Loading...
BINS-000359-2019 01172019 INSPECTION WORKSHEET (BINS-000359-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal CC-000364-2016Permit Case Number:Case Module: Thu Jan 17, 2019Partial Pass Inspection Date:Inspection Status: John O'BrienBuilding Framing Inspector:Inspection Type: 27, 29, 33, 35, 39, 41, 45, 47 Wedgewood302.9-1-28.1 Job Address:Parcel Number: DR Bldg. 3 Queensbury, NY 12804 Contact TypeCompany NameName ArchitectRucinski-Hall Architecture Primary OwnerSCHERMERHORN WEDGEWOOD LLC ApplicantSchermerhorn R.E. HoldingsVANDERWARKER, DARREN ContractorSchermerhorn R.E. HoldingsVANDERWARKER, DARREN Granted PermissionSchermerhorn R.E. HoldingsVANDERWARKER, DARREN Checklist ItemPassedComments Building Inspector NotesNO6/15/18 Ice & Water Shield Partial Approval -Upper roof ok to shingle. I will check the balance on Monday 6/18/18 6/18/18 Ice & Water Shield Approved-Balance 1/17/19 Framing Partial Approval - Preliminary Framing - Garage anchor bolts are missing in areas. They do not meet 6' oc or less spacing. Spliced bottom plate anchoring ok. - Check stair landings for missing joist hangers - Bridging missing at outside box area and in middle spans. Just recheck after trades are done. - Complete nailing all truss bracing at gable ends and at changes to different truss locations. Some areas are missing nailer blocks totally and some blocks are there but are not nailed . Jan 17, 2019Page (1) INSPECTION WORKSHEET (BINS-000359-2019) Checklist ItemPassedComments - Refer to my previous note on 1/15/19 regarding hold down locations to be verified by Ethan Hall. FramingNO1/17/19 Framing Partial Approval - Preliminary Framing - Garage anchor bolts are missing in areas. They do not meet 6' oc or less spacing. Spliced bottom plate anchoring ok. - Check stair landings for missing joist hangers - Bridging missing at outside box area and in middle spans. Just recheck after trades are done. - Complete nailing all truss bracing at gable ends and at changes to different truss locations. Some areas are missing nailer blocks totally and some blocks are there but are not nailed . - Refer to my previous note on 1/15/19 regarding hold down locations to be verified by Ethan Hall. Attic Access 22 x 30 minimumNO Jack Studs HeadersNO Continuous Header for Garage Doors withNO Straping Truss Specification ProvidedNO Bracing BridgingNO Hurricane Clips/Uplift Screws/Nail Holes FilledNO Air Seal all Plates and SillsNO Air Seal All Registers at FloorNO Jan 17, 2019Page (2) INSPECTION WORKSHEET (BINS-000359-2019) Checklist ItemPassedComments Air Sealing all Joints Before InsulationNO Joist hangersNO Jack Posts Main BeamsNO Exterior sheeting nailed properlyNO 12 O.C.NO Headroom 6 ft. 8 in.NO Notches Holes Bearing WallsNO Metal Strapping for Notches Top PlateNO Draft stopping 1,000 sq. ft. floor trussesNO Anchor Bolts 6 ft. or less on centerNO Ice and water shield 24 inches from wallYES6/15/18 Ice & Water Shield Partial Approval -Upper roof ok to shingle. I will check the balance on Monday 6/18/18 6/18/18 Ice & Water Shield Approved-Balance Soffits-Insulation BaffelNO Windows Habitable Space BedroomsNO 24 in. (H)NO 20 in. (W)NO Jan 17, 2019Page (3) INSPECTION WORKSHEET (BINS-000359-2019) Checklist ItemPassedComments 5.7 sf above below gradeNO 5.0 sf gradeNO Design Professional Sign-off, if requiredNO O'Brien, John (Inspector) Jan 17, 2019Page (4)