Loading...
2008-607 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CE RT I F I CAT E (31FE7 OCCUPANCY Permit Number. P20080607 Date Issued: Tuesday, January 19, 2010 This is to certify that work requested to be done as shown by Permit Number P20080607 has been completed. Location: 13 ROSE Ln Tax Map Number. 523400-308-010-0002-066-000-0000 Owner. JAMES D KRAMAR Applicant: JAMES D KRAMAR This structure maybe occupied as a: Residential Addition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the p Director of Building&Code t-riforce"Aient Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20080607 Application Number. A20080607 Tax Map No: 523400-308-010-0002-066-000-0000 Permission is hereby granted to: JAMES D KRAMAR For property located at: 13 ROSE Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: JAMES D KRAMAR 13 ROSE Ln Residential Addition $16,000.00 QUEENSBURY, NY 12804-0000 Total value $16,000.00 Contractor or Builder`s Name/Address Electrical Inspection Agency Plans &Specifications 2008-607 360 sq ft residential addition $75.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday, December 01,2009 (If a longer period is required,an application loran extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T of ;:PIW o ecember 01, 2008 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement si ---------------------, PROJECT NAME: OFFICE USE ONLY STAFF INITIALS: ' , DATE: } BUILDING PERMIT SUBMISSION - CHECKLIST FOR: MULTIPLE DWELLING or COMMERCIAL PROJECTS 1. Building Permit Application Completed? YES �NO ! N /A 2 Energy Form or Checkmate Energy Code Compliance 3 Forms Complete? (2-copies) Energy Code Inspector's Report from Checkmate 3. Program? (2-copies) Septic application completely filled out? 4. ° (if applicable) 5. Electrical Inspection Form complete? t }W 6. Two (2) sets of the plans each of the following: YES i NO N /A a. Floor plans (s)? ! b. Foundation plan? y t c. Cross sections (s)? d. Elevations? � e. Design loads including floor, snow load, and wind bad? ' f. Seismic design (required after January 2003)? s g. Plans signed and sealed by registered architect or engineer? h. Window and door schedule? - t I rTwo (2) site plans showing location of the structure to be ! _ built, location of well or water lines, location of septic 7' system stem or sewer line with all setbacks and separation E - distances shown, and all improvements to the prop? 3 8. ! Solid Fuel Burning or Gas Appliance Form (if applicable)? I { � t r 9. Driveway Permit Town of Queensbury • Community Development Office • 742 Bay:Road, Queensbury, NY 12804 ___________________________________, i OFFICE USE ONLY PROJECT NAME: STAFF INITIALS: BUILDING PERMIT SUBMISSION ! DATE: CHECKLIST FOR: '---------------------- SINGLE FAMILY DWELLING 1. Building Permit Application Completed? YES} NO N /A `. i 2. ' Energy Form or CheckMate Energy Code Compliance ! I Forms Complete? (2-copies) 3 Energy Code Inspector's Report from Checkmate Program? Pro r 9 (2-copies)_ ...._............_.................._s._..____._____ t Septic application completely filled out? 4. (if applicable) 5. = Electrical Inspection Form complete? I 6. Two (2) sets of the plans each of the following: 1 YES ' NO N /A I 1 a. Floor plans (s)? 3 t j b. Foundation plan? i c. Cross sections (s)? ; I d. Elevations? i e. Window and door schedule? i ; f. Natural Light, Ventilation and Emergency Egress I Requirements? g. Plans signed and sealed by registered architect or engineer? _ _ Two (2) site plans showing location of the structure to be 7. ' built, location of well or water lines, location of septic system or sewer line? 8. ' Setbacks from property lines to new structure? i -- $ Setbacks to neighboring wells and septic systems, P including_onsite well and septic systems if applicable)? _ ' E 9. ? Driveway Permit? ! i Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 B 12-LTR 11-05 ......I.............. 7 FFICE USE ONLY I TAX MAP NO. PERMIT NO. FEES: PERMIT RECREATION ENGINEERING ; (If applicable),. ; PRINCIPAL STRUCTURE; APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A\VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER:L,i4 ,-EAI l 15-11Gf C'Onl�;��c#��S OWNER: aA-rV\ >y A-In c ADDRESS: v.O .�� \0� Z-- C, 1Zu� S� ADDRESS: I �GS L.n , PHONE NO PHONE NOS. CONTACT PRSR FOR BUILDING &CODES COMPLIANCE: (>h13 �OckQCI'PHONE: LOCATION OF PROPERTY: 1 'R-�5 t-- Q v S lov u HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPROVAL? ❑ YES i, NO IF SO, INDICATE APPLICATION NO. AND DATE OF APPROVAL: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT z APPLY TO YOUR z 0 a Cf W '�`- Uj PROJECT 0 < 00 F: O F: O = _ W _jti u ti w Q dLoU w o Cj Z O I� O I= W u1 Z z ¢ a CO Ncn 0u. F- u_ a = � SINGLE FAMILY TWO-FAMILY MULTI-FAMILY (NO. of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST: l Dad _ FUEL TYPE: HEAT TYPE: Rc i P,�sr *HOW MANY FIREPLACE(S): AND/OR WOODSTOVES(S): 0 ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? IS THIS A HISTORIC SITE? tJ 6 / PROPOSED USE OF BUILDING OR ADDITION: U �' c�c✓t l S "�� r1� *Please complete a separate Application for"Fuel Burning Appliances&Chimneys" available in our office Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 B 3-LGL 11-05 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? O ARE THERE EASEMENTS ON PROPERTY? 1 acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. i acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree agree to the above. Signed Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) ; Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: ; 00 BUILDING & CODES APPROVAL ; ZONING APPROVAL 10 o DATE ; DATE QUESTIONS 7 CALL 761-8256 OR EMAIL codes(Raueensburv.net Office Use Only VISIT OUR WEBSITE FOR MORE INFORMATION Operating Permit Issued: Yes No www.aueensbury.net Occupancy Type: Construction Classification: Assembly Occupancy Limit: Special Conditions: p Town of Queensbury - Community Development Office - 742 Bay Road, Queensbury, NY 12804 Queensbury Building & Code Enforcement - Residential Final I ction � lice No. (518)761-8256 Arrive: Ls �• a � D Inspection request received: Inspector's Initials: NAME: PE #: LOCATION: __ � DA : TYPE OF STRUCTURE: Comments: N I ,V BuildingNumber Address visible from road / /_ 0 7 Chimney Height/"B'Vent/Direct Vent Location ey Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors _ Handrail 4 or more risers Guards at stairs deckspatios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to silt plate Gas Valve shut-off a sed/regulator 18 inches above race Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells salopy glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, i .ft:150 s .ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'A'Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct worts Sealed propedy Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required h Flood Plain Certification,if required 1 ° Okay to issue C!C or C 10 1 Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection FormslResidential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08 Rough Plumbing / lnsula on Inspe 'on Report Office No. (518) 761-8256 Date Inspection r Queensbury Building Code Enforcement Arrive: p art: �aF�-pm 742 Bay Road, Queensbury, NY 12804 Insp is Initi I NAME: PER #: LOCATION: INS CT ON: TYPE OF STRUCTURE: Y N NIA Rough Plumbing/Nail Plates Plumbing Vent/Vents in Place 1 Y2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping ea 50 P.8.1 fo 15 minutes Insulation�!Aesidential Check/Commercial Check T ek o imilar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct I Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, remised February 15,2005, revised January 7,2008 Rough Plumbing / insulation Inspeelfi6n Report Office No. (518) 761-8256 Date Inspection rfeq Queensbury Building &Code Enforcement Arrive: f aart: ', sam/ //742 Bay Road, Queensbury, NY 12804 Ins isInitialNAME: PERLOCATION: INSP TYPE OF STRUCTURE: Z-- Y N N/A Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pre ure Test ater Supply Piping Air .I for"'15 minutes Insulation/Pbsidential Check/Commercial Check imilar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspectio j3n Re Office No. (518)761-8256 Date I " n �ecei Queensbury Building &Code Enforcement Arrive: T)s �742 Bay Road, Queensbury, NY 124 Inspecto Ind80ia f NAME: L� ►— 'PERMIT LOCATION: KQ sg, INSPECT ON: -Cq OF STRUCTURE: Y N Framing NIA COMMENTS Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging f Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %W 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour F' wall 2,'3 4 hour Firestopping -Pareftlion sealed 16 inch insulation in cavity min. Garage Fire Separation House side's inch or 518 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. CM 5.7 sf above/below grade 5.0 sf grade LABuilding&Codes Forms-=\Suildirq&Codesvnspection FonnsTrarning Firestoppirp Inspection ftwtdoc Revised January 7,2006 L _ Framing / Firestopping Ini io R 6it Office No. (518)761-8256 Date Inspection reque i Queensbury Building &Code Enforcement Arrive:jl a a� 742 Bay Road, Queensbury, NY 12804 Inspector's Initial NAME: r G PERMIT#: T� LOCATION: INSPECT ON: TY OF STRUCTURE: Y N NIA Framing COMMENTS: ss 22"x 30' minimum of e_c-NcAtJE I- IV t-,t tyS 6, Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12° O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 18D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center I and water shield 24 inches from wall ire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. mop ' Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling1wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. OM 5.7 sf above/below grade 5.0 sf grade �� EQ O t') N10tJ o LABuilding&Codes Forms-OLMSuilding&Codes4rapecxion FormeTraming Fig Inspection Repottdoc Revised January 7,20M Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection req re Queensbury Building &Code Enforcement Arrive: rt: = a pm_� 742 Bay Road, Queensbury, NY 12804 Inspector's Initials. NAME:-- IBC R A to F R IPERMIT# LOCATION: t,a R O"-)F L INSPECT ON: — TYPE OF STRUCTURE: Framing Y N NIA COMMENTS: Attic Access 22" x 30" minimum Jack Studs/Headers Braking/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Q Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LABuiiding$Codes Forms-=Suilding&CodesUnspection Forrnewrarning Fffestopphv inspection Report.doc Revised January 7,2008 Framing / Firestopping Inspection Report tl Office No. (518)761-8256 Date 1 n 1,) Queensbury Building &Code Enforcement Arrive: rt: 742 Bay Road, Queensbury, NY 12804 inspector's niti NAME: ERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Framing Y N I WA COMMENTS: Attic Access 2T x W minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nags each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on genter Ice and water shield 24 inches from WAI -------------- Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cav' min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceilingfwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. CM 5.7 sf above/below grade 5.0 sf grade LABuilding&Codes Forms-OLD\Buildmg&Codes\lnspedm FonreTranft Firestopping Inspection Report.doc Revised January 7,2005 Framing / Fires opping Ihs 'e on R rt` Office No. (518)761-8258 Date Inspection reV' : Queensbury Building Code Enforcement Arrive: : ��a " .am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: /PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Framing Y WA COMMENTS: ccess 22" x 300 minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12°O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/ w 16 gauge 8 16D naus each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceilingfwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (M 5.7 sf above/below grade 5.0 sf grade LABuikting&Codes Fomns-OLD\Sukft&CodeMimmection FomtsTmning FndoppkV UMpection Report.doc Revised January 7,2006 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Ins pection\requr .ived: Queensbury Building & Code Enforcement Arrive: ? ` m/prxfl` part: _�' .am/ 742 Bay Road, Queensbury, NY 12804 Inspecto synitials`:_, NAME: I'-i R Pk M R PERMIT#: LOCATION: L3 Rc)")E- k INSPECT ON: 1 -- �--� -- TYPE OF STRUCTURE: Y N N/A Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 %inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping 'r/Head 50 P.S.1 for 15 minutes Insulation/Residential Check/Commercial Check . Tyyek or Similar Exterior Sealant Prop2r Vent, Attic Vent `t"y Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If uired unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing insuia m Report.revis+ed Nov 17 2003, revised February 15,2005, revised Januoy 7,2008 Framing I Frestopp� Inspection eport Office No. (518)761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart: wpm 742 Bay Road, Queensbury, NY 128N Inspector's Initials: NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: f i Y N WA COMMENTS: Fri Attic chess 2T x 30' minimum Jadc Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12°O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Wails Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each we Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on enter Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fi 4 hour Fie g e ion sealed 16 inch insulation in cavity min. Garage Fire Separation House side h inch or 518 inch Type X Garage side 5/8 inch Type X CeilingNTII Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LABuH&V&codes Fortis-OL Suildinq&codesNrspedion FoffnsTraminq FkodDppkV Inspection Report.doc Revised.lanua y 7,2008 Rough Plumbing / Insulatio Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart:�m/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: U' �— PERMIT#: - LOCATION: INSPECT ON: - TYPE OF STRUCTURE: Y N N/A Rough Plumbing/ ail Plates /Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain./Vent Air tHead 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head` 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Foundation Inspection Report Office No.(518)761-8256 Date Inspection reque Queensbury Building 8c Code Enforcement Arrive: m per- �{:ZLt ��m 742 Ba Rd. ueensb NY 12804 Y ,Q ury, Inspectors Initi C NAME: i I�F�i`i IZ iZMIT#: ( >AL LOCATION: i � �L h t L-��� _ INSPECT ON: TYPE OF STRUCTURE: ROD. Commenb Y N NA Footings Piers Monolithic Slab -` Reir nt in P �- e contractor is responsible for Providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purp2se on site. Foun n Willpm Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain.Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM F-/6 Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: k t� Queensbury Building&Code Enforcement Arrive: am/prp Departlt} ''pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: e rn K s PERMIT#: L- LOCATION: L� , t r �-�INSPECT ON: TYPE OF STRUCTURE: Comment J Y N N/A ootings ie-rs Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Fors\Building&Codes\lnspecbon Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: V40 am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: �� 6a NAME: r'��f PERMIT#: at LOCATION: /.3 af{ INSPECT ON: %Z% S TYPE OF STRUCTURE: Comments Y N NA Footings Piers Monolithic Slab -eht ghee- Reinforcement in Place The contractor is responsible for ua Ile' rnJ�L `�r1p 7 providing protection from freezing X /n e e,- for 48 hours following the placement G L of the concrete. �/ �jo� /W'1 5 Materials for this on site. �� j�f Foundation/Wallpour �J Reinforcement in Place OL.f,1 Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing rn�,c7e Footing Drain Daylight or Sump ,t / / I /I f. l�c�o � rs� Footing Drain Stone: 12 inch width f�iil o /cam a A 6 inches above footing ®� 6 mil poly for wet areas under slab re v1s a&{f Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Buiiding&Codes Forms\Building&Codes\In Fcxms\FourAdJon Inspection Report.doc Last printed 12/20/2005 9:24:00 AM f L� Foundation Inspection Report Office No.(518)761-8256 Date InM!5 d: Queensbury Building&Code Enforcement ArriveDepart. � pm 742 Bay Rd.,Queensbury,NY 12804 Inspect NAME: �-C� LOCATION: INSPECT ON: 7 — TYPE OF STRUCTURE: Comments Y NA Footings Monolithic Slab Reinforcement in Place The contractor is responsible for ( 1 —T providing protection from freezing l for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&CodeAInspec tion Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM REScheck Software Version 4.1.2 Compliance Certificate Project Title: KRAMAR RESIDENCE 4 SEASON ROOM Report Date: 11/11/08 Data filename:C:\Users\Allen\Desktop\Backup Files Folder\Business Files\HOUSE ADDITIONS,DECKS,3 SEASON ROOMS,ETC\3 &4 SEASON ROOMS\KRAMAR 4 SEASON ROOM\Kramar REScheck.rck Energy Code: 2007 New York Energy Conservation Construction Code Location: Saratoga County,New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 14% Heating Degree Days: 7244 Construction Site: Owner/Agent: Designer/Contractor: 13 Rose Lane James Kramar Allen Packard Queensbury,NY 12804 13 Rose Lane AI Packard Drafting Services Queensbury,NY 12804 16 Jacob Drive (518)858-2493 Gansevoort,NY 12831 518.745.1112 apackardjr@nycap.rr.com Compliance: Compliance:23.7%Better Than Code Maximum UA:556 Your UA:424 Gross Cavity Cont. Glazing UA Assembly Area or R-Value R-Value or D.. Perimeter U-Factor Ceiling 1:Cathedral Ceiling(no attic) 327 38.0 0.0 9 Skylight 1:Metal Frame with Thermal Break:Double Pane with 8 0.340 3 Low-E Ceiling 2:Flat Ceiling or Scissor Truss 1200 30.0 0.0 42 Wall 1:Wood Frame,16"o.c. 581 19.0 0.0 9 Window 1:Vinyl Frame:Double Pane with Low-E 170 0.340 58 Window 2:Vinyl Frame:Double Pane with Low-E 168 0.340 57 Door 1:Glass 80 0.340 27 Door 2:Solid 20 0.340 7 Wall 2:Wood Frame,16"o.c. 2400 19.0 0.0 144 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 327 25.0 0.0 12 Floor 2:All-Wood Joist/Truss:Over Unconditioned Space 1200 19.0 0.0 56 Furnace 1:Forced Hot Air95 AFUE The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems have been designed to meet the 2007 New York Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. Rx �; �; Project Title:KRAMAR RESIDENCE 4 SEASON ROOM G Page 1 of 4 Data filename:C:\Users\Allen\Desktop\Backup Files Folder\Business Files\HOUSE ADDITIONS,DECKS,3 SEASON ROOMS,ETC\3& 4 SEASON ROOMS\KRAMAR 4 SEASON ROOM\Kramar RESchedk.rck Report date: 11/11/08 REScheck Software Version 4.1.2 Inspection Checklist CNJ( Date: 11/11/08 Ceilings: ❑ Ceiling 1:Cathedral Ceiling(no attic),R-38.0 cavity insulation Comments: ❑ Ceiling 2:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments: Above-Grade Wails: ❑ Wall 1:Wood Frame,16"o.c.,R-19.0 cavity insulation Comments: ❑ Wall 2:Wood Frame,16"o.c.,R-19.0 cavity insulation Comments: Windows: ❑ Window 1:Vinyl Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 2:Vinyl Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: Wanes Frame Type Thermal Break? Yes No Comments: Skylights: ❑ Skylight 1:Metal Frame with Thermal Break:Double Pane with Low-E,U-factor:0.340 #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1:Glass,U-factor:0.340 Comments: ❑ Door 2:Solid,U-factor:0.340 Comments: Floors: ❑ Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-25.0 cavity insulation Comments: ❑ Floor 2:All-Wood Joist/Truss:Over Unconditioned Space,R-19.0 cavity insulation Comments: Heating and Cooling Equipment: ❑ Furnace 1:Forced Hot Air:95 AFUE or higher Make and Model Number: Project Title:KRAMAR RESIDENCE 4 SEASON ROOM Page 2 of 4 Data filename:C:\Users\Hllen\Desktop\Backup Files Folder\Business Files\HOUSE ADDITIONS,DECKS,3 SEASON ROOMS,ETC\3 8 4 SEASON ROOMS\KRAMAR 4 SEASON ROOM\Kramar REScheck.rck Report date:11/11/08 Lj Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed. Lj Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation. Vapor Retarder: Installed on the warmi4n-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: Lj Materials and equipment are installed in accordance with the manufacturer's installation instructions. Lj Materials and equipment are identified so that compliance can be determined. 0 Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. ❑ Insulation R-values,glazing U-factors,and heating equipment efficiency are clearly marked on the building plans or specifications. Q Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: Lj Supply ducts in unconditioned attics or outside the building are insulated to R-8. Li Return ducts in unconditioned attics or outside the building are insulated to R-4. Supply ducts in unconditioned spaces are insulated to R-8. Return ducts in unconditioned spaces(except basements)are insulated to R-2.Insulation is not required on return ducts in basements. Duct Construction: 0 All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric, or tapes.Tapes and mastics are rated UL 181 A or UL 181 B. Exceptions: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). Lj The HVAC system provides a means for balancing air and water systems. Temperature Controls: Lj Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: Lj Separate electric meters exist for each dwelling unit. Fireplaces: Ll Fireplaces are installed with tight fitting non-combustible fireplace doors. Fireplaces have a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: Ll Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: 0 Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: Lj All heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps have a time clock. Heating and Cooling Piping Insulation: 0 HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Project Title: KRAMAR RESIDENCE 4 SEASON ROOM Page 3 of 4 Data filename:C:\Users\Allen\Desktop\Backup Files Folder\Business Files\HOUSE ADDITIONS,DECKS,3 SEASON ROOMS,ETC13& 4 SEASON ROOMS\KRAMAR 4 SEASON ROOM\Kramar REScheck.rck Report date:11/11/08 r Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Temperature("F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2.Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range ff) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Project Title: KRAMAR RESIDENCE 4 SEASON ROOM Page 4 of 4 Data filename:C.\Users\Allen\Desktop\Backup Files Folder\Business Files\HOUSE ADDITIONS,DECKS,3 SEASON ROOMS,ETC\3& 4 SEASON ROOMS\KRAMAR 4 SEASON ROOM\Kramar REScheck.rck Report date: 11/11/08