Loading...
architect's commentsRUCINSKI R Ronald Richard Rucinski Ethan Peter Hall 134 Dix Avenue Glens Falls NY 12801 Voice Fax Email TECTURE 518 741-0268 518 741-0274 ‘ephali@nycap.rr.com Transmittal To: From: Date: Re: John, John O'Brien -Town of Queensbury —Code Enforcement FEB 12 2020 Ethan Hall 12 February,2020 Dr.Lewis -365 Aviation Road -Response to review comments In response to your review comments we offer the following; Counter detail is attached,it was omitted from the original submission in error. Page A3.0 was submitted as a reference drawing from the dental equipment provider,the rooms referred to on those particular plans are not part of this project.The floor plans provided by this office are the rooms being created.Please disregard the rooms shown on drawing A3.0 of the reference drawings. There will be minor lighting modifications,mainly relocation of existing fixtures due to partition re-arrangements,otherwise all fixtures are existing.There will be some minor HVAC modifications,again mainly relocation of existing ductwork to accommodate new partition locations,otherwise there will be no changes to the HVAC system. Fire Marshal review comments ~responses are as follows; ‘Knox box is existing and is located at the top of the ramp at the main entry to the building. CO detection to be confirmed,|believe it is existing. There is a fire extinguisher in the basement level of the building. Function test to be performed prior to CO. Locks and latches do comply and were installed as part of the previous project at this location. ©[believe truss ID placards exist on the main entry door and at the electric service entry.If they do not exist they will be installed as part of this project. '*There will be a total of five (5)medical gas bottles stored in the gas storage closet indicated on the plans.The medical gas closet will contain two (2)tanks of Nitrous ‘Oxide (N20)size G tanks and three (3)tanks of Oxygen (02)size H tanks.See attached photograph.The contractor will be plumbing the three operatories to use the medical gas for dental procedures and the installation will be verified by a third party medical gas verifier. ‘Y.ALewis -Dental Office -Dr Shin Aviation Road\Paperwork\Transmittal -12 Feb 2920.d0c 4 a |believe this covers all the open items in your review letter,if there are any additional items please let me know. Regards, Ethan P.Hall Architect ‘YA\Lewis -Dental Office -Dr Shin Aviation Road\Peperwork\Transmitial -12 Feb 2020.doc 2 3-10"|—DBL.2x10 HEADER a 2'-10" +——2 LAYERS OF 3/4”PARTICLE BOARD WITH PLASTIC LAMINATE TOP AND EDGE.|3/4"PARTICLE BOARD DESK TOP WITH PLASTIC LAMINATE TOP &EDGE Ym LEDGER BRACE (TYP.)(SHOWN BEHIND) 2-6"2-0" sd/ng S100 PARTHON AT 18"06 WITH 5/8”GYP.BD.ON EACH SIDE WOOD BASE MOLDING FINISHED FLOOR 2" RECEE TION WINDOW SECTION 7