blower door results Vestal Office Wappingers Falls Office Main Office 414 Commerce Road 95 Airport Drive – Suite 1 868 Burdeck Street P.O Box 66 Wappingers Falls, NY 12590 Schenectady, NY 12306 Vestal, NY 13851 Tel. (845) 452-5400 Tel. (518) 355-0433 Tel. (607) 729-5847 Fax. (845) 452-1606 Fax. (518) 355-3174 Fax. (607) 797-7520 www.appoloheating.com Property Address 59 Richmond Hills Dr, Queensbury Ny Builder Hodorowski Date of test 2/12/20 Model of Home Ceiling Level Square Feet Height Air Volume (Cu. Ft.) Basement 935 8 7480 1 st Floor 714 9 6426 2nd Floor 927 8 7416 Family Room 221 17 3757 Total 2797 25079 Blower Door Test TEC Minneapolis Blower Door with TEC DG-1000 Equipment Used Manometer Fan Configuration A Ring Measured CFM50 1242 Calculated ACH50 3.0 Testing done in accordance with ASTM E 1827-11 I hereby certify and attest to the accuracy of the testing results Test performed by: Nick Abrunza Energy Auditor/ BPI Certification Number: 5059019 APPOLOHEAT1 Degrees Above The Rest,S/WCEaCertificateofCompletionP.c-0494-ZO Duct Sealing Performed For:200 Hodorowski,Appolo Heating 59 Richmond Hills Dr Queensbury,NY 12804 250 =200 \ Overall Sealing Results ie \When we arrived,z 0 Y YOUR DUCTS HAD:Z \281.3 CFM of Leakage,equivalent to a ion Ni 53.1 Square Inch Hole NO This equals 168.8 refrigerators full of air loss every 50 —hour.MN After we finished,0. YOUR DUCTS HAVE:cn aw Oo DO Re 28.2 CFM of Leakage,equivalent to a ‘Sealing Time in Minutes 5.3 Square Inch Hole This corresponds to a 90.0%Reduction in Duct Leakage. Aeroseal Technician Nick Aeroseal Case ID 5068 Date of Seal 1/30/2020 System Description Upflow Basement Note:Duct Leakage results are calculated in SE ae em Cubic Feet per Minute (CFM)measured at a Seal Description Basement Return standard OPERATING PRESSURE of 25 Pa.(ey Dor AEROSEAL.Duc Seating Performed By: rearDuctSeatingFromThe.Appolo Heating,Inc “4 868 Burdeck St | ‘Schenectady,NY 12306 | Phone:(518)355-0433 (|FEB 13 20 ~APPOLOHEAT1 Degrees Above The Rest,aaie Certificate of Completion .._,eerie aaDuctSealingPerformedFor: Hodorowski,Appolo Heating 59 Richmond Hills Dr Queensbury,NY 12804 Overall Sealing Results When we arrived, YOUR DUCTS HAD: 291.8 CFM of Leakage,equivalent to a 55.1 Square Inch Hole This equals 175.1 refrigerators full of air loss every ‘hour. After we finished, YOUR DUCTS HAVE: 33.1 CFM of Leakage,equivalent to a 6.3 Square Inch Hole This corresponds to a 88.7%Reduction in Duct Leakage. Note:Duct Leakage results are calculated in Cubic Feet per Minute (CFM)measured at astandardOPERATINGPRESSUREof25Pa. 300. wl \7Fw N 2||) S 100.aL 0. 0 0 20 3 4 50 6 ‘Sealing Time in Minutes. 7 AEROSEAL.Duct Sealing From The Inside ‘Aeroseal Technician Nick ‘Aeroseal Case ID 5068 Date of Seal 1/30/2020 System Description Upfow Basement Seal Description Basement supply Hardware HomeSeal Connect Duct Sealing Performed By: ‘Appolo Heating,nc. £868 Burdeck St Schenectady,NY 12306 | Phone:(518)355-0433,|