2008-443 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20080443 Date Issued: Thursday, August 06, 2009
This is to certify that work requested to be done as shown by Permit Number P20080443
has been completed.
Location: 14 TROUT PAVILION Rd
Tax Map Number: 523400-227-010-0001-027-000-0000
Owner: TROUT PAVILION INC.
Applicant: TROUT PAVILION INC.
This structure may be occupied as a:
Deck By Order of Town Board
Residential Addition TOWN OF QUEENSBURY
Residential Alteration
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20080443 Application Number. A20080443
Tax Map No: 523400-227-010-0001-027-000-0000
Permission is hereby granted to: TROUT PAVILION INC.
For property located at: 14 TROUT PAVILION Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: TROUT PAVILION INC.
C/O GEORGE ARAKELIAN Deck
750 SECOND Residential Addition
TROY,NY 121 Aveve Residential Alteration $100,000.00
Total Value $100,000.00
Contractor or Builder's Name/ Address Electrical Inspection Agency
Plans &Specifications
$133.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Saturday, September 12, 2009
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the To o eens ry,4 �41° ptember 12, 2008
�• ,,
SIGNED BY ��" for the Town of Queensbury.
Director of Building&Code Enforcement
%.................................................................................., r........................
OFFICE USE ONLY ;
'7 r
TAX MAP N0. `�`9�' l�� -j-�'"l PERMIT NO.
01
S .n 0
o FEES: PERMIT_�3 RECREATION ENGINEERING ' ;
(if applicable) ; ;
PRINCIPAL STRUCTURE:
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO
REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION..
APPLICANT/BUILDER: DM G Cg KYT(ZA cr1a)F.+— OWNER: 6eo rI e 6,e 4k 401 a
ii � p L 0 lfl c.l<o✓L d �j2ok! PAO,
ADDRESS: I Y ADDRESS:
21 60
PHONE NOS. .S�< �f�L Ga.S� PHONE NOS. 3 16 ? 5 3 S
CONTACT PERSON FOR BUILDING &CODES COMPLIANCE: �'�` �u�i PHONE: y-
LOCATION OF PROPERTY: 12a�� Pet U L
SUBDIVISION NAME:
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT o +-
APPLY TO YOUR f- O a cwn U.
W
PROJECT p 0 w Q d = v
0
u- u
Z Q c- d Na Ou- � � a = �s
SINGLE FAMILY
TWO-FAMILY
MULTI-FAMILY
(NO.of UNITS )
TOWNHOUSE
BUSINESS OFFICE
RETAIL-
MERCANTILE
FACTORY OR
INDUSTRIAL
ATTACHED
GARAGE(1,2,3) Q
OTHER ( Deck, ,
IF COMMERCIAL OR INDUSTRIAL—NAME}} OF BUSINESS:
ESTIMATED CONSTRUCTION COST: i®Q t 8t7��o FUEL TYPE:
HEAT TYPE: 14D f 41k 'HOW MANY FIREPLACE(S): �`- AND/OR WOODSTOVES(S): �
ZONING CATEGORY: A ARE THERE WETLANDS ON THIS SITE?
IS THIS A HISTORIC SITE?
PROPOSED USE OF BUILDING OR ADDITION: �u t"`'""--r C4pne
*please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office B 3-LGL 11-05
Town of Queensbury • Communit i Development Office - 742 Bau Road. Dueen.shijrii NY 19R0a
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? N 0
ARE THERE EASEMENTS ON PROPERTY? WO
I acknowledge no construction activities shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete statement/description of the work proposed, that all work will be performed in
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read andanree to the above.
Signed
Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction
codes or septic systems)
Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process,
application requirements or to schedule an appointment)
................................oo ;
S
Permission is hereby granted to the above ; This application / proposed action described
Applicant to erect or alter the building ; ; herein is found to be in accordance with the
described herein in accordance with said zoning Laws of the Town of Queensbury.
Application: 11
,
,
,
S
BUILDING & CODES APPROVAL ; ZONING APPROVAL ,
,
11
DATE 0 '
DATE 11
i...................................................: .....................................................0
8256 OR EMAILurv.netOffice Use Only (QUESTIONS
RE INFORMATIONury.net
Operating Permit Issued: Yes No
Occupancy Type: Construction Classification:
Assembly Occupancy Limit: Special Conditions:
QTouin of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518) 761-8256 Arrive: q- 4 am/p part: a/
Date Inspection request received: Inspector's Initials: \
NAME: PERMIT#: _ l
LOCATION: DATE:
TYPE OF STRUCTURE:
Comments:
Y No NIA
4' Building Number Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake _
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs decks atios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ram Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to silt plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen waterti ht
Safety glazing/Window in stairwells safety glazing
tenor Smoke Detectors/Cartoon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches (height in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
throom Fans,if no window
Plumbing fixtures
Foundation insulation/Insulation Certification
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency ress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water..Temp 110
Enclosed Stairs Sheetrock Underside minimum'A"Gypsum
Basement stairs dosed rise>4 inches
Garage Floor Pitched
Garage fire roofi /'/.hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
final Survey Plot Plan
Arc Fault Breaker in Bedrooms
Flex Gas Pipe Bondin
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C 10 1 Temporary/Permanent
LABuilding 8 Codes Forms\Building&Codesllnspecbon FormslResidential Final Inspection Form_revised_100405.doc;Revised
January 7,2008; Revised 6/26/08
Queensbury Buildin .& Code Enforcement c KZsldentiai Final Inspection
Office No. (518) 761-8256 Arrive: am/
dr►� &D part: am/pm
Date Inspection request received: Inspector's initials: �J
NAME: PERMIT#:
LOCATION: DATE:
TYPE OF STRUCTURE:
Comments:
N !A
,V Building Number Address visible from road
Chimney Height/'B'Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors _
Handrail 4 or more risers
Guards at stairs deckspatios more than 30 inches above rade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Raflfn s 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate _
Gas Valve shut-off a ed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safe glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom: P� ��AL)
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq,ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation/Insulation CertificationuL��
Floor truss,draft stoppiEg finished basement 1,000 s .ft.
Emeraency egress below grade U
Gas Furnace shut-off within 30 feet or within tine of site Z-7
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetroclk Underside minimum IN Gypsum_
Basement stairs dosed rise>4 inches
Gara a Floor Pitched
Gars a fire roofi /' hour fire door/door closer
Duct work Sealed prop2rly
Gas Logo in Sealed or Glas# nclosure
Final Electrical
Final Surve Plot Y
Are Fault Breaker in Bedrooms KG-iKIQG 1'A'�L i C-G 5
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance r uired
Flood Plain Certification,if required _
Okay to issue C/C or C/® Temporary/Permanent
LABuilding&Codes Form"uilding&Codes\lnspec ion FormsWesfdential Final Inspection Forrn_revised 100405.doc;Revised
January 7,2008;Revised 6/26/08
• Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date Ins request received:
Queensbury Building&Code Enforcement Arrive. Mam/ rt: am/pm
742 Day Road, Queensbury, NY 12804 Inspector's Initials: v
NAME: �c2��(K�9 L_1!� PERMIT
LOCATION: t AV, VD INSPECT ON: c�
TYPE OF STRUCTURE:
rr
r
Y A N I WA COMMENTS:
Framing
Attic Access 22' x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12" O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 'h w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (V1l)
5.7 sf above/below grade
5.0 sf grade
L:1Build'mg&Codes Form8-=M3uildiN&CodesMrapection FomaTraming Firedoppirg Inspection ReW doc Revised January 7,2008
�) �w � kzk-,,
�Framing / Firestopp glnspect� n Re I?fOffice No. (518) 781-8256 Date I request received:
Queensbury Building&Code Enforcement Arrive: am/ Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspecto Initials: , t'
NAME: :TO07� TPERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N NIA COMMENTS:
Framing
ss 22" x 3T minimum
Jack Studs/Headers l �rL.,� L j L a A O
Bracing/Bridging
Joist hangers
Jadc Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Dedc Bracing
Headroom 8 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 h w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 518 inch Type X
Garage side 518 inch Type X
CeilingAyall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. W
5.7 sf above/below grade
5.0 sf grade
LAWWW*&Codes Forms-OLDiBu"M9&CodoMrfspedion FormTrarrinp Frestoppmg Inspec bon Raport.doc Revised Janwry 7,20M
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date Inspen request received:
Queensbury Building&Code Enforcement Arrive:L-3• am/ , Depart: am/pm
742 Bay Road, Queensbury, NY 12804 InspectoAs initials: �
NAME: jtz&(-&
14x PERMIT#:
LOCATION: ✓)75-7 INSPECT ON: t t 0
TYPE OF STRUCTURE:
Framing Y N WA COMMENTS
Attic Access 22" x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12" O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
t!chor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceilingfwall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (M
5.7 sf above/below grade
5.0 sf grade
L:\Buikkq&Codes Forms-OLMSuNdkV&Codeslinspedion ForrnsTrarning FuedOpping inspection Reportdoc Revised January 7,2006
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received: C1
Queensbury Building&Code Enforcement Arrive: am/ m Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector' Initials: 2
NAME: UNl — �`�' �-*� PERMIT#: 6T
LOCATION: w INSPECT ON:
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
iers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofng
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
i
L:\Building&Codes Forms\Building&Codes\Inspecti Forms\Foundation Inspection Re doc
Las printed 12/20/2005 9:24:00 AM
t �'�
;_. WORK REQ`VEST
CLIENT: tyJ
ADDRESS: 41
r
Of Northeastern New rk, Inc. DATE: 1,
4 Phillip Drive
Malta, NY 12020 PHONE:
Phone: 518-330-7631 Fax: 518-330-7631 CONTACT:
TYPE OF PROJECT
QTY CATEGORY GALV BLACK FIXED H ADJ H EXT
X X
SKETCH OF WORKSITE
r
7ic
MAPPING OF POST
ROTARY GEARBOX OMS 125 CMS 200 OMS250 A 50
NUM# PSI CAPACITY DEPT HAMMER SINK
IvA -Et-
0(X�
1 e1 c aj 5
4
LV
r
SIGNATURE OF INSTALLER:
CUSTOMER'S SIGNATURE:
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: U am/pm i art: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: PERMIT #:
LOCATION: �� J, ►�,� 2,� INSPECT ON: 3
TYPE OF STRUCTURE:
_ Y N NIA
Bough Plumbing /Nail Plates
Plumbing Vent/Vents in Place
1 % inch minimum Drain Size
Washi2q Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
50 P.S.I for 15 minutes
Insulation/Residential Check/Commercial Check
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing Insulation R revised f�ov 17 2003, revised February 15,2005, revised January 7,2008
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date lnspedior�yTequest received:
Queensbury Building &Code Enforcement Arrive: . 0 am/pm 2epart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspecto Asir
NAME: e' PERMIT#:
LOCATION: ,7 r INSPECT ON: ?
TYPE OF STRUCTURE:
Yyj NIA COMMENTS:
Framing I
Attic Access 22" x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 'h w 16 gauge 8 16D nadls each side
Draft stopping 1,000 sq.ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceilingtwall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. CM
5.7 sf above/below grade
5.0 sf grade
LASuiiding&Codes Fortes-OLMSuiiding&CodesUnspection F -rung�ing I January 7,2008
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspen request received:
Queensbury Building Code Enforcement Arrive: amlp Depa am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: _ `��-
NAME:.i2G}/�C-�- /✓�N PERMIT #: o� �
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
Rough Plumbing /Nail Plates
Plumbing Vent/Vents in Place
1 % inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet I change of direction
Pressure Test
Drain/Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
afar Supply Piping
Air/Head
50 P.S.I for 15 minutes
Insulation/Residential Check/Commercial Check
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct of Water Piping insulation
If uired unheated spaces
bustion Air Supply for Furnace
.7cl work sealed ro /No duct tape
10
-L V
COMMENTS:
Rough Plumbing Insulation Reportrevised Nov 17 2003, revised February 15,2005, revised January 7,2008
Rough Plumbing / Insulation Inspecti n Report
Office No. (518) 761-8256 Date Inspection request received: 1(7.—
Queensbury Building &Code Enforcement Arrive. 'J am/
P i. Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Insp is Initials:,, u -L'
NAME.: , IkA 1 f'l; PERMIT#:
�_
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
Rough Plumbing /Nail Plates
Plumbing Vent/Vents in Place
1 Y2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
[_Airl"
ead
r 15 minutes
nsulation Residential Check/Commercial Check
Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/ No duct toe j
t6OMMENTS:
Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/ Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials
NAME: Aft k u-'C—.4 A ' PERMIT#:
LOCATION: INSPECT ON: ICE
TYPE OF STRUCTURE:
Y N N/A COMMENTS•
Framing
Attic Access 22"x 30" minimum ,%�
Jack Studs!Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12" O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
1re'
wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in Cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
CeifingANall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LABuilding$Codes Farms-OLDSuilding;&CodesYnspedion ForrnsTrarning Firestoppft Inspection Report.doc Revised January 7,2006
Rough Plumbing / Insulation Inspect on Report
Office No. (518) 761-8256 Date Imesinifials:
request received:
Queensbury Building & Code Enforcement Arriveam/�� Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Ins �'"
Z
NAME: .i M L
I,r i ;t rakeP
__
LOCATIO ` - - 7-�; INSPECT ON: �" ,
/mac%
TYPE OF STRUCTUREu:
Y NIA
Rougo Plumbing/Mail Plates ,
PlumbkayenVVents in Place
1 Y2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
C!aanout every 100 feet/change of direction
,Pressure Test
Drain /Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/ Head
50 P.S.I for 15 minutes
Insulation/ Residential Check/Commercial Check
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct/ Hot Water Piping Insulation
If required unheated spaces
C mbustion Air Supply for Furnace
uct wolk sealed properly/No duct tape
7 J
C MMEN rS-.
Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008
Framing / Firestopping Inspectio eport
Office No. (518)761-8256 Date inspection nsquest nCei-vech'
Queensbury Building &Code Enforcement Arrive: Z ?zL( arrtl� Qopgrt:
742 Bay Road, Queensbury, NY 12804 Inspector's Initials. .
f
f ,
NAME: kakd"a PERMIT
LOCATION: INSPECT ON: -
TYPE OF STRUCTURE:
Framing Y N N/A COMMENTS
ccess 22'x 3W minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 'h w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wail
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 518 inch Type X
Ceiling1wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. IM
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes Forms-OI.Dftilding&CodesNinspedion Forms'Freff*q Fi edopp ft inspection Repwtdoc Revised January 7,2008
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date Inspoction rpquest received:
Queensbury Building &Code Enforcement Arrive: Zepart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector' Initials:
NAME: aL L-- -1 � PERMIT#: 19
LOCATION: i` 0'i i INSPECT ON: c?It
TYPE OF STRUCTURE:
Framing Y N NIA COMMENTS:
Attic Access 220 x 3W minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
r Bolts 6 ft. or less on center
ce and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 518 inch Type X
Ceiling1wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes Forms-OLD Suild ft&CodesUnspection FamsTren ing Fxestopping Inspection Repatdoc Revised January 7,20M
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date ins uest received:
Queensbury Building &Code Enforcement Arrive: part: am/pm
742 Bay Road, Queensbury, NY 12804 Inspecto s Initials: `
NAME: R C.L--I/4 N PERMIT
LOCATION: ► oo i s 4 �J INSPECT ON: x
TYPE OF STRUCTURE:
Framing Y N I NIA COMMENTS:
Attic Access 220 x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts I Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 'h w 16 gauge 8 16D nails each side
Draystopping 1,000 sq. ft floor trusses
Bolts 6 ft. or less on center
ce and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side'A inch or 5/8 inch Type X
Garage side 518 inch Type X
Ceilingfwall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. OM
5.7 sf above/below grade
5.0 sf grade
i4L6��nns-oLD'Suilding&CodesiVropection Form arcing F'ntopphV Inspection RepoRAoc Revised January 7,2008
Framing / Firestopping Inspection Report '�7' � ,
Office No. (518)761-8256 Date Ins u received:
Queensbury Building &Code Enforcement Arrive: m/pm part: am/pm
742 Bay Road, Queensbury, NY 12804 Inspect s Initials:
NAME: KGB (&A,) PERMIT#:
LOCATION: 7Ro v i Vic! . 1erD INSPECT ON: /
TYPE OF STRUCTURE:
Framing Y. N I NIA COMMENTS:
Attic Access 22" x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12" O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D naus each side
D pping 1,000 sq. ft. floor trusses
chor Bolts 6 ft. or less on center
ce and water shield 24 inches from wall J
Fire separation 1, 2, 3 hour
Y
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceilingfwall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. ("
5.7 sf above/below grade
5.0 sf grade
14
LABuilding&Codes Forms-OLDSuilding&CodWirapection FomisTrarNng Firestopping Inspection ReporLdoc Revised January 7,2008
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Ins request received:
Queensbury Building &Code Enforcement Arrive: l am/p/n part: am/pm
742 Bay Road, Queensbury, NY 12804 Inspecto s Initials: i
NAME: ._ (A R AV,F L P*) PERMIT
LOCATION: INSPECT ON: 1 -to—0 9
TYPE OF STRUCTURE:
Framing Y N WA COMMENTS:
Attic Access 22' x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D naus each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side h inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
'5.0 sf arade Adr
i
LABuildirm Codes Forms-oLM ilding&Codeslfnsped' Firestopping Inspection ReporLdoc Revised January 7,2008
Framing PP 9/ Firesto in Inspection Re
Office No. (518)761-8256 Date Inspection i ed: t j Jlc. S
Queensbury Building &Code Enforcement Arrive: L pant: a p�n
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: PERMIT#: — y
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N WA COMMENTS:
s AX inimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 'h w 16 gauge 8 16D nails each we
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or lemon center
Ice and water shield 24 inches from3011
Fire separation 1, 2, 3 hour E
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceilingtwall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. W
5.7 sf above/below grade
5.0 sf grade
LABuiiding&Codes Forms4X D18uiid ft&Codesllnspection FomtsTrwr ft Fuestopping Inspection Report.doc R®vised January 7,2006
�li*-- cc;) 10 Inspection Report
Office No.(518)761-8256 Date Inspectloft'request received:
Queensbury Building&Code Enforcement Arrive: i am/pm Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 InspecW s Initials:
NAME: PERMIT#:
LOCATION: L 2 i ,INSPECT ON:
TYPE OF STRUCTURE:
Commenb
Y N N/A
Footings
Monolithic Slab
Reinforcement in Place ,j�
The contractor is respo6ible or
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Buiiding&Codes FormsWiid'ing&Codes\Inspecdon Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report
Office No.(518)761-8256 Date Ins tion reque e _
Queensbury Building&Code Enforcement Arrive: X: Depart: Z`
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initial
NAME: l 14 ERMIT#:
LOCATION: , INSPECT ON:
TYPE OF STRUCTURE:
Con mob
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
6>1
oundation Dampproofing
Foun
Footing Drain Daylight o Sum
noting Drain Stone:
me wi 1/
6 inches above footing
areas under slab
Backfill A val
-� Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspecction Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection epo
Office No.(518)761-8256 Date Ins 'on re . 'iv� :
1� �
Queensbury Building&Code Enforcement Arrive: am/ ` ' Depart: � =
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: /
�rC..r-- - � -
NAME: ��°- P.-�RMIT#: � t
LOCATION: I v, INSPECT ON: �' C"or
TYPE OF STRUCTURE: 9� J--
AJ'j&,d's -, Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
se on site.
Foundation/Wallpou",
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 R.
L:\Building&Codes Forms\Building&Codes\Inspection Foams\Foundation Inspectlon Report.doc
Last printed 12/20/2005 9:24:00 AM
c�o\�ttJ
7-- 4-
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection t
Queensbury Building&Code Enforcement Arrive: pm Depart: b a
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initi
NAME: A W E L�_ RMIT#:
LOCATION: It L4 'TTICYL - ���1 l t p�� INSPECT ON: 1 O —Z4S—Q
TYPE OF STRUCTURE:
COMM10
X
N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofmg
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
U\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
WALTER VANDELOO. P.E., P.C.
Consulting Engineers
P.O.Box 582
Troy,New York 12182-0582
(518)274-4026
October 20„ 2008
Town of Queensbury
Building Department
742 Bay Road
Queensbury,NY 12804
RE:Addition to Arakalian Residence
Gentlemen:
Please note the following changes/modifications to the plans for the above location.
1. The existing roof rafters are to be removed from the entire structure and replaced with Pre-engineered
roof trusses spaced at 24"o/c. Roof trusses to be designed and approved by truss manufacturer and
shall be designed so as to provide the levels of insulation specified on the original drawings.
If you have any questions please feel free to call me at the above number. Thank you for your assistance.
Respectfully submitted,
Walter VanDeLoo,P.E.
WAT TER VANDELOO. P.E., P.C.
f'nis aar�tivrts T,`vrrri�vas-r
P.Q.BOX 582
Troy,New York 12182-0582
(518)274-4026
November 3,2008
To....of Queensbuary
Building Department
742 Bay R-m d
Queensbury,NY 12804
RE:Addition to Arakalian Residence
Gentlemen:
Please note the following changes/modifications to the plans for the above location.
1. Du..ng construction of the....;f undat.on itvraas noted the condition of the existing foundation tss not
stable and must be replaced. The existing foundation shall be replaced by jacking the existing
structure and providing temporary support while a new concrete block foundation is installed per the
attached detail.
If you have any questions please feel free to call me at the above number. Thank you for your assistance.
Respectfully submitted,
Walter VanDeLoo,P.E. Icy ftpy
at `
7
TOWN OF QUEENSBURY BUILDING DEPARTMENT
Based on our limited examination,
compliance with our comments shall
not be construed as indicating the
plans and spedCatiOns are in full
compliance with the Building Codes of
New York State.
c�U13
M �1
TN
BULL IN
p,a,Ae ,_' Y
Di6'
SILL SYSTEM
0- s i . vile ► late
m1,4" Sill Sealer Casket
-1 MCI A,— n 1,�.� c�,.la,. .�2n Long
/ - 11L U10 Ylnlrllot Bolts 1L
Existing Wall @ 6` olc, min 2 per plate and max.
1 T from corners
Floor Syste
cr%umnATivkl QVCTr-RA
u u
Crawl Space _ _ - 8" Concrete Block Wall
Vapor Barrier N 2 + - barging and waterproofing below grade
2" Rigid insulatio
(R-10) -
- a
a
FOOTING SYSTEM
- 16"x 8" Continuous Concrete Footing
t -`T n rn..... .0 A M
WI L KOWS " Bars
- 4" ADS perforated drain to approved source -
cover wig E&4/ �iortie and wrap with _Titer
fabric
FOUNDATION REPLACEMENT DETAIL,
NOT TO SCALE
D
4�3
Compliance Certificate
Project Title: Arakalian Residence
I LL �JC P Y
Report Date:08/01/08
Data filename:H:\Active ProjectslArakalian Camp Renovations\Misc\Arakalian Residence.rck
Energy Code: 2000 IECC
Location: Glens Falls,New York
Construction Type: Single Family
Glazing Area Percentage: 26%
Heating Degree Days: 7635
Construction Site: Owner/Agent: Designer/Contractor:
Queensbury,,NY Dave and Lois Arakalian Art Pakatar
9 Viewpoint Drive Stonehenge Associates
Troy,NY 121 Annie Street
Troy,NY 12180
283-3193
apakatal Cnycap.rr.com
Compliance:8.4ga Better Than Code Maximum UA:190 Your UA:174
Ceiling 1:Cathedral Ceiling(no attic) 500 420 0.0 13
Ceiling 2:Flat Ceiling or Scissor Truss 282 42.0 0.0 8
New 2x6 Wall:Wood Frame,16"o.c. 242 38.0 0.0 10
Window 1:Wood Frame:Double Pane with Low-E 24 0.350 8
New Zx4 Wall:Wood Frame,16"o.c. 165 24.5 0.0 7
Door 1:Glass 41 0.350 14
Existing Zx4 wall:Wood Frame,16'o.c. 510 24.5 0.0 18
Window 2:Wood Frame:Double Pane with Low-E 84 0.350 29
Door 2:Glass 93 0.350 33
Floor 1:All-Wood JoistlTruss:Qver Unconditioned Space 782 21.0 0.0 34
Furnace 1:Forced Hot Air90 AFUE
Air Conditioner 1:Electric Central Airl3 SEER
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2000 IECC requirements in
REScheck Version 4.1.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name-Title Signature Date
Project Notes:
Existing Crawl Space-uninsulated-all floors to be insulated
New furnace to be provided,ducts in unconditioned space to
be insulated and sealed per code
f
Project Title:Arakalian Residence Report date:08101108
Data filename:H:1Active Projects%Arakalian Camp Renovations\MiscVkakalian Residence.rck Page 1 of 4
Inspection Checklist
Date:08/01/08
Ceilings:
❑ Ceiling 1:Cathedral Ceiling(no attic),R-42.0 cavity insulation
Comments:
❑ Ceiling 2:Flat Ceiling or Scissor Truss,R-42.0 cavity insulation
Comments:
Above-Grade Walls:
❑ New 2x6 Wall:Wood Frame,16"o.c.,R-38.0 cavity insulation
Comments:
❑ New 2x4 Wall:Wood Frame,16"o.c.,R-24.5 cavity insulation
Comments:
❑ Existing 2x4 wall:Wood Frame,16"o.c.,R-24.5 cavity insulation
Comments:
Windows:
❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor.0.350
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ Window 2:Wood Frame:Double Pane with Low-E,U-factor.0.350
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Doors:
❑ Door 1:Glass,U-factor.0.350
Comments:
❑ Door 2:Glass,U-factor.0.350
Comments:
Floors:
❑ Floor 1:All-Wood Joistlfruss:Over Unconditioned Space,R-21.0 cavity insulation
Comments:
Heating and Coding Equipment:
❑ Furnace 1:Forced Hot Air.90 AFUE or higher
Make and Model Number.
Air Conditioner 1:Electric Central Air.13 SEER or higher
Make and Model Number.
Air Leakage:
❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed.
Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible
materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation.
Vapor Retarder.
Project Title:Arakalian Residence Report date:08101/08
Data filename:H:1Active ProjectslArakalian Camp RenovationslMiscVlrakalian Residence.rck Page 2 of 4
} Fi Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
Materials Identification:
Ll Materials and equipment are installed in accordance with the manufacturees installation instructions.
Lj Materials and equipment are identified so that compliance can be determined.
Li Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
Lj Insulation R-values,glazing U-factors,and heating equipment efficiency are clearly marked on the building plans or specifications.
Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner
that achieves the rated R-value without compressing the insulation.
Duct Insulation:
Ducts in unconditioned spaces are insulated to at least R-5.Duds outside the building are insulated to at least R-8.0.
Duct Construction:
Ll All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric,or
tapes.Tapes and mastics are rated UL 181A or UL 181B.
Exceptions:
Continuously welded and locking-type longitudinal joints and seams on duds operating at less than 2 in.w.g.(500 Pa).
rJ The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
Thermostats exist for each separate HVAC system.A manual or automatic means to partially restrict or shut off the gating and/or
cooling input to each zone or floor is provided.
Service Water Heating:
Li Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or
is part of a circulating system.
Lj Circulating hot water pipes are insulated to the levels in Table 1.
Circulating Hot Water Systems:
Lj Circulating hot water pipes are insulated to the levels in Table 1.
Swimming Pools:
All heated swimming pools have an ordoff heater switch and a cover unless over 20%of the heating energy is from non-depletable
sources.Pool pumps have a time clock.
Heating and Cooling Piping Insulation:
HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
Project Title.Arakalian Residence Report date:08101/08
Data filename:H.IActive ProjectslArakalian Camp RenovationsWiscXArakalian Residence rck Page 3 of 4
Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non-Circulating Runouts Circulating Mains and Runouts
Heated Water Up to 1" Up to 1.25" 1.5"to 2.0" Over 2"
Temperature("F)
170-180 0.5 1.0 1.5 2.0
140-169 0.5 0.5 1.0 1.5
100-139 0.5 0.5 0.5 1.0
Table 2:Minimum Insulation Thickness for HVAC Pipes
Fluid Temp.
Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range("F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(far feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0
Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD:(Building Department Use Only)
Project Title:Arakalian Residence Report date:08/01/08
Data filename:H:\Active Projects\Arakalian Camp Renovations\Misc\Arakalian Residence.rck Page 4 of 4