Loading...
ResCheck • REScheck Software Version 4.6.4 Compliance Certificate Project CHRISTOPHER DWYER Energy Code: 2015 IECC Location: Glens Falls, New York 288.-1-65 RC-0467-2018 Construction Type: Single-family Williams,--Tom- C;hr\S bv\1y�,�/ Project Type: New Construction �J 1232 IN Mountain Rd Conditioned Floor Area: 1,140 ft2 Glazing Area 13% Garage Alterations 1140 s.f. Climate Zone: 6 (7635 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 1232 West Mountain Road Christopher Dwyer Queensbury, NY 12804 1232 West Mountain Road Queensbury, NY 12804 Compliance. Passes using UA trade-off Compliance: 2.9%Better Than Code Maximum UA: 1055 Your UA: 1024 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Assembly or Cavity Cont. U-Factor UA Perimeter R-Value R-Value Ceiling 1: Flat Ceiling or Scissor Truss 1,140 38.0 0.0 0.030 34 Wall 1:Wood Frame, 16" o.c. 1,088 13.0 0.0 0.082 76 Window 1: Wood Frame:Double Pane with Low-E 105 0.310 33 Door 1: Solid 20 0.200 4 Door 2: Glass 40 0.310 12 Floor 1: Slab-On-Grade:Unheated 1,360 60.0 0.636 865 Insulation depth: 6.0' Compliance Statement: The proposed building design described here is consistent with the building plans, specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.4 and to comply with the mandatory requirements ' in e REScheck Inspection Checklist. G. PETER JENSEN ��� ////O Name-Title 17 WES I KUAIJ ignaturef Date SOUTH GLENS FALL' / ' QED ARC NEW YORK 1280? •Eb (518)798-1Rcq 4uc, Ircl ER Jets,ti'� Q cr 41 e c7 n l 0,2602V „E- Project Title: CHRISTOPHER DWYER �r�OF Hs*yOP Report date: 11/19/18 Data filename: C:\Users\Peter\Documents\REScheck\Chris Dwyer.rck Page 1 of 9 wt'�. F�re, _.:.fi e.-}. r t7- '�'�C n! .'�!!. 's 'N ;, c`4 • • • ' t}Z L,;. e .,go� k 1..�t: .� �; <S ` '4• _ `4 gXr • > "'+.' :} �, 'i,.M, ,c_„ -j. .,�./ � .. ff ,+Ft ri:sb 59 Ek. .P?� .'' ; 7 °j` ��1�yn., i���„''•o � ''�` ' '`YxA "'f 'et•35Iq� �aA a1R� . � i.l� � . ��¢¢ S L `C Ya Z ems. a._ ... • t4 4 0 0r/ 0 REScheck Software VersionChecklist 4.6.4 Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions Si Req.ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR1]' energy code compliance for the d, building envelope.Thermal [Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3]' lighting and mechanical systems. [Not Observable „) Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual 5 based Btu/hr Btu/hr ❑Does Not [PR2)2 on loads calculated per ACCA Cooling: Cooling: 42; Manual J or other methods Btu/hr Btu/hr ❑Not Observable approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: CHRISTOPHER DWYER Report date: 11/19/18 Data filename: C:\Users\Peter\Documents\REScheck\Chris Dwyer.rck Page 2 of 9 . Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.2 Slab edge insulation R-value. R- R- ❑Complies See the Envelope Assemblies [Foil' ❑ Unheated ❑ Unheated EDoes Not table for values. ❑ Heated ❑ Heated [Not Observable ❑Not Applicable 402.1.2 Slab edge insulation ft ft ❑Complies See the Envelope Assemblies [FO3]1 depth/length. ❑Does Not table for values. .1* ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [F011]2 to protect exposed exterior ['Does Not insulation and extends a minimum of 6 in. below grade. ❑Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [F012]2 controls installed. ❑Does Not 0' ❑Not Observable ElNot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: CHRISTOPHER DWYER Report date: 11/19/18 Data filename: C:\Users\Peter\Documents\REScheck\Chris Dwyer.rck Page 3 of 9 Section Plans Verified Field Verified Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-factor. U U ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 [Not Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.3.6, DNot Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. ❑Not Observable ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR2O]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate 52.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >= R-6 where<3 inches.Supply and ❑Not Observable return ducts in other portions of ❑Not Applicable the building insulated>= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105°F or chilled fluids ❑Does Not below 55°F are insulated to>_R- 3 ❑Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR1812 >_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: CHRISTOPHER DWYER Report date: 11/19/18 Data filename: C:\Users\Peter\Documents\REScheck\Chris Dwyer.rck Page 4 of 9 Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: CHRISTOPHER DWYER Report date: 11/19/18 Data filename: C:\Users\Peter\Documents\REScheck\Chris Dwyer.rck Page 5 of 9 Section Plans Verified Field Verified Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not provided. ❑Not Observable ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall [IN3]1 exterior,the exterior insulation Mass [1] Mass ❑Not Observable requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: CHRISTOPHER DWYER Report date: 11/19/18 Data filename: C:\Users\Peter\Documents\REScheck\Chris Dwyer.rck Page 6 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions &Req.ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel ❑Not Observable 402.2.6 [FI1]1 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [F12]1 Blown insulation marked every 300 ftz. [Not Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies (F122]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. [Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [F13]1 insulation .12-value of the ❑Does Not adjacent assembly. ['Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50= ❑Complies [F117]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa.For rough-in ❑Not Observable tests, verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [FI27]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g.across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [F124]1 by manufacturer at<=2%of ❑Does Not design air flow. [Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [F19]2 installed for control of primary ElDoes Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. ElNot Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI10]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [FI11]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: CHRISTOPHER DWYER Report date: 11/19/18 Data filename: C:\Users\Peter\Documents\REScheck\Chris Dwyer.rck Page 7 of 9 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions &Req.ID 403.6.1 All mechanical ventilation system DComplies [FI25]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. Not Observable ❑Not Applicable 403.2 Hot water boilers supplying heat DComplies [FI2612 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water [Not Observable temperature based on outdoor DNot Applicable temperature. 403.5.1.1 Heated water circulation systems DComplies [F128)2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply DNot Observable pipe.Gravity and thermos- DNot Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems DComplies [F129]2 comply with IEEE 515.1 or UL ❑Does Not 515.Controls automatically adjust the energy input to the DNot Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that DComplies [FI30]2 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated ['Not Observable water source through a cold DNot Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104°F. 403.5.4 Drain water heat recovery units DComplies [F131]2 tested in accordance with CSA ❑Does Not B55.1.Potable water-side pressure loss of drain water heat ❑Not Observable recovery units< 3 psi for DNot Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units< 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent DComplies [FI6]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage :Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have DComplies [FI23]3 no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: CHRISTOPHER DWYER Report date: 11/19/18 Data filename: C:\Users\Peter\Documents\REScheck\Chris Dwyer.rck Page 8 of 9 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions &Req.ID 401.3 Compliance certificate posted. ❑Complies [F17)2 ❑Does Not ['Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI1813 mechanical and water heating ❑Does Not systems have been provided. [Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: CHRISTOPHER DWYER Report date: 11/19/18 Data filename: C:\Users\Peter\Documents\REScheck\Chris Dwyer.rck Page 9 of 9