Loading...
SEP-0022-2020SEPTIC DISPOSAL PERI Town of iance?____Yes No 1742 Bay Road,Queensbury,NY 12806 P:518-761-8256 www queensburynet pemte SeP-O0Aa-2o%d|p|ny ‘Tax Map ID #:_307.-1-29 Project Location:_North West Lodge,Northwest Road,West Mountain Ski Resort *Applicant: Name(s):Apex Capital,LLC (Contact:Spencer Montgomery) Mailing Address,C/S/Z:_14 Woodridge Road Queensbury,NY 12804 Cell Phone:_(518)696-5371 Land Line:_() Email:spencer@wesimin.net ¢PrimaryOwner(s):Name(s):Apex Capital,LL Mailing Address,C/S/Z:_14 Woodridge Road Queensbury,NY 12804 Cell Phone:_(518 __)745-9802 Land Line:_() Email:_spencer @wesimtn.net O Check if all work will be performed by homeowner only *Contractor:Workers’Comp documentation must be submitted with this applicationContactName(s):10 be installed by West Mountain staff -Ronald Nolin Contractor Trade: Mailing Address,C/S/Z: Cell Phone:_(518)791-0492 Land tine:_() Email: +Engineer(s): Name(s):Hutchins Engineering _Mailing Address,C/S/Z:169 Haviland Road Queensbury,NY 12804 Cell Phone:_()Land Line:(518)745-0307 Email:thutchins @hutchinsengineering.com Contact Person for Building &Code Compliance:Fon Nolin /Hutchins EngineeringCellPhone:(518 _)_791-0492 Land 2Email:_spencer@ westmin.net Septic Appcation Revised February 2019, RESIDENCE INFORMATION: Year Built [Gallons|#of bedrooms:|Xgallons per|=total dally flow per day bedroom |Garbage Grinder Yes (No 1980 or older|150 Installed?(circle one) ‘Spa or Hot Tub Yes (No :Bisesrwer| 10 a Installed?(circle one) | 1992-Present |110 980 GPD (see plats) PARCEL INFORMATION:—|Topography ¥_Fiat Rolling Steep Slope‘%Slope [Soil Nature Sand 7 Loam Clay ‘Other (explain:I [Groundwater At what depth?51°_Bedrock/Impervious material|At what depth?greater than 72" Domestic Water Supply.‘Y¥_Municipal__Well (if well,water supply from any septic system absorption is ft.) Percolation Test Rate:per minute per inch (test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: Tank S 2e1 500 &750g.075 (ITEBHEpeters—eeteirttemiimmahneenetnenteenechccprisenttelh System Absorption field with #2 stone_|Total length Trench ‘Seepage Pit with #3 stone How many:3 Si Alternative System Bed or other type: Holding Tank System Total required capacity?Tank size >Hof tanks 24*Wide Chambers Total 480 LF /each 60° NOTES:1.Alarm system and associated electrical work must be inspected by a Town approved electrical inspection agency;2.We will no longer allow systems to be covered until such time as an as-built plan is received and approved.The installed system must match the septic layout on file—no exceptions.3.As-built drawings must be submitted prior to the inspection,if there has been a change to the submitted plans. Declaration:Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void.|have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME:Sete oe Mes “yom YL ome:£0 SIGNATURE:<2 ZE Menta pare: ‘Septic Appeation ewsed February 2019 Empire State Plaza, Corning Tower, Albany, NY 12237│health.ny.gov February 3, 2020 Mr. Thomas Hutchins, PE Hutchings Engineering 169 Haviland Rd. Queensbury, NY 12804 Re: Onsite Wastewater System Approval Northwest Lodge (West Mtn.) Facility Code 56-BG64 Queensbury (Town), Warren County Dear Mr. Hutchins: We have this day, approved the plans for the above-referenced project. Application for this project was duly made by you and was most recently received by the New York State Department of Health on January 22, 2020. This project includes the replacement of Onsite Wastewater Treatment Systems to serve the Northwest Lodge at West Mountain. Approval of these plans is conditioned on the following: 1. That the proposed works to be constructed in complete conformity with the approved plans or amendments thereto; 2. That all components of the proposed works be installed, operated, and maintained as per the manufacturer’s specifications; 3. That approval be granted by other agencies or municipalities having jurisdiction; 4. That the design professional inspects the construction and provides certification to this office that construction was completed in accordance with the approved plans. Certification shall also be provided to the Town Office Building and Code Enforcement. The responsibility for the design of the sanitary system lies solely with the design professional and the proper operation of the sanitary system lies solely with the owner. The purpose of the department of health review is for compliance with the New York State Sanitary Code and in no way guarantees proper system operation. A set of approved plans is being retained for our files. Sincerely, R. Dan MacElrath Assistant Engineer Glens Falls District Office Cc: Spencer Montgomery, Owner Anita Gabalski, GFDO Corey Dilorenzo, GFDO David Hattin, Queensbury Code Enforcement 169 Haviland Road Queensbury, NY 12804 Hutchins Engineering Phone: (518)745-0307 Fax: (518)745-0308 January 22, 2020 John O'Brien Town of Queensbury 742 Bay Road Queensbury NY 12804 Re: Apex Capital, LLC. Wastewater system for Northwest Lodge 59 West Mountain Rd. Dear Mr. O'Brien: Attached please find three sets of revised plans for the replacement wastewater system to serve the Northwest Lodge, West Mountain ski area. In accordance with our discussion, we have revised the kitchen sewer to 4 inch and included additional information specifying vertical separation from boundary condition on the absorption field section. Please contact me if you have any questions or if you require additional information. Best Regards, G. Thomas Hutchins, P.E. Cc: Spencer Montgomery JAN22Z0 G.Thomas Hutchins,P.E. thutchins@hutchinsengineedng.com