Trusses (pre-engineered spacing) : ' Q, e Span /(C " Type of Roof: Sloped Flat Sh5d Other (Circle one Material of Roof: p6&f -�Sr7ki /e- /J / ,— ZONING INFORMATION: TWO PLOT PLANS MUST BE PREPARED AND SUBMITTED, drawn reasonably to scale and attached hereto, showing clearly and distinctly all buildings, whether existing or proposed and indicate all set back dimensions from property lines. Show location of water supply and location and configuration of septic disposal area. ' / Size of Property: ",�� ft. x /6 ft. Existing building(s) : Size , f ft. x 1 7` ft. Size .vi( ft, 37 ft. Use of Existing building(s): 1 /-c-' Proposed structure, distance from proper line: Front yard 2S1f_ft. Re yardf�� ft. Side yards ft. and t. If on corner, setback from sid s`�re t: ft. DECLARATION To the best of my knowledge and belief the statements contained in this application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with, whether specified or not, and that uch work is authorized by the owner. DATE: ,e04 SIGNATURE _.---C -i_ er, Owner s Agen • , Ar 'ontractor REVIEWED BY CODE ENFORCEMENT OFFICER, DATE 66 SIGNATURE RESIDENTIAL FINAL INSPECTION REPORT Office No.(518)761-8256 Date inspection request received: Building&Code Enforcement Dept.of Community Development Arrive.!m/pm Depart Town of Queensbury Inspector's al ---- f 742 Bay Road Queensbury,New York 12804 NAME t LOCATION �a DATE - C b TYPE OF STR N/A YES NO COMMENTS Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake Plumb Vent through roof Roof Complete Exterior Finish Complete Interior/Exterior Railings 30"to 36" Exterior Handrails,balconies,landing 18 in.or more Interior Handrails stairs both sides 3 or more risers Grade 2%away from foundation 8"clearance to sill plate Gas Valve shut-off exposed/regulator 8"above grade Gas Furnace shut-off within 30 feet ' wi line of site Oil Furnace shut-off at entrance to ' i area Furnace/Hot Water Heater operat. Relief Valve(s)installed Headroom,6 ft.6 in.on stairs Basement stairs,6 ft.4 in. Handrail exterior stairs both•des • ore than 3 risers Interior privacy/trim/doors/ •:'• entrance 36" Floor Finish Bathroom/Kitchen,wat t Interior Handrails. com :'ding 18 in.or more Railing across window in ells Smoke Detectors: every level every bedroom outside every bedroo inter connected I Bathroom fans Plumbing fixtures Foundation insulatio %hour fire door/d closer Garage fireproofing,/ Garage penetrations sealed Furnace in separate room protected(in garage) Light ventilation per room Safety glazing 18"or less from floor Final Electrical Site Plan/Variance required Final Survey Plot Plan As Built Septic System layout required Okay to issue C/C(Certif.of Compliance) Okay to issue temp.C/O(Certif.of Occupancy)_ Okay to issue permanent C/O(Certif.of Occupancy) RESIDENTIAL FINAL INSPECTION REPORT Office No. (518)761-8256 Date inspection request received: Building& Code Enforcement • Dept. of Community Development Arrive ;/,4' am/pm Depart am/pm Town of Queensbury Inspector's Initials 742 Bay Road Queensbury,New York 12804 NAME /T PERMIT# - - 3 LOCATION >'p DATE "4417/S TYPE OF STRUCTURE N/A YES NO COMMENTS Chimney HeightP'B"Vent/Direct Vent Location Fresh Air Intake Plumb Vent through roof Roof Complete Exterior Finish Complete Interior/Exterior Railings 30"to 36"--"---__. / nevil� � Exterior Handrail ,balconies, ding 18 in. or mores irs' �,n� Interior Handrails s both ides 3 or more risers Grade 2%away from o 8"clearance to sill plate Gas Valve shut-off a regulator 18"above grade Gas Furnace shut-off " " 30 feet or within line of site Oil Furnace shut-off a entrance to furnace area Furnace/Hot Water ter operating Relief Valve(s)ins led Headroom,6 ft. 6 in. on stairs Basement stairs,6 ft. 4 in. Handrail exterior stairs both sides more than 3 risers Interior privacy/trim/doors/main entrance 36" Floor Finish Bathroom/Kitchen watertight Interior Handrails Balconies/Landing 18 in. or more Railing across window in stairwells Smoke Detectors: every level every bedroom outside every bedroom inter connected Bathroom fans Plumbing fixtures Foundation insulation 3/4 hour fire door/door closer Garage fireproofing Garage penetrations sealed Furnace in separate room protected(in garage) Light ventilation per room Safety glazing 18"or less from floor ��, Final Electrical �Y✓ ,./ '';.` Site Plan/Variance required Final Survey Plot Plan As Built Septic System layout required Okay to issue C/C(Certif. of Compliance) Okay to issue temp. C/O(Certif. of Occupancy) Okay to issue permanent C/O(Certif. of Occupancy) GENERAL INSPECTION REPORT Town of Queensbury Dept.of Community Development Date inspection request received: /,), Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive am/pm Depag n pm Inspector's Initials ..\�I,i NAME: � O�'S' `ck f' PERMIT •# • r () LOCATION: \\\c T d DATE : TYPE OF STRUCTURE: C RECHECK N/A YES NO COMMENTS Footings/Piers I Monolithic Pour Form Reinforcement in Plaice The contractor is nsible fi providing protectio from ing for 48 hours followin the • acement of the concrete. Materials for this purpose o site Foundation/Walipour Reinforcement in Place Foundation/Dampproo• i g Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heatin -In lion Foundation Walls Interior R- Foundation Walls Exterior R- /// °Floors R- I Walls R- l 1 Ceiling R- �P Duct work or piping in unheated spaces R- 144 Vent, Attic Vent _ Cct�r. &) raining t%oR F# '4i * c' I qA-K.."4 - INS ik-- wa �— 1)is, -P Jack Studs/Headers Tt,Q l Ut ''co I„05,6, , Bracing/Bridging j4ist Hangers j ack Posts/Main Beam -✓ Air Infiltration Barrier Fire Separation 1, 2, 3. hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping 2 -�-� � 01,ky, (61 GENERAL INSPECTION REPORT Town of Queensbury Dept. of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive l..,Ira eparl Inspector's Initip-14111 " N‘NN.),_}\ PERMIT# LOCATION. (F)G1(J U DATE : - I -�qI TYPE OF STRUCTURE: Q",r(`RECHECK N/A YES NO COMMENTS Footings/Piers I I Monolithic Pour Form Reinforcement in Place The contractor is ,..•nsible for providing protectio fro • freezing for 48 h,urs folio ng the ,lacement of the con.. te. Materials for this •.-.••se on si • Foundation/Wallpour Reinforcement in Pl. Foundation/Dampproo l ng Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in 'lace Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- f : c --A•) Walls R- Ceiling R- Duct work or piping in unheated spaces R- Prope nt, Attic Vent ming Jack Studs/Headers Bracing/Bridging ty/,(, -rt Joist Hangers Lam --- ‘1 -7.011w\bt Jack Posts/Main Beam ' Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour � iS 5V\�SD Firestopping 411 V-1/0( GENERAL INSPECTION REPORT Town of Queensbury Dept. of Community Development Date inspection request received: it itoi/k Building& Code Enforcement / /O) 742 Bay Road Queensbury,NY 12804 Arrive �/ cc am/pm Depart am/pm Inspector's Initi�<2 NAME: (-urn e PERMIT# �g' ��3 LOCATION: 11 DATE : TYPE OF STRUCTURE: .SGrCCtAiir-q'rel` RECHECK N/A YES/NO COMMENTS •tin y. VI Monolithic Pour Form i _So f o Reinforcement in Place The con or is responsible for 1 " �2-" f,���� c�' ,� l"r,c j providing pro 'on from mgr c�T for 48 hours foll wing placement of the concrete. Materials for this on site Foundatio 1pour Reinfo ment in Place Foun tion/Dampproofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2. 3, 4 hour Firestopping TOWN OF QUEENSBURY DEPARTMENT OF COMMUNITY DEVELOPMENT w 0 W BUILDING PERMIT NUMBER al airea c) q q —502 3 tir-i--w .z: (4 )- 1. BASIC/BUILDING PERMIT INFORMATION: aa.., Applicant/Name & Address Agent/Name & Addre 4 n applicant agent O . - TAX MAP NUMBER:' 98523 51 .-2-2 . 1 /- -.2` a CURRIE, JOHN & LARA MEHR NI 1118 BAY RD. MiEll - — -- A /�,�PORCH - o 1,54 e• 2. PROJECT DESCRIPTION: __ ❑ plot plan (2 copies) RW ' __ __ G �-` ❑ building plan (2) TiVr43_ 0 sewage disposal energy code 3. PROPERTY INFORMATION: Delectrical inspection Ddriveway permit SETB C S REQUIRED ACTUAL ❑completed/signed re-, ❑ FEE PAID Front Yard MI�_ � W ? , _ Front ( if corner) 11111M��� i M � NvM � NEW CONSTRUCTION Side Yard (1) i to �'- BrA' Side Yard (2) ��7' . ❑ ADDITION Rear Yard 111§2: WA 0 ALTERATION Width limommiElMODIFICATION 0 De.th SIC*hT . YES NO N/A PROPERTY IS IN APPROVED SUBDIVISION 1 ti ati-ir-. ' Meets depth, width & square footage requirements . Preexisting, nonconforming lot with proper setbacks Required road frontage on public road Has required off-street parking Permeable area is adequate /[Required: Building does not exceed maximum height/ Max. ft. Required setbacks from stream, lake and/or travel corn.or meets requirement t Buffer zones required Is lot in a Flood Plain Zone? • OVER 4. STAFF DETERMINATION: As per Section(s) 11 of the Zoning L I Sign (_] Subdivision Ordinance Ordinance Regulations 0 OV'CAAn, C4/1"9• &(,(J &44 • w . • f o !.L f ' ifs / I .vn�/ Lis k. u- 5. REVIEW REQUIRED BY ZONING BOARD OF APPEALS: ACTION FILE NUMBER RESOLUTION DATE ED Use Variance 0 Area Variance El Sign Variance El Other Comments: 6. REVIEW REQUIRED BY PLANNING BOARD: ACTION FILE NUMBER RESOLUTION DATE 0 Site Plan Review Subdivision E] Planned Unit Dev. ED Other Comments: REVIEWED BY STAFF DATE COMMENTS ( ?� § 179-16 QUEENSBURY CODE § -1 WR-1A WR-3A Lot area 1 acre 3 acres Lot width 150 ft. 50 ft. Lot depth N/A /A Front setback 30 ft. ;0 ft. Side setback* 25 ft. 5 ft. Rear setback 25 ft. 25 ft. Shoreline setbacks 50 ft.*** 75 ft. Minimum permeability required 65% 65% Maximum Building Height Principal structure** 28 ft. 28 ft. Detached accessory 16 ft. 16 ft. structure Maximum %floor area ratio 22% 22% Lot size/dwelling 1 acre 3 acres Notes: *Lot width of: 50 feet or less equals 12 feet for each side and rear setback Greater than 50 feet up to and including 60 feet feet€gr each side and rear setback Greater than 60 feet and less than 150 feet equa s nd rear setback **As measured along a vertical p ane om the high point of the building/structure to grade at any point adjacent to the building or structure. ***Or the average setback of the houses on the two (2) adjoining lots,whichever is greater. G. Compliance with septic regulations. Any increase in the floor area of an existing structure serviced by sanitary facilities which requires a building permit shall conform with the requirements of Chapter 136. 17962 io-25-ss , • 5 1 o C r--, if e Front Yard Setback 30' g r r_ _1 i G co co g, I I I I I I otti � L I CD is N �. I I I I I i'. I I I I I ( I I a 0 0 flZ 1x'I tz' I p I ( I I I 0 b L__— J 15 L. —1 ' L-. `.J ZS L — CN Od M, Shoreline setback 50', or average setback of the (1) o 4 two adjacent houses, whichever is greater P y r : o o a. Lot Width 0-50' >50,: 60' >60'and <150' 150'and greater o -- �-+ t� cm _ 0 ►.+ 1 0 tJ in 0, 1 . gs,... 5„... ..... ,...... .,.,,,, . . .., ,...... . , .. .. NOTICE NSULATION MUST BE COVER ��t(1 Y '. 15 MINUTE THERMAL BARRI FILECLIp' Y : NOTICE TOWN OF QUEENSBURY BUILDING DEPARTMENT 'PIPER INSULATION MUST A.FB Based on our limited examination, compliance with our comments shall 1 r " g • -COMBUSTIBL3� not be construed as indicating the plans and specifications are in ful l II compliance with the code. t , •: .,..- p:i ttll t tt It t{ i h t I �I t t i tt 1tt t tt., ,, it t tt� I • ilt__ _�( ��bt +� I 1 tx E`�fr // ,x i 6 tip � 2-by,40 • • i i i i I • . ...........................:*............. .......................................... .......................................... .......................................... I:y:E:::::::::i ?:Y :%:::::=:%3: ES: :::::0..:: K:is?E:�.:.:,...!;x.';::: :%� £:: ::S: �:%i.i'l:cr:: :; :a:a::->:->::-::::*:R::::::::iS:F::: I I :::>E><:':>:E>::::::E::>::E::::::::>::::::::*:::E,::::%.�%{x.x. :>:z i*33i z<: ?:i: ............................................:E:::-!:: : ::•::::.: <: : ::::> ::: ::::::E$:::::::: :::::::::::' :: ,.,,...::;:: t::'::: :j; ;F: :: :: i : : ; ::I ::% ? : : : I ::1 j is :::i :: ;:::I:::::::::::::2`::?2::::::::::>:Y::.*::::::::::::: . F:::.,:::::::::::::::3 :::::::::: ::::: :i:: :::::: E::11111111111.1111111.11 <: t: P;::t.>:-:::::>::::::-:::r: ::::s:::: ::<a::•:tc: I ::i` 1 ` .::::.':`:`'::::—.:::::::: ;::'::.:•:::::::.::::'::: ?, K.: ::I ;;� ::i ,i «i c- a i , I ":•...•"::::.:...:::......:::......:::...1...I:::I.;•:...::'.1:::....•••.:*..'....•..•:::::::.".::::..!.*..::•.'...'''. 25 YEAR 3/SG ASPHALT SHINGLES OVER 30 LB. FELT EX S 2"x 4" FINKI TING BUILDING TRUSS 24" O.C. <'>< .. 16' SPAN .:...:..:..:.:.:. «.:...... 6/12 PITCH 90 SQ. IN. ALUM. VENT (2) v ......4e\ 5/8" CDX ROO PROPER VENT KIT R-381 S U LA SHEATHING . • • • • • • • • • • 2" x 12" HEADER W/1/2" PLYWOOD LAMINATE CENTER `<>•:..:<.>:..€.>:.>€.€.>€.> ••••••• ••:<::;<::;<: • 3/8" PLY SOFFI T I I I� 1 x6 FASC IA W/STRIP RIP VEN T II 4IIx 4 STUD S I 4FTmi o.c. I� II SI LL 2x4 'LL STUDS`� �� R-13 INSULATI0 NM Iliggiiiiigi 2" x 4" PLATE 1" x 5" T&G FLOO `>< 2" x 10 JOIST S 16"6 O.C. II I I ..[NS 6 x 6 PRESSURE ��.-:.; «:>:>.:.<:.<:.:. GRADE 4 FT BELOW GRAD E iljx..— ir144114N'444444%SS\,44 ftmm 40/.....°1/1°.°/....°1/..:11:. 16" x 16 FOOTING -�`I�IJ�' 12 DIAM. S PIER •; THE NEW YORK BOARD OF FIRE UNDERWRITERS 1,44;p; + .,' Fik1�s; ►ht BUREAU OF ELECTRICITY • .; 40 FULTON STREET, NEW YORK, NY 10038 C,.),'. . .: Date .11114E: 1' �{,lt.;}:i e.y.tc1�'r� H 443004 K 40 d • Application No. on file �/ •; THIS CERTIFIES THAT '• • only the electrical equipment as described below and introduced by the applicant named on the above application number is in the premises of :,' .' • • ,.It tHN (.1t14k 1 F , I 18 HAY IA WI . t ftlh;F;Pi:at-111k"r 1 C `9 '" G • in the following location; ❑ Basement ❑ 1st FL ❑ 2nd FL Section Block Lot '• • was examined on 'I I IN1'' I''' ->Vk Nri and found to be in compliance with the National Electrical Code.• :• .; FIXTURE RECEPTACLES SWITCHES FIXTURES RANGES COOKING DECKS OVENS DISH WASHERS EXHAUST FANS OUTLETS INCANDESCE FLUORESCENT OTHER AMT. K.W. AMT. K.W. AMT. K.W. AMT. K.W. AMT. H.P. , •' • • •' DRYERS FURNACE MOTORS FUTURE APPLIANCE FEEDERS SPECIAL REC'PT. TIME CLOCKS BELL UNIT HEATERS MULTI.OUTLET DIMMERS '. P' AMT. K.W. OIL H.P. GAS N.P. AMT. NO. A.W.O. AMT. AMP. AMT. AMPS. TRANS. AMT. H.P. NO OF FEET AMT. WATTS '. • '• '' .VICE DISCONNECT NO.OF--- - - S E R V I- -C E .if METER NO.OF CC COND. A.WrO. A.tut; A.W.O. ; AMT. AMP. TYPE EQUIP. 1♦4W 1 O SW s R SW 3 R 4W PER• OF CC.COND. NO.OF NI-LEO OF tut; NO.Of NEUTRALS OF NEUTRAL ,' • r_ OTHER APPARATUS: r O IS • r .`: 'T IY i 45" r1 s 2 r ,: — - - i t ilf 4 tt, 11 t13 B�?4' ki) i3 (a t a: IJAKha CM{3 F1 t4 , 1+t`f', I-'(“4'Y ' -. GENERAL MANAGER r .: - 1 � ' '.r-i. -' - Set '_ e; x r Per .r .; This certificate must not be altered In any manner;return to the office of the Board If incorrect.Inspectors may be identified by their credentials. ; % • • • • •i",;• "• '• • • T. '.,:r. • • ,•..;,•I,r., ,.i ,•,:r•. •1 to) le, 101 t0i".:r.i T.Y r.Y i.YY•7;Y•Y;f•Y,Y.ir,.'w;r•7"w"'w( 101 i•v '.,w T•(, •Y'w w A COPY FOR BUILDING DEPARTMENT. THIS COPY OF CERTIFICATE MUST NOT BE ALTERED IN ANY MANNER.