Loading...
Signed Inspection Report (02-18-2020) (4).pdfINSPECTION WORKSHEET (BINS-000921-2020) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:AST-0593-2019 Case Module:Permit Inspection Date:Tue Feb 18, 2020 Inspection Status:Partial Pass Inspector:John O'Brien Inspection Type:Building Insulation Job Address:Parcel Number:133 Jenkinsville RD Queensbury, NY, 12804 279.-1-21 Contact Type Company Name Name Architect Rucinski-Hall Architecture Granted Permission TOWN OF QUEENSBURY REC DEPT Primary Owner TOWN OF QUEENSBURY REC DEPT Concrete Contractor A.J. Catalfamo Construction Co., Inc. Checklist Item Status Building Inspector Notes Failed 2/3/20 Insulation Not Approved Remaining Items: - Remove a sheet of fire retardant plywood from each wall to verify the insulation in wall has been installed correctly. - Provide documentation that states that R38 insulation has been installed in ceiling and R21 has been installed in the exterior walls as per the approved COMcheck Energy Code Compliance Report. - Provide documentation that the windows and insulated door have the correct U value as per the approved COMcheck Energy Code Compliance Report. 2/18/20 Insulation Partial Approval - Insulation documentation received from manufacturer. The installation verified and approved in accordance with the approved COMcheck. Remaining Items: - Provide documentation showing what the U value is for the windows and exterior doors. - Verify perimeter of windows and doors have been sealed with sprayfoam. - Schedule blower door test for addition. Window Sealing Failed Feb 18, 2020 Page (1) INSPECTION WORKSHEET (BINS-000921-2020) Checklist Item Status U Factors = .3 cfm for windows, .5 cfm for doors Failed Insulation Residential Check Commercial Check Failed 2/3/20 Insulation Not Approved Remaining Items: - Remove a sheet of fire retardant plywood from each wall to verify the insulation in wall has been installed correctly. - Provide documentation that states that R38 insulation has been installed in ceiling and R21 has been installed in the exterior walls as per the approved COMcheck Energy Code Compliance Report. - Provide documentation that the windows and insulated door have the correct U value as per the approved COMcheck Energy Code Compliance Report. 2/18/20 Insulation Partial Approval - Insulation documentation received from manufacturer. The installation verified and approved in accordance with the approved COMcheck. Remaining Items: - Provide documentation showing what the U value is for the windows and exterior doors. - Verify perimeter of windows and doors have been sealed with sprayfoam. - Schedule blower door test for addition. Blower Door Test Failed Door / Window Sealed (No Insulation)Failed Feb 18, 2020 Page (2) O'Brien, John