Loading...
2008-375 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 4E Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20080375 Date Issued: Friday, December 05, 2008 This is to certify that work requested to be done as shown by Permit Number P20080375 has been completed. Location: 28 AMETHYST Dr Tax Map Number. 523400-308-014-0001-011-000-0000 Owner. ROBERT KAY Applicant: ROBERT KAY This structure may be occupied as a: Deck By Order of Town Board Residential Addition TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building& de oreement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20080375 Application Number. A20080375 Tax Map No: 523400-308-014-0001-011-000-0000 Permission is hereby granted to: ROBERT KAY For property located at: 28 AMETHYST Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Tie of Construction Value Owner Address: ROBERT KAY HEIDI BASSETTI Deck 28 AMETHYST Dr Residential Addition $70,000.00 QUEENSBURY, NY 12804 Total value $70,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2008-375 168 SQ FT RESIDENTIAL ADDITION & 392 SQ FT DECK $75.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Thursday,July 23, 2009 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T o eens d esday,July 23, 2008 SIGNED BY 7zfor the Town of Queensbury. Director of Building 8t Code Code ' -3OlJ ./'7r"....... ......•_ OFFICE USE ONLY___....__-----_.___.,_...,_ _..% TAX MAP NO._v_ PERMIT N0. i FEES: PERMIT_ RECREATION ENGINEERING r (If applicable), r z PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF AA VALID PERMIT FOR CONSTRUCTION. / /� APPLI�f(p+{[/'��Nf(JT/BUILDER: E' jf'� �1�° OWNER: to �c�elc Kc, ce s f ADDRESS: L` a ADDRESS: ate PHONE NOS. ll� 7 t �f � Y- g PHONE NOS. CONTACT PERSON FOR BUILDING &CODES COMPLIANCE: PHONE: LOCATION OF PROPERTY: 0 14 '/7), SUBDIVISION NAME: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT p o E- APPLY TO YOUR t- 0O O w PROJECT F, O � a =O1-" w W CD 0 � o 1: LUU) U) o Z Q N _Z O u- F— LL CL _ ca SINGLE FAMILY t J TWO-FAMILY / v MULTI-FAMILY (NO.of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE L4- FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) -OTHER-Oec-i IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST: 7� FUEL TYPE: HEAT TYPEA (__ _HOW MANY FIREPLACE(S):______ AND/OR WOODSTOVES(S): ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? IS THIS A HISTORIC SITE? )rt PROPOSED USE OF BUILDING OR ADDITION: �n�h� Y Appliances&Chimne s"available in our office B 3-LGL 11-05 *Please complete a separate Application for"Fuel Burning Trn IIYi n{()1/PP11SI11lY1! ■ crimmvrih! T)°77°lrmm I'll f o f°O • 74? Rav RMr1 ni�v°rlal"'"' hiY 1�R(14 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY?_, I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. 1 certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and ee t abo Signed Director of Building &Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) ..................... Permission is hereby granted to the above ; This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said ; ; zoning Laws of the Town of Queensbury. 11 Application: ; ; ; I , 1 1 0 / 0 / / / / I I 0 / , 0 1 / 1 f , , o BUILDING & CODES APPROVAL ZONING APPROVAL 11 0 01 S S 01 DATE 0 10 DATE 10 1 0 00 i 0 I .................................................... ....__..... ........ QUESTIONS? CALL 761-8256 OR EMAIL codes(ftueensbury.net Office Use Only VISIT OUR WESSITE FOR MORE INFORMATION Operating Permit Issued: Yes No mn&meensburYnet Occupancy Type: Construction Classification: Assembly Occupancy Limit: Special Conditions: `> Town of Queensbury• Community Development Office - 742 BayRoad,, Queensbury, NY 12804 Check Residential Plan Review: One & Two Family Dwellings Y N/N/A (2)Full sets of plans Over 1,500 sq. ft.— tampe Design Loads On Plans: 90 Wind Floor Loads 40 psf 50 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade, 5.7 sq. ft. Grade,5.0 sq. ft. 24"(h)x 20"(w)min. 44"Max.Height above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofmg/Waterproofing Materials On Plans Foundation Drainage On Plans, if required 6"Drop in 10' Exterior Grade Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where Required Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors Stairway Headroom 6' 8' All Stairs 36"Width Stair Run and Rise Winder Run and Rise Spiral Not Allowed From 2° Story Smoke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance Hall Width, 36"min. Handrails More Than Four Risers On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation Garage Floor Sloped Attic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Outside Lowest Sleeping Area, On Every Level& Interconnected Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed _- _-_____-__ Cornrnunit DeveCo anent Q -ice own of Queensbury • 742 Bay Road • Queensbury, New York •12804 , Marilyn Ryba, Executive Director• David Hatin, Director of Building&Codes ' Craig Brown, Zoning Administrator ' WINDOW SCHEDULE JOB SITE/ADDRESS: _.___DATE:_ OWN ER: Its r _L ¢°` ---------------------APPLICATION NO.:-------------- — UNIT OR CLEAR WINDOW- CLEAR t WINDOW STOCK ROUGH ROUGH SQ.FT. OPENING NO.OR WINDOW SQ.FT. OPENING SPECIAL HARDWARE OR MANUFACTURER NUMBER OPENING OPENING EGRESS/CLEAR HEIGHT LETTER NAME MODEL/TYPE CALL WIDTH - HEIGHT VENT OPENING WIDTH IN IN INSTRUCTIONS ON PLAN SIZE INCHES INCHES 41� ram, S2 21 r "A Community Development Office own of Queensbury -742 Bay Road ■ Queensbury, New York •12804 � Marilyn Ryba, Executive Director• David Hratin, Director of Building&Codes Craig Brown,Zoning Administrator ; BUILDING PERMIT CALCULATION SHEET: FL4-N 0 NATURAL LIGHT, VENTILATION AND EMERGENCY EGRESS REQUIREMENTS AREA OF ROOM IN ACTUAL LIGHT REQUIRED ACTUAL SQUARE FOOT HABITABLE ROOM SQUARE FEET SQUARE FOOTAGE VENTILATION-4% VENTILATION OPENING FOR REMARKS OF ROOM AREA SQUARE FOOTAGE EGRESS 0tAJ1xt ` l j QUESTIONS 7 CALL 761-8256 OR EMAIL cod esCa oueens bury.net VISIT OUR WEBSITE FOR MORE INFORMATION www.guensbury.net Adov aftk Contmuttity Development Office Town of Queenshury • 742 Buy Rd. a r Quee�nshnry, Nov York •12304 PLOT PLAN Show all existing and proposed structures. Indicate the setbacks of all stru ures and buildings from all property lines. SIDE PROPERTY LINE ... _...... ca\? la- __ ... ,l ...... wf _._........ ;... !. ..., , .. 1. ... .. . .. ... .. ... .._.. :. _. ._ .......... ., N �. OT V .... . . m 4 1 . e. .,.... , N.. ... PAW � <,.. ...... ,... a ... ... .,:.3 C<u i -c ,k SIDE PROPERTY LINE 1 SQUARE — FT. COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit No... .. ....,3 7 ..Cert. N 2 '4 8 8Jr Cut-in Card No..................................... j.... Owner..............Tt.(...... ................................................................................................................. ....... Location.......' ' {7.. .r�1.. ...........................................................4c��.. ............... .............. .. -� Installation Consisting of..(..... `j. . + G'.l�. I .rG�.a ....................... .................... ....... .......... . .....1'' 5� & ?.�".....` c:.f3.. 1 .9- .?............................................................................. .................................................................................................................................................................................... Installed By........�� 3..Lr0 ATl .........................� Lic.No.................,................................. The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shalt be promptly made for inspection Inspectors of this Company shall have the privilege of pjikking inspections at An,. rules are //violated,the Company shall have the right tgSYevo thi certif— Date.....l..Z...........®.................... INSPF'r'r �,� ,air�'+'i ( � �-- ...y� l Y�i✓ ��� f, r.:.�` Queensbury Building & Code Enforcement - ((Residential Fi>�al Inspection Office No. (518) 761-8256 Arrive: am/pm Depart.Z ky am/pm Date Inspection request received: inspector's Initials: NAME: PERMIT LOCATION: DATE: t TYPE OF STRUCTUR : Comments: Yes No N/A 4" Building Number Address visible from road Chimney Height/°B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Com lete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs deckspatios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 N.ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 s .ft. Emergency ress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%,Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed Properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C 10 Temporary/Permanent LABuilding&Codes Forms\Building&Codes\inspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08 �5- - / 0 �'kdlkes � Rough Plumbing / Insulation Inspection eport / Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart-, am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: ra"11-1 PERMIT #: LOCATION: INSPECT ON: - - TYPE OF STRUCTURE: Y N N/A ® Rough Plumbing/Nail Plates C- Y / -S O r� Plumbing Vent/Vents in Place �Itof-o, 1 % inch minimum Drain Size r Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test W ply Piping ea 50 P.S.I for minutes Insulation/R idential Check/Commercial Check At kvrZhilar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: CL Rough Plumbing Insulation Report revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspection Report Y/Y Once No. (518)761-8256 Date Inspection request received: lo g Queensbury Building $Code Enforcement Arrive: am/pm Depart am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME. PERMIT# LOCATION: QZ INSPECT ON: TYPE OF STRUCTURE: t_ Y N wa COMMENTS: Framin Attic Access 22" x 31Y minimum Jack Studs/Headers Bracing I Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D naus each side Draft stopping 1,000 sq. ft. floor trusses Anchor Botts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 518 inch Type X Ceilingfwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LABuilding&Codes Forms-01-13l6uilding&Codes\lnsp"Wn ForrnsWron ft Firestopping Inspection RepoR.doc Revised January 7,2008 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart: k am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials NAME: PERMIT LOCATION: S INSPECT ON: TYPE OF STRUCTURE: Framing Y N NIA COMMENTS: Attic Access 22" x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice'and hield 24 inches from wall ire separatio , 2, 3 hour Fire wa112, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. OM 5.7 sf above/below grade 5.0 s#grade LABuilding&Codes Forms-OLD'Building&Codes\1nspection FortnsWraming Firestopping Inspection Report.doc Revised January 7,2006 ) -5 Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:/ r NAME: PERMIT#: LOCATION: S: t', INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab ackfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM 2- -z-/ ff/c t^, �i, Foundation Inspection Report Office No.(518)761-8256 Date Inspectio uest received: Queensbury Building&Code Enforcement Arrive: Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials. UU-1- NAME: / ' (• X PERMIT#: LOCATION: •INSPECT ON: eel 7"" TYPE OF STRUCTURE: Comments i Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement f. of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM CREScheck Software Version 4.1.4 NJ( Compliance Certificate Project Title: FITZPATRICK CONST. FOR ROB& HEIDI KAY Report Date:07/13/08 Data filename:Untitled.rck Energy Code: 2007 New York Energy Conservation Construction Code Location: Warren County,New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 26% Heating Degree Days: 7635 Construction Site: Owner/Agent: Designed600tieetep- Queensbury,NY 12804 Rob&Heidi Kay G.Peter Jensen Queensbury,NY 12804 17 West Road South Glens Falls,NY 12803 Compliance:0.0%Better Than Code Maximum UA:55 Your UA:55 ­'' , I :� �i Gross Cavity . Cont. Glazing UA Assembly Area or R-Value RaValue or D.. ,Perimeter U.-Pactor: Ceiling 1:Fiat Ceiling or Scissor Truss 168 38.0 0.0 5 Wall 1:Wood Frame,16"o.c. 324 21.0 0.0 14 Window 1:Wood Frame:Doubie Pane with Low-E 45 0.340 15 Door 1:Glass 40 0.340 14 Floor 1:Ail-Wood Joist(fruss:Over Unconditioned Space 168 21.0 0.0 7 Furnace 1:Forced Hot Air 89 AFUE The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems have been designed to meet the 2007 New York Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. G.PETER JENSEN / Name-Title 17 WEST ROADigna ure Date SOUTH GLENS FALLS NEW YORK 12803 Project Notes: (518) 798-3859 �o. ED Aqc Additio to single family residence Orb SEA ,• ��j� Plan#08-0604 ti �► apeo:o � t'TE OF N ct"M At Project Title:FITZPATRICK CONST.FOR ROB&HEIDI KAY Report date:07/13/08 Data filename: Untitled.rck Page 1 of 4 CREScheck Software Version 4.1.4 NJ( Inspection Checklist Date:07/13/08 Ceilings: ❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation Comments: Above-Grade Walls: ❑ Wall 1:Wood Frame,16"o.c.,R-21.0 cavity insulation Comments: Windows: ❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?—Yes—No Comments: Doors: ❑ Door 1:Glass,U-factor.0.340 Comments: Floors: ❑ Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-21.0 cavity insulation Comments: Heating and Cooling Equipment: ❑ Furnace 1:Forced Hot Air:89 AFUE or higher Make and Model Number: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation. Vapor Retarder: ❑ Installed on the warm4n-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment are identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. ❑ Insulation R-values,glazing U-factors,and heating equipment efficiency are clearly marked on the building plans or specifications. ❑ Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building are insulated to at least R-11. ❑ Return ducts in unconditioned attics or outside the building are insulated to at least R-6. ❑ Supply ducts in unconditioned spaces are insulated to at least R-11. ❑ Return ducts in unconditioned spaces(except basements)are insulated to R-2.Insulation is not required on return ducts in basements. Duct Construction: Project Title:FITZPATRICK CONST.FOR ROB&HEIDI KAY Report date:07/13/08 Data filename: Untitled.rck Page 2 of 4 LI All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric,or tapes.Tapes and mastics are rated UL 181A or UL 181B. Exceptions: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). The HVAC system provides a means for balancing air and water systems. Temperature Controls: Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: 0 Separate electric meters exist for each dwelling unit Fireplaces: Fireplaces are installed with tight fitting non-combustible fireplace doors. Fireplaces have a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: Lj Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or Is part of a circulating system. O Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: 0 Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: All heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps have a time clock. Heating and Cooling Piping Insulation: Ll HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Project Title:FITZPATRICK CONST.FOR ROB&HEIDI KAY Report date:07/13108 Data filename: Untitled.rck Page 3 of 4 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.6 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(°F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Project Title:FITZPATRICK CONST.FOR ROB&HEIDI KAY Report date:07/13/08 Data filename: Untitled.rck Page 4 of 4 D f y t G►N a c.A Vv "4 v(rrt C6r 3, ' saw evtde..- . i fe i f SIB j DAJ® i � t i 1 J i