2008-464 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development- Building &Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number. P20080464 Date Issued: Tuesday, December 23, 2008
This is to certify that work requested to be done as shown by Permit Number P20080464
has been completed.
Location: 178 AVIATION Rd
Tax Map Number. 523400-295-018-0001-070-000-0000
Owner. ROBERT & JEANNIE MINER
Applicant: ROBERT & JEANNIE MINER
This structure may be occupied as a:
Residential Addition By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan, av
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
(2t 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20080464 Application Number. A20080464
Tax Map No: 523400-295-018-0001-070-000-0000
Permission is hereby granted to: ROBERT & JEANNIE MINER
For property located at: 178 AVIATION Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: ROBERT &JEANNIE MINER
178 AVIATION Rd Residential Addition $45,000.00
QUEENSBURY, NY 12804 Total value $45,000.00
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans &Specifications
2008-464
$75.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Thursday, September 17, 2009
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the( o Que 'busy; d� `NW nesday, September 17, 2008
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
.---------------------------------.._._.-/-�_- OFFICE USE ONLY ........-------.................� �..,................._.,�
TAX MAP NO. PERMIT NO. z1al
; ;
FEES: PERMIT175� RECREATION ENGINEERING
(If applicable) ;
PRINCIPAL STRUCTURE:
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO
REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION.
APPLICANT/BUILDER: 6"'"w^-e OWNER: L rry Lv�, n,.,
ADDRESS: --7`/ b 1Ny}{iry�G.v.� car► Q,«eJ'ADDRESS: 1-11- A-j1-j(3%,\ tZ
PHONE NOS. 3(, i-Uy 3cr PHONE NOS,
CONTACT PERSON FOR BUILDING &CODES COMPLIANCE:* PHONE: 3 61-ok 35
LOCATION OF PROPERTY: 12 8- Ay i alo h II;Z Gwe sns a vr y W� 12fG-j
SUBDIVISION NAME:
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT
APPLY TO YOUR z LL a C'1 w U. cn
LU
PROJECT O F- O � w Q a0.
U
w 0 u_ 0 z C� t- t^ 0 1- w w Z
z Q Q cn N cn 0 u- F- u_ a = *a
SINGLE FAMILY , f a a 3 �J-
TWO-FAMILY V
MULTI-FAMILY
(NO.of UNITS )
TOWNHOUSE
BUSINESS OFFICE
RETAIL-
MERCANTILE
FACTORY OR
INDUSTRIAL
ATTACHED
GARAGE(1,2,3)
OTHER
IF COMMERCIAL OR INDUSTRIAL- NAME OF BUSINESS:
ESTIMATED CONSTRUCTION COST: L1�i o`� FUEL TYPE:
HEAT TYPE: E)cc fir, �- "HOW MANY FIREPLACE(S): AND/ OR WOODSTOVES(S):
ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE?
IS THIS A HISTORIC SITE?
PROPOSED USE OF BUILDING OR ADDITION: 1'>e Z itoo r,, -5`y+1\1i f-,j ,
'Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office
B 3-LGL 1]-OS
QTown of Queensbury - Community Development Office - 742 Bay Road, Queensbury, NY 12804
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? '3h P� " �x { �'/
ARE THERE EASEMENTS ON PROPERTY?
I acknowledge no construction activities shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete statement/description of the work proposed, that all work will be performed in
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above.
Signed Ct.A -
Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction
codes or septic systems)
Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process,
application requirements or to schedule an appointment)
......................
Permission is hereby granted to the above ; This application / proposed action described 11
Applicant to erect or alter the building herein is found to be in accordance with the
01 described herein in accordance with said ; zoning Laws of the Town of Queensbury.
Application:
, ,
, 0
, , ,
, ,
,
0
, ,
BUILDING & CODES APPROVAL ZONING APPROVAL 11
, • ,
, ,
,
o DATE 0
DATE ;
:...................................................� :...._._....._..._._......_.____.._._.___.__........J
QUESTIONS? CALL 761-8256 OR EMAIL
codes(&.gueens bury.net
Office Use Only VISIT OUR WEBSITE FOR MORE INFORMATION
Operating Permit Issued: Yes No www.pueensburv.net
Occupancy Type:
Construction Classification:
Assembly Occupancy Limit:
Special Conditions:
fir;<c Town of Queensbuny - Community Development Office - 742 Bay Road, Queensbury, NY 12804
heck Residential Plan Review: One & Two Family Dwellings
/N/N/A
(2)Full sets of plans
Over 1,500 sq. ft.—Stamped
Design Loads On Plans: 90 Wind Floor Loads 40 psf
50 Ground Snow Load Sleeping Areas and Attics 30 psf
Calculations:
Window Schedule With Glass Size
Door Schedule/Main Entrance 36"Door
Emergency Escape Or Bedrooms and Habitable Space
Above/Below grade,5.7 sq. ft.
Grade,5.0 sq. ft.
24"(h)x 20"(w)min.
44"Max.Height above floor
Residential Check Paperwork Compliance and Inspectors Checklist: OK
inpproofing/Waterproofing Materials On Plans
Foundation Drainage On Plans, if required
6"Drop in 10' Exterior Grade
Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where
Required
Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls
Platforms At Exterior Doors
Stairway Headroom 6' 8' All Stairs 36"Width
Stair Run and Rise
Winder Run and Rise
Spiral Not Allowed From 2" Story
Smoke Detectors Battery Backup and Proper Location
Bathroom Fixtures Proper Clearance
Hall Width, 36"min.
Handrails More Than Four Risers On Open Sides
Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht.
Safety Glazing Notes For Required Areas
Garage Fire Separation
Garage Floor Sloped
Attic Access
Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access
Carbon Monoxide Detector Outside Lowest Sleeping Area, On Every Level&
Interconnected
Soil Test Results, if required
Septic To Well Or Water Line Separation
All Paperwork Signed
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518) 761-8256 Arrive: am/pm Depart2,)P—am/pm
Date Inspection request received: Inspector's Initials:
NAME: PERMIT#:
LOCATION: DATE:
TYPE OF STRUCTICURE
Comments:
Yes No NIA
4" Building Number Address visible from road
Chimney,Height/"B'Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs deckspatios more than 30 inches above grade �
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more t,
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access 1 sq.ft.-150 s .ft.vents
Bathroom Fans if no window
Plumbing fixtures
Foundation insulation/Insulation Certification
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency ress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnwell lot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum'A"Gypsum
Basement stairs dosed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical 01
Final Survey Plot Plan
Arc Fault Breaker in Bedrooms
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required `
Okay to issue C/C or C 10 Temporary/Permanent
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised
January 7,2008; Revised 6/26/08
'z-
.Queensbury Building & Code Enforcement - Residential Final Inspection `
Office No. (518)761-8256 Arrive: am/ ,/ D'epart: am/pm
Date Inspection request received: Z ) U� Inspector's Initials: � `�
NAME: to PERMIT#: _ (6,
LOCATION: Av t I- v CA,-, DATE:
TYPE OF STRUCTURE:
Comments:
Yes N/A
4" BuildingNumber Address visible from road
Chimney Height/"B'Vent/Dired Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Corroete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs decks,patios more than 30 irxdies above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 indmes to 38 inches
Deck Bras /Handicapped Ramp Compliant
Grade awav from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 indies above grade
Interior privacy/trim/doors/main entrance 36 indtes
Bathroom/Kitdien wate " ht
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 incim x 22 inches x 30 inches in accessible area
Crawl Spaces 18 inch x 24 inch access 1 sq.ft:150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation yr v(C' �<5 C,U, 9
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within fine of site
Oil Fumace shut-off at entrance to fumace area
Fumac&+W Water Heater operatiN
Low water shut-off boiler
Relief Va s installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrodk Underside minimum W Gypsum
Basement stairs dosed rise>4 indres
Garage Fh"Pitched
Garage fireproofing/%hour fire door/door closer
Dud work Sealed
Gas Logs in or G re
Final Electrical
Final Survey Plot Plan
Arc Fault Breaker in Bedrooms
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance reqtAred
Flood Plain Certification,if required
Okay to issue C/C or C 10 Temporary/Permanent
L:\Building&Codes Fortns\Building&Codesllnspection FormMRssidential Final Inspection Form_revised_100405.doc;Revised
January 7,2008
10 --12- ll�n �
Rough Plumbing / Insulation Inspe on Report
Office No. (518) 761-8256 Date Ins ectiog request received:
Queensbury Building & Code Enforcement Arrive: `iam/pmj am/pm
742 Bay Road, Queensbury, NY 12804 Ins is Initials:
NAME: 1 i ke PERMIT #:
LOCATION: INSPECT ON. t7
TYPE OF STRUCTURE:
Y N NIA
Rough Plumbing / Nail Plates
Plumbing Vent/Vents in Place
1 % inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain/Vent
Air/Head f �
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air1.-�eatl�
50 P.S.I fot,15 minutes
Insulation:/Residential Check/Commercial Check
T ..'Similar Exterior Sealant Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing Insulation Reporkrevised Nov 17 2003, revised February 15,2005, revised January 7,2008
Rough Plumbing / Insulation Inspectidh Report
Office No. (518) 761-8256 Date InSiDection request received:
Queensbury Building & Code Enforcement Arrive: �J am/prr; Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME.
±''� PERMIT#:
LOCATION: kz:�-j INSPECT ON: —
TYPE OF STRUCTURE:
Y N N/A
(I-K-tugh Plumbing / Nail Plates
Plumbing Vent/Vents in Place
um Drain Size
Washing Machine Drain 2 inch minimum
leanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
50 P.S.I for 15 minutes
Insulation/Residential Check/Commercial Check
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing Insulation Report.revised Nov 17 2003, re%ised February 15,2005, revised January 7,2008
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/P Apart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
n
NAME: 1'4ec- PERMIT
LOCATION: INSPECT ON: /- -
TYPE OF STRUCTURE:
I�
Y N I WA COMMENTS'
Framing CC , - s`-C J��41
Attic Access 22"x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jadc Posts/Main Beams
Exterior sheeting nailed properly
17 O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/W 16 gauge 8 16D roes each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separ n 1, 2, 3 hour
w�tl 2, 3, 4 h6wr 1
Firestopping
led
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. CM
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes Fonns-01-OftildiM&CodesNinspection FomtsTraming Fredoppft Irispedion RepoR6oc Revised January 7,2008
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection re est received:
1 .� . ��
Queensbury Building & Code Enforcement Arrive: f • � am/pm Lepart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
6
NAME: �JAkIti.,olJ PERMIT #: —
LOCATION: f 16 AV -,J /Q<:> INSPECT ON:
TYPE OF STRUCTURE:
Y IN N/A
Rou h Plumbin Nail Plates -G
Plumbing Vent Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cieanout every 100 feet I change of direction
Pressure Test
Drain / Vent
Air/ Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air / Head
50 P.S.I for 15 minutes
Insulation Residential Check Commercial Check
Proper Vent Attic Vent
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
COMMENTS:
LAPam Whiting\Buiiding&Codesunspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
-1'K'
Framing /Firestoppin Inspection Report
Office No. (518) 761-8256 Date' sectionpquest received:
Queensbury Building&Code Enforcement Arriv':: D i am/p Depart: am/pm
742 Bay Road, Queensbury,NY 12804 Inspect is Initials: .
NAME: PERMIT#:
LOCATION: iA Ti O INSPECT ON:
TYPE OF STRUCT
Y N N/A � COMMENT
Framing 1 -�, ,
Attic Access 22"x 30"minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
g g
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in.or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate i
I
1 `/2(w) 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
chor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1,2, 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side % inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
Foundation Inspection Report
Office No.(518)761-8256 Date Inspectio
q request received: hble 6
Queensbury Building&Code Enforcement Arrive: V am/PIIV Depart: t Amlpm
742 Bay Rd.,Queensbury,NY 12804 Inspector s Initials:
NAME: A�l
PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is resp Bible t or
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
1
l
REScheck Software Version 4.1.4
Compliance Certificate
Project Title: LARRY WAIMON
Report Date:08/21/08
Data filename:Untitled.rck
Energy Code: 2007 New York Energy Conservation
Construction Code
Location: Warren County,New York
Construction Type: Detached 1 or 2 Family
Heating Type: Non-Electric
Glazing Area Percentage: 10%
Heating Degree Days: 7635
Construction Site: Owner/Agent: Designer/Contractor:
178 AVIATION ROAD
QUEENSBURY,NY 12804
!compliance:
Compliance:31.2%Better Than Code Maximum UA:218 Your UA:150
Gross Cavity Cont. Glazing LIA
Assembly Area or R-Value R-Value or D..
Perimeter U-Factor
Ceiling 1:Flat Ceiling or Scissor Truss 656 38.0 0.0 20
Wall 1:Wood Frame,16"o.c. 970 21.0 0.0 47
Window 1:Wood Frame:Double Pane with Low-E 55 0.350 19
Door 1:Glass 44 0.350 15
Door 2:Solid 44 0.100 4
Basement Wall 1:Solid Concrete or Masonry 842 13.0 0.0 45
Wall height:7.9'
Depth below grade:7.9'
Insulation depth:7.9'
Furnace 1:Forced Hot Air 90 AFUE
Air Conditioner 1:Electric Central Air 13 SEER
The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted
with this permit application.The proposed systems have been designed to meet the 2007 New York Energy Conservation Construction
Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her
knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code.
GrH21 I4Es— TWLA TS t-IAI t - 6-Z1-68
Name-Title Signature Date
Project Title: LARRY WAIMON Report date:08/21/08
Data filename: Untitled.rck Page 1 of 4
REScheck Software Version 4.1.4
Inspection Checklist
Date:08/21/08
Ceilings:
❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation
Comments:
Above-Grade Walls:
❑ Wall 1:Wood Frame,16"o.c.,R-21.0 cavity insulation
Comments:
Basement Walls:
❑ Basement Wall 1:Solid Concrete or Masonry,7.9'ht/7.9'bg/7.9'insul,R-13.0 cavity insulation
Comments:
Windows:
❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.350
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Doors:
❑ Door 1:Glass,U-factor:0.350
Comments:
❑ Door 2:Solid,U-factor:0.100
Comments:
Heating and Cooling Equipment:
❑ Furnace 1:Forced Hot Air:90 AFUE or higher
Make and Model Number.
❑ Air Conditioner 1:Electric Central Air:13 SEER or higher
Make and Model Number:
Air Leakage:
❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed.
❑ Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible
materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation.
Vapor Retarder:
❑ Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
Materials Identification:
❑ Materials and equipment are installed in accordance with the mainufacturer's installation instructions.
❑ Materials and equipment are identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
❑ Insulation R-values,glazing U-factors,and heating equipment efficiency are clearly marked on the building plans or specifications.
❑ Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner
that achieves the rated R-value without compressing the insulation.
Duct Insulation:
❑ Supply ducts in unconditioned attics or outside the building are insulated to at least R-11.
Project Title: LARRY WAIMON Report date:08/21/08
Data filename: Untitled.rck Page 2 of 4
Return ducts in unconditioned attics or outside the building are insulated to at least R-6.
❑ Supply ducts in unconditioned spaces are insulated to at least R-11.
❑ Return ducts in unconditioned spaces(except basements)are:insulated to R-2.Insulation is not required on return ducts in basements.
Duct Construction:
Lj All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric,or
tapes.Tapes and mastics are rated UL 181A or UL 181B.
Exceptions:
Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa).
Lj The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
Lj Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone.
Electric Systems:
Separate electric meters exist for each dwelling unit.
Fireplaces:
Lj Fireplaces are installed with tight fitting non-combustible fireplace doors.
Lj Fireplaces have a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York
State,the Residential Code of New York State or the New York City Building Code,as applicable.
Service Water Heating:
Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or
is part of a circulating system.
❑ Circulating hot water pipes are insulated to the levels in Table 1.
Circulating Hot Water Systems:
Lj Circulating hot water pipes are insulated to the levels in Table 1.
Swimming Pools:
❑ All heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depletable
sources.Pool pumps have a time clock.
Heating and Cooling Piping Insulation:
Ll HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
Project Title: LARRY WAIMON Report date:08/21/08
Data filename: Untitled.rck Page 3 of 4
Fable 1:Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non-Circulating Runouts Circulating Mains and Runouts
Heated Water Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-169 0.5 0.5 1.0 1.5
100-139 0.5 0.5 0.5 1.0
Table 2:Minimum Insulation Thickness for HVAC Pipes
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range(°F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0
Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD:(Building Department Use Only)
Project Title:LARRY WAIMON Report date:08/21/08
Data filename: Untitled.rck Page 4 of 4