Loading...
Signed Inspection Report (02-03-2020) (16).pdfINSPECTION WORKSHEET (BINS-000703-2020) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:AST-0593-2019 Case Module:Permit Inspection Date:Mon Feb 3, 2020 Inspection Status:Failed Inspector:John O'Brien Inspection Type:Building Insulation Job Address:Parcel Number:133 Jenkinsville RD Queensbury, NY, 12804 279.-1-21 Contact Type Company Name Name Architect Rucinski-Hall Architecture Concrete Contractor A.J. Catalfamo Construction Co., Inc. Granted Permission TOWN OF QUEENSBURY REC DEPT Primary Owner TOWN OF QUEENSBURY REC DEPT Checklist Item Status Building Inspector Notes Failed 2/3/20 Insulation Not Approved Remaining Items: - Remove a sheet of fire retardant plywood from each wall to verify the insulation in wall has been installed correctly. - Provide documentation that states that R38 insulation has been installed in ceiling and R21 has been installed in the exterior walls as per the approved COMcheck Energy Code Compliance Report. - Provide documentation that the windows and insulated door have the correct U value as per the approved COMcheck Energy Code Compliance Report. Window Sealing Failed U Factors = .3 cfm for windows, .5 cfm for doors Failed Feb 03, 2020 Page (1) INSPECTION WORKSHEET (BINS-000703-2020) Checklist Item Status Insulation Residential Check Commercial Check Failed 2/3/20 Insulation Not Approved Remaining Items: - Remove a sheet of fire retardant plywood from each wall to verify the insulation in wall has been installed correctly. - Provide documentation that states that R38 insulation has been installed in ceiling and R21 has been installed in the exterior walls as per the approved COMcheck Energy Code Compliance Report. - Provide documentation that the windows and insulated door have the correct U value as per the approved COMcheck Energy Code Compliance Report. Blower Door Test Failed Combustion Air Supply for Furnace Failed Fresh air supply 3' from grade Failed Duct Insulation - if required in unheated spaces Failed Door / Window Sealed (No Insulation)Failed Tub Shower R-20 with Vapor Barrier Failed Air Barrier behind Knee Walls Failed All Ductwork Sealed Return and Supply Failed Duct Blaster Test for duct work, R-8 Failed Feb 03, 2020 Page (2) INSPECTION WORKSHEET (BINS-000703-2020) Checklist Item Status All Return Air Hard Duct Work Failed House Wrap Taped at all Seams Failed Feb 03, 2020 Page (3) O'Brien, John