Loading...
2008-365 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20080365 Date Issued: Tuesday, April 19, 2011 This is to certify that work requested to be done as shown by Permit Number P20080365 has been completed. Location: 26 PASCO Ave Tax Map Number: 523400-301-019-0001-020-000-0000 Owner: STEVEN & DODY THETFORD Applicant: STEVEN & DODY THETFORD This structure may be occupied as a: Residential Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, ' ` r°` y•'" _ Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20080365 Application Number. A20080365 Tax Map No: 523400-301-019-0001-020-000-0000 Permission is hereby granted to: STEVEN &DODY THETFORD For property located at: 26 PASCO Ave in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: STEVEN &DODY THETFORD 26 PASCO Ave Residential Alteration $4,000.00 QUEENSBURY,NY 12804 Total value $4,000.00 Contractor or Builders Name/Address Electrical Inspection Agency Plans &Specifications 2008-365 160 sq ft porch& 1560 sq ft roof alteration $172.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Thursday,July 23, 2009 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T o ee r ay,July 23, 2008 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement ......... OFFICEUSE ONLY�........ .. . , * , ".:. >. 4 TAX MAP NO. PERMIT NO.__L��J �' r t , FEE PAID Date ta.in, BLDG,&CODES APPROVAL ; 9' 0 0 ACCESSORY STRUCTURE BUILDING PERMIT APPLICATION Use this application for any structure other than the Principal Structure (house)to include, but not limited to: garage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Structures-Sheds/Fences. A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT.NO INSPECTIONS WILL BE MADE UNTIL THE APPLICANT HAS RECEIVED A VALID BUILDING//PERMIT. OWNER: 54cue- T{'lCt'soCd INSTALLER/BUILDER: 5e, rr ADDRESS: 2(o Pa,,(_. A�t) ADDRESS: PHONE NOS. 3 G. 1 '?(o'7 PHONE NOS. LOCATION OF PROPERTY; _ G G'c.S c o p SUBDIVISION NAME: LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: ESTIMATED COST OF CONSTRUCTION: $ /Does ANY OTHER ACCESSORY STRUCTURES ON PROPERTY? IF YES,PLEASE LIST: CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: PHONE: 1aT FLOOR 2ND FLOOR TOTAL PROPOSED PROPOSED CONSTRU ON SQ.FT. SO.FT. SQ.FT HEIGHT FT.&IN. 5crc6h:" OPEN PORCH 140 1 y DECK ? 3 SEASON,COVERED OR ENCLOSED PORCH* io7A� BOATHOUSE BOATHOUSE WITH SUNDECK DOCK SHED POLE BARN DETACHED GARAGE(NO.OF CARS:) OTHER AGQES$ORYSi7RW?'URE: 1 a *CONSIDERED FLOOR AREA&MUST COMPLY WITH FAR[FLOOR AREA RATIO] REQUIREMENTS IF THE STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE. To the best of my knowledge, the statements contained in the application,together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes,the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with, whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes,an As-Built Survey by a licensed surveyor, drawn to scale, showing actual location of all new construction. QUESTIONS? CALL 761-8256 OR EMAIL I have read and agree the above. codes0gueensburv.net VISIT OUR WEBSITE FOR MORE INFORMATION Signed Dated: "'Y wwwmueensburv.net -„�-- Town of Queensbury- Community Development Office- 742 Bay Road, Queensbui iy, NY 12804 B 1-LGL 11-05 Queensbury Building & Code Enforcement - Residential Fina Inspection Office No. (518) 761-8256 Arrive: am/pm Depart- am/prn Date Inspection request received: Inspector's Initials: NAME: ��j , tr`� PE MIT#: '- LOCATION: DATE: TYPE OF STRUCTURE: Comments: Yw N NIA ,V BuildingNumber Address visible from road 6A:mc� Chimney Hei ht/V Vent/Direct Vent Location Fresh Air Intake 3 Inch Plumbina Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors _ Handrail 4 or more risers Guards at stairs decks ios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck porches 36 inures or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off a osed/regulator 18 inches above grade Interior privacy I trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safe glazky/Window in stairwells safety glazing 1 . Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery_backup: Attic access 30 inches x 22 inches x 30 inches(height)in acoessible area Crawl Spaces 18 inch x 24 inch access 1 .ft.--I 50 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation I Insulation Certification Floor truss,draft stopping finished basement 1,000 s .ft. Emergen2y egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves instalied/Heat Tra Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs dosed rise>4 inches Gara a Floor Pitched Garaae fins roofi /%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Are Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Sep0c System I Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required ;E�4 Okay to issue C I C or C 10 1 Temporary/Permanent L:\Buiiding&Codes Forms\Building&Codes\Inspection FormsWesidential Final Inspection Formrevised_100405.doc;Revised January 7,2008;Revised 6/26108 Queensbury Building & Code Enforceme Residential Final Inspection Office No. (618)761-8256 Arrive: am/pm De rt: -�� am/pm Date Inspection request received: Inspector's Initials; _ NAME: ,Y— PERMIT#: LOCATION: c 1 e DATE: TYPE OF STRUCTURE: Comments: 4' Build Number Address visible from roaYAL d ChimneyHsi ht/"B'Vent/Direct Vent Location / Fresh Air Intake 3 inch Plumbina Vent throuah roof minimum 6 inches Roof Co /Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs decks ios more than 30 inches above grade Guard at stairwell at 34 inches or more Guam at deck porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railin a 34 inches to 38 inches Deck Braft/HandlcapM Ramp Compliant Grade away from foundation 6 Incites with 10 feet 8 inch clearance to sill plate Gas Valve shut-off EmwW/regulator 18 inches above arade Interior RtM I trim/doors/main entrance 36 inches Bathroom/Kitchen wate ht Safety /Window in stairwells W%ty glazing Interior Smoke Detectors I Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces i8 inch x 24 inch access 1 ft:150 sq.ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss dreft stopping finished basement 1,000 sq.ft. Ememerw egress below arade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumac e/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat TreW Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum ��``'►^' Basement stairs dosed rise>4 inches G*Mgq Floor Pitched Game fireproofing/%hour fire door/door closer Duct work Seam prqW Gas Lone in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan { Arc Fault Breaker in Bedrooms Flex Gas Pipp Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification if required Okay to issue C I C or C 10 1 Tem ors /Permanent LABuilding&Codes Form"uilding&CodesVnspedion FormsWesidential Final Inspection Forn_revise4_100405.doc;Revised January 7,2008;Revised 6/26/08 �uee/ns ry i � dt&--C- oden Enforcement - Residential Final Inspection Offs No. 518 761-8256 Arrive: am/p part: l La n/pn Date Inspection request received: _ Inspector's Initials: - NAME: PERMIT#: LOCATION: z5Go DATE: TYPE OF STRUCTURE: Commen Y N N/A 4" Building Number Address visible from road 7-23 -07 Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Co fete/Exterior Finish Complete Platform at all exterior doors _ a Handrail 4 or more risers Guards at stairs decks ios more than 30 inches above grade L, Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapp2g Ramp Compliant Grade awav from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off /re ulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches U Bathroom/Kitchen watertight Safety glazingI Window in stairwells safety glazing interior Smoke Detectors I Carbon Monoxide Detectors Every level: Every Bedroom: Outside every ..m are : Inter Connected:d: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access 1 .ft.-150 sq.ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation/Insulation Certification ) Floor truss,draft sto finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off baler Relief Valves installed/Heat Trapt Water Temp 110 Enclosed Stairs Sheetrock Underside minimum IN Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed property Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Are Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance Tguired Flood Plain Certification,if required Okay to issue C/C or C 10 Temporary/Permanent L\Building&Codes Formsl8uilding&Codesunspection FormslResidential Final Inspection Form revised 100405.doc;Revised January 7,2008;Revised 6/26/08 Framing / Firestopping Inspection Report GG Office No. (518)761-8256 Date Ins on D' Queensbury Building &Code Enforcement Arrive: rt: iim 742 Bay Road, Queensbury, NY 12804 Inspector's Initi v NAME: f n ` .PERMIT# D LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N NIA COMMENTS: a ttic Access 22" x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 Y2 w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Botts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side i4 inch or 518 inch Type X Garage side 5/8 inch Type X Ceilingtwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LABuilding&Codes FomwOMBuilding&CodesNnspection FormsTraming Firestopping Inspection Report.doc Revised January 7,2008 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart: m/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:(4 Pyl\ NAME:_ PERMIT r Gr2-� ©(� S #: LOCATION: _ ?_4� ���� �c A, INSPECT ON: 0 TYPE OF STRUCTURE: Framing Y N WA COMMENTS: Attic Access 22" x 30" minimum L Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly t 12°O.C. Headroom 6 ft. 8 in. l Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 V2 w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall � �-- Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping _.-- Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side's inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. OM 5.7 sf above/below grade 5.0 sf grade LABuilding&Codes Forms-OMBuilding&Codesllnspection Fom►sTraming Firestopping Inspection Repo Ldoc Revised January 7,2008 c Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart. q am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: r n \ NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Zon solithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofmg Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspec[ion Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM t AveAl vuad TQ�tMa lJf l„1 LvGl1'F I�UI i .i XPI r, vi V � Based on our limited e rn!n,a%n', compliaiu;e with our cornet^rats shall E not be construed as indicalUng the r plans and specification,, are in full comvliance with the U,:ding Codes of -New Yua State. w W Ze . x 6 4 r y�=s e�V t IC t E_ z y� o� ,3t t M1S � S ij b�k 3 e� 't 59('40 4 ►fir 45 t r ; 1 art c r +' 4M