Loading...
2008-410 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20080410 Date Issued: Tuesday, August 12, 2008 This is to certify that work requested to be done as shown by Permit Number P20080410 has been completed. Tax Map Number: 523400-239-007-0001-025-000-0000 Location: 139 ASSEMBLY PT. Rd Owner: MARY TRELLO LIFE USE Applicant: MARY TRELLO LIFE USE This structure may be occupied as a: Septic Alteration Residential By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, " lot Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20080410 Application Number. A20080410 Tax Map No: 523400-239-007-0001-025-000-0000 Permission is hereby granted to: MARY TRELLO LIFE USE For property located at: 139 ASSEMBLY PT. Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Tyne of Construction Value Owner Address: MARY TRELLO LIFE USE Septic Alteration Residential ANTHONY TRELLO Total Value 82 MAIN Sq C HUDSON FALLS,NY 12839-0000 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2008-410 SEPTIC ALTERATION RESIDENTIAL $25.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Friday, August 07, 2009 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at reTow �f* kry ay,August 07, 2008 SIGNED BY for the Town of Queensbury. 7� Director of Building&Code Enforcement .....r..rrr....r.. . .....r r r.._.r_r.r. rr._..... .__..__r r.r ........_rrr.r.r. L=i., OFFICE USE ONLY ' 2 ; Tt + � A A� N0. PE IT NO. RMIT FEE , + APPROVALS: ZONING TOWN CLERK_ ; .__r.................................................. APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT} A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. _ c OWNER: % y INSTALLER: ADDRESS: f C� �L ��/ ADDRESS: � L/. r J// PHONE NOS. -:6664 PHONE NOS. �� SI t LOCATION OF INSTALLATION: Z A ��_ r J ........................................................................... ........................................................... RESIDENCE INFORMATION YEAR BUILT NO.OF X COMPUTATION= _ TOTAL DAILY FLOW ; I............................................... ......BEDROOMS,......I...........k' ; r .i GARBAGE GRIN E 1980 or older X i 150�Iallon per bedroom = ' I INSTALLED? ............................................:....................� -. ,...................;..............,..g.............R..............,,....................a,.,........I......3'0.l...^............................................I 1981 1991 X , 130 gallon per bedroom , { t I = i SPA OR HOT TU8 j...................:..........................................................,..............t..........,a..............................,:.............,...............,......................;.........,....,................................ ..........,.,.............,; 1992 present X j 110 gallon per bedroom INSTALLED? PARCEL INFORMATION: /K ✓ TOPOGRAPHY: FLAT ROLLING'- STEEP SLOPE/ Z %SLOPE. ` l ✓ SOIL NATURE: SAND LOAWd- CLAY OTHER ✓ GROUNDWATER: AT WHAT DEPTH?" BEDROCKAMPERVIOUS MATERIAL: AT WHAT DEPTH? ✓ DOMESTIC WATER SUPLY: MUNICIPAL WELL, (IF WELL:WATER SUPPLY FROM ANY SEPTIC-SYSTEM ABSORPTION IS FT.-) ✓ PERCOLATION TEST: RATE IS PER MIINUTE PER INCH (TEST TO BE COMPLETED BY A LICENSED PROFESSIONAL ENGINEER OR ARCHITECT) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect (unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each garbage grinder, spa or whirlpool tub. ✓ SEPTIC TANKJN�r_GALLON (MIN. SIZE IS 1,000 GAL.) TILE FIELQ: EACH TRENCH FT. ✓ TOTAL SYSTEM LENGTH: FT. SEEPAGE PIT(S): HOW MANY? ✓ SIZE OF EACH.. T. X FT. ✓ SIZE OF STONE TO BE USED: # /DEPTH OP THICKNESS_C'LFT. ✓ BED SYSTEM_SIZE: X ✓ ALTERNATIVE SYSTEM: LENGTH ANDJOR SIZE ✓ HOLDING TANK SYSTEM:(If required) NO. OF TANKS: /SIZE OF EACH l� ✓ GALLONS./TOTAL CAPACITY: GAL. ......:..::................................... ..,..::,.,,, :.,:,,:.:,..i il NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and S? CALL 761-8256 OR EMAIL agree to abide by these and all requirements of the Town of Queensbury Sani ry Sewage Disposal Ordinance. COUO"T'oc-:'odes§ciueonsbury.not SIT UR BSITE FOR MORE INFORMATION www.aueensbury.net Signa ure of Person Responsible Date QTown of Queensbury • Community Development Office - 742 Bay Road, Queensbury, NY 12804 Septic Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/gym part: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: NAME: �� PERMIT NO.: LOCATION: f q INSPECT ON: RECHECK: Comments and/or diagram Soil Type: Sand oa C Type of Water: Municipal Well ater Waterline separation distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' + J - Y N N/A Absorption Field: Total length A-- Length of each trench Ak Depth of trenches ft. ����;' Loco Size of Stone Seepage Pits: Number Size: x Stone Size: Piping ize Type ! - Building to tank Tank to Distribution Box kA Distribution Box to Field/ Pit KITA 'TT) Opening Sealed: AY fN� End Cap _Y X Inlet/Outlet Pipes&Baffles Y Location/ Separations Foundation to tank Foundation to absorption Separation of Pits ft. Conforms as per Plot Plan _Y_ N Engineer Report and As-Built Y N Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear 5y5jem Use s• Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Last revised 06/18/07 U\Building&Codes Forms-01-1)\Building&Codes\Inspection Forms\Septic Inspection Report.doc a 9 Septic Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: pp NAME: ^��"� PERMIT NO.: -4 l o LOCATION: Ir% INSPECT ON: CJ RECHECK: Comments and/or diagram Soil Type: Sand/ Tpe of Water: Municipal Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' + / - Y N N/A _ <t'� Absorption Field: Total length ft 'l�" Length of each trench ft. � �� Depth of trenches ft. Size of Stone ('0/,-Z)o Seepage Pits. Number L Size: x Stone Size:I— Piping Size Type Building to tank ��� 2L Tank to Distribution Box A Distribution Box to Field Pit 1 Opening Sealed: Y N t(� End Cap N Inlet/Outlet Pipes&Baffles Location/ Separations Foundation to tank Foundation to absorption ft— Separation of Pits ft. Conforms as per Plot Plan Y N Engineer Report and As-Built J Y N Location of System on Property: Front R a Left Side Right Side Middle Fron Middle Rear 5ystemUse S s: Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Last revised 06/18/07 L:\Building&Codes Forms-OLD\Building&Codes\Inspection Forms\Septic Inspection Report.doc Details ProOded by APPIAN Consulting Engineers — www.oppianengineers_com 12105/2005 — 10,a7:05 AM HORIZONTAL STRUCTURAL REINFORCING RIBS GAS(TOP)1 LIQUID(BOTTOM) 'T�R t (FULL CIRCUMFERENCE) PASS THRU SLOT INSIDE TANK c l � {�^ LIFTING Ct V<) HOLES 6 (4 TYPICAL) a THREADED 6 ACCESS o :3 OPENING 24"I.Q.DMA. a (2 TYPICAL) I 3 E rq m m Q o C5 m 4.25"TYP. 29 4 2"TYP. to � LENGTH=11I3" ca d WIDTH=627 8.66" t r- r it SEPTIC TANK SPECS w z 3 DESIGN CAPACITY TOTAL CAPACITY WEIGHT (A GALLONS LITERS GALLONS LITERS POUNDS 0° 1000 3780 114 1 4340 450 SIDE SEF TE H TANK cm0� U e ' "` ' '� 1000 GALLON / 1Y ODEL ST-1000E S3vacuaeN_Y.733J06 Cult Tad Fies86fi.At�7�ti i OF 3 THE 11 W T�.>! ENA""M M1 OF Of 8rM W STEUM"M PRODIJ'OZ°9i www.fialanu DetailLs Provided by APPIAN! Consulting Engineers ww&v,appianengirneem corn 12/06/2M — 10.137-05 AV ELEVATION C INLET POW OUTLET FORT N G us 0: q r� Q) w 11 G Cz m m LENG'FH 1 IS" :z THREADED ACCESS THREADED ACCESS INLET POW OPENING OPENING OUTLET PORT 24"I.D.DIA. 24'I.D.OW w! INV IN. INV OUT 42"LIQUID LEVEL (SEE LOCAL BEGS.) OPTIONAL PARTITION WALL Fll SEE LOCAL REDS. FOR OPENING REQUIREMENT a in in in 213 TANK LENGTH Go 113 TANK LENGTH (A 42" LIQUID LEVEL HORIZONTAL STRUCTURAL REINFORCING SECTION A RIBS(FULL CIRCUMFERENCE) MALO 3EASEEM SEPTECHmm TANK isemadmODMD&C ry AnIrSWCAILF: I Syracuse NLY.IMM 1000 N / MODEL ST-I OOOE TMR0086043XV6 SHEErA C� .2 oF 9 THE NEWT ZRAIMN OF ONS]rFF—WAZTEWATM P9ROD&MM -vVJWWJwWCmK1m13 Detoils Provided by APPIAN Consulting Engineers — www.n$pionengineers_corn 12/06/2005 — IQ D7-05 AM HORIZONTAL STRUCTURAL REINFORCING RIBS ISOMETRIC (FULL CIRCUMFERENCE) 1 GAS(TOP)!LIQUID(BOTTOM) PASS THRU SLOT INSIDE TANK a MULTI PORT CKJTLETS V THREADED ACCESS OPENING (3 TYPICAL) 24"IA.DIA.(2 TYPICAL) LIFTING HOLES (4 TYPICAL) M ta ao MULTI PORT C INLETS z (3 TYPICAL) m A SEPTIC TANK NOTES 1. Access at or above grade level must be secured against unauthorized access. 2. Tank is not rated for vehicular traffic loading. 3. All resin used is compliant with ASTM D 1248 as required by CSA B66 and IAPM0 PS 1-2004e1. 4. Tank material of construction is HM'w'4,t-HDPE. .5. Primary dimensions are in inches 6. Minimum tank wall thickness is 114". 7. Labeling will include: manufacturer name, liquid capacity, date, maximum burial depth, and model number. 8. Riser cover contains the following: W x 3" warning: :z "Danger-Do not enter-Poison Gas" -written in English, French&Spanish. 9. Maximum burial depth from manufacturer is 36"unless specifically instructed otherwise by the factory. (A 10. Models ST 750,ST 1060, ST 1250 and ST-1500 are all certified to CSA and lAPM0 standards- NOTES 11. Models ST-500,ST-900 and ST-10UQE are compliant with CSA and IAPMO standards. T W 779i1[}9['ali,E 7 1 ,�"tEPTECH Tm TANK V LOT WAM- 12 1000 GALLON l MODEL ST- I OOOE �[ieaerad�oaysDrne 8H®'sT& S�,aacn�2I.Y.132D6 Gbll Toll Flee Af6.943.T+ 6 3 of 3 THE NEXF Oi EME111AMO U OF ON$riB WASTL MTKR PRODIJOIS wawfie�waet - . ;r}.�„--tea - - - - �, � the seen-or observed; or believe 1 . saw evidence of, am objects such as houses, wells trees, fences,etc., ;.shown a�this document. t also represent that 1 have ll Personay meas ed the di tances set fort , h on the diagram." rn ., • a . SIGNATURE �O DATE 'Vt b 5`I ;3 - l000 G A a o r,1 W _ _ s c- �� aA S MP'-Tl 2-3 �c 8t PA V—6A sue- Gc�C. T -el ZLL