Loading...
2002-420 TOWN OF QUEENSBURY Foirs 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20020420 Date Issued: Friday, May 23, 2003 This is to certify that work requested to be done as shown by Permit Number P20020420 has been completed. Tax Map Number: 523400-265-000-0001-075-000-0000 Location: 1376 BAY Rd Owner: TODD & ELIZABETH HUBER Applicant: TODD & ELIZABETH HUBER This structure may be occupied as a: By Order of Town Board Deck TOWN OF QUEENSBURY 1. _. Director of Building&Code Enforcement TOWN OF QUEENSBURY ea, 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 ION Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20020420 Application Number: A20020420 Tax Map No: 523400-265-000-0001-075-000-0000 Permission is hereby granted to: TODD & ELIZABETH HIJBRR For property located at: 1376 BAY Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: TODD & ELIZABETH HUBER 1,100.00 1376 BAY Rd Deck Total Value 1,100.00 LAKE GEORGE,NY 12845 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2002-420 296 SQ FT DECK AS PER PLOT PLAN SPECIFICATIONS $40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, May 30,2003 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated own f lens• • ; / hursday,May 30,2002 fi 11 SIGNED t for the Town of Queensbury. Director of Building&Code Enforcement _ TOWN OF QUEENSB0RY Fee Paid BUILDING & CODES DEPARTMENT 'Perm�t # � APPLICATION FOR: PORCHES- DECKS-DOCKS & BOATHOUSES Est.* "tost � A PERMIT MUST BE" O8TAlNED BEFORE BEGINNING CONSTRUCTION'. PLEASE ANSWER ALL Or T>{E' FOLLQWlNG: The undersigned hereby applies for a Building Permit to do the following work which wil7 be done in accordance with the description, plans and specifications b itt d d such special conditions as may be indicated on the permit. TWO SETS OF STRUCTURAL PLANS SHALL BE SUBMITTEDWITH THIS APPLICATION. Owner of Property: 7"o-'90 Property Location 51 Subdivision Name (If applicable) PERSON RESPONSIBLE FOR SUPERVISION OF WORK AS REGARDS TO BUILDING CODES: Name: Address 5�,y Phone#1 BUILDING SPECIFICATIONS: Type of work to be done: Porch �eck,3 Dock Boathouse. (Circle one) Size of Structure to be built (s uare footage) : C91 �,6-1, Foundati,on Material : '- Width Thickness .5�� ~~p~^ of ^ ~~~''^y below grade- Size of Posts � s or Studs: u s: n gLomg � -'-- of"Floor -_'_--' ~ ~ SpanDecking. or Flooring Material : 49rr &_-7?- How will Porch *or Deck be fastened to buildi ? F/e If Roof. Will Be Installed, Answer Following- Questions: -`,0R;=0FRVED Size of Posts or Studs: x x Long Roof Tr usses (pre-engineered spacing): Span -TOMINOFOUEENSBURY' 1�4KIG AND CODE Type of Roof:: Sloped Flat Shed Other (CircTe One Material of Roof: ZON.ING INFORMATION: TWO AND SUBMITTED, drawn reasonably to scale and � aohed ,hereto, showing� distinctly -° whether existing nr proposed d Indicate all set back dimensions from property lines. Show location of water supply 'and location and configuration of septic disposal area-. Size of Property: 2 1 C2 � ft. x ft. Existing buiTdYng(o): Size 2 4/ ft. x 6L? ft. ' Size f�. u �---- ft. Use of Existing buildfng(s):---- ---- - ' Proposed structure, distance from property line: .' � . Front yard ft. Rear yard ft. ' Side yards f±. and ft.------- | ' If on corner, auk from side street: ft. / DEdARATD0N . -To the bast of my knowledge and belief the statements contained in this appJi together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions o �the Building Code, the Zoning Ordinance, and all other laws pertaining to the proposed rk shall be complied with. whether specified or not, and that such work is authorized the owner. owner. / ' ' DATE: SIGNATURE . _---. . Owner's ..g^. e Con REVIEWED BY CODE ENFORCEMENT OFFICER, DATE SIGNATURE V\Residential Final Inspection Q Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: a ij ZDepart: arrr/ptn� 742 Bay Rd., Queensbury,NY 12804 Inspector's Initial s' I�-� NAME: t l�f \ "-\--kbp PERMIT#: LOCATION: j —1 P � .�. �, CY DATE: 5 c \ 0 TYPE OF STRUCTURE: � 5> Comments N N/ Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof ""`°' Roof Complete Guard 30 in.or more @ stairs,decks,pat'.s Guard at stairwell at 34 in.or more Guard at deck,porches 36 in.or mor- Exterior Finish Complete Interior/Exterior Railings 34 in.t. 38 in. ✓ Platform at all exterior doors Interior Handrails stairs 2 or mo e risers Grade away from foundation 6. . with 10 ft. Handrail Termination at Newe 1 Post or Wall 8 inch clearance to sill plate Gas Valve shut-off exposed/ egulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater op- ating Low water shut-off boiler Relief Valve(s)installed Interior privacy!trim/doors/ .in entrance 36 in. Bathroom/Kitchen watertight Safety glazing Window in stairwells safety glazin: Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery ba,kup: Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,0►I sf Emergency egress below grade Basement stairs closed rise>4 inches 3/4 hour fire door/door closer Garage fireproofing Duct work Sealed properly Attic access 30 in.x 24 in.x 30 in.(ht.)In acces.ible area Crawl Spaces 18"x 24"access, 1 sq. ft.-1,0 sq. ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept. nspection Sticker Flood Plain Certification, if required Okay to issue C/C(Cert. Of Compliance) Okay to issue Temporary C/0(Cert. Of Occupancy) Okay to issue Permanent C/0(Cert. Of Occupancy) L:\SueHemingway\Building.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc edited January 28,2003 t ,... ( DEPT. OF COMMUNITY DEVELO(N:ii, ZONING OFFICE 742 BAY ROAD QUEENSBURY NY 12804 )-i-, (A) I " • - .��� r _ ! CC m • Ci vv,Nf_ 444. '1:1'''''''''''''''''\.. T Zt s l ,�. • r _ ,= $ . _ • ' • / t PLAN VIEW FOR LEVEL I r`l �t� CURTIS LUMBER CO CUSTOMER -- TODD HUBER 460 BIG BAY ROAD DATE 05/17/02 REF Deck02137 QUEENSBURY NEW YORK (800) 555 1212 �� �^ 1 tfrZ7 D.PAR I9 MEW COPN tart"ir.rt,iril�9{s Xr3tnittetrJn Timm -� erns snap bof, s indicating the s Fdsp,.cilcr_,tinrs are in full the MAY , 3 2002 •71- CD I TCS'VN 0Us ENSBURY /1":10 1 I ■ I 1 i / Q✓ C 4 111 I E-- 440 he'd A-4 , 7 LOAD AND SUPPORT: Your deck will support a 63 PSF live load. Posts have 48" below-ground post support. DECK AND POST HEIGHT: You selected a height of 64" from the top of decking to level ground. The top of the deck support posts will therefore be 55.25" above ground level. Your salesperson can provide information for uneven or sloped ground. • JOISTS: Set joists on top of beams, 16" center to center. NOTE: The design may require knee braces and bridging between joists. Your materials list includes the necessary items. The suggested design is not a finished building plan. You are responsible for all measurements being correct, for verifying that the design (and any substitutions or modifications that you make) meets all local building codes and requirements. To verify that the suggested design, and any substitutions or modifications, is consistent with conditions at the construction site, review the design with your architect. Also consult your architect for proper construction and use of materials in the structure. Be sure to follow the deck construction detail available from your store salesperson. TOWN OF Q U .E °" w U RV BUILDING / ; • ' Tirt REVIEWED BY � 44T Al DATE .CIx, P PLAN VIEW FOR LEVEL 2 CURTIS LUMBER CO CUSTOMER -- TODD HUBER 460 BIG BAY ROAD DATE 05/17/02 REF Deck02137 QUEENSBURY NEW YORK (800) 555 1212 6' .4 1 i I pl10 04 .' ., 1/0000" , � I v I i 0010°I I i i LOAD AND SUPPORT: Your deck will support a 206 PSF live load. Posts have 48" below-ground post support. DECK AND POST HEIGHT: You selected a height of 57" from the top of decking to level ground. The top of the deck support posts will therefore be 48.25 above ground level. Your salesperson can provide information for uneven or sloped ground. JOISTS: Set joists on top of beams, 16" center to center. NOTE: The design may require knee braces and bridging between joists. Your materials list includes the necessary items. The suggested design is not a finished building plan. You are responsible for all measurements being correct, for verifying that the design (and any substitutions or modifications that you make) meets all local building codes and requirements. To verify that the suggested design, and any substitutions or modifications, is consistent with conditions at the construction site, review the design with your architect. Also consult your architect for proper construction and use of materials in the structure. Be sure to follow the deck construction detail available from your store salesperson. • cr ovn cit\\ ,c...i0 Q W CO N ov "v We � CC a W , ffi '- s€ y. n _ "(J at-kAn- � .` Ir is ie Aft 4,4" V: •,'-,4,00-If'.,.':,`_N'/I 00 . . +L., l''•- ' • '''rleiflkg, 01-4:;.; At �trof m4 If ��� 2 .a`s of if �r t. CO N Ntttt�+ ' CC O 'p� • cu CC r O - _ W_ f 1- > W Lo `2 22 O 00 F— F— W GO CO - » a 0 0 a STRESS ANNASI FOR LEVEL 1 CUSTOMER: TODD HUBER DATE: 05/17/02 DESIGN: DECK02137 REF: SALESMAN # MEMBER STRESS FACTOR COMPOSITE TYPE SIZE FACTOR LOAD LOAD JOISTS 2X8 DEFLECTION 263 PSF 16IN BENDING 226 PSF SHEAR 167 PSF COMPRESSION 269 PSF 167 PSF BEAMS 2-2X10 DEFLECTION 154 PSF BENDING 86 PSF SHEAR 74 PSF COMPRESSION 332 PSF 74 PSF BOLTS 1/2IN SHEAR 2967 PSF 2967 PSF POSTS 6X6 STABILITY 974 PSF 974 PSF TOTAL LOAD 74 PSF DEAD LOAD 10 PSF LIVE LOAD 64 PSF