Loading...
Manual JgaFOND :¥Project Summary Xo,Entire House&Adirondack P&M edK¢ £20 Box 562,Gans Fal,NY 12801 Phone:518-793 3883 Em:ifogadeondackpen com Job: Date:Feb 04,2020 By:Adirondack P&M,Ine. EeeeaSrojectInformation For.Monsour Large Ranch 308.18-2-29.1 RC-0055-2020 Monsour Enterprises LLC 7 Kimberly Ln Weather:Glens Falls AP,NY,US Winter Design Conditions Summer Design Conditions Outside db 4 °F Outside db 85 °F Inside db 68 °F Inside db 75 oF Design TD 72°F Design TD 10 °F Daily range M Relative humidity 50 % Moisture difference 26 gril Heating Summary Sensible Cooling Equipment Load Sizing Structure 29271 Btuh Structure 14377 Btuh Ducts.9 Btun Ducts 0 BtuhCentralvent(0 fm)0 Btun Central vent (0 cfm)0 Btuh (none)(none)Humidification ©Btuh Blower 0 Btuh Piping 9 Btuh Equipment load 29271 Btuh Use manufacturer's data n Rate/swing multiplier 0.90InfiltrationEquipmentsensibleload12939 Btuh Method ‘Simplified Latent Cooling Equipment Load SizinConstructionquality‘Average oe 2 Fireplaces 4 (Average)Structure 5980 BtuhDucts0BtunCentralvent(0 cfm)0 BtuhHeatCool(none)Area (2)‘374 3748 Equipment latent load 9980 Btuh Volume (f?)0 9 Air changes/hour 0.90 0.40 Equipment Total Load (Sen+Lat)18919 Biuh Equiv.AVF (cfm)0 0 Reg.total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make=Amana Make AmanaTrade©AMANA HEATING AND AIR CONDITIO.Trade©AMANA Model AMSS960402BN Cond ASX130181D AHRI ref 7368085 Coil ACNF180616D AHRI ref 5996190 Efficiency 96.1 AFUE Emiciency 10.8 EER,13 SEER Heating input 49000 Btuh Sensible cooling 14760 Btuh Heating output 38000 Btuh Latent cooling 8040 Btuh ‘Temperature rise 62 °F Total cooling 16800 Btuh ‘Actual airflow 560.cfm Actual air flow 560 cfm Air flow factor 0.019 cfmyBtun Airflow factor 0.039.ofvBtuhStaticpressure0inH20.Static pressure 0 in H20, ‘Space thermostat Load sensible heat ratio o7t Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. Tips nceore 2020 Feb04 103327 RightSute®Universal 2019 _aments\Wighsof HVACWonsourRanchSGFZ010 up Gale = Page MONDAG,Manual S Compliance Report x “2 Entire House &Adirondack P&M PO Box 562,Glens Fal,NY 12801 Phone:518.73-3883 Em:nfo@adrondackpm com Job: Date:Feb 04,2020 By:Adirondack P&M,Ine. Project Information For:Monsour Large Ranch Cooling Equipment Design Conditions Outdoor design 0B:85.0°F Outdoor design WB:70.8°F Indoor design DB:©75.0°F Indoor RH:50% Sensible gain:14377 Btuh Latent gain:5980 Btuh Total gain:20357 Btuh Estimated airflow:622 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type:Split AC Manufacturer Amana ‘Actual airflow:560 Sensible capacity:11760 Latent capacity 5040 Total capacity’16800 Btuh Btuh Btuh Model:ASXC160241C 82%of load 84%of load 83%of load SHR:70% Entering coil DB:75.0°F Entering coil WB:62.5°F Design Conditions Outdoor design DB:-3.5°F Indoor design DB:68.0°F Heating Equipment Heat loss’29271 Btuh Manufacturer's Performance Data at Actual Design Conditions Equipment type:Gas fumace Manufacturer.Amana ‘Actual airflow:560 cfm Output capacity:58000 Meets all requirements of ACCA Manual S. Btuh Model:AMVC960603BN 130%of load Entering coil DB:68.0°F Temp.rise:50 °F +H wrightsoft RightSute®Universal 2019 19.0.08 RSU21843 caments\Wightsot HVACWonsourRanchSGF2010.up Calc=MIT FrontDoor faces:W ‘20 Feb-04 103827 age 1