Loading...
2008-575 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20080575 Date Issued: Tuesday, August 25, 2009 This is to certify that work requested to be done as shown by Permit Number P20080575 has been completed. Location: 1208 RIDGE Rd Tax Map Number. 523400-279-018-0001-011-000-0000 Owner. JUDITH RICCIO Applicant: JUDITH RICCIO This structure may be occupied as a: Residential Addition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the r: 4 4x- property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20080575 Application Number. A20080575 Tax Map No: 523400-279-018-0001-011-000-0000 Permission is hereby granted to: JUDITH RICCIO For property located at: 1208 RIDGE Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: JUDITH RICCIO 1208 RIDGE Rd Residential Addition $82,000.00 QUEENSBURY,NY 12804 Total value $82,000.00 Contractor or Builders Name/Address Electrical Inspection Agency HILLTOP CONSTRUCTION 51 CROWLEY Rd HUDSON FALLS,NY 12839-0000 Plans &Specifications 2008-575 594 SQ FTsecond story- RESIDENTIAL ADDITION $75.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Wednesday,June 02, 2010 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the �,e�of Queonsburr, f� i T�ge�y,June 02, 2009 A .:�..` for the Town of Queensbury. SIGNED BY Director of Building&Co e Enforcement 0. _-_.-.__---- ""--OFFICE USE ONLY -_--_ _-I -----�-""- - -_ .-_. . . . - --. .I -1-1 - -S�S--- -- TAX MAP NO. y PERMIT NO FEES: PERMIT_ RECREATION_ __ENGINEERING___ ____ _ (If applicable) _______________________ ----------------- --------- -- ------.-_------_-. .------.. -_ -_ ------- _.-- PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUAINCE OF A VA ID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER+ I ot)4, CttCtOn OWNER-qI hi O1I j J �1 C C 1 O ADDRESS: i (, uu) I�. hud_s5nRAS ADDRESS: I(a®g gi d c'e Rao-A PHONE NOS. q q�-6-33 F PHONE NOS. Iq ,Z 3g,5 r' CONTACT PERSON FOR BUILDING&CODES COMPLIANCE:TO Yn � ►OrfAf PHONE:�01- LOCATION OF PROPERTY:_JaO S )A 6,e, ROcxd 01 ee n U-ry SUBDIVISION NAME: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT Z APPLY TO YOUR g a ❑ uj PROJECT p Q�Q p O N Cl) to LL w 0 W OJu- LLOU- w Q 4�U Z Q Q NU) 0 L OLL 42uu SINGLE FAMILY 5 i , r 2I TWO-FAMILY MULTI-FAMILY(NO._� TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER Town of Queenshurlt - Communitil 0eveloputent ( 1fice ' Dail Road, OIrr rx�lu�ry. ��1 l 04 s- IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST: Ua I00 0 FUEL TYPE: () I L HEAT TYPE? iZ-%HOW MANY FIREPLACE(S) AND/OR WOODSTOVES(S): ZONING CATEGORY: {� ARE THERE WETLANDS ON THIS SITE? p IS THIS A HISTORIC SITE? 1 1© PROPOSED USE OF BUILDING OR ADDITION: ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? *Please complete a separate Application for"Fuel Burning Appliances&Chimneys'available in our office I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above. Signed Director of Building & Codes: 761-8256 (for questionsCQUESTIONS CALL 761-8266 OR EMAIL regarding Building Permits, construction codes or septica�queensbury.net systems) ITE FOR MORE INFORMATIONZoning Administrator: 761-8218 (for questions regarding gueensbury.net required permits, the permit process, application requirements or to schedule an appointment) -------------------------------- - --- _. .---- _.. . . _. . _ a . . . . . . . . . . . . .. . . . _ .. _ . _ . _ . . ._._._- This application/ proposed action described ; Permission is hereby granted to the above herein is found to be in accordance with the Applicant to erect or alter the building described zoning Laws of the Town of Queensbury. herein in accordance with said Application: , ; ZONING APPROVAL DATE ; % BUILDING&CODES APPROVAL DATE o F(nwn of Queeitshnrl/ • Co m ullih/ I V11cloInu1'rt! t)ffil i_4 2 I;ui/ R'oIIIl, ( 11i'I'll ,b I/ Check Residential Plan Review: One& Two Family Dwellings Y/N/N/A Al AJ (2 ull sets of plans Over 1,500 sq. ft.—Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 50 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space ove/Below grade, 5.7 sq. ft. Grade,5.0 sq. ft. 24"(h)x 20"(w)min. 44"Max. Height above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofmg/Waterproofing Materials On Plans Foundation Drainage On Plans, if required 6' Drop in 10' Exterior Grade raming Cross Section For Each Roof Line, Vertical Fire Stopping Every 10' Where LY uired ce and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls 44 P tforms At Exterior Doors irway Headroom 6' 8' All Stairs 36"Width Stair Run and Rise Winder Run and Rise piral Not Allowed From 2 Story /Sfnoke Detectors Battery Backup and Proper Location B throom Fixtures Proper Clearance all Width, 36"min. V�Iandrails More Than Four Risers On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4" in Ht. afety Glazing Notes For Required Areas arage Fire Separation [?�ge Floor Sloped Attic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Outside Lowest Sleeping Area, On Every Level& Interconnected Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed Queensbury Building & Cade Enforcement - R sidentiai Final Inspection Office No. (518)761-8256 Arrive: arrf/pr epart: am/pm Date Inspection request received: Inspect s Initials: \\JJ _ L NAME: tf PERMIT LOCATION: C' DATE: jF TYPE OF STRUCTURE: Comments: Yes No PUA ,V Building Number Address visible from road Chimney Height/"B"Vent/Dlrect Vent Location Fresh Air Intake rl 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs decks more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade I tenor viva /trim/doors/main entrance 36 inches athroom/Kitchen watertight Safety glazing/Window' s safe lazin Interior Smoke Detect /Carbon Monoxide Detecto Every level: ry Bedroom: Outside every bedroom are . Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access,l sq.ft.-150 s .ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within One of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%"G sum ��) Basement stairs closed rise>4 inches ����� Garage Floor Pitched Garage fi roofi T' hour fire door/door closer Duct wont Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if requlred Oka to issue C/C or C 10 Temporary/Permanent 06ullding&Codes FormslBuilding&Codes\lnspection FonnslResidential Final Inspection Form revised_100405.doc;Revised January 7,2008;Revised 6/2601 Queensbury Building & Code Enforcement - Resi ential Final Inspection Office No. (518)761-8256 Arrive: 'y am/pm Depart: am/pm Date Inspection request received: Inspect 's Initials: NAME: PERMIT#: LOCATION: DATE: TYPE OF STRUCTURE: Comments: Y o /A 4' Building Number Address visible from road Chimney Height/"B°Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbina Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs decks tins more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapp2d Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches �a Bathroom/Kitchen watertight Get,,�,�,���� Safety lain /Window in stairwells safe Pain Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: d Outside every bedroom area: C6v i Inter Connected: Batteryup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 s .ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping stopp:sng finished basement 1,000 s .ft. Emeraency earess below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum''Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logo in Sealed or Glass n osur Final Electrical Final Survey Plot Plan Arc fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C 10 Temporary/Permanent L:1Building&Codes FormslBuilding&Codesllnspec ion Forms\Residenbal Final Inspection Fonn_revised_100405.doc;Revised January 7,2008;Revised 626/08 !a-1z- RCAA Rough Plumbing / Insulation Ins tion Report a Office No. (518) 761-8256 Date Inspecti n�quest received: Queensbury Building & Code Enforcement Arrive: U - am/pm part: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's nitials: ,,I NAME: PERMIT ##: LOCATION: INSPECT ON: - - TYPE OF STRUCTURE: Y N NIA Rough Plumbi /Nail Plates Plumbing Vent/Vents in Place 1 %inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/chan a of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head r 15 minutes Insulation/ esidential Check/Commercial Check lVvekyriTimilsar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct to COMMENTS: Rough Plumbing Insulation Report.nevised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Fires opping Inspection Rei;j Office No. (518)761-8256 Date Ins ' truest received: Queensbury Building &Code Enforcement Arrive: am/ rt: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's I ' ials: NAME: R1 1 PERMIT#: U LOCATION: © INSPECT ON: TYPE OF STRUCTURE: Framing Y N N/A COMMENTS: Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D naus each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on enter Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour 13, ur rFirestopping 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 518 inch Type X Garage side 5/8 inch Type X Ceiling1wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. eM 5.7 sf above/below grade 5.0 sf grade LABuilding&Codes Fortes-OLMuiiding&Codesmnspec Lion FormsTraming FaestopphV iropedion ReporLdoc Revised January 7,2008 A,v�So� Rough Plumbing / Insulation Insp tion Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/p TVZ�pe art: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: a/' PERMIT #: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N NIA Rough Plumbing I Oail Plates ents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.1 for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Dud/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No dud tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Septic Inspection Re 0 Office No. (518) 761-8256 DateL n r ue r ed: al Queensbury Building &Code Enforcement Arriv epart: a 742 Bay Rd., Queen u , N 12804 Insp s• R, NAME: �a E IT NO.: LOCATION: PECT ON: '9 RECHECK: Comments and/or diagram Soil T Sa T of Water: Munici ell Wat Waterline se ration distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' + - Y N N/A Absorption Field: Total length Z ft. Length of each trench Lft. Depth of trenches ` — Z ft. Size of Stone Ak Z— Seepage Pits: Number Size: x Stone Siie:-- Piping Size Type Building to tank lI Tank to Distribution Box I �� D LEvE��Q5 tN!�TRt� Distribution Box to Field Pit I pE� Opening Sealed: Y N End Ca Y N Inlet/Outlet Pipes&BafFles Y N Location Separations Foundation to tank ft. Foundation to absor tion ft. Separation of Pits ft. Conforms as r Plot Plan Y �}C C F QTA F t F Engineer Report and As-Built Y N �� '\L Location of System on Property: Front ear Left Side �RlghtSide Middle Front Middle Rear System Use Status: pproved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Last revised 06/18/07 U\Building&Codes Forms-01-1)\Building&Codes\Inspection Forms\Septic Inspection Report.doc l 00 �� Framin / FirestoPPn InspectionOp—oft Office No. (518)761-8256 Date In uest received: Queensbury Building &Code Enforcement Arrive: a Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspect is Initials NAME: RPERMIT#: — LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N NA COMMENTS Framing Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 w 16 gauge 8 16D nags each side Draft stopping 1,000 sq. ft. floor trusses Anchor Botts 6 ft. or less on center Ice and water sh' id 24 inches from wall 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side h inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. C 5.7 sf above/below grade 5.Q sf grade "Fal&Codes Forms-OLD�tiicift&CodeS4r pec taming Firesiopp"InspOOM Reporidoe Revised January 7,2000 09- S- ?Y_ REScheck Software Version 4. 1 A Compliance Certificate Project Title: hilltop/riccio Report Date: 10/19/08 Data filename:Untitled.rck Energy Code: 2007 New York Energy Conservation Construction Code Location: Warren County,New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 10% Heating Degree Days: 7635 Construction Site: Owner/Agent: Designer/Contractor: 1208 ridge rd. queensbury,NY 12804 . . Compliance:16.5%Better Than Code Maximum UA:103 Your UA:86 Gross Cavity Cont. Glazing UA Assembly Area or R-Value R-Value or D.. Perimeter LI-Factor Ceiling 1:Flat Ceiling or Scissor Truss 570 38.0 0.0 17 Wall 1:Wood Frame, 16"o.c. 784 21.0 0.0 40 Window 1:Vinyl Frame:Double Pane with Low-E 79 0.350 28 Floor 1:All-Wood Joist/Truss:Over Outside Air 30 30.0 0.0 1 Boiler 1:Other(Except Gas-Fired Steam)80 AFUE Air Conditioner 1:Electric Central Air 13 SEER The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems have been designed to meet the 2007 New York Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. Name-Title Signature Date NE 1""y KL1Ty� E Jt �u Z of Project Title: hilltop/riccio Report date: 10/19/08 Data filename: Untitled.rck Page 1 of 4 CREScheck Software Version 4.1.4 NJI Inspection Checklist Date: 10/19/08 Ceilings: ❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation Comments: Above-Grade Walls: ❑ Wall 1:Wood Frame,16"o.c.,R-21.0 cavity insulation Comments: Windows: ❑ Window 1:Vinyl Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Floors: ❑ Floor 1:All-Wood Joist/Truss:Over Outside Air,R-30.0 cavity insulation Comments: Heating and Cooling Equipment: ❑ Boiler 1:Other(Except Gas-Fired Steam):80 AFUE or higher Make and Model Number: ❑ Air Conditioner 1:Electric Central Air:13 SEER or higher Make and Model Number: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation. Vapor Retarder: ❑ Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment are identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. ❑ Insulation R-values and glazing U-factors are clearly marked on the building plans or specifications. ❑ Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building are insulated to at least R-11. ❑ Return ducts in unconditioned attics or outside the building are insulated to at least R-6. ❑ Supply ducts in unconditioned spaces are insulated to at least R-11. ❑ Return ducts in unconditioned spaces(except basements)are insulated to R-2.Insulation is not required on return ducts in basements. Duct Construction: ❑ All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric,or tapes.Tapes and mastics are rated UL 181A or UL 181B. Project Title: hilltop/riccio Report date: 10/19/08 Data filename: Untitled.rck Page 2 of 4 Exceptions: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). Lj The HVAC system provides a means for balancing air and water systems. Temperature Controls: Lj Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: Separate electric meters exist for each dwelling unit. Fireplaces: Lj Fireplaces are installed with tight fitting non-combustible fireplace doors. ❑ Fireplaces have a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: ❑ Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: Cj All heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps have a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Project Title: hilltop/riccio Report date: 10/19/08 Data filename: Untitled.rck Page 3 of 4 'Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Temperature("F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(°F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Project Title: hilltop/riccio Report date: 10/19/08 Data filename: Untitled.rck Page 4 of 4