Loading...
2008-391 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 4z Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20080391 Date Issued: Thursday, November 13, 2008 This is to certify that work requested to be done as shown by Permit Number P20080391 has been completed. Location: 11 ASHLEY PI Tax Map Number. 523400-302-018-0003-014-000-0000 Owner. ILENE HOERNING L.E. Applicant: ILENE HOERNING L.E. This structure maybe occupied as a: Residential Addition By Omer of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20080391 Application Number. A20080391 Tax Map No: 523400-302-018-0003-014-000-0000 Permission is hereby granted to: ILENE HOERNING L.E. For property located at: 11 ASHLEY PI in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: ILENE HOERNING L.E. AUDREY HOERNING-THOMAS Residential Addition $56,000. 0 11 ASHLEY PI Total value $56,00000 QUEENSBURY,NY 12804-0000 Contractor or Builder's Name/Address Electrical Inspection Agency HOMETOWN CONSTRUCTION 228 FT. EDWARD Rd FT. EDWARD,NY 12828-0000 Plans &Specifications 2008-391 372 SQ FT RESIDENTIAL ADDITION $75.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Friday,August 14, 2009 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the rsday,August 14,2008 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement rv.K; Community Development Office own of Queeusbury • 742 Bay Road • Queensbury, Ne711 York •12804 � of 1 4 1 F 1 1 WINDOW SCHEDULE 'J JOB SITE/ADDRESS: )l A r L 1 c.e PL DATE: OWNER: APPLICATION NO.: WINDOW- UNIT OR CLEAR CLEAR WINDOW STOCK ROUGH ROUGH SQ.FT. OPENING N0.OR WINDOW SQ.FT. WIDTH IN OPENING SPECIAL HARDWARE OR VENT MANUFACTURER NUMBER OPENING OPENING EGRESS/CLEAR HEIGHT LETTER NAME MODEL/TYPE CALL WIDTH HEIGHT OPENING IN INSTRUCTIONS ON PLAN SIZE INCHES INCHES IF 1. A-Jevso&1 Double rw2ft'F2 Z'�Gy�N 'h�'l%`► ,17 'f'. 7 27„ CIA C ( I B 26-LTR 1 1-05 _.-____-----_-------..______________, PROJECT NAME: OFFICE USE ONLY ; STAFF INITIALS: ; BUILDING PERMIT SUBMISSION % DATE: CHECKLIST FOR: ' MULTIPLE DWELLING or COMMERCIAL PROJECTS EForms ing Permit Application Completed? YES �NO j N /A gy Form or CheckMate Energy Code Compliance Complete? (2-copies)3 Energy Code Inspector's Report from Checkmate__ _ _ — f Program? (2-copies) 4 I Septic application completely filled out? -------? — --� (if applicable) i 5. Electrical Inspection Form complete? 6. Two (2) sets of the plans each of the following: i YES f NO N /A a. Floor plans (s)? b. Foundation plan? I c. Cross sections (s)? d. Elevations? e. Design loads including floor, snow load, and wind load? f. Seismic design (required after January 2003)? g. Plans signed and sealed by registered architect or engineer? t h. Window and door schedule? II Two (2) site plans showing location of the structure to be 7 ' built, location of well or water lines, location of septic s system or sewer line with all setbacks and separation distances shown, and all improvements to the propeqr.. I I 8. Solid Fuel Burning or Gas Appliance Form (if applicable)? I 9. Driveway Permit I Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 �f-371 ---------------- OFFICE USE ONLY ; PROJECT NAME: STAFF INITIALS: BUILDING PERMIT SUBMISSION DATE: CHECKLIST FOR: ' SINGLE FAMILY DWELLING 1. Building Permit Application Completed? r!ES)1 NO N /A 2 Energy Form or CheckMate Energy Code Compliance ! -----j -- 2 f Forms Complete? (2-copies) 1 ; Energy Code Inspector's Report from Checkmate 3. ; (2-copies) Program? o e { _ _ 9_—_( __ ._.__......-.___._._.....--.-.-.--------.--._..............___....._._ _._.............. i Septic application completely filled out? I 4' ` (if applicable) i 5. ' Electrical Inspection Form complete? j 6. I Two (2) sets of the plans each of the following: ? ES NO ! N /A ! t i ; j i a. Floor plans (s)? X b. Foundation plan? ' ; IC. Cross sections (s)? ............ _..-..............._........._.. d. Elevations? j r : x ( e. Window and door schedule? f. Natural Light, Ventilation and Emergency Egress _ Requirements?_ g. Plans signed and sealed by registered architect or engineer? Two (2) site plans showing location of the structure to be — 7. ' built, location of well or water lines, location of septic X system or sewer line? 8. Setbacks from property lines to new structure? 8 ► Setbacks to neighboring wells and septic systems, including onsite well and septic s stems if applicable)? 9. 1 Driveway Permit? Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 B 12-LTR 11-05 ------ OFFICE USE ONLY .....-._... TAX MAP NO. PERMIT NO._��V �i < -- - 1 „ r 0 f7 FEES: PERMIT RECREATION ENGINEERING ' (If applicable) Oo ; ..: - PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: F{o�+�n_�owH Caaffrvc�-got, OWNER: y r ✓ doe 1 i64o / „_4r- ADDRESS: 2zk F- C—j,,a rc.I Rel. . &I F ) Rj ADDRESS: f}fA 1eT PC. a e�„ PHONE NOS.99 3-7 !r2 y- lcell - 495_y-87/ PHONE NOS. 9 3 - '?S3 Z 7Y-S- 8 ZI CONTACT PERSON FOR BUILDING & CODES COMPLIANCE: 7eL., Mv..,Wc, PHONE: 973-7/ 9 y- LOCATION OF PROPERTY: (_( _ As0ey PL Q .�ce�rbv►^y SUBDIVISION NAME: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT z oLL APPLY TO YOUR z p a d W L'- PROJECT 0 p OJ O = _ w -, u- LL u- w Q a_ O U W 0 � � d z d F=- t- Or w z 4 Q cn N U) O u- u- a = 06 SINGLE FAMILY x 3 ? Z 3 r z TWO-FAMILY MULTI-FAMILY (NO. of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: IVA ESTIMATED CONSTRUCTION COST: �,s6;OD©, O o _ _ FUEL TYPE: n a s HEAT TYPE: "HOW MANY FIREPLACE(S): AND /OR WOODSTOVES(S): n ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? No IS THIS A HISTORIC SITE? No PROPOSED USE OF BUILDING OR ADDITION: F= w, ' (Pv — `Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office B 3-LGL t t-05 QTown of Queensbury - Community Development Office - 742 Bay Road, Queensbury, NY 12804 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? tiro I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Godes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above. Signed Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) ...................... Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. 10 Application: ; 00 10 BUILDING & CODES APPROVAL ; ZONING APPROVAL , , / 0 , , DOE 0 , ' DATE , QUESTIONS? CALL 661-8256 OR EMAIL codesftclueensbury.net VISIT OUR WESSITE FOR MORE INFORMATION Office Use Only www.gueensbury.net Operating Permit Issued: -� Yes No y Occupancy Type: Construction Classification Assembly Occupancy Limit: Special Conditions: Town of Queensburyy - Community Development Office - 742 Bay Road, Queensburyj, NY 12804 f . td2v� 2 -Z/ we-jl,esd Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: �` • aml{�m,/ pepart: am/pm Date Inspection request received: Inspectors Initials: IL �i NAME: PERMIT#: LOCATION: r DATE: — TYPE OF STRUCTURE: Comments: Y N NIA 4' Building Number Address visible from road Chimney Height/"B'Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs deckspatios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Brawn /Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to silt plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 s .ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 s .ft. Emergency ress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'A"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct worts Sealed properly Gas Loge in Sealed or Glass 4Encdlu Final Electrical Final Survey Plot Plan 10 Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Sepfic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if reqwired Okay to issue C/C or C 10[Temporary/Permanent LABuilding&Codes Forms\Building&Codes\Inspection FormsWesidential Final Inspection Form revised_100405.doc;Revised January 7,2008; Revised 6/26/08 Framing / Firestopping Inspection R rt Office No. (518)761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive:-ZLAL—am/ Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: � NAME: PERMIT# LOCATI INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS: Framing minimum Jack Studs/Headers �1 Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12 O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Hales/Bearing Walls Metal Strapping for Notches Top Plate 1 '/ w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft.floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wail 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. OM 5.7 sf above/below grade 5.0 sf grade LABuilding$Codes Forms-=\Building&CodesNinspection FormsTraming Firestopping Inspection Report.doc Revised January 7,2008 Foundation Inspection Report Office No.(518)761-8256 Date I7o�r'�sl—nifial ti n request received: Queensbury Building&Code Enforcement Arrive am/ t Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 In specs:� NAME: f - 1 1 PERMIT#: LOCATION: - Ll INSPECT ON: _ TYPE OF STRUCTURE: Comments Y N N/A l n Footings c Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundatio pproofin , Foundati at Footing Orain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report-doc Last printed 12/20/2005 9:24:00 AM / '3 /A)�-�7- Foundation Inspection Report Office No.(518)761-8256 Date Ins o"euest received: Queensbury Building&Code Enforcement Arrive: c am/p epart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's 'tials: NAME: I PERMIT#: OR3 LOCATION: INSPECT ON: TYPE OF STRUCTURE: Comments, Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Damwroofij Foundati n Waf6rproofing Footing Drain ay i t or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM D ` A-- Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: !�/ PERMIT#. LOCATION: d INSPECT ON: TYPE OF STRUCTURE: Comments -- Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place 1-7 Footing Dowels or Keyway in place i Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM aS R TOWN OF C UE'EtVSt3tlpY MlijklDINI, Tl�hi_NT Based on our lhrsit.;a examiklatian, compliance with our comments si-tall not be construed a "r�rticatirk�; � - ___._--•--�- pearls and sPecificlflons are in full Compliance with code. i ILI ✓� t, i I 6 e K r \4,• 1 ! t wr 1 g I I J li ' s I r /" 4 Permit# Permit Date NotREScheck Software Version 3.7.3 Compliance Certificate Project Title: Corning Report Date: 07/02/08 Data filename:C:\Documents and Settings\VISION Engineering\My Documents\VISION ENGINEERING\Projects\Projects 2008\Plans\ashley.rck Energy Code: New York State Energy Conservation Construction Code Location: Warren County,New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 22% Heating Degree Days: 7635 Construction Site: Owner/Agent: Designer/Contractor: 11 Ashley Place Queensbury,NY 12801 Assembly . �.. Ceiling 1:Flat Ceiling or Scissor Truss: 370 38.0 0.0 11 Wall 1:Wood Frame, 16"o.c.: 526 19.0 0.0 24 Window 1:Wood Frame:Double Pane with Low-E: 114 0.360 41 Door 1:Solid: 20 0.350 7 Crawl 1:Solid Concrete or Masonry: 234 0.0 10.0 17 Furnace 1:Forced Hot Air:92 AFUE The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to III est of t s/her knowledge,belief,and professional judgment,such plans or specifications are in compliance wit this Code.AA /pc, Buil er/Desig r Company Name Date r v 1 n S\CJr' Corning Page 1 of 4 REScheck Software Version 3.7. Inspection Checklist Date:07/02/08 Ceilings: ❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation Comments: Above-Grade Walls: ❑ Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Windows: ❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.360 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1:Solid,U-factor:0.350 Comments: Crawl Space Walls: ❑ Crawl 1:Solid Concrete or Masonry,4.0'ht/3.0'bg/4.0'insul,R-10.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade) insulation and extends at least 6 in.below grade. Heating and Cooling Equipment: ❑ Furnace 1:Forced Hot Air:92 AFUE or higher Make and Model Number: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: ❑ Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-11. ❑ Return ducts in unconditioned attics or outside the building must be insulated to R-6. ❑ Supply ducts in unconditioned spaces must be insulated to R-11. Coming Page 2 of 4 s ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R- ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R-2. .Insulation is not required on return ducts in basements. Duct Construction: ❑ All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes.Tapes and mastics must be rated UL 181A or UL 18113. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: ❑ Separate electric meters are required for each dwelling unit. Fireplaces: ❑ Fireplaces must be installed with tight fitting non-combustible fireplace doors. ❑ Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. Corning Page 3 of 4 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(°F) 2"Runouts 1"and Less 1.25'to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Corning ..Page 4 of 4