Loading...
2008-521 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20080521 Date Issued: Tuesday, January 12, 2010 This is to certify that work requested to be done as shown by Permit Number P20080521 has been completed. Location: 474 AVIATION Rd Tax Map Number. 523400-302-005-0001-098-000-0000 Owner. JOLLEY ASSOCIATES, A VERMONT GENERAL ] Applicant: JOLLEY ASSOCIATES, A VERMONT GENERAL PARTNF This structure may be occupied as a: Commercial Addition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20080521 Application Number. A20080521 Tax Map No: 523400-302-005-0001-098-000-0000 Permission is hereby granted to: JOLLEY ASSOCIATES, A VERMONT GENERAL P For property located at: 474 AVIATION Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: JOLLEY ASSOCIATES, A VERMOT Commercial Addition $65,000.00 PO BOX 671 Total Value $65,000.00 ST. ALBANS, VT 05478-0000 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2008-521 new fuel canopy $100.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Tuesday, October 06, 2009 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the�7 f Quee urn; ,r A da , October 06, 2008 ff SIGNED BY :�i� V F for the Town of Queensbury. Director of Building&Code Enforcement .s-- _ _ - FICE USE ONLY ' TAX MAP NO.` / �' PERMIT NO. ! ' FEES: PERMIT /W RECREATION ENGINEERING (If applicable) o ' ............................................................. . PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: ✓may%°*TQociw, >'.5'e.-vrr fLl- OWNER: a��.G'oGCi/IS zi✓C /6 we RD• SO( 62'/, sy flower w«,-4- sf ADDRESS: Sclimec7-4 do f IVV,, 1.?30y ADDRESS: S'T w4Bj _f Yj' 05,3117B PHONE NOS.s/8-39y-67SS�3 Y-/S99 PHONE NOS. 9002 - CONTACT PERSON FOR BUILDING&CODES COMPLIANCE:we_ PHONE: 39,4- LOCATION OF PROPERTY: '! Jy Av:gTi oa Rc% SUBDIVISION NAME: kj-ror;*1w'S PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT Z APPLY TO YOUR 0 Cr d Oj w U. PROJECT LD DO� OJ I _j o 2= Z ' Q Q �(n N(n OLL OLL a.mca SINGLE FAMILY TWO-FAMILY i MULTI-FAMILY(NO.� TOWNHOUSE BUSINESS OFFICE j RETAIL- MERCANTILE FACTORY OR I INDUSTRIAL ATTACHED GARAGE(1,2,3) 13 Ole OTHER Town of Queenshury • Community Development Office • 742 Bail Road, Queens6urij, NY 12804 t IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS: 7'oGCE� �t�ec;yrli:t /�7o6•Z G ESTIMATED CONSTRUCTION COST: FUEL TYPE: HEAT TYPE? AloNe_ *HOW MANY FIREPLACE(S). " AND/OR WOODSTOVES(S): w0� ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? Nd IS THIS A HISTORIC SITE? / o PROPOSED USE OF BUILDING OR ADDITION: 2ETft-r- 6ai gv�qe ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? A10 ARE THERE EASEMENTS ON PROPERTY? wU *Please complete a separate Application for `Fuel Burning Appliances&Chimneys"available in our office I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed,that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have rea a to the above. Signed �.� , /"/" •�-y- Director of Building & Codes: 761-8256 (for questions QUESTIONS? CALL 761-8266 OR EMAIL regarding Building Permits, construction codes or septic codes(ftueensbury.net systems) VISIT OUR wESSITE FOR MORE INFORMATION Zoninq Administrator: 761-8218 (for questions regarding www.gueensbury.net required permits, the permit process, application requirements or to schedule an appointment) This application/proposed action described Permission is hereby granted to the above herein is found to be in accordance with the Applicant to erect or alter the building described ; zoning Laws of the Town of Queensbury. herein in accordance with said Application: 00 1 I ZONING APPROVAL DATE o BUILDIN ODES APPROVAL E i 0 Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 ------------I---------------------- PROJECT NAME: OFFICE USE ONLY 17 y STAFF INITIALS: BUILDING PERMIT SUBMISSION DATE: CHECKLIST FOR: :.____ MULTIPLE DWELLING or COMMERCIAL PROJECTS 1. Building Permit Application Completed? YES NO N /A Energy Form or CheckMate Energy Code Compliance 2. Forms Complete? (2-copies) 3 Energy Code Inspector's Report from Checkmate Program? (2-copies) Septic application completely filled out? 4' (if applicable) l (� 5. Electrical Inspection Form complete? )I�5 j6. Two (2) sets of the plans each of the following: YES NO ! N /A a. Floor plans (s)? N�P ' 'E I b. Foundation plan?E 1 c. Cross sections (s)? ✓f/� d. Elevations? - -- - - -. e. Design loads including floor, snow load, and wind �as load? i I f. Seismic design (required after January 2003)? g. Plans signed and sealed by registered architect or �S engineer? I h. Window and door schedule? ( ( e✓�/1 Two (2) site plans showing location of the structure to be 7 built, location of well or water lines, location of septic system or sewer line with all setbacks and separation distances shown, and all improvements to the property 8. Solid Fuel Burning or Gas Appliance Form (if applicable)? 1 9. 1 Driveway Permit f i IN Town of Queensbury - Community Development Office • 742 Bay Rona, Queensbmry, NY 12804 r---10 ve-O(W6- Foundation Inspection Report Office No.(518)761-8256 Date In n®request received: Queensbury Building&Code Enforcement Arrive- am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspect is tials: NAME: o PERMIT#: LOCATION: INSPECT ON. TYPE OF STRUCTURE: Comments Y N N/A Footings Monolithic Slab Reinforcement in Place The contractor is resp ilible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM n US C ��� I Commercial Final Inspection Report Office No.: (518) 761-8256 Date Ins ection r es a ed- Queensbury Building&Code Enforcement Arrive: o Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Iniha s: NAME: PERM #: LOCATION: (�Z/ [✓ ^ .o�, DAT — —J(') COMMENTS: Y N NA Chimney/"B"Vent/Direct Vent Location L Xp 6 l Plumbing Vent Through Roof 6"/Roof Complete / 1 Exterior Finish/Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in. /Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 s . ft. All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36 w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator 18" Above Grade Floor Bathroom Watertight/Other Floors Oka Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System — Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 %2 doors > 10%> 1000 s . ft. 3/4 Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping,3,000 s . ft. Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Si a e/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Si na e Public Toilet Room Handicapped Accessible Handicapped Service Counters,34 in.,Checkout 36" Handicapped Ramp/Handrails Continuous/12 in.Beyond [Both sides] Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Sides by 20' /Driveable Surface 20'wide Okay To Issue Temp. or Permanent C/O �' vE Cz Okay To Issue C/C L:\Building&Codes Forms\Building&Codes\Inspection Forms\Commercial Final Inspection Report.doc Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection req ved: Queensbury Building&Code Enforcement Arrive: a rt: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials• NAME: PERMIT#: 7�I LOCATION: q-1Li AJ\ART C5c5 V'g-'ffl(7 INSPECT ON: \7 1Q-Qb TYPE OF STRUCTURE: C h P�MP r A i�� Y N N/A COMMENTS: Framing Attic Access 22" x 30" minimum Jack Studs/Headers Bracing/Bridging C�fvb v�v Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Botts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. CM 5.7 sf above/below grade 5.0 sf grade LABuilding&Codes Forms-01-MBuilding&Codeslinspection FomslFraming Firestopping Inspection ReporLdoc Revised January 7,2008 a � DENTS ENGINEERING, P.C. ❑ 594 Broadway Watervliet, New York 12189 Phone: 518-266-0310 Fax: 518-266-9238 ❑ P.O. Box 482 Orchard Park, New York 14127 Phone: 716-649-9474 Fax: 716-648-3521 SITE OBSERVATION REPORT PROJECT: Exit 19 REPORT NO: F-08-187-11-29-08 CLIENT: Jolley Associates DATE: 11-29-08 CONTRACTOR: EMCO JOB NO. FDE-08-187 A representative of Dente Engineering was present at the above referenced project to perform special inspection of the structural portion of the new canopy over the gas pumps. The structural steel and sheet metal framing portions of the canopy have been installed in general conformance with the installation drawings. All structural members are in place. All fasteners appear to be in place and the joints appear to be tight. The cold-formed structural pieces, for the canopy, are installed and were observed to be in general conformance with the installation drawings and all fasteners appear to be in place and tight. The electrical devices, fire protection piping, and signage appeared to not be completely installed and are not part of this inspection. Inspection of the column anchorage was covered in an earlier report. The canopy has been installed in general accordance with the project documents and is acceptable. BY: L.C. Ludwig-QISI LAWRENCE R. PILON, PE i �j STRUCTURAL STEEL CALCULATIONS FOR SB COLLINS 30' X 88' (6)COLUMN FUEL ISLAND CANOPY QUEENSBURY,NY Austin Mohawk Dwg# 08-130 DESIGN LOADS: Roof Live Load: 60 psf Flat Roof Snow Load: 60 psf Ground Snow Load: 60 psf Design Wind Loads 90 mph, Exposure "B"—(3) Second Gust Wind Speed per ASCE 7-02 Lateral on Fascia: 25 psf Uplift on Deck: 20 psf Assumed Allow. Soil Brg.: 2500 psf Calculations By: Lawrence R. Pilon,PE 51 Mapleview Drive p� NEW Pennellville,NY 13132 1�. r0 License # 073336 t , 30tx O�fOSUPI Y�tJ --------------- lOo 51jec" MAP. pCi 0l 'A 310 p5r s�d,,,o SAD CAXU a WV5 FOB s, ow WW-�) W'C& ('11L1JYCff� ���� e7 x C. ,( C c x P, t ExP 13 E,rAr, /*,#a 16 aX 3. 1 7x/�« ,6�3 z ` p5r C �tC1 �� ' 1 v �SF�71v�►r 6. S. � � r'-�GUI2E !- �� + Zx Wf,�YOO 7- I�X ANCF '7-07- (�MC7- T ( -3) b o 1 • ,�ozs� r�, 6i�C�frsf�w�Z��.v� S 13, 1s j)C5J6u scut uPG-r�l C,E' 0,7Axe"L s' UP GbAJo� 11S fac, xr - 13� 1 X,3'Se Is� ��cr� r y ClfpavS�JS G S s .rAjc,nLTa) f1tev&c.uw -cot) Ar SS 0• z,y C,"r<SG /,/,/S-C/-)) JTE CLA 5� J7 1S5Z1 � a jt6a, `v y o 3t= 6 -Z(3 a �6�Psr O, 2 5,r)aJ 7 U)Cl)U ' PUILLSOL)--4 (FEAM5 5uPPMUp-rA DEC4) pa DE5164D As WWW � ==N 5uPpbl?l6b 3� rn lfnl Gfr2D�2s CcQQss���G1Ms� e►z�ss�3E s ^N zl N N N N N N o �u�ecr� rl � 1 1 LOAD s L416"J- 754U* 9 L UUU4 )4 (LTB) cx_GcrXS C )JICAf 771E C�&/�j2�Ssyp,J (TO yZ ZE 571J SphA)S �69C� u �IA),O C,441,565 13419AY rb 7"c,JJ5T A00" rit" off-►2-4- 0YtACW4 -rs kf�QI-b Cat taut, WeJ' �Iv L .l -- -UJ5��4 cc) Cr G' � SPAN-CANT PURLINS(L-180) CUSTOMER.SB Collins DATE'09/16/08 LOCATION Queensbury,NY CALC BY Irp Al SIZE.3Ox88 DWG# 08-130 �J INNER SUPRT OUTER SUPRT PURLIN CANT SPAN LIVE DECK .FASCIA EFF... SELECT BM YIELD DEAD LIVE .:MOM :MOM ALLOW REa'D boc REQ'D b& REQ'D bN :REa'D' i.REa'D 1.SEAM 'BEAM -BEAM c BEAM' DEAD LIVE DEAD LIVE (a) (L) LOAD LOAD WT WIDTH BEAM WT STIR LOAD LOAD @SUPP IN SPAN`END DEFL (CANT), (SPAN) (SPAN) Sxx Sxx Sxx Sxxe '.Ixx OK???. RXN RXN RXN RXN (SPAN) :(CANT) (EFFECT) PS PSF PLF PLF) (KSI) (PLF) (PLF) (K- K- IN IN"4 IN*`4 I ""4 (IN)**3 (IN)-3 IN"3 (IN),-3 IN"4 KIPS KIPS KIPS KIPS 1 17 27 60 5 15 6 W16x40 40 50 85 360 64.3 6.9 1.00 493 5 45 28 25.7 64.7 54,8 518.0 YES 0.7 3.9 3.1 13.0 2 17 27 60 5 5 6.25 W16x40 40 50 76.25 375 ` 65.2 8.8 1.00 500 5 47 2.7 26.1` 64.7 54.8 518,0 YES 0.7 4.1 2.8 13.5 3 0 0 50 0 0 0.0 #DN/O! #DIVIOI #DIV/OI. #DIV/Ol #DIV/01 #DIV/01 00 0.0 0.0 0.0 '#DIVIOI #DIV/01 #DIV/01 #DIVIOI #f#t## 4 W12x14 14 50 14 0 0.0 #DIVIOI #DIV/01 #DIV/DI #DIVIOI #DIV/01' #DIV/01 OA 14.9 10.8 88.6 #DIV/01 #DIV/01 #DIV/01 #DIV701 ##### 5 W12x14 14 % 14 0 0.0. #DIVIO! #DIVIOI #DIV/01 #DfV/Of. #OIVIDI: #DIV/01 0'0 14,9 10.8 88,6 #DIV/01 #DIV/01 #DIVIOI #DIV/OI #ltt##1 6 0 0 50 0 0 0.0 #DIVIOI #DIV/01 #DIV/01. #DIV/01 #DIVM! #DIV/01 0.0 0'0 0.0 0.0 #DIV/01 #DIV/01 #DIV/O! #DIV/01 ##### 7 W12x14 14 50 14 0 0.0 #DIV/01 #DIV/01 #113 1 #DIVIOI ':#DIVIOI #DIV/01 0.0 14.9 10.8 88.6 #DIVIOI #DIV/01 #DIVIOI #DIV/01 ##### 8 W12x14 14 50 14 0 0.0 ODIVIOI #DIV/0! #DIV/O! #DN/0I #DIV/01 #DIVIOI 0.0 14.9 10.8 88.6 #DIV/01 #DIV/01 #DIV/01 #DIV/01 ##### 9 0 0 50 0 0 0.0 #DIVIOI #DIV/01 #DIV/01 #DIV/01 #DIV/Of #DIV/01 0.0 0.0 0,0 0.0 #DIV/01 #DIV/01 #DIV/01 #DIV/01 tfltk## 10 0 0 50 0 0 0.0 #DIVIOI #DIV/01 #DIVIOI. #DIV/01 #DIVIOI #DIVIOI 0.0 0.0 1 0.0 0.0 1 #DIV/01 #DIV/01 #DIV/01 #DIV/01 1##k## 36 OR 112 LIVE DEFL< (NOT APPL FULL LIVE 1/2 LIVE i FOR FOR EFFECT IF NO 112 LIVE INPUT VALUES FOR SEVEN COLUMNS(B-H)ABOVE 50 KSI LOAD ON a(12)/l80 IF a/I 4 0.2) LOAD ON LOAD ON MOM IN ,MOM AT Sxx SELECT ON ASTM CANTS& OR 1" 'FULL =,CANT, CANT, SPAN "SUPPT W/BOLT NEW CANT A36 OR (LESSER LIVE LOAD CTR CTR Sxx=` Sx)c= HOLES BEAM A572 VALUE) ON SPAN DEFL 4 'DEFL< M/.6Py 'MI.6Fy REMOVED BASED GR.50 NA IF L(12)/180 L(12)/180 FROM ON NOTES: : a/I 0.2 OR 1.75" OR 1.751, FLANGE Sxx or IV 1) USE ONLY FOR PURLINSHUNG FROM CROSS BEAMS (LESSER (LESSER AREA.(AT (UNBRACED L=O;COMPACT SECTION) VALUE) VALUE) SUPPORT ONLY)' 2) BRACE ENDS OF CANTILEVERS WITH''a'>12' USE ONLY W ITM 3) BRACE SPANS WITH L'>24 MOM AT I SUPPORT t � i i V 7 Irk 1I{l CPTPDup. Uv(-'Ai f�5 � I 04)-5Ser-Av,5 AM 5UPP0ML) OBI TZ�b OF Coe,61m A,S IaIPJ�O r=z u o c cotows r N r N� r r r r r r N N N cmN N Q J ` l.�JtD � cvcvr��.s C Cb' _ C b C (5-IP-C Y7W 6&TVoW ArsZ5 YtXH 1YEU4,LT4 GE 7 �SEI1..f�5� l`t`tC t.� Fo,, PO.Tl i j rrw6C OARS 3 .o Foy. deA#tS LOXgCDe aA)J,&�ios �3 0 7 Fly OFAV ('"0ICD TOP P-L$A4c xssieol c C4 ' l r �111SG 1p CaO P-CD a C� b 4 r COS&Xr-5e 4A00,'5 oA Y4 uVc6s-� ahADV1 Ilk r►S c�r�c. • �. X- G�J)OkrsE5 O,-2CA - Gr�c, rr1✓� CL►,*'fib E4� �i- f.`R dt; C- ►�,`E'�` k� 9 Zv F 00 777 W W N N " ( b OL� �✓ ; t C��t Icy 11gtf lC i'1 Y c'C,41FXk V;y L Lk 7►T = rf " ������ Jz Eitc�T 1yU Ls �. L A iota ►�Ln�� Lun�3 ; D�Ott , f � Yvl� UZ P2 �LZ 447, E 18x18 B,SEPLATE i� �rJ ��.� 'q3 Sal 5 CUSTOMER:SS Collins DATE:09/16/08 LOCATION:Queensbury,NY CALC BY:Irp SIZE:30x88 DWG#:08-130 w "jjWL+�I ✓ ^" /� r + � Mb PLATE LOADS AT COLUMN BASE Col Col Col ` Plate Plate Bolt Boft Anchor #Bolts (W or.7E) (W or.7E) (W or.7E) depth width Flange Len Width Pattern Pattern Bon ' on width BASEPLATE Pdead Mdead Plive Mlive "at Mlat Pup/down "d" ,tip "r 'W "B" "Ln" "Lb" Diam "Er (KIPS) - (KIPS) K PS (K•F KIPS IN N) I N) I N) (up*nog) AB'S 1 9.00 2.00 33.00 5.00 1.80 20,00 0.00 10.00 10,00 0.25 18.00 18.00 14.00 14.00 1.25 2 2 9.00 2.00 33,00 5.00 1.80 20.00 16.00 10.00 10.00 0.25 1&00 18.00 14.00 14.00 1.25` 2 3 10.00 10.00 0.25 18.00 18,00 14.00 14.00 1.25 2 O t0a O 4 10.00 10.00 0.25 18,00 18.00 14.00 14.00 1.25 2 Only if O O INPUT VALUES FOR SIXTEEN COLUMNS(B"Q)'ABO applic (IF ZERO VALUE,ENTER'O'OR CLEAR CELL) I , E PLATE PLATE BENDINGRESULTS REQUIRED_ WE0,6, E MAXANCH R:,TLO _LOAD CASE 1 LOAD CASE;2 LOAD CA E 3 LOAD O 4`. EQ D LC1 LC2 LC3 LC4 EQ'D Max Brg I Req'cl T Max Brg Req'd'4 Max Brg Req'd T Max Brg Req'd'f "t" WELD LOAD SF< LOAD SF`- LOAD SF LOAD SF KSI N (KSI) IN (KSI) IN KSI N N IN IN KIPS IPS KIPS KIPS 1 0.468 0.912 0,367 0.807 0.247 0.704 0.253 0,071 0,912 0.117 0.179 0.226 0.153 5/16 5.08 4.61 3.56 6.59 9.27 2.53 9.60 2.44 2 0.468 0.912 0,303 0.734 0.163 0.571 0.169 0.547 0.913 0.117 0.179 0.226 0,153 5/16"' 5.08 4.61 6.02 3.89 12.55 1.87 12.89 1.82 ' 3 #DIViO! #DfV/01 #DN/01 #DIV/01 #DIViO! #DIV/O! #DfV/01 #DIV/O! #DIV/Ol 0.000 0.000 0.000 0.000 5116 #DIV/01 #DIV/01 #DIV/O! #DIVIOf #DIV/0! #DIVf01' #DIV10! #DIWOI 4 #DIV/O! #DIV/01 #DIV/0! #DIV/O! #DIV/O! #DN/0! #DIV/01 #DIV/01 #DIV/O! 0.000 0,000 0,000 0.000 5/16 ' #DrV/01 #DIV/01 #DrV/O! #01001 #DIV/01 #DIV/01 #DIV/01 #DN/0I CHECK CHECK CHECK CHECK' MAX OF" MAX OF IF,<1 11 IF<1.1 IF<1.1 IF< .1 LESS LESS LESS LESS ` 4 CASES 4 CASES PICK PICK PICK PICK THAN THAN THAN THAN 3/4`' silo, NEW` NEW NEW NEW 1 KSI I I 1 KSI I I 1 KSI 1 KSI ` MIN MIN DIAM DIAM' DIAM DIAM MAX BEARING STRESS ON CONCRETE IS ASSUMED TO BE.35'3 KSI=1.05 KSI FOR 3000 PSI CONCRETE CHECK IF STIFFENERS REQ'D DUE TO ANCHOR BOLT TENSILE LOADS(SEE NOTE 6) NOTES: 1) THE FOUR LOAD CASES ARE LC7)DEAD+LIVE;LC2)DEAD+,75(WIND or,!SEISMIC)+0.75LIVE LC3)DEAD+WIND(or,!SEISMIC):AND 1.04),6DEAD+WIND(or.!SEISMIC) REQ'D t={(6'Tbolt'L)/(,75'Fy'be))"O.5(MIN`r FOR NO GUSSETS) PLATE 2) VALID ONLY FOR RECTANGULAR OR SQUARE HSS COLUMNS(ASTM A500)WITH 1 REQ D t- 1,10 IF REQ t>gCTUAI USE GUSSET ASTM A38 BASE PLATE AND ASTM A36(OR A307)ANCHOR BOLTS 2 REQ D t= 1.27 IF REQ t>ACTUAL USE GUSSET 4 (FOR ROUND COLUMNS CAN ASSUME d-,75"DIAMETER) 3 REQ D If- #DIV/O! IF REQ t>ACTUAL USE GUSSET 4 REQ'D I #DfV/O! IF REQ t>ACTUAL USE GUSSET 3) WELD ELECTRODES ASSUMED TO BE E70XX WELDING ROD L=dirt from bolt of to comer of column 4) MINIMUM SAFETY FACTOR(SF)FOR ANCHOR BOLTS IS 1.0 be ow effective weld strain width=2'1.(max=5"allowed) Fy=36 ksi 5) NO ALLOWABLE STRESS INCREASE OF 1.331S USED FOR CASES WITH WIND OR SEISMIC LOAD 6) CHECK BASEPLATE FOR BENDING 0 COLUMN CORNER DUE TO BOLT TENSION LOADS PER HS6 CONNECTIONS MANUAL PG 7-9 AND 7-10 (GUIDE FOR 1 Ox1 O,OR 12x12 COLS ON 3/4 PLATE-USE GUSSETS IF Tliok>SKIPS) (GUIDE FOR IOX10 OR 12x12 COLS ON 1"PLATE`•USE GUSSETS IF Tbolt>10 KIPS) �- CONSTRAINED FOOTERS-SQUARE CUSTOMER; SB Collin DATE: 09/16/08 LOCATION: Queensbury,NY CALC BY: Irp SIZE: 30x88 DWG#: 08-130 FOOTER LOADS AT COLUMN BASE COLUMN SOIL PROPERTIES PRELIM FTR SIZE/WEIGHT ISLAND WEIGHT. MISC TOTAL (W or.7E) (W or.7E) (W or:7 ) HEIGHT BEARING LATERAL SIDE DEPTH I WT WIDTH DEPTH WT WT DEAD Pdead Mdead Plive Miive Vlet Mvlat) Pup/down STR SRNG STR LENGTH WT (KIPS) (K-FT) (KIPS) (K-FT) (KIPS) (K-FT) (KIPS (FT) KSF), KSF/FT) (FT) „_(FT) KIPS) (FT) (FT) (KIPS) (KIPS) (KIPS) (up=ne9) 1 9.00 2.00 33.00 5,00 1.80 20.00 0.00 20.00 2.50 0.25 4.5 5 14.68 3 1 1.96 25.64 2 9.00 2.00 33.00 5.00 1.80 20.00 -16.00 20.00 2.50 0.25 4.5 5 14.68 3 1 1,96 25.64 3 18.00 2.50 0.25 5 5 18.13 3 1 2.18 20.30 4 18.00 Z.50 0.25 5 5 18.13 3 1 2.18 20,30 INPUT VALUES FOR SEVENTEEN COLUMNS(B-R)ABOVE Square Conc Canopy (IF ZERO VALUE,ENTER'0'OR CLEAR CELL) footings VA footer only 145 pcf Island mist FOOTER BEARING RESU TS OADT K,;; DOTER LOAD CASE 1 ;LOAD CASE 2 LOAD CASE 3 LO;ta CASE 4s B RING LOADS UPLIFT CHECK(LC 4) REQ'D CHOSEN BEARINGDFLOAD Q BEARING LESS THAN FACTOR OF SAFETY DEPTH DEPTH t LOAD DEPTH DEPTH LOAD DEPTH LOAD DEPTH SOILALLOWABLE7 OK7 ` KSF) (FT) (FT) (KSF) (FT) KS (F F.S.1 2.07 1.9 3.3 0.44 3.4 0.27 3.4 YES N/A YES 3.4.3 YES2 2.07 1.9 3.3 -0.35 3.4 -0.52 3.4 YES 1.60 YES ' 3.43 YES 3 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 YES N/A YES 0.00 YES 4 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 YES NIA YES' 0.00 YES; Check Check Check Check Checks if max bearing Greater: Max less than less than less than less than value Is less than than 1.5 value specified- specified specified' specified specified allowable of 4 allowable allowable allowable 00wabis load' cases NOTES: 1) THE FOUR LOAD CASES ARE LCt)DEAD+LIVE;LC2)DEAD+.75(WIND or.7SEISMIC)+0.75LIVE LC3)DEAD+WIND(or.7SEISMIC);AND LC4).6DEAD+WIND(or.7SEISMIC) 2) USE ONLY FOR SQUARE FOOTINGS,CONSTRAINED BY A DRIVE SLAB OR PUMP ISLAND 3) REQUIRED DEPTH TO RESIST LATERAL LOADS BASED ON CONSTRAINED PIER DESIGN 4) BEARING LOADS FOR ALLOWABLE CHECK DO NOT INCLUDE WEIGHT OF FOOTER,ISLAND OR MISC \ THESE WEIGHTS USED TO CHECK UPLIFT ONLY Page 1