CC-0468-2019TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5904 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 BUILDING PERMIT CC-0468-2019PermitNumber: 303.15-1-32TaxMapNo: Just Goods, Inc. Permission ishereby granted to: 276 DIX AVEForpropertylocatedat: In theTown ofQueensbury, to construct orplace atthe above location in accordance with application together with plot plans and other information hereto filed and approved and incompliance with the NYS Uniform Building Codes and theQueensbury Zoning Ordinance Type ofConstruction NYS Job Development Authority$200,000.00OwnerName:Business Office - Alteration Owner Address:633 Third AVE Total Value 200,000.00 New York, NY 10017 Contractor orBuilder'sName / AddressElectrical Inspection Agency Rozell Industries Inc. 129 Park RD Queensbury, NY 12804 Plans & Specifications Interior Alterations (offices) 2565 s.f. 769.50 Thursday, July 30, 2020PERMITFEEPAID - THIS PERMIT EXPIRES: Ifalonger period isrequired, anapplication for an extension must bemade to the code Enforcement Officer ofthe Town ofQueensbury before the expiration date.) Wednesday, July 31, 2019DatedattheTownofQueensbury SIGNED BY:for theTown ofQueensbury. Director of Building & Code Enforcement Office Use Oriy Gad &T— 2 1 qADDITION/ALTERATION PERMIT Permit;'t: 7 APPLICATION Permit Fee:$ 6 q J ' Town of Queensbuty 742 Bay Road,Queensbury,NV 12804 invoice#: 764) P:518-761-8256 www.queensbury.net Project Location: 2(p t7 Q n Tax Map ID Subdivision Name: \ A v\ ifi\ CONTACT INFORMATION: E.ENggURY TOWN OF Qu& C°DES Applicant: BUILDING Name(s): ,1M SIM-0114 — ., t4 rt' 105 it4C•• Mailing Address, C/S/Z: 3 t Q -i . 6d4g4S I t' 12So% Cell Phone: ( L"i ) 742.- 0381 Land Line: ( 1$ ) g32— 6 Email: \gin i @,A`-ref. Cowl Prima Owner(s): Name(s): NY6 .FS T 1 rw-(D121 MINg04- Lt lste .'Aol 1) Mailing Address, C/S/Z: (033 figt:, /41 Cell Phone: ) - Land Line: ( I'• ) 3& Email: rwi Ie tc y1n xi • Cowl Contractor(s): Business Name: U\119t re4 `. Contact Name(s): r-t Mailing Address, C/S/Z:ettPs0 Qu S5t4 ( R`( 12$o {- Cell Phone: (6l ) S(01— 2141 Land Line: ( '763 )`713-203 - Email: ` erZe rrzelli»d • cori Architect(s)/Engineer(s): Business Name: 4 L(i Ai 1-1 U1 Contact Name(s): Mailing Address, C/S/Z: ` gpires..1 C S [i ? tZ-gbl Cell Phone: (L113 ) filet) 2f8g Land Line: ( 5)6 ) o2445 Email: ee a1k1&nca.f.y`r"; rDh/1 Contact Person for Building & Code Compliance: t t4 Cell Phone: (E 2 ) 2k0-2.0eS Land Line: ( S ) ( —O24'& Email: erbaLk 11 P•rC'. GdrY1 Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017 1 PROJECT INFORMATION: TYPE:X Commercial Residential WORK CLASS: Single-Family Two-Family Multi-Family (#of units Townhouse X Business Office Retail X Industrial/Warehouse Garage(#of cars Other (describe ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 1st floor: .t t' 'b sir 2nd floor: 2nd floor: I f atw Sr. 3rd floor: 3rd floor: 4th floor: 4th floor: Total square feet: Total square feet: 2b6 sto- ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ 20niere 2. If Commercial project, what is the proposed use: 6t'Oar I 4G 3. Source of Heat(circle one): AV Oil Propane Solar Other' Fireplaces need a separate Fuel Burning Appliances&Chimney Application 4. Are there any structures not shown on the plot plan? YES NO Explain: wp... 5. Are there any easements on the property? YES NO 6. SITE INFORMATION: a. What is the dimensions or acreage of the parcel? kV-8. b. Is this a corner lot? YES 1 D7 c. Will the grade be changed as a result • the construction? YES NO d. What is the water s• ce? PUB PRIVATE WELL e. Is the parcel oor a PRIVATE SEPTIC system? Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017 DECLAl iTIM: I. I acknowledge that no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: VilkAti P4 1112r/rp't 4t20 4 1 SIGNATURE: 4DATE: Ii -11.Y 0/q Town of aueensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017 FIRM: MTI - Mechanical Testing, Inc. 4 Chelsea Place, Suite 102 Clifton Park NY 12065 PHONE: 518) 450-7292 FAX: 518) 450-7295 CUSTOMER: Northern Mechanical Service PROJECT #: 20-387 PROJECT ADDRESS: 276 Dix Avenue Queensbury NY 12804 DATE: 2020-09-01 CONTACT: Erik Jensen Just Goods, Inc. 4 Chelsea Pl, Suite 102 Clifton Park, NY 12065 Phone: 518-450-7292 Fax: 518-450-7295 Design Review - Commissioning - Fire Life Safety - Test And Balance - ASHRAE 110 -Drone Sales/Inspections Terms and Abbreviations ACH- Air Changes per Hour AHU- Air Handling Unit AK- Free Area of Duct AVG- Average BHP- Brake Horsepower BV- Ball Valve (Shut Off Valve) CB- Circuit Breaker CBV- Calibrated Balance Valve CD-Ceiling Diffuser CFM- Cubic Feet per Minute CHWS- Chilled Water System CRAC- Computer Room Air Conditioner CS- Circuit Setter CUH- Cabinet Unit Heater DAT- Discharge Air Temperature DD- Direct Drive (motor) Des.- Design Disch.- Discharge DNE- Does Not Exist DP- Discharge Pressure of Pump/Pressure Drop EA- Exhaust Air EAV- Exhaust Air Valve EAT- Entering Air Temperature EF- Exhaust Fan EG- Exhaust Grille ERU- Energy Recovery Unit E.S.P.- External Static Pressure EWT- Entering Water Temperature FCU- Fan Coil Unit FD- Fire Damper FLA- Full Load Amperage Flow Coeff. –Correction Factor for Flow to VAV Flow Hood- Instrument that measures airflow FPM- Feet per Minute GPM- Gallons Per Minute HEPA- High Efficiency Particulate Arrestance HP- Horsepower HVAC- Heating Ventilation and Air Conditioning HWS- Hot Water System HX- Heat Exchanger Hz- Hertz In.- Inches In. w.g.- Inches of Water Gauge ISDFT- Insufficient Straight Duct for Traverse Kfactor- Correction factor to the free area needed to calculate CFM. LAT- leaving Air Temperature LWT- Leaving Water Temperature MAU- Make Up Air Handling Unit MAX- Maximum set point/flow MIN- Minimum set point/flow NI-Not Installed NIS-Not in Scope O/A- Outside Air OBD- Opposed Blade Damper OD- Outside Diameter Measurement of Sheave PH- Phase PSI- Pounds per Square Inch RA- Return Air RAT- Return Air Temperature RF- Return Fan RHC- Reheat Coil RPM- Revolutions per Minute RTU- Roof Top Unit SA- Supply Air SAV- Supply Air Valve SAT- Supply Air Temperature S.F.- Service Factor SF- Supply Fan SP- Suction Pressure of Pump/ Static Pressure Sq. ft.- Square Feet TAB- Test, Adjust and Balance TDV- Triple Duty Valve TP- Thermally Protected TSP- Total Static Pressure UH- Unit Heater V- Volts VAV- Variable Air Volume Box VD- Volume Damper VFD- Variable Frequency Drive VVT- Variable Volume Terminal WC- Water Column 3 3 4 4 11 Table of Contents Instruments Used Instruments Used AME AHU-1 AHU-2 PROJECT NUMBER: 20-387 CONTACT: Erik Jensen LOCATION: Just Goods, Inc. 276 Dix Avenue Queensbury NY 12804 Page 2 of 16 2020-09-01 Instruments Used Instruments Used AIR Manufacturer Evergreen Calibration Date 8/24/20 Model No.S-PVF-1 Tech Name Erik Jensen Serial No.1500197 WATER Manufacturer Not Applicable Calibration Date not Applicable Model No.not Applicable Tech Name not Applicable Serial No.not Applicable ALTERNATE METER Meter Type Air Serial No.1700324 Manufacturer Evergreen Calibration Date 7/8/20 Model No.S-SPV-1 PROJECT NUMBER: 20-387 CONTACT: Erik Jensen LOCATION: Just Goods, Inc. 276 Dix Avenue Queensbury NY 12804 Instruments Used Page 3 of 16 2020-09-01 Design Actual %Design Actual % AME AHU-1 UNIT DATA Equipment Location Mech Space Filter Type Pleated Area Served Hygiene Filter Quantity 8 Unit Manufacturer Carrier Filter Size 15 3/4 X 23 3/8 X1 3/4 in Unit Model No.40RUSA14T2A5-0A0A0 Performed By EJ Unit Serial No.1220U09592 Pass/Fail See Notes AHU-1 / Test Data* TEST DATA Total Unit CFM 4000 CFM 4008 CFM 100 O/A Damper Position 100% % Outlet CFM 4000 CFM 3949 CFM 99 R/A Damper Position See note % Outside Air CFM 1292 CFM 1070 CFM 83 Discharge Air temp 60 deg F Return Air CFM 2708 CFM 2938 CFM 108 Hertz at Design CFM 52.5 Hz Fan RPM 735 RPM 683 RPM 93 Test Date 8/31/20 NOTES: Test Data R/A Damper Position There is no return damper installed in the unit, the outside air has been determined by subtracting the return flows from the total supply. Unable to further increase the outside airflow. AHU-1 / Motor Data* MOTOR DATA Motor Manufacturer Marathon Volts T1 206.6 Volts PROJECT NUMBER: 20-387 CONTACT: Erik Jensen LOCATION: Just Goods, Inc. 276 Dix Avenue Queensbury NY 12804 AHU-1 Page 4 of 16 2020-09-01 Design Actual %Design Actual % Motor Frame 56HZ Volts T2 205.9 Volts Motor RPM 1735 RPM Volts T3 203.6 Volts Motor Horsepower 2.9 HP Plate Amps 8.1-7.6 Amps Motor Phase 3 Amps T1 4.80 Amps Motor Hertz 60 Hz Amps T2 4.80 Amps Service Factor 1.15 Amps T3 4.80 Amps Efficiency 0.850 Starter Heater VFD Power Factor 0.850 Brake Horsepower 1.662 Plate Volts 208-230 Volts MOTOR DATA NOTES: Motor Data Efficiency The Efficiency and Power Factor are not listed on the motor tag. MTI used the industry standard of 0.85 for each to determine an ESTIMATED BHP. AHU-1 / Drive Data* DRIVE DATA Motor Sheave/OD Size 4 1/2 Fan Bore 1 7/8 in Motor Bore 7/8 in No. of Belts 1 Motor Sheave % Closed 75 %Belt Size A-40 3319MX Fan Sheave/OD Size BK90 Center Distance 11 1/2 in AHU-1 / Test Pressures* TEST PRESSURES Total Static Pressure .79 in. H2O 0.82 in. H2O 104 Pre-Filter DP Not Listed in. H2O . 09 in. H2O External Static Pressure .60 in. H2O 0.60 in. H2O 100 Pre-Heat DP Not Listed in. H2O Not Applicable in. H2O PROJECT NUMBER: 20-387 CONTACT: Erik Jensen LOCATION: Just Goods, Inc. 276 Dix Avenue Queensbury NY 12804 AHU-1 Page 5 of 16 2020-09-01 Design Actual %Design Actual % Discharge Static 0.53 in. H2O Cooling Coil DP Not Listed in. H2O . 20 in. H2O Suction Static 0.29 in. H2O Static at Furthest VAV Not Applicable in. H2O Mix Box/Pre-Filter SP Not Listed in. H2O . 07 in. H2O Sys. Operational Static Not Applicable in. H2O TEST PRESSURES AHU-1 / Photos* PHOTO'S Unit Photo PROJECT NUMBER: 20-387 CONTACT: Erik Jensen LOCATION: Just Goods, Inc. 276 Dix Avenue Queensbury NY 12804 AHU-1 Page 6 of 16 2020-09-01 Photo's IMAGES: AHU-1 / Static Profile STATIC PROFILE Static Profile PROJECT NUMBER: 20-387 CONTACT: Erik Jensen LOCATION: Just Goods, Inc. 276 Dix Avenue Queensbury NY 12804 AHU-1 Page 7 of 16 2020-09-01 IMAGES: PROJECT NUMBER: 20-387 CONTACT: Erik Jensen LOCATION: Just Goods, Inc. 276 Dix Avenue Queensbury NY 12804 AHU-1 Page 8 of 16 2020-09-01 AHU-1 / Traverse Summary TRAVERSE SUMMARY Name System Location Size Area Design FPM Design CFM Average FPM Actual CFM Static Pressure Main Traverse*AHU1 Mech space 18X20 2.500 1600 4000 1603 4008 0.480 Totals 4000 4008 AHU-1 / Supply Outlet Summary PROJECT NUMBER: 20-387 CONTACT: Erik Jensen LOCATION: Just Goods, Inc. 276 Dix Avenue Queensbury NY 12804 AHU-1 Page 9 of 16 2020-09-01 SUPPLY OUTLET SUMMARY Name Room No.Type Size AK Factor Design FPM Design CFM Reading 1 Reading 2 Final CFM % of Design SO-001*Hygiene SG 36x18 3.285 609 2000 660 596 1958 98 SO-002 Hygiene SG 36x18 3.285 609 2000 674 606 1991 100 Totals 4000 3949 AHU-1 / Return Inlet Summary RETURN INLET SUMMARY Name Room No.Type Size AK Factor Design FPM Design CFM Reading 1 Reading 2 Final CFM % of Design RI-001 Hygiene RG 36x18 3.600 376 1354 538 415 1494 110 RI-002 Hygiene RG 36x18 3.600 376 1354 521 401 1444 107 Totals 2708 2938 PROJECT NUMBER: 20-387 CONTACT: Erik Jensen LOCATION: Just Goods, Inc. 276 Dix Avenue Queensbury NY 12804 AHU-1 Page 10 of 16 2020-09-01 Design Actual %Design Actual % AHU-2 UNIT DATA Equipment Location Mech Space Filter Type Pleated Area Served Hygiene Filter Quantity 8 Unit Manufacturer Carrier Filter Size 15 3/4 X 23 3/8 X1 3/4 in Unit Model No.40RUS014 Performed By EJ Unit Serial No.1220U09593 Pass/Fail See Notes AHU-2 / Test Data* TEST DATA Total Unit CFM 4000 CFM 4017 CFM 100 O/A Damper Position 100 % Outlet CFM 4000 CFM 3978 CFM 99 R/A Damper Position See note % Outside Air CFM 1292 CFM 1072 CFM 83 Discharge Air temp 62 deg F Return Air CFM 2708 CFM 2945 CFM 109 Hertz at Design CFM 52.5 Hz Fan RPM 735 RPM 682 RPM 93 Test Date 8/30/20 NOTES: Test Data R/A Damper Position There is no return damper installed in the unit, the outside air has been determined by subtracting the return flows from the total supply. Unable to further increase the outside airflow. AHU-2 / Motor Data* MOTOR DATA Motor Manufacturer Marathon Volts T1 205 Volts Motor Frame 56HZ Volts T2 204 Volts Motor RPM 1735 RPM Volts T3 206 Volts Motor Horsepower 2.9 HP Plate Amps 8.1-7.6 Amps PROJECT NUMBER: 20-387 CONTACT: Erik Jensen LOCATION: Just Goods, Inc. 276 Dix Avenue Queensbury NY 12804 AHU-2 Page 11 of 16 2020-09-01 Design Actual %Design Actual % Motor Phase 3 Amps T1 4.70 Amps Motor Hertz 60 Hz Amps T2 4.70 Amps Service Factor 1.15 Amps T3 4.70 Amps Efficiency 0.850 Starter Heater VFD Power Factor 0.850 Brake Horsepower 1.614 Plate Volts 208-230 Volts MOTOR DATA NOTES: Motor Data Efficiency The Efficiency and Power Factor are not listed on the motor tag. MTI used the industry standard of 0.85 for each to determine an ESTIMATED BHP. AHU-2 / Drive Data* DRIVE DATA Motor Sheave/OD Size 4 1/2 Fan Bore 1 7/8 in Motor Bore 7/8 in No. of Belts 1 Motor Sheave % Closed 75 %Belt Size A-40 3319MX Fan Sheave/OD Size BK90 Center Distance 11.5 in AHU-2 / Test Pressures* TEST PRESSURES Total Static Pressure 0.79 in. H2O 0.82 in. H2O 104 Pre-Filter DP Not Listed in. H2O 0.08 in. H2O External Static Pressure 0.60 in. H2O 0.57 in. H2O 95 Pre-Heat DP Not Listed in. H2O Not Applicable in. H2O Discharge Static 0.49 in. H2O Cooling Coil DP Not Listed in. H2O 0.17 in. H2O Suction Static 0.33 in. H2O Static at Furthest VAV Not Applicable in. H2O PROJECT NUMBER: 20-387 CONTACT: Erik Jensen LOCATION: Just Goods, Inc. 276 Dix Avenue Queensbury NY 12804 AHU-2 Page 12 of 16 2020-09-01 Design Actual %Design Actual % Photo's Mix Box/Pre-Filter SP Not Listed in. H2O . 08 in. H2O Sys. Operational Static Not Applicable in. H2O TEST PRESSURES AHU-2 / Photos* PHOTO'S Unit Photo IMAGES: AHU-2 / Static Profile PROJECT NUMBER: 20-387 CONTACT: Erik Jensen LOCATION: Just Goods, Inc. 276 Dix Avenue Queensbury NY 12804 AHU-2 Page 13 of 16 2020-09-01 STATIC PROFILE Static Profile IMAGES: PROJECT NUMBER: 20-387 CONTACT: Erik Jensen LOCATION: Just Goods, Inc. 276 Dix Avenue Queensbury NY 12804 AHU-2 Page 14 of 16 2020-09-01 AHU-2 / Traverse Summary TRAVERSE SUMMARY Name System Location Size Area Design FPM Design CFM Average FPM Actual CFM Static Pressure Main Traverse*AHU2 Mech room 18x20 2.500 1600 4000 1607 4018 0.460 Totals 4000 4018 AHU-2 / Supply Outlet Summary PROJECT NUMBER: 20-387 CONTACT: Erik Jensen LOCATION: Just Goods, Inc. 276 Dix Avenue Queensbury NY 12804 AHU-2 Page 15 of 16 2020-09-01 SUPPLY OUTLET SUMMARY Name Room No.Type Size AK Factor Design FPM Design CFM Reading 1 Reading 2 Final CFM % of Design SO-001 Hygiene SG 36x18 3.285 609 2000 613 613 2014 101 SO-002 Hygiene SG 36x18 3.285 609 2000 598 598 1964 98 Totals 4000 3978 AHU-2 / Return Inlet Summary RETURN INLET SUMMARY Name Room No.Type Size AK Factor Design FPM Design CFM Reading 1 Reading 2 Final CFM % of Design RI-001 Hygiene RG 36x12 3.600 376 1354 438 412 1483 110 RI-002 Hygiene RG 36x12 3.600 376 1354 381 406 1462 108 Totals 2708 2945 PROJECT NUMBER: 20-387 CONTACT: Erik Jensen LOCATION: Just Goods, Inc. 276 Dix Avenue Queensbury NY 12804 AHU-2 Page 16 of 16 2020-09-01 fiCOMcheck Software Version 4.1.1.0 l Interior Lighting Compliance Certificate Project Information oPEnergyCode:2015 IECC Y Project Title: Renovations to 276 Dix Ave for JUST Goods Project Type:Alteration Construction Site:Owner/Agent: Designer/Contractor: 276 Dix Ave NYS Job Development Corp Ethan P. Hall Queensbury, NY 12804 633 Third Ave Rucinski Hall Architecture New York, NY 10017 134 Dix Ave Glens Falls, NY 12801 518-741-0268 ephall@nycap.rr.com Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts ft2) Watts/ft2 B X C) 1-Common Space Types:Office-Enclosed 1444 1.11 1603 2-Common Space Types:Restrooms 481 0.98 471 3-Common Space Types:Office-Open Plan 975 0.98 956 Total Allowed Watts= 3030 Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Common Space Types:Office- Enclosed (1444 sa.ft.) LED 1: LED Panel 40W: 1 24 40 960 Common Space Types:Restrooms(481 sq.ft.) LED 2: LED Panel 40W 1 7 40 280 Common Space Types:Office-Open Plan(975 sq.ft.) LED 3: LED Panel 40W: 1 17 40 680 Total Proposed Watts= 1920 Interior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in CO check Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection cklist. Ethan P. Hall-Architect JutY ZO/47 Name-Title Si ure Date Project Title: Renovations to 276 Dix Ave for JUST Goods Report date: 07/25/19 Data filename: Y:\Rozell Industries\JUST Beverages\276 Dix Ave\276 Dix Ave.cck Page 1 of 13 COMcheck Software Version 4.1.1.0 Afil Exterior Lighting Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: Renovations to 276 Dix Ave for JUST Goods Project Type:Alteration Exterior Lighting Zone 2(Neighborhood business district) Construction Site: Owner/Agent: Designer/Contractor: 276 Dix Ave NYS Job Development Corp Ethan P. Hall Queensbury, NY 12804 633 Third Ave Rucinski Hall Architecture New York, NY 10017 134 Dix Ave Glens Falls, NY 12801 518-741-0268 ephall@nycap.rr.com Allowed Exterior Lighting Power A B C D E Area/Surface Category Quantity Allowed Tradable Allowed Watts Watts/Unit Wattage B X C) Entry canopy 1 ft2 0.25 Yes 0 Total Tradable Watts(a)= 0 Total Allowed Watts= 0 Total Allowed Supplemental Watts(b)= 600 a)Wattage tradeoffs are only allowed between tradable areas/surfaces. b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Entry canopy(1 ft2):Tradable Wattage LED 1:LED Linear 20W: 1 1 40 40 Total Tradable Proposed Watts= 40 Exterior Lighting PASSES Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed exterior lighting systems have been designed to meet the 2015 IECC requirements in COMchec Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection klist. Ethan P.Hall-Architect 2Lj UI.4 49/47 Name-Title Sig ture Date Project Title: Renovations to 276 Dix Ave for JUST Goods Report date: 07/25/19 Data filename: Y:\Rozell Industries\JUST Beverages\276 Dix Ave\276 Dix Ave.cck Page 2 of 13 COMcheck Software Version 4.1.1.0 Nfil Mechanical Compliance Certificate Project Information Energy Code:2015 IECC Project Title: Renovations to 276 Dix Ave for JUST Goods Location: Glens Falls, New York Climate Zone: 6a Project Type:Alteration Construction Site:Owner/Agent: Designer/Contractor: 276 Dix Ave NYS Job Development Corp Ethan P. Hall Queensbury, NY 12804 633 Third Ave Rucinski Hall Architecture New York, NY 10017 134 Dix Ave Glens Falls, NY 12801 518-741-0268 ephall@nycap.rr.com Mechanical Systems List Quantity System Type&Description 1 HVAC System 1 (Single Zone): Heating: 1 each-Central Furnace,Gas,Capacity=65 kBtu/h Proposed Efficiency=95.00%Et,Required Efficiency: 80.00%Et or 78%AFUE Cooling: 1 each-Field-Assembled DX System,Capacity=45 kBtu/h,Air-Cooled Condenser,Air Economizer No minimum efficiency requirement applies Fan System: FAN SYSTEM 1 —Compliance(Motor nameplate HP method):Fails:Fan system has no supply fan Fans: FAN 1 Return,Constant Volume, 1977 CFM, 1.0 motor nameplate hp,0.0 fan efficiency grade Mechanical Compliance Statement Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2015 IECC requirements in COMcheck rsion 4.1. 0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. 2.G Ethan P. Hall-Architect G.V Name-Title Si ature Date Project Title: Renovations to 276 Dix Ave for JUST Goods Report date: 07/25/19 Data filename: Y:\Rozell Industries\JUST Beverages\276 Dix Ave\276 Dix Ave.cck Page 3 of 13 COMcheck Software Version 4.1.1.0 11 Inspection Checklist Energy Code: 2015 IECC Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plan Review Complies? Comments/Assumptions Re..ID C103.2 Plans, specifications, and/or EComplies Requirement will be met. PR2]' calculations provide all information Does Not with which compliance can be Not Observable Location on plans/spec: HVAC-1determinedforthemechanical systems and equipment and Not Applicable document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. C103.2 Plans, specifications, and/or Complies ;Requirement will be met. PR4]i calculations provide all information Does Not with which compliance can be Location on plans/spec: A-i determined for the interior lighting ENot Observable and electrical systems and equipment ENot Applicable and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts,transformers and ' control devices. C103.2 Plans, specifications, and/or Complies ;Requirement will be met. PR8]1 calculations provide all information Does Not with which compliance can be 1Location on plans/spec: A-1 determined for the exterior lighting [' Not Observable' and electrical systems and equipment ENot Applicable and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 JMedium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Renovations to 276 Dix Ave for JUST Goods Report date: 07/25/19 Data filename: Y:\Rozell Industries\JUST Beverages\276 Dix Ave\276 Dix Ave.cck Page 4 of 13 Section Footing/ Foundation Inspection Complies? Comments/Assumptions Req.ID C403.2.4. Snow/ice melting system sensors for Complies Exception: Requirement does not apply. 5, future connection to controls. Freeze Does Not C403.2.4. protection systems have automatic 6 controls installed.Not Observable FO9]3 Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 I Low Impact(Tier 3) Project Title: Renovations to 276 Dix Ave for JUST Goods Report date: 07/25/19 Data filename: Y:\Rozell Industries\JUST Beverages\276 Dix Ave\276 Dix Ave.cck Page 5 of 13 Section Plumbing Rough-In Inspection Complies? Comments/Assumptions Req.ID C404.5, Heated water supply piping conforms Complies Exception: Requirement does not apply. C404.5.1, to pipe length and volume Does Not C404.5.2 requirements. Refer to section details. PL6]3 Not Observable Not Applicable C404.6.3 Pumps that circulate water between a Complies Exception: Requirement does not apply. PL7]3 heater and storage tank have controls Oboes Not that limit operation from startup to 5 minutes after end of heating Not Observable cycle. Not Applicable C404.7 Water distribution system that pumps Complies Exception: Requirement does not apply. PL8]3 water from a heated-water supply Does Not pipe back to the heated-water source through a cold-water supply pipe is a Not Observable demand recirculation water system. Not Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 'Low Impact(Tier 3) Project Title: Renovations to 276 Dix Ave for JUST Goods Report date: 07/25/19 Data filename: Y:\Rozell Industries\JUST Beverages\276 Dix Ave\276 Dix Ave.cck Page 6 of 13 Section Mechanical Rough-In Inspection Complies? Comments/Assumptions Req.ID C402.2.6 Thermally ineffective panel surfaces of EComplies Exception: Requirement does not apply. ME41]3 sensible heating panels have Does Not insulation >= R-3.5. Not Observable Not Applicable C403.2.13 Unenclosed spaces that are heated EComplies Exception: Requirement does not apply. ME71]2 use only radiant heat. Does Not Not Observable Not Applicable C403.2.3 HVAC equipment efficiency verified. EComplies See the Mechanical Systems list for values. ME55)2 Does Not Not Observable Not Applicable C403.2.6. Demand control ventilation provided EComplies Exception: Requirement does not apply. 1 for spaces >500 ft2 and >25 Does Not ME59)1 people/1000 ft2 occupant density and served by systems with air side Not Observable economizer, auto modulating outside ENot Applicable air damper control, or design airflow 3,000 cfm. C403.2.6. Enclosed parking garage ventilation Complies Exception: Requirement does not apply. 2 has automatic contaminant detection Does Not ME115]3 and capacity to stage or modulate fans to 50%or less of design capacity. Not Observable Not Applicable C403.2.7 Exhaust air energy recovery on Complies Requirement will be met. ME57]1 systems meeting Table C403.2.7(1) Does Not and C403.2.7(2). Not Observable Not Applicable C403.2.8 Kitchen exhaust systems comply with Complies Exception: Requirement does not apply. ME116]3 replacement air and conditioned Does Not supply air limitations, and satisfy hood rating requirements and maximum Not Observable exhaust rate criteria. Not Applicable C403.2.9 HVAC ducts and plenums insulated. EComplies Exception: Requirement does not apply. ME60]2 Where ducts or plenums are installed Does Not in or under a slab, verification may need to occur during Foundation Not Observable Inspection. Not Applicable C403.2.9 Ducts and plenums sealed based on 'Complies Requirement will be met. ME10]2 static pressure and location. EDoes Not Not Observable Location on plans/spec: HVAC-1 Not Applicable C403.2.9. Ductwork operating >3 in. water Complies Exception: Requirement does not apply. 1.3 column requires air leakage testing. Does Not ME11]3 Not Observable Not Applicable C403.4.4. Multiple zone VAV systems with DDC EComplies Exception: Requirement does not apply. 6 of individual zone boxes have static Does Not ME110]3 pressure setpoint reset controls. Not Observable See the Mechanical Systems list for values. Not Applicable C408.2.2. Air outlets and zone terminal devices EComplies Requirement will be met. 1 have means for air balancing. Does Not ME53]3 Location on plans/spec: HVAC-1NotObservable Not Applicable 1 High Impact(Tier 1) i 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Renovations to 276 Dix Ave for JUST Goods Report date: 07/25/19 Data filename: Y:\Rozell Industries\JUST Beverages\276 Dix Ave\276 Dix Ave.cck Page 7 of 13 Section Mechanical Rough-In Inspection Complies? Comments/Assumptions Req.ID C403.5, Refrigerated display cases, walk-in Complies Exception: Requirement does not apply. C403.5.1, coolers or walk-in freezers served by Does Not C403.5.2 remote compressors and remote ME123]3 condensers not located in a Not Observable condensing unit, have fan-powered Not Applicable condensers that comply with Sections C403.5.1 and refrigeration compressor systems that comply with C403.5.2.. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 13 I Low Impact(Tier 3) Project Title: Renovations to 276 Dix Ave for JUST Goods Report date: 07/25/19 Data filename: Y:\Rozell Industries\JUST Beverages\276 Dix Ave\276 Dix Ave.cck Page 8 of 13 Section Rough-In Electrical Inspection Complies? Comments/Assumptions Re..ID C405.2.1 Lighting controls installed to uniformly Complies Requirement will be met. EL15]1 reduce the lighting load by at least Does Not 50%. Location on plans/spec:A-1DNotObservable ONot Applicable C405.2.1 Occupancy sensors installed in Complies Requirement will be met. EL18]1 required spaces. Does Not Not Observable Location on plans/spec:A-1 ONot Applicable C405.2.1, Independent lighting controls installed Complies Requirement will be met. C405.2.2. per approved lighting plans and all ODoes Not 3 manual controls readily accessible and :Not Observable Location on plans/spec:A-1EL23]2 visible to occupants. ONot Applicable C405.2.2. Automatic controls to shut off all Complies Requirement will be met. 1 building lighting installed in all DDoes Not EL22]2 buildings. Location on plans/spec:A-1NotObservable ONot Applicable C405.2.3 Daylight zones provided with Complies Exception: Requirement does not apply. EL16]2 individual controls that control the ODoes Not lights independent of general area lighting. Not Observable ONot Applicable C405.2.3, Primary sidelighted areas are Complies Exception: Requirement does not apply. C405.2.3. equipped with required lighting ODoes Not 1, controls. C405.2.3. DNot Observable 2 ONot Applicable EL20]1 C405.2.3, Enclosed spaces with daylight area Complies Exception: Requirement does not apply. C405.2.3. under skylights and rooftop monitors ODoes Not 1, are equipped with required lighting C405.2.3. controls. ONot Observable 3 ONot Applicable EL21]1 C405.2.4 Separate lighting control devices for Complies Requirement will be met. EL4]1 specific uses installed per approved ODoes Not lighting plans. Location on plans/spec:A-1NotObservable ONot Applicable C405.2.4 Additional interior lighting power Complies Requirement will be met. EL8]1 allowed for special functions per the ODoes Not approved lighting plans and is Not Observable Location on plans/spec:A-1automaticallycontrolledand separated from general lighting.ONot Applicable C405.2.5 Automatic lighting controls for exterior Complies Exception: Requirement does not apply. EL25]1 lighting installed.Controls will be ODoes Not daylight controlled, set based on business operation time-of-day, or ONot Observable reduce connected lighting > 30%. ONot Applicable C405.3 Exit signs do not exceed 5 watts per Complies Requirement will be met. EL6]1 face. ODoes Not DNot Observable Location on plans/spec:A-1 ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 1 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Renovations to 276 Dix Ave for JUST Goods Report date: 07/25/19 Data filename: Y:\Rozell Industries\JUST Beverages\276 Dix Ave\276 Dix Ave.cck Page 9 of 13 1 High Impact (Tier 1) 2 Medium Impact(Tier 2) 13 I Low Impact(Tier 3) Project Title: Renovations to 276 Dix Ave for JUST Goods Report date: 07/25/19 Data filename: Y:\Rozell Industries\JUST Beverages\276 Dix Ave\276 Dix Ave.cck Page 10 of 13 Section Final Inspection Complies? Comments/Assumptions Re..ID C303.3, Furnished O&M instructions for EComplies Requirement will be met. C408.2.5. systems and equipment to the Does Not 2 building owner or designated F117]3 representative. ENot Observable Not Applicable C303.3, Furnished O&M manuals for HVAC Complies Requirement will be met. C408.2.5. systems within 90 days of system 'Does Not 3 acceptance. F18]3 Not Observable Not Applicable C403.2.2 HVAC systems and equipment EComplies Requirement will be met. F127]3 capacity does not exceed calculated Does Not loads. Location on plans/spec: HVAC-1ENotObservable Not Applicable C403.2.4. Heating and cooling to each zone is EComplies Requirement will be met. 1 controlled by a thermostat control. EDoes Not F147]3 Minimum one humidity control device [Not Observable Location on plans/spec: HVAC-1perinstalled humidification/dehumidification Not Applicable system. C403.2.4. Thermostatic controls have a 5 °F Complies Requirement will be met. 1.2 deadband.EDoes Not F138)3 Location on plans/spec: HVAC-1ENotObservable Not Applicable C403.2.4. Temperature controls have setpoint EComplies Exception: Requirement does not apply. 1.3 overlap restrictions. ODoes Not F120)3 ENot Observable Not Applicable C403.2.4. Each zone equipped with setback EComplies Exception: Requirement does not apply. 2 controls using automatic time clock or Does Not F139]3 programmable control system.Not Observable Not Applicable C403.2.4. Automatic Controls: Setback to 55°F EComplies Exception: Requirement does not apply. 2.1,heat) and 85°F (cool); 7-day clock, 2- EDoes Not C403.2.4. hour occupant override, 10-hour 2.2 backup Not Observable F140]3 ENot Applicable C405.4.1 Interior installed lamp and fixture ElComplies See the Interior Lighting fixture schedule for values. F118]1 lighting power is consistent with what EDoes Not is shown on the approved lighting plans, demonstrating proposed watts ENot Observable are less than or equal to allowed ENot Applicable watts. C405.5.1 Exterior lighting power is consistent Complies See the Exterior Lighting fixture schedule for values. F119]1 with what is shown on the approved EDoes Not lighting plans, demonstrating proposed watts are less than or equal ENot Observable to allowed watts. Not Applicable 1C408.2.1 Commissioning plan developed by EComplies Requirement will be met. 1[F128]1 registered design professional or Does Not approved agency. Location on plans/spec: HVAC-1ENotObservable Not Applicable C408.2.3. HVAC equipment has been tested to Complies Requirement will be met. 1 ensure proper operation.EDoes Not F131]1 Location on plans/spec: HVAC-1NotObservable Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Renovations to 276 Dix Ave for JUST Goods Report date: 07/25/19 Data filename: Y:\Rozell Industries\JUST Beverages\276 Dix Ave\276 Dix Ave.cck Page 11 of 13 Section Final Inspection Complies? Comments/Assumptions Re..ID C408.2.3. HVAC control systems have been Complies Requirement will be met. 2 tested to ensure proper operation, Does Not FI10]' calibration and adjustment of controls. Not Observable Location on plans/spec: HVAC-1 ONot Applicable C408.2.4 Preliminary commissioning report Complies Requirement will be met. F129]' completed and certified by registered Does Not design professional or approved Not Observable Location on plans/spec: HVAC-1 agency. Not Applicable C408.2.5. Furnished HVAC as-built drawings Complies Requirement will be met. 1 submitted within 90 days of system Does Not FI7]3 acceptance. Not Observable Not Applicable C408.2.5. Furnished as-built drawings for Complies Requirement will be met. 1 electric power systems within 90 days EDoes Not F116]3 of system acceptance. ENot Observable Not Applicable C408.2.5. An air and/or hydronic system EComplies Requirement will be met. 3 balancing report is provided for HVAC Does Not F143]' systems. Location on plans/spec: HVAC-1 Not Observable Not Applicable C408.2.5. Final commissioning report due to Complies ;Requirement will be met. 4 building owner within 90 days of Does Not F130]' receipt of certificate of occupancy. Not Observable Location on plans/spec: HVAC-1 Not Applicable C408.3 Lighting systems have been tested to Complies Requirement will be met. F133]1 ensure proper calibration, adjustment, Does Not programming, and operation. Not Observable Location on plans/spec:A-1 Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 13 Low Impact(Tier 3) Project Title: Renovations to 276 Dix Ave for JUST Goods Report date: 07/25/19 Data filename: Y:\Rozell Industries\JUST Beverages\276 Dix Ave\276 Dix Ave.cck Page 12 of 13 Project Title: Renovations to 276 Dix Ave for JUST Goods Report date: 07/25/19 Data filename: Y:\Rozell Industries\JUST Beverages\276 Dix Ave\276 Dix Ave.cck Page 13 of 13 Page 1 Northern Mechanical Services 30 Progress Blvd. Queensbury N.Y. 12804 Y518)745-1537 FILE COPYO] Dbrambley®northemmechservices.com Just Goods 276 Dix Ave. Queensbury N.Y. 12804 July 22, 2019 Attention: Ethan Hall H.V.A.C. scope of work: Install Natural gas fired furnace 80,000 BTUH Install Condenser Outdoor unit 3.5 ton Install associated refrigeration piping Install HRV for fresh air requirement and bathroom exhaust Install supply and return air duct system with balancing dampers Insulate duct as required Install grilles and registers Install programmable thermostat Certified balance report (By Mechanical Testing Inc.) Install stand alone cooling only system for IT server room (size to match load) Low ambient operation Startup and checkout system operation Northern Mechanical Services. FIRE MARSHAL’S OFFICE Town of Queensbury 742 Bay Road,Queensbury,NY 12804 Home of Natural Beauty...A Good Place to Live” PLAN REVIEW Just Water 276 Dix Avenue CC-0468-2019 7/19/2019 Plan Review The following comments are based on review of drawings: Sprinkler system inspection required,with NFPA 13 letter of compliance for any modifications Knox Box required at new sprinkler door,and keys for existing Knox Box Fire alarm plans shall be submitted ,and need to include as a minimum: Sprinkler monitoring HVAC shutdown and notification if required Central station monitoring Verify fire extinguisher locations Function test all exit /EL fixtures Locks /Latches shall comply w/Chapter 10 of the IFC.No key or thumb turn devices accepted Carbon Monoxide detection required wre —s Michael J Palnier Fire Marshal 742 Bay Road Queensbury NY 12804 firemarshal@queensbury.net Fire Marshal's Office *Phome:518-761-8206 *Fax:518-745-4437 firemarshal@queensbury.net +www.queensbury.net HECEIVER||FLeECoPY Specifications A i 350D¢5] UJ {JUL IU 20FLIFEBREATH-Penronnance aw TOWN OF QUEENSBURY |Seemi.cones BUILDING &CODES,esp ces‘Two modular (two section)aluminum HRV Cores arranged for high efficiency cross-fiow ventilation.|@ 0.1"(25 Pa)450 (212)MOTORS @ 0.2"(50 Pa)426=(201)Meo ss ne e018 Avena ney wind|6°22 om)Prisas 2 ae gor csr)2 08)fear 50 cn (0 te don ak remnbx mocevases|GUS TeEomSenateScatana@0.7"(175 Pa)269 (127)SREest a spa se 07 .75r =eer pescinesaeetaeseetcteeasesCaaS(11049) VAC @ 6oHZ en)Eee oetn meee2SRSnsmartcatesgbeokodnpesmnbedsrene[WATS/HG CelOoeoeaeeOemeeaeeyfallfacedinsulationductlinerwhererequiredtopreventexteriorcondensation.One drain‘ connection 1/2"(12 mm)OD, ELECTRONICS Tmegrated microprocessor circuit board.Built-in interlock contacts, CONTROL OPTIONS 99-DXPLO2 Lifebreath Digital Control (ncuded) 5 speed operation on each mode Humiity contro throughadjustableDehumiastat 5 ser selectable operational modes:Continuous Ventation,Continuous Recirculation,20 ON/40 OFF,10 ON/50 OFF,20 ON/40 Recirculation 99-8003 Lifebreath Ventilation Control Continuous Low fan speed Humidity control through acjustable Dehumicistat 3 modes of operation:Ventilation, Recirculation,20/40 Compatible with 99-DETO2 Wireless 20/40/60 min.High speed averide Timers button =wire connection Compatible wit 9-DETO2 Wireless 99-8C04 Lifebreath VentilationControlimers2speedfansetting (Low High) 2 modes of operation:Ventilation,20/40 Compatible wath 99-DETO2 Wireless 3 wire connecton 99-BC02 Lifebreath Ventilation Control 2 speed fan setting (Low/High)een+ Humidty conto vough agjstable +3 yeconectionDehumiistat99-DHO%Lifebreath Dehumidistat+ Compative wth 99-06T02 Wieess ‘+Humidty contol throughadjustableTimersBehumasat3wieconnection TIMER OPTIONS 3 ie connection 99-DETO1 Lifebreath 20/40/60 Minute Timer Inites High speed Ventlation for 20,40 or 60 minutes.3 wire connection, 99-DETO2 Lifebreath WIRELESS 20/40/60 Minute Timer -Initiates High speed Ventilation for 20,40 or 60 minutes. Wiretessy connects to main contra fr ease of installation.40 approximate range. 99-RKO2 _Lifebreath WIRELESS Repeater -Used to extend range of 99-DETO2 Wireless Timers,Plugs into 120V gower‘ outlet.Wirelessly connects to main control and 99-DETO2.Install a halfway point between timer if timer is out of range.gos am AisconformetersSodas Nore:aspecications are Sbjct toangevitenoteandmainwallcontrol, DIMENSTONS inches (mmm) iz a] tinOTL eter}|eter ey,Fem im“ yer ean ayer Contractor:Now Hye,Servis swnle:Esal we uote: Engineer:Submitted by: NAS _ 155 MAX 4 HEAT RECOVERY VENTILATOR 11 al ENGINEERING DATA LIFEBREHTH 1110 THERMALLY CONDUCTIVE,PATENTED DEFROST I ALUMINUM CORE Recirculating damper defrost system. The counter-flow heat recovery core transfers heat between the two airstreams.It is easily removed for cleaning or service. CASE Twenty gauge prepainted galvanized steel for superior corrosion resistance.Insulated to MOTORS AND BLOWERS prevent exterior condensation.Drain connections 2-1/2 in.(12 mm)0D.Balancing ports Each airstream has one centrifugal blower driven by a common PSC motor,with multiple are located on door. fan speed operations. ELECTRONICS FILTERS The DXPLO2 control included with the unit can be wall mounted in a central location of Washable air filters in exhaust and supply air streams. the home.3 wire 20 gauge(min.)100 tt length(max,). MOUNTING Four threaded inserts at corners of the cabinet designed to accept the"s"hooks and WARRANTY hanging straps supplied with the unit. Units carry a lifetime warranty on the HRV core and a 5 year replacement parts warranty. OPTIONAL ACCESSORIES: Weather Hood Te- EA ille 99 Terminator Wireless 20/40/60 99-185 99 G4 99-FAGS Fitting Min Timer 99 DET0299-186 99 EAG6 99-TM4 99-187 99 EAGB 99 TMS 99-TM6 LIFEBREATH CONTROL OPTIONS TIMER OPTIONS 99-DET01-Lifebreath 20/40/60 Minute Timer FEATURES 99-DXPLO2 99-BCO2 99-BC03 99-BC04 Initiates high speed Ventilation for 20,40 or 60 5 speed fan operation on each mode minutes.3 wire connection. 99-DET02 2 speed fan operation(Low/High) Wireless Lifebreath 20/40/60 Minute Timer Continuous low speed fan operation Initiates high speed Ventilation for 20.40 or 60 minutes.Wirelessly connects to main control for Humidity control through adjustable Dehumidistat ease of installation.40'approximate range. Excusive to Lifebreath. Large digital LCD screen it 99-RX02-Wireless Lifebreath Repeater LED status indicator lights Extends range of 99-DET02 Wireless Timers.Plugs into 120V power outlet.Wirelessly connects to Continuous Ventilation main control and 99-DET02,Install at halfway point between timer and main wall control if timer Continuous Recirculation is out of range. 20 ON/40 OFF I 10 0N/50 OFF u_ 20 ON/40 Recirculation V V 20/40/60 min.High speed override button 99-DXPLO2 99-DET02 Compatible with 99-DET02 Wireless Timer V is 3 wire connection I V L IFEBRERTH' I' indoor Air Systems 155MAX(01-01-18) www.lifebreath.com t S; 155 MAX HEAT RECOVERY VENTILATOR r. PERFORMANCE (HVI CERTIFIED) LIFEofBRERTH 1 1 0.1(25) 0.2(50) 0.3(75) 0.4(100) 0.5(125) 0.6(150) 0.7(175) ELECTRICAL SPECIFICATIONS IN.W.G.(PA) [ FM(Lis) CFM(L/s) CFM(L/s) CFM(Lis) CFM(L's) CFM(L,$) CFM(Vs) I VAC @ 60Hz 115 Net Supply Airflow 184(87) 163(17) 146(69) 132(62) 115(54) 92(43) 60(28) Watts/Low Speed 66 Gross Supply Airflow 188(87) 166(78) 149(70) 134(63) 117(55) 94(44) 61(29) Watts/High Speed 118 Gross Exhaust Airflow 239(113) 228(107) 212(100) 193(91) 172(81) 150(71) 126(60) Amp Rating 1.4 Sensible Effectiveness(ASE) 32°F(0°C) 84% 180 WEIGHT: @ 59 CFM(28 Us) 71 LBS(32 KG) Sensible Efficiency(SRE) 160 32°F ° 75% SHIPPING WEIGHT: @ 59 CFM(28 Us) E 140 73 LBS(33 KG) Sensible Efficiency(SRE) 32°F(0°C) ::: @64 CFM(30Us) 120 0 Sensible Efficiency(SRE) 13°F(25°C) too NOTE: @ 64 CFM(30 Us) a Front clearance of 25 in.(635 mm)is Bo recommended for servicing unit All ducts C use 6 in.(152 min)round collars.Balancing V V I' 90O o HRAI so dampers are located in all air streams. cs w CERTIFIED usisrrnro 11111111 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.13 Static Pressure(in w.g.) DIMENSIONS FRONT VIEW TOP VIEW I Fitter 14 3/41143/41^IRecirculating Defrost " r 1 ( 1 I I Damper 11111111 ._ C A . 11"Removable 11 Blower ReHeatcovery `,/ E Stale air to outsideMotor Coe i e Ti Fresh air from outside Stale air from inside Ali II Ilak MO Fresh air to inside lii 6Roin. un(152dCollarsnlm) I, — 33 5/8In.(854 mini — ,I v v Date: WARRANTY Contractor. Units carry a lifetime warranty Tag:on the HRV core and a 5 year replacement parts warranty. Project' Qty:Supplier: Engineer Quote#: All units conform to CSA and UL standards 1 Control: Submitted By: L/FEBREfTH- I. Indoor Air Systems Timer: Timer Uty: 1S5MAX(01-01-1B) www.lifehreath.com 400991-YTG-K-1018 JYORK® DESCRIPTION These compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applications. These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and TECHNICAL GUIDE are also ideal for commercial applications.All units are factory assembled, wired and tested to assure safe dependable and 95.0%AFUE STANDARD PSC SINGLE economical installation and operation. STAGE MULTI-POSITION RESIDENTIAL These units are Category IV, National Fuel Gas Code and may GAS FURNACES be vented either through side wall or roof applications using approved plastic combustion air and vent piping. Approved MODELS: TG9S plastic combustion air and vent piping include Selkirk Polyflue, NATURAL GAS Duravent Polypro, & Centrotherm Innoflue polypropylene vent- 40-130 MBH INPUT ing systems. FEATURES Easily applied in upflow, horizontal left or right, or downflow installation with minimal conversion necessary. Compact, easy to install, ideal height 33"tall cabinet. YORK Blower-off delay for cooling SEER improvement. Easy access to controls to connect power/control wiring. Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable opera- i tion. Low unit amp requirement for easy replacement applica- tion. 11Pi Single wire twinning or staging feature available. All models are convertible to use propane(LP)gas. polyflue Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability. 100%shut off main gas valve for extra safety. 4 speed, direct drive PSC motor. 24V, 40 VA control transformer and blower relay supplied 0 010.*`°`°"• for add-on cooling.ran al CERTIFIED„ GoorlHousekeeping R Promises Hi-tech tubular aluminized steel primary heat exchanger.P4hbrt JF°D°m ll of PA Vit Part 430 Secondary heat exchanger made of corrosion resistant AMERICAN stainless steel materials. QUALITY Timed on, adjustable off blower capability for maximum ES GN DESIGNED.ENGINEERED 07\ comfort. ASSEMBLED IN THE USA REuiSCSR Blower door safety switch. ISO 9001 Solid removable bottom panel allows easy conversion. Certified Quality Airflow leakage less than 1%of nominal airflow at duct per-Management System formance testing conditions.Due to continuous product improvement,specifications No knockouts to deal with, making installation easier.are subject to change without notice. Visit us on the web at Movable duct connector flanges for application flexibility. www.upgnet.com and www.york.com Quiet inducer operation. Additional rating information can be found at Inducer rotates for easy conversion of venting options. Fully supported blower assembly for easy access and www.ahridirectory.orq removal of blower. WARRANTY SUMMARY External air filters used for maximum flexibility in meeting customers IAQ needs. A 20-year limited warranty on heat exchangers in residen- • Protection included from air intake, exhaust vent, or con- tial applications. densate blockage. A 10-year warranty on the heat exchanger in commercial • No special vent termination required. applications. 1/4 turn knobs provided for easy door removal. Standard 5-year limited Parts warranty. Internal condensate trap design (patent pending) provides Extended lifetime heat exchanger and 10-year limited condensate management options and is self-priming to parts warranty when product is registered online prevent nuisance problems. within 90 days of purchase for replacement or closing • Venting applications - may be installed as either 2-pipefornewhomeconstruction. sealed combustion)or single-pipe vent(using indoor corn- See Limited Warranty certificate in Users Information Manual for details. bustion air). FOR DISTRIBUTION USE ONLY-NOT TO BE USED AT POINT OF RETAIL SALE 400991-YTG-K-1018 LEFT SIDE FRONT RIGHT SIDE Combustion Air Inlet Combustion Air Inlet o i Condensate Drain Gas Pipe Downflow) Entry Gas Pipe .Condensate Drain Entry 'bo4'-(Downflow) Vent Outlet-O Electrical Entry Electrical o Condensate O Entry Vent Outlet Drain tD CD 33 Condensate-.o • r o, m a) Drain C r 0 11 23" N- 1 iThermostatnnn Wirin O II IIgThermostat Wiring Optional Return it Cutout(Either side) Ul U 11 14" f1"4 1T o t I/ 28.5" 29.5" I' -A-'I 1.5"-0II47-f 56 23.8" 3" nt fi I utlOOutlet B Combustion 8 g Air Inlet C 56" .56" 20"t 14 - 24.25" SUPPLY END RETURN END Cabinet&Duct Dimensions Nominal Cabinet Cabinet Dimensions(Inches) Approximate Models CFM(mz/min) Size Operating Weights A B C Lbs TG9SO40A08MP11 800 A 14 1/2 13 3/8 11 3/4 113 TG9S060A1 OMP11 1000 A 14 1/2 13 3/8 11 3/4 118 TG9S060B12MP11 1200 B 17 1/2 16 3/8 131/4 122 TG9S080612MP11 1200 B 17 1/2 16 3/8 14 3/4 126 TG9S080C16MP11 1600 C 21 19 7/8 16 1/2 136 TG9S080C22MP11 2200 C 21 19 7/8 16 1/2 139 TG9S100C16MP11 1600 C 21 19 7/8 18 1/4 142 TG9S100C2OMP11 2000 C 21 19 7/8 18 1/4 145 TG9S120D16MP11 1600 D 24 1/2 23 3/8 21 3/4 153 p TG9S120D2OMP11 2000 D 24 1/2 23 3/8 21 3/4 156 INF TG9S130D2OMP11 2000 D 24 1/2 23 3/8 No Hole 160 Ratings&Physical I Electrical Data Air Temp. Max.Outlet Fuse or Gas PipeInputOutputAFUEBlowerBlowerTotalUnit Models Rise Air Temp Circuit Connection, MBH MBH % Size Amps° F F HP Amps Breaker NPT TG9SO40A08MP11 40 38 95.5 30-60 190 1/3 4.8 11x8 15 8.6 1/2" TG9S060A1OMP11 60 57 95.5 30-60 190 1/2 7.0 11x8 15 10.8 1/2" TG9S060B12MP11 60 57 95.5 30-60 190 1/2 7.0 11x8 15 10.8 1/2" TG9S080612MP11 80 76 95.5 35-65 190 1/2 7.0 11x8 15 10.8 1/2" TG9S080C16MP11 80 76 95.5 35-65 190 3/4 8.6 11x10 15 12.4 1/2" TG9S080C22MP11 80 76 95.5 35-65 190 1 14.1 11x11 20 17.9 1/2" TG9S100C16MP11 100 95 95.5 35-65 190 3/4 8.6 11x10 15 12.4 1/2" TG9S100C2OMP11 100 95 95.5 35-65 190 1 14.1 11x11 20 17.9 1/2" TG9S120D16MP11 120 114 95.5 40-70 190 3/4 8.6 11x10 15 12.4 1/2" TG9S120D2OMP11 120 114 95.5 35-65 190 1 14.1 11x11 20 17.9 1/2" TG9S130D2OMP11 130 123.5 95.5 45-75 190 1 14.1 11x11 20 17.9 1/2" Annual Fuel Utilization Efficiency(AFUE)numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code(NFPA-70-latest edition)and all local codes. The furnace shall be installed so that the electrical components are protected from water. 2 Johnson Controls Unitary Products 400991-YTG-K-1018 FILTER PERFORMANCE Concentric Vent Termination - For use through rooftop, side- The airflow capacity data published in the "Blower Perfor- wall.Allows combustion air to enter and exhaust to exit through mance" tables shown represents blower performance WITH- single common hole. Eliminates unsightly elbows for a cleaner OUT filters. installation. All applications of these furnaces require the use of field S1-1CT0302(2")&S1-1CT0302-636(2") installed air filters. All filter media and mounting hardware or S1-1CT0303(3")&S1-1CT0303-636(3") provisions must be field installed external to the furnace cabi- Sidewall Vent Termination Kit-For use on sidewall, two-pipe net. DO NOT attempt to install any filters inside the furnace. installations only. Provide a more attractive termination for loca- tions where the terminal is visible on the side of the home. NOTICE S1-1HT0901 (3") Single side return above 1800 CFM is approved as long as the filter S1-1 HT0902(2") velocity does not exceed filter manufacturer's recommendation and Condensate Neutralizer Kit - Neutralizer cartridge has a 1/2"a transition is used to allow use on a 20x25 filter. 9 plastic tube fittings for installation in the drain line. Calcium car- Recommended Filter Sizes(High velocity 600 FPM) bonate refill media is available from the Source 1 Parts (p/n 026-30228-000). CFM Cabinet Size Side inches Bottom inches S1-1 NK0301 800 A 16x25 14x25 1000 A 16 x 25 14 x 25 Side Return Filter Racks - The S1-1SR0200 Kit accommo- 1200 A 16 x 25 14 x 25 dates a 1",2"or 4"filter. The S1-1 SR0402 Kit accommodates a 1200 B 16x25 16x25 1"filter only. 1600 B 16 x 25 16 x 25 S1-1 SR0200-All Models 1600 C 16 x 25 20 x 25 S1-1 SR0402-All Models 2000 C 2)16 x 25 20 x 25 Bottom Return Filter Racks -The S1-1 BRO5* series are gal- 2200 C 2)16 x 25 20 x 25 vanized steel filter racks.The S1-1 BRO6*series are pre-painted 2000 D 2)16 x 25 22 x 25 steel filter racks to match the appearance of the furnace cabi- net. The S1-1BRO5" and S1-1BRO6"series filter racks accom- 1. Air velocity through throwaway type filters may not exceed 300 feet per min- ute(91.4 mlmin).All velocities over this require the use of high velocity fil- modate a 1", 2"or 4"filter. ters.S1-1 BR0514 or S1-1 BR0614-For 14-1/2"cabinets 2. Do not exceed 1800 CFM using a single side return and a 16x25 filter.For S1-1 BR0517 or S1-1 BR0617 For 17-1/2"cabinetsCFMgreaterthan1800,you may use two side returns or one side and the bottom or one return with a transition to allow use of a 20x25 filter. S1-1 BR0521 or S1-1 BR0621 -For 21"cabinets S1-1 BR0524 or S1-1 BR0624-For 24-1/2"cabinets Unit Clearances to Combustibles Combustible Floor Base Kit-These kits are required to pre- Application Upflow Downflow Horizontal vent potential overheating situations when the furnaces are Top 1" 0" 0" installed in downflow applications directly onto combustible Vent 0" 0" 0" flooring material. These kits are also required in any applica- Rear 0" 0" 0" tions where the furnace is installed in a downflow configuration Side 0" 0" 1" without an indoor coil and where the combustible floor base kit Front* 0" 0" 0" provides access for combustible airflow. Floor Combustible Combustible) Combustible S1-1CB0514-For 14-1/2"cabinets Closet Yes Yes Yes S1-1CB0517-For 17-1/2"cabinets Line Contact No No Yes •S1-1CB0521 -For 21"cabinets S1-1CB0524-For 24-1/2"cabinets 1. For combustible floors only when used with special sub-base. 24"clearance in front and 18"on side recommended for service access. High Altitude Pressure Switches - For installation where the All furnaces approved for alcove and attic installation. altitude is less than 5,000 feet, it is not required that the pres- ACCESSORIES sure switch be changed. For altitudes above 5,000 feet, see kits Propane (LP) Conversion Kit-This accessory conversion kit below. may be used to convert natural gas units for LP operation. S1-1 PS3306-060 S1-1NP0347-All Models except 130K Model S1-1 PS330 - 00, 20 S1-1 NP0501 -130K Model S1-1 PS3302- 100, 120, 130 Thermostats - Compatible thermostat controls are available LP Stainless Steel Burner Kit-This accessory conversion kit through accessory sourcing. For optimum performance, these may be used to convert existing burners to stainless steel burn- units are fully compatible with our ColemanresidentialLuxaireY- ers for LP use only. ork touch screen thermostat with proprietary (patent-pending) S1-32926889000-All LP Models hexagon interface. For more information, see the thermostat Natural (NAT) Gas Stainless Steel Burner Kit - This acces section of the Product Equipment Catalog. sory kit may be used to replace existing burners with stainless S1-THXU280-All Models steel burners for NAT gas use only. S1-32924441000-All NAT gas Models Johnson Controls Unitary Products 3 400991-YTG-K-1018 Blower Performance CFM-Any Position(without filter)-Bottom Return Bottom Airflow Data(SCFM) Models Speed Ext.Static Pressure(in.H2O) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 High 1128 1077 1035 996 950 891 842 781 708 646 TG9S040A08M P11 Medium High 934 909 867 834 818 780 745 696 631 584 Medium Low 746 735 714 679 653 629 596 585 547 494 Low 676 652 627 601 581 542 516 474 441 383 High 1360 1290 1230 1165 1103 1043 983 925 820 776 TG9SO60A10MP11 Medium High 1251 1198 1140 1089 1038 979 916 854 790 718 Medium Low 1081 1062 1015 964 917 871 819 767 710 634 Low 909 900 852 812 769 739 712 662 612 547 High 1492 1442 1378 1325 1243 1176 1075 966 849 655 TG9S060612MP11 Medium High 1236 1201 1161 1139 1082 1011 919 830 715 590 Medium Low 986 950 961 916 872 831 757 703 600 510 Low 824 795 783 744 713 659 624 554 489 389 High 1597 1537 1484 1435 1370 1286 1230 1155 1075 925 TG9S080B12MP11 Medium High 1338 1307 1273 1223 1179 1123 1065 998 928 812 Medium Low 1113 1094 1077 1043 1008 972 924 868 803 798 Low 937 916 900 877 854 817 775 718 639 560 High 1919 1865 1802 1738 1671 1600 1517 1414 1322 1201 TG9S080C16MP11 Medium High 1532 1533 1513 1499 1465 1416 1352 1283 1198 1084 Medium Low 1232 1313 1291 1280 1250 1209 1207 1148 1055 937 Low 826 821 853 858 838 817 794 776 760 711 High 2529 2435 2338 2256 2162 2041 1920 1794 1654 1501 TG9S080C22MP11 Medium High 2166 2111 2070 2001 1927 1849 1719 1614 1499 1344 Medium Low 1697 1685 1664 1631 1586 1531 1466 1393 1315 1185 Low 1383 1377 1358 1336 1285 1244 1199 1147 1048 925 High 1909 1880 1823 1776 1706 1637 1562 1474 1375 1252 TG9S100C16MP11 Medium High 1465 1463 1469 1485 1477 1416 1386 1324 1250 1114 Medium 1190 1222 1216 1215 1224 1189 1158 1145 1087 996 Low 787 834 819 836 819 810 790 761 690 707 High 2284 2205 2114 2021 1934 1848 1752 1653 1505 1397 TG9S100C20MP11 Medium High 1967 1905 1824 1763 1712 1628 1551 1473 1379 1213 Medium Low 1610 1563 1513 1480 1430 1367 1319 1261 1101 1012 Low 1326 1304 1267 1232 1183 1143 1080 1003 871 798 High 2020 1994 1958 1878 1805 1740 1647 1560 1445 1294 TG9S120D16MP11 Medium High 1551 1559 1549 1520 1494 1451 1383 1334 1253 1145 Medium Low 1270 1267 1269 1269 1254 1227 1185 1121 1051 985 Low 932 916 905 894 876 828 803 725 754 696 High 2341 2245 2153 2072 1977 1876 1769 1642 1506 1306 TG9S120D20MP11 Medium High 2002 1952 1878 1823 1739 1657 1563 1458 1322 1185 Medium Low 1615 1579 1533 1473 1430 1368 1282 1186 1091 953 Low 1352 1295 1259 1245 1190 1141 1076 998 938 820 High 2412 2329 2247 2173 2047 1980 1887 1777 1655 1511 TG9S130D20MP11 Medium High 2040 2004 1948 1876 1786 1738 1656 1562 1461 1314 Medium Low 1614 1591 1549 1531 1459 1400 1335 1267 1180 1061 Low 1327 1294 1257 1224 1198 1171 1124 1036 944 848 1. Airflow expressed in standard cubic feet per minute(CFM). 2. Motor voltage at 115 V. 4 Johnson Controls Unitary Products co Lo p CA CO M O (O CO CO O CC) O N O O o r OO m r M r M N O r O r Nom " CO CO N 't Omr-m r r ul cO N N N MCOCmOMCO0rCOCpOLo71)) W cco rO u) N O ) r O m ,- m N m o m e- O w M O N C) C n et N O 2 t 0) M CO 1l) O N K) e- co O M M C0 N CM N V .. C0 CA CO 0) O O CO O .. r NWN M CO CO O CO C7 M N M C0 [O [O r a0 CO CO p C r IC) O r O V O) O O CO M O) ^ O O r M N N r C0 CMp) r CO CO O 1- (p r CO CO . 6— m r CO C') N O r r N O M N O O O M O CO .4 N O r N W W CO C7 .= 1, 0)00R CO O CO a0 O M 10 0) O CO O O m M M a0 M m O m N 0 m co O M C0 N N N O O O Ce) O co CA O N- CO O N M p O C O r CO CO CO CO 10 CO N CA CO CM (D NO a O O O v N O r M r O Cn M Ce) m Cn CA iA M co CO CO N CO O O O CO CO CA co r CO CA r CO 10 ,_ 0 00 r M s_ co O CO M O Cn N r CO W Cn N O R CO , .- 0 r CO N O r N C0 O O O O V V O O O C0 M r r M N O CO r v co CO O A CO at 0 A N NO CO co R M CO 0 O Ncov. 000 M OmWmvoo1COOCOrC0O MNMOOO ^ MCOMON NNMVO NCO MCOCcor00mcCOOm0NO1C0MNOONete- OMOnNOCOMNCONMOMOC NI e U I co c m CO N CA ,, N O O CO N lC) 00 O C0 M CO O r CO N ( O r O CO m CO M Nr N CO M CO co r M CO CO CO CO N O o O M O 7 v CO m CO CO o r N m ca M s CO M N O m- c0 M V' CO CO co O N O O r CO U) a0 r O) r CO , Cp CO O N O N f0 '.t e- CO M e- r O) Cp M O r e- r a0 CO M O W O r- O y d CO CO CO O O CA O r- N M ... MID NNN O N CO C0 N r CO M m ' eT CA C) a 0) et 0) e- CO M M 0)Q o p CO CO r O e- r `f `f C0 6 O O 2 M r C0 O M N 7 CO N M O O CA M Co M .t N v r 0) e- ,S r V' M L W p m CO CO C0 N- O m r N O c0 CO M N O N N N O N 0) O N r M N r N CO 7 O N )- .- 0) r M e- O N N- d V' CO M co N CO CO N O 0) CO r C0 M co r r CO CO 0rJWOCO ) CO e- a N O O N C0 C0 O r O O N ) CO O CO N M r O M CO C0 CO a0 r O C0 r C0 N O mp0COCOC0NlA [O M co r .7 N O O r CO N m M m CO M r it N co O N 7 e- CO nr e- m O N ems- CV O NY , CCCe- .-- r- .- e- e- N e- e- e- e- cMI o M M CO C0 C0 CO N T (A r CO O N CO CO M M CO CO r CA r M O CO CO C0 o v N O_ r CO e- 0) Co O O 0) Cc O M (A CO O O CO 7 N C0 O capO0) r CO M O co M W r O N O OHO C0 N m N N CO M Or V' N N CO e{ m N C CO N N O M N 0a) e N N e yI c co y N M CO O O CO CO r N CD M r M N r 00 r m V O CO c0 O O) r CO 0) M N m .- CO 0) r r L- N C0 O o0 (O r O O eF ' N O CO N N 7 N O CO r M N CO O O CO m M CO M O CO CO w 47: O O m r t0 M N O a0 m r CC) M O (A CO N fA N N CD M a0 7 N N 00 O N 0) C0 N rm N ro CO N N 0) C0 N W 3 T O 2 O)t' M c00 ^ M M cO0 m Or s- rO O r [O O ( O CO OOi O M N N N M 0) nt ' COO CI) N r N V U) 0)i Cr) N N CO O U m 3 p ,- CA r CD .t N O 0 v N O r CO co O CA CO N C) N N CO M co Nr N '- co CA CO N CA C0 N a) N CA L N N 0) CO M - dCe- e- e- .- e- r- e- .- e- e- e- e- e- %- e" C V NO E 'm E y L 3 t 3 L 3 L 3 L 3 L 3 L L L L L v O USiOo) O rno o ' o go Imo m mo rno 0) 0 rno ° a O D 2 J = J i —I ± J = J 2 J d O L co T 0 L E E J = E E J = E E 0 _ E E J m E E o 0 E E o m E =o o m E E a m E E o m E E o m E E o `o E c i)C V 2 J = J =, 75 _ O Cu J = _7 J = O 3 J = 7 7 ,J = _3 J 'n Q? 3COr0 N c) (O 0) G) a) a) 0) D D D D D D 0) D D O o v 0 22 2 22 22 2 22 22 22 22 2 °- o d 0 EU a, -0C C01 N y H CO m 0 a a n_ O d a d CL v ticoC) L " tco00ONNONOOCOOcoNNto N N `a H N O a) f O CO o co co 0 0 0 0 0 0 0 a UO0 CO CO0 0co CO O O_ N_ N_ M e Obi co co co co n coV) Cl) V) V) 0 O C a) CA CA CA CA CA CA CA a) E O O0000000000OI- I- I- F F- I- Y Q coC m N C) e( 0t 7 t 5581709-YTG-C-0619 DESCRIPTION rig The YCD models are part of our successful LX Series split sys- tem air conditioner lineup. Optimized for the 13 SEER Regional Minimum Efficiency in the North US and Canada,these outdoor units are specifically designed to be matched with Johnson Controls Unitary Products indoor coils, furnaces, and air TECHN/CAL GUIDE han- dlers to provide a complete system solution. fORINSTgILATiO^r iry US NORTNFAv Ri Cl(1+.=rv:a c,. u• FEATURES LX SERIES s 4EAtilL,;JI'.Small Footprint - Minimum footprint for easier handling, I transportation,and installation.SPLIT SYSTEM aUl ill- Easier Installation - Independent panels provide quickAIRCONDITIONERSnsta"ationA"°we° access for unit setup. Installation time is reduced by easy 13 SEER — R-410A— 1 PHASE power and control wiring access. Options are provided for THRU 5 NOMINAL TONS indoor piston or TXV.The factory installed filter-drier and fac-1.5tory charge for a 15-Ft lineset means less time spent brazing MODELS: YCD18 THRU 60 and charging the system. The small base dimension and reduced unit clearances make for easier retrofits. Accessible Information - QR code on unit provides quick access to technical documents and warranty information. oll Durable Finish - The coated steel wire fan guard, coated 4 b•••. yr . external fasteners, and pre-treated G90-equivalent galva- nized:re:steel chassis components resist corrosion and rust 1*:.., ,;; Y, wi! > creep.Champagne colored powdercoat paint further protects irii external panels. la rrr, QualityCoils -The high efficiencymicrochannel aluminumws•:, , s0ii 9 oS. IK; os.si l,a. rsri coil is manufactured using an improved material system pro- Q.\.•., • r.9 •, f r • 1I% A.,••r/a+:I.- viding reliable performance and small unit size. Rugged Coil Protection-Coils are protected from mechan- ical damage by a proven stamped steel coil guard design. j0%' Protected Compressor-Compressors are protected inter- nally by a high pressure relief valve and a temperature sen- sor, and externally by the system high pressure switch. The liquid line filter-drier is factory installed to protect the corn- 00.,..`.v.c.''d•4pi w pressor against moisture and debris. CERTIFIEDGood— I;79 keying Reliable Operation - Ball bearing fan motors provide supe rowaotoPromises rior performance in extreme temperatures. AMERICAN • Environmentally Friendly - CFC-free R-410A refrigerant AMERICAN Y delivers environmentally friendly performance with zero Qozone depletion. M DESIGNED,ENGINEERED& w' -hi:rsIV‘x ASSEMBLED IN THE USA • Top Discharge-Warm air is blown up, away from the struc- ISO 9001 Certified Quality ture and any landscaping and allows compact location on Management System C US multi-unit applications. Due to continuous product improvement,specifications Low Operating Sound Levels -Developed using CFD and are subject to change without notice. FEA tools,the sturdy cabinet and top design provides sound Visit us on the web at performance of 77 dBA or lower. Compatible accessories for www.simplygettingthejobdone.com and further sound reduction are also available. www.york.com Better Service Access - Diagonal base valves with open Additional rating information can be found at access for low-loss fittings,single panel access to the electri- cal controls,swing out control box for full corner access, and removable fan guard allow easy access for unit mainte- WARRANTY SUMMARY* Hance. Standard 5-Years limited parts warranty. Agency Listed - Safety certified by CSA to UL 1995 /CSA 22.2. Performance certified to ANSI/AHRI Standard 210/240 Standard 10-Years limited compressor warranty. in accordance with the Unitary Small Equipment certification Extended 10-Years limited parts warranty when product is program. registered online within 90 days of purchase for replacement or closing for new home construction. Does not apply to R-22 models,3-Phase models,or Internet sales. See Limited Warranty certificate in Users Information Manual for details. FOR DISTRIBUTION USE ONLY-NOT TO BE USED AT POINT OF RETAIL SALE 5581709-YTG-C-0619 LIST OF SECTIONS NOMENCLATURE DESCRIPTION 1 BRAND Y Y=York FEATURES 1 NOMENCLATURE 2 PRODUCT TYPE C C=Air Conditioner PHYSICAL AND ELECTRICAL DATA 3 NOMINAL DIMENSIONS 3 SERIES EFFICIENCY D D= 13 SEER/1-Stage SYSTEM CHARGE FOR VARIOUS MATCHED SYSTEMS 4 AND STAGING US Northern Region) COOLING CAPACITY-With Air Handler Coils 5 18= 1.5 Ton 42=3.5 Ton COOLING CAPACITY-Upflow,Downflow& NOMINAL 24=2 Ton 48=4 Ton Horizontal Furnaces and Coils(Coil Only Ratings) 9 UNIT CAPACITY 36 30=2.5 Ton 60=5 TonMBH) COOLING CAPACITY-With High Efficiency Motor Furnaces .. 10 36=3 Ton APPLICATIONS AND ACCESSORIES 72 SOUND POWER RATINGS 72 REFRIGERANT B B=R-410A MECHANICAL SPECIFICATIONS 73 VOLTAGE 2 2=208/230-1-60 TYPICAL INSTALLATION 74 ( Voltage-Phase-Hertz) 1 = 1st GenTYPICALFIELDWIRING75GENERATION12=2nd GenALTERNATIVEINSTALLATIONCLEARANCES75 (MAJOR REVISION) PERFORMANCE DATA-1.5 TON 76 etc PERFORMANCE DATA-2 TON 81 S=Standard(No Options) PERFORMANCE DATA-2.5 TON 88 FACTORY OPTION S H=Hard Start Kit PERFORMANCE DATA-3 TON 95 STYLE LETTER A=Style A PERFORMANCE DATA-3.5 TON 105 (MINOR REVISION) A B=Style B PERFORMANCE DATA-4 TON 110 NOT USED PERFORMANCE DATA-5 TON 115 FOR ORDERING etc 2 Johnson Controls Ducted Systems 5581709-YTG-C-0619 PHYSICAL AND ELECTRICAL DATA MODEL YCD18B22S YCD24B22S YCD30B22S YCD36B22S YCD42B22S YCD48B21S YCD60B21S Unit Supply Voltage 208-230V, 14).60Hz Normal Voltage Range 1 187 to 252 Minimum Circuit Ampacity 12.9 14.8 18.4 20.7 25.3 28.5 34.3 Max.Overcurrent Device Amps 2 20 25 30 35 40 50 60 Min.Overcurrent Device Amps 3 15 15 20 25 30 30 35 Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Compressor Rated Load 9.7 11.2 14.1 15.4 19.2 21.8 26.4 Locked Rotor 46.0 60.8 73.0 83.9 123.9 117.0 134.0 Crankcase Heater No No No No No No No Factory External Discharge Muffler No No No No No No No HS Kit Required with TXV 4 No No No No No No No Fan Diameter Inches 18 18 18 18 22 22 22 Rated HP 1/8 1/8 1/8 1/4 1/4 1/4 1/4 Rated Load Amps 0.80 0.80 0.80 1.50 1.30 1.30 1.30 Fan Motor Nominal RPM 1075 1075 1075 1100 850 850 850 Nominal CFM 1950 1950 2150 2575 2925 3225 3350 Face Area Sq. Ft. 9.78 9.78 11.07 12.37 13.83 13.83 17.37 Coil Rows Deep 1 1 1 1 1 1 1 Fins/Inch 23 23 23 23 23 23 23 Liquid Line Set OD(Field Installed)3/8 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD(Field Installed)5 3/4 3/4 3/4 3/4 7/8 7/8 1-1/8$ Unit Charge(Lbs.-Oz.)6 2-13 3-1 3-10 3-11 4-8 4-8 5-6 Charge Per Foot,Oz. 0.62 0.62 0.62 0.62 0.67 0.67 0.75 Operating Weight Lbs. 115 115 130 145 165 165 190 1. Rated in accordance with AHRI Standard 110-2012,utilization range"A". 2. Dual element fuses or HACR circuit breaker.Maximum allowable overcurrent protection. 3. Dual element fuses or HACR circuit breaker.Minimum recommended overcurrent protection 4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model. 5. For applications with non-standard vapor line sizes,see the"Applications&Accessories"section of this Technical Guide. 6. The Unit Charge is correct for the outdoor unit,smallest matched indoor unit,and 15 feet of refrigerant tubing.For tubing lengths other than 15 feet,add or subtract the amount of refrigerant,using the difference in actual lineset length(not the equivalent length)multiplied by the per foot value. DIMENSIONS Dimensions Refrigerant Connection ioi..,,;,., r. ,......pw Unity Inches) Service Valve Size I t! 0 */ Model 11-' 43 f t' A B C Liquid Vapor ii.'® Op , !! ,:::::: YCD18622S 26 3/4 2424 poo titter YCD24B22S 26-3/4 2424 opYCD30B22S 30 24243/4 pooYCD36B22S 33-1/4 24 24 3/gA paDO YCD42B22S 30 29-1/4 29-1/4 p oar®7/8 op pO 0 YCD48B21S 30 29-1/4 29-1/4 m o cap,00 op0 YCD60621S 36-1/4 29-1/4 29-1/4 7/8$ ADO oQ0® Oo p0 Adapter fitting must be field installed for the required 1-1/8"line set. 0 pp All dimensions are in inches and are subject to change without notice. oz Oc3®,_Overall height is from bottom of base pan to top of fan guard. B / Overall length and width include screw heads AC334.M Johnson Controls Ducted Systems 3 5462274-YTG-B-0718 yo DESCRIPTION RMaxAlloyTM aluminum indoor coils are specially designed to be installed with UPG furnaces or modular air handlers as part of a matched air conditioning or heat pump system. UPG indoor coils can be applied with indoor orifices and/or TXVs according to the application. Most indoor coil models are available as"flex"coils for installation of the specific expansion device in the field. Select SKUs are available with factory- mounted TXVs or EEVs. Refer to the Technical Guide for the TECHNICAL GUIDE matched outdoor unit to determine the required indoor expan- sion device for your specific application. ADD - ON COILS CF series full cased coils are suitable for upflow or downflow FOR USE WITH SPLIT-SYSTEM applications. COOLING & HEAT PUMPS CM series full cased coils have the added flexibility of multi- MODELS: CF, CM, CU position installation.They are shipped as upflow/horizontal left 600-2000 CFM 1.5-5 TON COILS and are easily convertible to downflow/horizontal right. Select CM Models are available with a factory manufactured electronic expansion valve. CU series uncased coils are designed for upflow-only applica- 3' tions on top of furnaces.These coils may require field modifica- i tion of the ductwork.A Partial Case accessory is also available, kas shown on the accessories page. 4.. } If CF or CM coils are installed without the casing, a Diverter k k,;Shroud kit is required, as shown on the accessories page. CU coils include a factory-installed Diverter Shroud. UNCASED FEATURES UPFLOW Rigid Case Construction - an interior endoskeleton provides structural support eliminating screw heads protruding from the side of the cabinet that could damage property when being installed. Cabinet—Constructed of heavy gauge galvanized steel with a primer and finish coat providing a high quality corrosion resis- tant finish. MaxAlloyTM Coil- Long life aluminum coils built to deliver last- ing performance,efficiency and reliability.UPFLOW/DOWNFLOW MULTI-POSITION FULL CASED FULL CASED Foil faced insulation -The cabinet is insulated with a single CF CM piece of cleanable foil faced insulation retained by the endo- skeleton. The cabinet design is such that all edges of the insu- sio Housekeeping lation are contained. Good Housekeeping rsi snail CERTIFIED, I,,,,fIrrd,,r,,,,,, Electronic Expansion Valve (EEV) Factory installed on select CM models and sized to match with specific high-effi- ciency variable capacity outdoor units. Compact Cabinet - With the coil and access doors removed AMERICAN t the cabinet has a 20.5" casing depth in all models, which pro- QUALITY X'OO klit:IS X`1 vide ease of attic access and space constrained applications. DESIGNED.ENGINEEREDi ISO9001 Thermoset Drain Pan-Corrosion and UV resistant with a pos-ASSEMBLED IN THE USA I 'V J Certified Quality itive slope for proper drainage. Low water retention design maxManagementSystem imizes indoor air quality and consumer comfort. Due to continuous product improvement, Low Leakage Cabinet Design - Fully gasketed doors mini- specifications are subject to change without notice. mizes air leakage to no more than 2D/o when measured at 1.0" esp. minimizing conditioned air leakage and infiltration. Visit us on the web at: Duct Flange - Three sided duct flange is supplied to be field www.upgnet.com and www.york.Com installed when required. Thermostatic Expansion Valves-Select factory mounted as Additional rating information can be found at:well as field mounted models available utilizing chatleff fittings, www.ahridirectory.org no brazing required. FOR DISTRIBUTION USE ONLY- NOT TO BE USED AT POINT OF RETAIL SALE 5462274-YTG-B-0718 ACCESSORIES NOMENCLATURE Refer to Price Manual for specific model numbers. PRODUCT TYPE C C=Coil(Indoor) TXV Kits -Thermal expansion valve kits are available for flex D=Horizontal Duct coil applications with R-410A or R-407C refrigerant.All TXV kits are non-braze, bolt-on connections including the valve assem- POSITION F F=Full Cased, Upflow/Downflow bly and equalizer tube. No orifice or any other metering device MOTOR TYPE M=Full Cased,Multi-Poise is to be used in conjunction with the TXV. U=Uncased,Upflow Partial Case-Available to be used with CU coils in four widths. 18=1.5 Ton 42=3.5 Ton This option is intended for upflow applications where height lim- NOMINAL 36 24,25=2 Ton 48,49,50=a Ton itations prevent the installation of full cased coils. The Partial UNIT CAPACITY 30=2.5 Ton 60,61,64=5 Ton Case design allows the top section of the indoor coil to be 36,37,38=3 Ton installed in the duct or plenum. A=14.5" Coil Casing Without Coil-Coilless Cases are available in four B=17.5" CABINET WIDTH B widths that can be installed with the furnace or modular air han- C=21.0" dler during initial installation.This option is available to allow the D=24.5" installer the flexibility to add the coil at a later date without duct BA-BG=TXV Valve Size modifications. METERING DEVICE X El -E4=EEV Valve Size LIST OF SECTIONS X=No Valve(Flex Coil) DESCRIPTION 1 COIL TYPE A A=MaxAlloyTM'Aluminum Tube FEATURES 1 C=Copper Tube ACCESSORIES 2 GENERATION 1 =1st Gen NOMENCLATURE 2 (MAJOR REVISION) 1 2=2nd Gen DIMENSIONS-UC UNCASED COILS 3 etc. DIMENSIONS-CF UPFLOW/DOWNFLOW STYLE LETTER A=Style A FULL CASED COILS 3 (MINOR REVISION) A B=Style B DIMENSIONS-CM MULTI-POSITION FULL CASED COILS 4 NOT USED FOR COOLING CAPACITY-UPFLOW"N"ORDERING etc. TYPE COIL(COIL ONLY)5 COOLING CAPACITY-FULL-CASED"N"AND"A" TYPE MULTI-POSITION COIL(COIL ONLY) 7 COOLING CAPACITY-UNCASED UPFLOW"N" TYPE COIL(COIL ONLY)9 APPLICATION FACTOR-RATED CFM VS.ACTUAL CFM 10 APPLICATION LIMITATIONS 10 STATIC PRESSURE VS.AIRFLOW BASED ON WET COIL- UPFLOW CASED"N"TYPE COIL 11 STATIC PRESSURE VS.AIRFLOW BASED ON WET COIL- CASED"N"AND"A"TYPE MULTI-POSITION COIL 11 STATIC PRESSURE VS.AIRFLOW BASED ON WET COIL- UNCASED UPFLOW-"N"TYPE COIL 12 COIL TECHNICAL DATA-CASED UPFLOW/DOWNFLOW 13 COIL TECHNICAL DATA-FULL CASED"N"AND"A" TYPE MULTI-POSITION 14 COIL TECHNICAL DATA-UNCASED UPFLOW-"N"TYPE 15 AIR FLOW DATA-STATIC PRESSURE DROP FOR CU MODELS 15 AIR FLOW DATA-STATIC PRESSURE DROP FOR CF MODELS 16 2 Johnson Controls Unitary Products 5462274-YTG-B-0718 19-1/8" 1 r OPENING \OPENING) Lt7 IPO I 1tg1J1 .•l, 1` 1 f. I':1 l•. 1J AJ I41• greG.1 hl 1-112" BOTTOM OPENING cs ,.DIMENSIONS 1 19-1/8" g D(OPENING) f m350-002 o265-OO DIMENSIONS-CU UNCASED COILS DIMENSIONS -CF UPFLOW/DOWNFLOW FULL CASED COILS Dimensions 1 Refrigerant Connections 2,3.4 Models Height Width Line Size Dimensions 2 Refrigerant A B Liquid Vapor Models1 Height Width Opening Widths Connections3,4.5 CU18A 13-3/8 13-3/8 A B C D Liquid Vapor CU18B 13-1/4 16-3/8 CF18A' 19-1/2 14-1/2 13-1/2 13-1/2 CF1813 19 17-1/2 16-1/2 16-1/2 CU24A 15-3/8 13-3/8 CF24A* 19-1/2 14-1/2 13-1/2 13-1/2 CU24B 15-1/4 16-3/8 CF24B 19 17-1/2 16-1/2 16-1/2 CU24C 14-7/8 19-7/8 CF24C 21 21 20 20 CU30A 19-3/8 13-3/8 3/4 CF30A 21-5/8 14-1/2 13-1/2 13-1/2 CU3OB 19-1/2 16-3/8 CF3013' 23 17-1/2 16-1/2 16-1/2 3/4 CU30C 19-1/4 19-7/8 CF30C 21 21 20 20 CU3OD 19 23-3/8 CF300 25 24/1/2 23-1/2 23-1/2 CU36B 21-1/2 16-3/8 3/8 CF36A 25-1/2 14-1/2 13-1/2 13-1/2 CU36C 21-1/8 19-7/8 CF3613' 25-5/8 17-1/2 16-1/2 16-1/2 3/8 CU36D 21-1/4 23-3/8 CF36C 23 21 20 20 CU42C 23-1/8 19 7/8 CF36D 25 24-1/2 23-1/2 23-1/2 CU42D 22-7/8 23-3/8 CF42B 25 17-1/2 16-1/2 16-1/2 CU48C 25-1/8 19-7/8 CF42C* 25 21 20 20 CU48D 25 23-3/8 7/8 CF42D 25 24-1/2 23-1/2 23-1/2 CF48C' 27 21 20 20 CU60C 29-1/4 19-7/8 CF48D 27 24-1/2 23-1/2 23-1/2 7/8 CU600 29 23-3/8 CF60C" 33 21 20 20 1. All dimensions are in inches.3 CF6OD 32-3/4 24-1/2 23-1/2 23-1/2 2. Refrigerant line sizes may require larger lines for extended line lengths. CF61 D 37-1/4 24-1/2 23-1/2 23-1/2 See Application Data part number 247077. 3. Adapter fitting must be field installed for other line set size. CF64D 32-3/4 24-1/2 23-1/2 23-1/2 4. See outdoor unit technical guide for proper line set size. 1. Asterisk(')denotes coil model is available as a flex coil or with factory installed TXV. 2. All dimensions are in inches. 3. Refrigerant line sizes may require larger lines for extended line lengths.See Application Data part number 247077. 4. Adapter fitting must be field installed for other line set size. 5. See outdoor unit technical guide for proper line set size. Johnson Controls Unitary Products 3 5462274-YTG-B-0718 1s-1/9" - ' c DIMENSIONS-CM MULTI-POSITION FULL CASED OPENING) d (OPENING) COILS Dimensions 2 Refrigerantj/ t ' Opening Conn 3,a,sIkModelsHeightWidthactions Widths A B C D Liquid Vapor CM18A' 19-1/2 14-1/2 13-1/2 13-1/2 A CM18B 19 17-1/2 16-1/2 16-1/2 CM24A` 199211121/2 14-1/2 13-1/2 131/2 CM246' 19 17-1/2 16-1/2 16-1/2 CM24C 21 21 20 20 i CM256# 25-5/8 17-1/2 16-1/2 16-1/2 CM30A* 25-1/2 14-1/2 13-1/2 13-1/2 B ' 20 1/ JI BOTTOM OPENING CM30B` 23 17-1/2 16-1/2 16-1/2 2112/" DIMENSIONS CM30C 23 21 20 20 3/4 D 19-118" CM3OD 25 24/1/2 23-1/2 23-1/2 OPENING) CM36A 25-1/2 14-1/2 13-1/2 13-1/2 A0 -00 CM36B* 25-5/8 17-1/2 16-1/2 16-1/2 CM36C* 25 21 20 20 CM36D 25 24-1/2 23-1/2 23-1/2 CM37B# 25-5/8 17-1/2 16-1/2 16-1/2 CM37C# 25 21 20 20 3/8 CM38C# 33 21 20 20 CM42C* 27 21 20 20 CM42D 27 24-1/2 23-1/2 23-1/2 CM48C* 33 21 20 20 CM48D* 32-3/4 24-1/2 23-1/2 23-1/2 CM49C# 33 21 20 20 CM49D# 32-3/4 24-1/2 23-1/2 23-1/2 CM50C$ 37-1/4 21 20 20 7/8 CM50D# 37-1/4 24-1/2 23-1/2 23-1/2 CM60C* 33 21 20 20 CM60D' 32-3/4 24-1/2 23-1/2 23-1/2 CM61C# 37-1/4 21 20 20 CM61D$ 37-1/4 24-1/2 23-1/2 23-1/2 CM64D 32-3/4 24-1/2 23-1/2 23-1/2 1. (')denotes coil model is available as a flex coil or with factory installed TXV. denotes coils only available with factory mount EEV. denotes coils only available with flex coil or factory mount EEV. 2. All dimensions are in inches. 3. Refrigerant line sizes may require larger lines for extended line lengths. See Application Data part number 247077. 4. Adapter fitting must be field installed for other line set size. 5. See outdoor unit technical guide for proper line set size. 4 Johnson Controls Unitary Products r Job Name: IKINTag#x Submittal Data Sheet FTX3ONVJU / RK3ONMVJU 2.5-Ton Wall Mounted Cooling Only System Efficiency Cooling SEER 17.50 I EER 9.85 J J`li. ' g_, Performance r`rJ Cooling(Btu/hr) r _—="' Rated(Min/Max) 31,400(10,200/31,400) Sensible @ AHRI 21,030 Standard Operating Range 50°F-115°F e Extended Operating Range* 22°F-115°Fire/ 1 Rated Cooling Conditions: Indoor:80°F DB/67°F WB Outdoor:95°F DB/75°F WB Complete warranty details available from your local dealer or at With field settings and wind baffle www.daikincomfort.com.Warranty registration not required to receive the 10-Year parts limited warranty for residential or commercial installations. Electrical 208/60/1 230/60/1IndoorSpecifications Cooling System MCA 17 17 H M System MFA 20 20 Airflow Rate(cfm) 890 727 Compressor RLA 16.25 16.25 L SL Outdoor fan motor FLA 62 62 572 512 Outdoor fan motor W 93 93 Sound(dBA) 53/47/40/37 Indoor fan motor FLA 37 37 H/M/L/SL Indoor fan motor W 64 64 Dimensions(H x W x D)(in) 13-3/8 x 47-1/4 x 10-3/16 MFA: Max.fuse amps MCA:Min.circuit amps(A)FLA:Full load amps(A) Weight(Lbs) 38 RLA:Rated load amps(A) W:Fan motor rated output(W) Outdoor Specifications Compressor Hermetically Sealed Swing Type Piping Refrigerant R-410A Liquid(in)1/4 Factory Charge(Lbs) 3.64 Gas(in) 5/8 Refrigerant Oil PVE(FVC5OK) Drain(in)5/8 Cooling Max. Interunit Piping Length(ft) 98.4 Airflow Rate(cfm) H 2,528 Max. Interunit Height Difference(ft)65.625 Sound Pressure Level(dBA) 56 Chargeless(ft) 32.8 Dimensions(H x W x D)(in)28-15/16 x 34-1/4 x 12-5/8 Additional Charge of Refrigerant(oz/ft)32 Weight(Lbs) 133 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:September 2018 Page 1 of 4 FTX3ONVJU Dimensional Data DA/KJN1 1-3/4(45mm) 9/16(14.5mm) f 1 411n I S DJ mer 1 z 3g0 m 3 00 m o° 7SC m0 N J T.A c o co A SA Z z j O N co O $ CD 8 -o 71 Y'D 3 3 IMMIligiffiiiii 3 v_ Dm r--- 3 I. 3 0 20 2 o r N 3o m m m i co 0 m 30 3 r 1 Z m A 3 I , t y 1-3/4(45mm) 5/8(16mm)S 8.1/4(210mm) I 13-3/8(340mm) 13-3/8(340mm) r 2 0 - i oM m i/ L. 1 N OO D o 3 m 3. 3 m K z I * cD -I -uZ OM 33 m m33S zOxz mm Qma I SIm Z 0 o Cl) D m m 7-7/16(188.7mm) r m ro cn cn j K m z m—0 0 0 03 D m 3 0 3 4 n0 1.m r S \ 10 m 1-3/16(30mm)MIN S SPACE FOR PERFORMANCE) Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:September 2018 Page 2 of 4 RK3ONMVJU Dimensional Data DAIKI A U) N 0m CO DJ 33 6 a m 0 0 Ir I, T. v v) i............11- ")Ili! vr CO M N7 , m D HIIIIIIIIIIIIIIIIIMIogmrloriperI11cooz1a i 1_ . 1\ 30` i33o0I; Z m co 0 14-1/8 105) 0 28-15/16(735) w comm coo $v)r 11.7/16(291) A N53pm6-1/2(165) Qy pQpA 0m0 0y iy5 . OO IIOGDZm< -< i 1 xiov 0m c m lot IPIIr, A I j ii it 4 i 11 0I' Z.. N Ja i Q,; .tZ W11IA..i p OCO , o y, m 0=O N o 17 m 00 D Q o II aye„' Y'' '' O Ov,1- N 0 0 N .. 14ii'171I: 0 0 0 ar O A \ r LJ iv. 29 N N O) A N VUlO 111111111MININIIIMIMI MI gu)I T, 1 r f\ 3 15/16(100) I y Z 0 3-15/16(100)rn c n 13-3/4(350) Co m 5 1 4La m m CO A N Zm 4Ni o D W.F. r N m r m it= m 13-3/4(350) Z 0 x• = n D3, v Z0 o A P j r 37 a A 33 N N 1 Fr gm m 0 3 13-3/4 350 I 3-15/16(100) Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:September 2018 Page 3 of 4 Optional Accessories PDAIKI Indoor Unit Included Part Number Description BRP072A43 Wireless Interface Adapter BRC944B2-A08 Wired Remote Controller kit BRCW901A08 Wired Remote Controller Cable—25ft(included in above kit) BRCW901A03 Wired Remote Controller Cable—10 ft DACA-CPI-1 Inline Condensate Pump(Fits inside all Daikin wall&floor mount units) DACA-CP4-1 External Condensate Pump KRP928BB2S Interface Adaptor for DIII-NET t Outdoor Unit Included Part\umber Description KPW063A4 Air Adjustment Grille(RX&RK) KKG063A42 Back protection wire net Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:September 2018 Page 4 of 4 303.15-1-32 CC-0468-2019lustGoods, Inc. 276 Dix Ave © I c o Interior Alt ( 2279 s.f. MTIMechanical Testing Inc. .... acg7estrngServrceSForIndoorEnvironments AABC cometGetup— FILE COPY Just Goods FIRM: CUSTOMER: MTI- Mechanical Testing,Inc. Northern Mechanical Service PROJECT#: 4 Chelsea Place,Suite 102 19-532 Clifton Park NY 12065 . PROJECT ADDRESS: PHONE: 276 Dix Avenue 518)450-7292 Queensbury NY FAX: DATE: 518)450-7295 2019-11-20 0 0 FCONTACT: . Tom Madigan Sustainable Solutions for Efficient Environments. I; J 1 _ a I Test/ ,ell: nvi 0pP Ag I W,P MEN 11 I JAN 31 2020 ,, .7 /NW 1, e..; 1 R I-iL-2:-I i ,-,_i' .1 OWNED w_._=11 . a d v A CERTIFIED BY I NATIONAL CAUNC LENTERPRISE15-0 i\o . 11.,0140f This is to certify that Mechanical Testing, Inc.has balanced the systems described herein to their optimum performance capabilities. The testing and balancing has been performed in accordance with the standard requirements of the Associated Air Balance Council and the results of these tests are herein recorded. Sustainable Solutions for. Efficient Environments 4 Chelsea PI,Suite 102 Clifton Park NY 12065 Phone:518-450-1292 Fax:518-450-1295 Design Review=Commissioning-Fire Life Safety=Test And Balance ASHRAE 110-Drone Sales/Inspections Terms and Abbreviations In:Inches In.w.g:-Inches of Water Gauge ACH-Air Changes per Hour ISDFT Insufficient Straight Duct for.Traverse AHU=Air Handling Unit Kfactor-Correction factor to the free area AK-Free Area of Duct needed to calculate CFM. AVG-Average LAT-leaving Air Temperature BHP Brake Horsepower LWT-Leaving Water Temperature BY-Ball Valve(Shut Off Valve)MAU-Make Up Air Handling Unit CB-Circuit Breaker MAX-Maximum set point/flow CBV Calibrated Balance Valve MIN-Minimum set point/flow CD-Ceiling Diffuser NI-Not Installed CFM=Cubic Feet per Minute ScopeNISNotiri CHWS Chilled Water.System 0/A-Outside Air CRAC-Computer Room Air Conditioner OBD=Opposed Blade Damper CS-Circuit Setter OD-Outside Diameter Measurement of Sheave CUN=Cabinet Unit Heater PH-Phase PSI-Poundsper Square InchDAT=Discharge Air Temperature q DD-Direct Drive(motor) RA-Return Air Des.-Design RAT-Return Air Temperature Disch:Discharge RF-Return Fan DNE-Does Not Exist HNC-Reheat Coil, DP-Discharge Pressure of Pump/Pressure Drop RPM-Revolutions per Minute EA-Exhaust Air RTU-Roof Top Unit EAV-Exhaust Air Valve SA-Supply Air EAT-Entering Air Temperature SAV-Supply Air Valve EF=Exhaust Fan SAT Supply Air Temperature EG=Exhaust Grille S.F.-Service Factor ERU-Energy Recovery Unit SF SupplyFan E.S.P.:External Static Pressure SP-Suction Pressure of Pump/Static Pressure EWT-Entering Water Temperature Sq.ft.:Square Feet FCU-Fan Coil Unit TAB-Test,Adjust and Balance FD-Fire Damper TDV-Triple Duty Valve FLA-Full Load Amperage TP-Thermally Protected Flow Coeff.-Correction Factor for Flow to VAV TSP Total Static Pressure Flow Hood-Instrument that measures airflow UH=Unit Heater FPM=Feet per Minute GPM-Gallons Per Minute V=Volts HEPA-High Efficiency Particulate Arrestance VAV-Variable Air Volume Box HP-Horsepower VD-Volume Damper HVAC-Heating Ventilation and Air Conditioning VFD-Variable Frequency Drive HWS-Hot Water System VVT-Variable Volume Terminal HX=Heat Exchanger WC-Water Column Hz-Hertz Mechanical Inc. 4.1.._- acNelpr_ NIT !gTestingServicesForIndoorEnvironments AABC °omm LOCATION:PROJECT NUMBER: Group CONTACT: Just Goods 19-532 Tom Madigan 276 Dix Avenue Queensbury NY Instruments Used Instruments Used AIR Manufacturer . , Evergreeri. Calibration.Date 8/19/19 S-PVF=1 Tech Name.-TM Serial No. 1500192 WATER: . Manufacturer - Not Applicable Calibration Date Not Applicable Model No. Not Applicable Tech Name Not Applicable Serial No. Not Applicable IMAGES: Air Calihratiun Cartilicate m N drR mwnsmeM. ....c.71. (.I.ww 1 M Fova+,rt v..qubno.sulOiKMwa w.umaY P^'v-iuiae% pnp nlpPmu Ma.WaNMna4aWN..N^i une.° W .: t'+wmrauur met` awe ,. cm. 40.II ast vaES Snr[u n mu eN9m.4 CMrwp.NwnwY _ Sij, Instruments Used Page'3 of 17 2019-11-20 MTI Mechanical Testa Inc.ac AABc gTestingServicesForIndoorEnvironmentAABC "Comm — LOCATION:PROJECT NUMBER: CONTACT: Just Goods 19-532 Tom Madigan 276 Dix Avenue Queensbury NY AHU I Motor Data MOTOR DATA. Motor Manufacturer See Note VoltsT1 , • 119 Volts Motor Frame See Note Volts T2 121 Volts Motor RPM See Note RPM Volts T3 121 Volts Motor.Horsepower" See Note HP Plate Amps. : • 14.1Amps Motor Phase See Note. Amps Ti 11.50 Amps Motor Hertz 60 Hi Amps'T2 11.50 Amps Service Factor 1.0 Amps T3. 11.80 Amps Efficiency. 0.850 Starter Heater - • cb Power,Factor 0.850 ':. Brake Horsepower:. 2293'. Plate Volts See Note Volts NOTES: Motor Data Motor Manufacturer Motor not accessible.Only able to see partial motor tag: Efficiency The Power Factor and Efficiency are not listed on the motor tag.MTl used the industry standard of 0.85 for each to determine an ESTIMATED BHP: AHU I Drive Data DRIVE DATA Motor Sheave/OD Size Direct Drive Fan Bore. .• Direct Drive in Motor Bore Direct Drive in No.of Belts' Direct Drive Motor Sheave%Closed Direct Drive% Belt Size Direct Drive Fan Sheave/OD Size Direct Drive Center Distance Direct Drive in AHU 1 Test Pressures AHU Page 5 of 17 2019-11-20 I MechanicaITestng Inc. acgM1 Testing Services For Indoor Environments CommissioningAABCGroup LOCATION:PROJECT NUMBER: CONTACT: Just Goods 19-532 Tom Madigan 276 Dix Avenue Queensbury NY II t `' • 1' p f4. I;, i `x`a'1,,T,'1t..r V.- I I 7 I I J II, i I \ \ ill / -44 1 I 4i I r r o V trF- fi I r F' I I 1 1. ' f I s_ I. I -_ IMO. 5 410.ms ,1:::_,,.__ r#,-. .- rj" sgro9, • ... •i., L:-' , r l r i t f 7t r AHU I Traverse Summary AHU Page 7 of 17 2019-11-20 Mechanical Testing Inc. -A1-1.t-MTI ac TestingEnvironments WServicesForIndoorEnvronne comm ormrgAABC LOCATION:PROJECT NUMBER: CONTACT: Just Goods 19-532 Tom Madigan 276 Dix Avenue Queensbury NY NOTES: Supply Outlet Summary SO=002*1 Room No. There is no Volume damper for this diffuser,unable to further reduce flow: SO-003*I Room No. There is no Volume damper for this diffuser. SO-011*I Room No. There is no Volume damper for this diffuser;unable to further reduce flow. SO-016*I Room No. There is no Volume damper for this diffuser,unable to further reduce flow. AHU I Return Inlet Summary RETURN INLET SUMMARY Name Room No:: Type Size AK Factor Design FPM Design CFM Reading 1- Reading 2 Final CFM %of Design ' RI-001*Office RA 24x24 1.100 182 200 ': 106 93 102 51. RI-002' : Office RA 24x24 ' 1.100 182 200 61 81. 89 45 RI-003*Office RA 24x24 1.100 182 200 128 126 139 69 RI-004*: Office RA 24x24 1.100 182 200 117 91 100 50 RI-005* Corr. RA 24x24 1.100 68 75 35 35 39. 51 RI-006; Security RA 24x24. 1.100 68 75 . 34 34 37 50 RI-007*Locker RA 24x24 1.100 273 300 135 135. 149 50 RI-008*Break RA 24x24 1.100 273 300 70 70 77 26. RI-009* Lab RA 24x24 1.100 273 300 95 95 105 35 Totals 1850.. 837 . .. . AHU Page'9 of 17 2019-11-20 MTIMechanical Testing Inc. aCg Testing Services For Indoor Environments aaBc V CommimomngAABC LOCATION:PROJECT NUMBER: CONTACT: Just Goods 19-532 Tom Madigan 276 Dix Avenue Queensbury NY Energy: Recovery Unit ERU UNIT DATA Equipment Location 2nd Floor Mezzanine SF Filter Quantity -1 Area Served _ Office EF Filter Type Filter Media Unit Manufacturer.. LifeBreath EF Filter Size Not Listed in Unit Model No.CABI 11231867385 .EF Filter Quantity. 1 Unit Serial No: 35ODCS Performed By" TM SF Filter Type. Filter.Media Test Date 11/19/19 SF Filter Size Not Listed in Pass/Fail See Notes NOTES: Unit Data Pass/Fail Exhaust is moving 74%of design airflow,the inlets have been proportioned for available airflow. ERU I CFM Test Data CFM TEST DATA Design Actual. Design .Actual 325 CFM 300 CFM:. 92 325 CFM 240 CFM 74 SF Unit CFM EF Unit CFM SF Outlet CFM 325 CFM 300 CFM 92 EF Inlet CFM, 325 CFM 240 CFM 74. Direct Drive Direct Drive Direct Drive Direct Drive SF RP IN EF RPM RPM RP.M' RPM RPM SF Hertz at Design CFM 60 Hz EF Hertz at Design CFM • 60 Hz ERU I SF Motor and Elec. Data ERU Page 11 of 17 2019.-11-20 Mechanical Testing Inc. = acgTestingServicesForIndoorEnvironmentsoast AABC comet - LOCATION:PROJECT NUMBER: CONTACT: Just Goods 19-532 Tom Madigan 276 Dix Avenue Queensbury NY SF TEST PRESSURE. . Design .. Actual Design Actual Not Listed in. Not Not. 1-120O 0.33 in.H2O Applicable in Applicable in. SF.Total SP SF Pre-Filter DP H2O H2O SF Fan Suction 0.30 in.H2O SF Exchange DP - 0.01 in:H2O Not Listed in H2O. Not Listed in. SF Fan Discharge 0.03 in.H2O SF Heat Coil DP. H2O 0.26 in,H2O Not Listed in. Not Listed in. SF External SP 0.31 in.H2O SF iCoolCoilDP H2O H2O 0.14 n.H2O SF Final Filter DP Applicable in. Applicable in. H2O H2O . . ERU I EF Motor and Elec. Data EF MOTOR AND ELEC..DATA Motor Manufacturer. See Note Volts T1 120.Volts Motor Frame See Note Volts T2 120 Volts Motor RPM See Note RPM Volts T3 120 Volts Motor Horsepower See Note HP Plate Amps See Note Amps .- Motor Phase See Note Amps Ti 3.00 Amps Motor Hertz : . 60 Hz Amps T2 3.00 Amps Service Factor See Note Amps T3 3.00 Amps Efficiency 0.850 Starter Heater CB Power Factor 0.850 Brake Horsepower 0.603 Plate Volts See Note Volts ERU. Page 13 of 17 2019-11-20 MechanicalTesting Inc. AMTI acg Testing Services For Indoor Environments VgAABC Comm g- trP LOCATION:PROJECT NUMBER: CONTACT: Just Goods 19-532 Torn Madigan 276 Dix Avenue Queensbury NY IMAGES: Photo's t. •/ P LIFEURERTNNEAT pCOT'RT. r R Wt' •' H .• 16 . ry us MODEUMODELE ENTiL TEOR'1rcGUrwTwan.E• O 9 , A„,. y. - SERIAL NUMOEN,HUMERO DE SERIE QUO 11s1Yf l J u`- f TI OLTS ]IOU i so Hz . MPs TornL as " iiannofit` 1 __ _ L- Rrl " t . 11 ERU Page 15 of 17 2019-11-20 Mechanical Testing Inc.mori acgTestingServicesForIndoorEnvironmentsCommissioning_AABC c LOCATION:PROJECT NUMBER: CONTACT: Just Goods 19-532 Tom Madigan 276 Dix Avenue Queensbury NY ERU I Supply Outlet Summary SUPPLY OUTLET.SUMMARY Name Room No.' . Type Size AK Factor - Design FPM Design CFM Reading 1 Reading 2 Final CFM %of Design SO-001 Storage Duct 12x8 0.545 . 596 325 550 550 300 92 Totals:.. 325 . 300.. .- ERU 1 Exhaust Inlet Summary EXHAUST INLET SUMMARY Name Room No. .Type Size AK Factor. -- Design FPM Design CFM Reading 1 Reading 2 Final CFM- %of Design El-001 Visit RR EA 24x24 1.100 68 75 55 49 54 72 EI-002 Men RR -- EA 24x24 1.100 91 100 83 72 79 79 EF003 Lady RR EA 24x24 1.100. 68 75 34 49. 54. 72 E1-004 IT Room EA 24x24 1.100 68 75 33 48 53 70 Totals 325 240 ERU Page 17 of 17 2019-11-20 7.7-- ---;0,3:.,.972,,:i-elVle''F.T7---7::-'7':.-:::''''''::':i4C-;Lq ::'''' -'...2.:',_ Aitr\,-----,--.-...,---,1, l—,',.'`.,,:,;',-.. 3;'.,-. f,.,-;'7._..::..- i',.:,,-4.. i!, r,.':-,.,,..,::-,..- N-,...-.;:-.:,-_,::,..',.,,,:-.,,--,,. 1_,,.'/,.-,,:2.;';-:'_ t;,:-.-. c-(‘,i,,:,,, tj.c.:.:::±,,;.' 4.=,:.-.--: L.."....,,! r,;.,_,:,:,: L:.,:'.-,;.::44f.--:.,.7: vfi1Z,.,.3_,:,,;s,-':;.,;':-.-!,.e.;,..'..,.';',.„ I,.',:.:-.-- J.",,,-; J... f.- e.,-=-.,-,! v---,--,,;,-:,.,?;.-..•..;...,...-?,:,.:-.,,:,:.,, ram" e ems'miii\s, t . Lam, y.:.5.` 4' py b Y S t E t (1 FI JAN S' pCFPARTITION,_....., __. 3.' 1;,:'?,::.',: i.i,.:.-,:„:..,,,,..,_,: I., l:.',..,.,„:=:4__,",_::' 1,,:,-:: r,-.,,: v,, 7.-_,.;?--,.,,.,-':_.., 1,.-.,:.- --,:_:,;_,.' A',-' l..i'.,-.„'.,,:.. 2,,,,,--;.,.,.,'.'.--:.. 7;------,---,---.l.,__,,- l_.,,-'---, i,--r-,':'-;.:.' INSULATED!-METAL w it _„i 4: WA L L P A`N-E L 71: a?:rl FILE.-COPY LOCK & GROOVE PANELTheCFPartitioninsulatedmetalpanelisdesignedto SYSTEM be the most economical choice for interior partition applications. The lightly corrugated profile provides r added strength on both faces and ensures symmetry from the exterior to the interior of the building, and between rooms. PANEL PROFILE PRODUCT SPECIFICATIONS WIDTH 441/2" THERMAL VALUES•ICfactor,Btu inlft2 hr.°F @ 75°F(24°C)mean core temperature=0.140.K-factor,Btu infft2 hr.°F THICKNESS -2",2++/z",23/a"`,3",4",5",6" 40°F(4°C)mean core temperature=0.126. LENGTH 8'-0"to 52'-0"for vertical embossed U-FACTORS AND R-VALUES 8'-0"to 40'-0"for vertical unembossed U-FACTOR(BTU/h•ftz°F) R VALUE(h•ftz°F/8TU) PANEL WIDTH:441/2" PANEL WIDTH:44'k- 05 EXTERIOR PROFILE•Mesa,nominal 1/a"deep,embossed or 75° 75° N C W Light Mesa,nominal'/a"deep,embossed 2' 0.0706 2' 14.16 eyrF W 2++/z' 0.0516 2<• 21.28 2'/z' 19.38 0• v O EXTERIOR FACE•G-90 galvanized or AZ-50 aluminum-zinc coated, 23/; 0.0470 304 or 316 stainless steelin 26,24,22 Ga". 3' 0.0424 3° 23.58 k p 4' 0.0324 4' 30.86 D I:. .WINTERIORPROFILE•Mesa,nominal Ys"deep,embossed or 5' 0.0264 5' 37.88 fn Light Mesa,nominal Via"deep,embossed 6° 0.0224 6' 44.64 A = N ci INTERIOR FACE•G-90galvanized or AZ-50 aluminum zinc coated,PANEL WIDTH:44irz" PANEL WIDTH:44Yz" 3 304 or 316 stainless steelin 26,24,22 Ga"'. 40° 40° 2' 0.0669 22' 14.95 0 JOINT-Offset double tongue-and-groove 0 1z' 0.0491 i 20.37 3 n2 23/4' 0.0446 O 3' 24.94 2<' 22.42 CORE-Foamed-in-place,zero ozone depleting(zero ODP)polyurethane, 3' 0.0401 FM Class 1 approval 4' 0.0305 4' 32.79 lin5' 0.0248 6' 47.62 5' 40.32 FASTENING•Through fastened at the top and bottom of the panel 6' 0.0210 N USDA Compliant stainless steel for use in aggressivelaFMApprovedClass1withnoheightrestrictions. N or daily wash-down areas Available only from Nevada plant 22 Ga not available for stainless steel may, 1) Metl-Span:Performance Redefined. 1720 Lakepointe Drive,Suite 101,Lewisville,Texas 75057(p)877.585.9969(f)972.420.9382 metlspan.com 02019 Metl-Span an'NCI Building Systems Company.All rights reserved.Printed in the'U.SA PART#CFPDS0616 7 . ...---, / e(4,4 40 , ate , i N5 1 ( 14 VINYLSHIELDTM A, C Smooth Mineral Fiber A mineral fiber panel that meets federal sanitary requirements,this panel is ideal for sanitary and clean room applications. 1 i r APPLICATIONS Clean Rooms Food Preparation Areas L • Sterilization/Areas i Restaurants iw 1 j• Laboratories • S, * . .k,#44,1 i ti 3 t: M s 1 -. 44; • Treatment.Rooms a r, s1 t J.# • Other Commercial a ` j s a, 1 ti' #• 1 I' , Buildings/-Space i 4w R 1 '. I{+ "r .P',r i i 't r ?i:"% 4. ,^pgN Applications pm 4,•4 G y '$' i fi 7t t p. e1 . s1` C I Karn2 ti" 1 r :sAygyy FEATURES AND BENEFITS LEED'Y,4• 4 Designed for sanitary and clean'room Vinyl facing provides an easy-to-clean, 1—t applications or where low particle emissions abuse-and stain-resistant ceiling perfect RECYCLED CONTENT 39 41% and maximum cleanliness are required for restrooms,laboratories,hospitals and sanitary food service areas EA:OptimizeEnergyPerformance Exceeds FGI guidelines for cleanability Tested to 2,000+wash cycles with Health Product Declaration(HPD)available i EA:Prereq.Min.Energy Performance chemical cleaners/sanitizers for this product VinylShield C features vinyl on face and back EQ:Interior LightingSatisfiesUSDA/PSIS guidelines for with sealed edges,creating fully encapsulated sanitary applications panel and dramatically reducing particle Approved for use in federally registered emissions for clean room applications 1 MR:PBTSourceReduction(Healthcare) Canadian food establishments I' EQ:Acoustic Performance Suited as a clean room class 5 component i I" I EQ:Prereq.Min.Acoustic Performance 1 I (Schools) SUSPENSION SYSTEM OPTIONS tie; EQ:Low-Emitting Materials W EQ:Daylight _- Trim 15/16 arm 1 MR:Material Ingredients(HPDs) tic MR:Sourcing Raw Materials MR:Environmental Product Declarations i (EPDs) ' MR:Construction and Demolition Waste i Management Planning iff '-'G 11ii"13z- . HPD Alailarle Recycled Portent CertainTeed I Customer Support I certainteed.com/ceilings 1800-233-8990 SLANT-GOBAIN 1 • VINYLSHIELDTM A, C Smooth Mineral Fiber All products in this line 111 01 B III— HPD VOC feature these attributes: SAG BIOSHIELD' LR WASHABLE HPD EMISSION RECYCLED RESISTANT MOLD/MILDEW 038 w/SANITIZING AVAILABLE COMPLIANT CONTENT RESISTANT CHEMICALS CERTIFIED 39-41% VINYLSHIELD A Format Dimensions(in.) NRC CAC Recycled Pieces/ Sq.Ft./ Lbs./ Cartons/ Content carton carton carton pallet TRIM LI1102-CRF-1 Panels 24 x 24 x 5/8 39 41% 14 ----56 ------ 65 ---20 —. 1100-CRF-1 Panels 24x48x5/8 ir 41 41%8 64 70 18 1 VINYLSHIELD C Format Dimensions(in.) NRC CAC Recycled Pieces/ Sq.Ft./ Lbs./ Cartons/ Content carton carton carton pallet TRIM 1172-CRF-1 Panels 24 x 24 x 5/8 40 39% 14 56 65 20 1 __.,_.... 1170-CRF-1' Panels, 24x48x5/6 42z_ 39% - 8 84, ,70 18 CAN'T FIND A SIZE?Contact your local Sales Representative or call 800-233-8990 ACCESSORIES VINYLSHIELDACCESSORIES Product Name Pieces/carton Use C% 1170-SEL-1 Mineral Fiber Edge Sealant 1 For re-sealing cut edges;1 quart container PHYSICAL DATA MATERIAL VOC EMISSIONS MAINTENANCE Mineral Fiber Independently certified compliant with Wipe with a soft cloth or vacuum with California Department of Public Health brush attachment.Cleanable with ASTM E1264 CLASSIFICATION CDPH/EHLB/Standard Method sanitizing chemicals. Type IV,Form 2,Pattern G(A+C) Version 1.1,2010. Type X,Pattern G(C) WARRANTY MOLD/MILDEW RESISTANCE 10-year 104/90 Limited Warranty increases FIRE CLASS(ASTM E1264) BioShield'treatment included for added to 15 years when installed with CertainTeed All are Class A per ASTM E84&CAN S102 mold and mildew resistance. Suspension Systems.Full warranty Flame Spread:25 or less information can be found at Smoke Developed;50 or less certainteed.com/ceilings. Customer Support I certainteed.com/ceilings I 800-233-8990 CertainTeed SAINT-GOaAIN LEED'is a registered trademark of the U.S.Green Building Council. r 2/19 CertainTeed Corporation. 15/16" CLEANROOM STAB SYSTEM Acoustical Suspension Systems Designed for controlled environment rooms and provides a clean,particulate free,sealed ceiling system. MAIN RUNNER CROSS TEE 7/8"WALL ANGLE TfR,tiuil.J C l 3 Z may Ylf 3 tY rr ,46:gym.+^a. i FEATURES AND BENEFITS LEED®v4 Tested as a component in clean room design to •CertainTeed Classic Stab-style main runners RECYCLED CONTENTClass3(as defined by ISO Standard 14644-1) and cross tees for fast and sturdy installation Combine with Aquarock;"Envirogard;" G60 hot-dipped galvanized body with MAINRUNNER ,A z Symphony'f,Symphony f Rx,Symphony m,closed-cell gasketed flanges and white aluminum f PRE:24% I POST:31% I DOTAL:55% I Symphony m Rx,Vinylrock;"VinylShielde'A, capping(for superior corrosion resistance) to achieve product-specific clean CR05STEE ICC certified(ESR-3336)and compliant with room performance L.A.Research Report number 25978 PRE24% it POST:30 31%I[TOTAL 54-55%1 Satisfies FGI Healthcare Guidelines for High recycled content WALL ANGLE -; ' -t i4ceilingssystemsforpanelsweighingless than one pound per square foot PRE_19% 'I POST:69 -!1-TOTAL:88,; MR:PBT Source Reduction(Healthcare) MAIN RUNNER WALL ANGLE 1 MR:Material Ingredients(HPDs) FL 13/32 - 1-i MR:Sourcing Raw Materials r RIVA,t.,, r. -1 MR:Environmental Product Declarations 1 LVV us-xsne GASKET a f k MR:Construction and Demolition Waste , 4/1 Management Planning 15fi"—1 1 CertainTeed Customer Support I certainteed.com/ceilings 1800-233-8999 i SAINT-GOBAIN I Ii i l 15/16" CLEANROOM STAB SYSTEM Acoustical Suspension Systems Allowable Slot Seismic Structural Recycled Recycled Recycled Allowable Concentrated Grid Face Dimensions Spacing Pieces/ Ft./ Design Classification Content Content Content Uniform Load Load at midspan in.)in.)in.) carton carton Category (ASTM C635) PRE' POST' TOTAL' (pif)Ibt)•• MAIN RUNNER CR512-12t201 4/16 (44x111/2715/16 C'1 (20, Ea AF- IHDI (249‘' t31%1 1I% 16._6r 4147J CROSS TEE CRS2-12-121 115/16! 2 1-1/2x i//16f a (66! 12a 6 d 124%. 131%• (55%` 45.6! 57,01! ff CRS4-12-12 -.. - I 15/16:. .48x11/2x15/1.6 120.C., 60 1240' - --- - -24% ~ 31% 55%, 10.6.26.48 CRS4-12-20 15/16 48 x 1-1/2 x 15/16 12 0.C. 60 240 -HD 24% 30% 54%16.4 41 WALL ANGLE-ALUMINUM ERWA-14-14, f7/8_ (41x7/8x7/8! 9 LI 4i, C e 0-96, (6%r toe%' Maximum recycled content percentage.Recycled content varies by manufacturing location. Allowable concentrated loads at midspan are determined in accordance with AC368 Section 3.2.For each framing member,the allowable concentrated load must not be combined with the allowable uniform load. ACCESSORIES Dimensions Pieces/ Lbs./Item Number Product Name L-xW-xH-(mm) Color carton carton OSLEEVE1516 15/16"Sleeve 4 x15/16 x1/64(102 x 24 x 1) White 100 1.25 wI lirliti- CTSPC-2 Seismic Perimeter Clip n_-e- - 3-1/16x2-1/4x1-1/16(78x58x27) Metal 100 9 CTSTJ Seismic Transition Joint Clip 3-1/2 x 3-1/2 x 1-3/16(89 x 89 x 31) Metal 100 10 ar AHD Adjustable Hold Down Clip 1-1/8 x 1/2 x1-11/16(29 x 13 x 43) Black 1000 16. . Hanger Wire 12'(3660 mm) 144x12gagex12gage 41 a HW12 0Metal141512Gage(2.05 mm) 3658x12 gage xl2gage) Z x r DLC Direct Load Clip • I-1/8 x 3-1/16 x 1/16(29 x 78 x 2) Metal 150 9 1 SLOTTERI Slot Punch 11 x 3-1/4 x 1(280 x 83 x 26) Metal 1 2.5 SFYK Smar[FdYoke B.SSx1.25x9.56(217z32x243) Metal 20 9 t PHYSICAL DATA MATERIAL LOAD CLASSIFICATION END DETAIL Hot dipped galvanized steel(G60) Heavy duty and Intermediate duty Main Runner:Integral Stab per ASTM C635 Cross Tee:Staked-on Stab Clip FACE DIMENSION 15/16- SURFACE FINISH SEISMIC RATING Painted Aluminum Cap A,B,C,D,E,F CROSS TEE/MAIN RUNNER INTERFACE Stepped-end/Override PROFILE HEIGHT WARRANTY 1-1/2' 10-year Limited Suspension Systems warranty increases to 15 years when installed with CertainTeed Ceiling Panels. Full warranty information can be found at certainteed.com/ceilings. SEISMIC PERFORMANCE MAIN RUNNERS:MINIMUM LBS.TO PULLOUT CROSS TEES: CRS12-12-20 COMPRESSION/TENSION: CRS2-12-12,CRS4-12-12,CRS4-12-20 180 lbs. ICC EVALUATION SERVICE, INC., REPORT COMPLIANCE Suspension systems manufactured by CertainTeed Ceilings have been reviewed and are approved by listing in ICC-ES Evaluation Report ESR-3336.CertainTeed Ceilings suspension systems have been reviewed and are approved by listing in L.A.Research Report number 25978. Evaluation Reports are subject to reexamination,revision and possible cancellation.Refer to certainteed.com/ceilings for current reports. r.) Customer Support I certainteed.com/ceilings 1800-233-8990 CertainTeed SAINT•GOHAIN LEED is a registered trademark of the U.S.Green Building Council. (c 2/19 CertainTeed Corporation WeB-201A RUCINSKI HALL ARCHITECTURE Ronald Richard Rucinski Ethan Peter Hall 134 Dix Avenue Glens Falls NY 12801 JAN 31 2020 Voice 518 741 0268 Fex 518741 0274 Email ephall@nycap.rr.com Special Inspection Report To:John O'Brien -Town of Queensbury —Code Enforcement Officer From:Ethan Hall Date:31 January,2020 Re:JUST Goods -276 Dix Ave At the above referenced project location this office performed periodic on site observations of the construction.Including the installation of the enclosure clean room for the water filling equipment, the packaging line and racking for the warehouse portion of the project.All other items appear to be installed in accordance with the construction drawings and are acceptable to this office. If there are any questions please contact our office. Lip Ethan P.Hall —Architect. Rucinski Hall Architecture Regards, Y:\Rozell IndustriesJUST Beverages\276 Dix Ave\Paperwork\Special Inspection Letter~31 Jan 2020.doe 1