ResCheckREScheck Software Version 4.7.0 Compliance Certificate_ Project New Residence Energy Code:2015 1ECC Location:Glens Fi Ir ;—— |)FEB 11 an ||)| +»New Y« Construction Type:Single-family Project Type:New Construction|FILE COPY Conditioned Floor Area:2,065 ft2 Glazing Area 20% Climate Zone:6 (7635 HDD) Permit Date: Permit Number: REvi D FOR ENERGY CODE COMPLIANCE Owner/Agent:Designer/Contractor: Kimberly Drive Dave Monsour Ethan HallQueensbury,NY 12804 Monsour Builders Rucinski Hall Architecture ‘Queensbury,NY 12804 134 Dix Ave Cae Renee Compliance:1.2%Better Than Code Maximum UA:338 Glens Falls,NY 12801 518-741-0268 ephall@nycap.rr.com Your UA:334 ‘The %Better or Worse Than Cede Index reflects how dose to compllance the house is based on code Wade-off es.TEDOES NOT prove an esunate of energy use or cos relaave tos mnimum-code home Envi Wall 1:Wood Frame,16"o.c. Window 1:VinylFiberglass Frame:Double Pane with Low-E Door 1:Solid Door 2:Solid Door 3:Glass Basement Wall 1:Solid Concrete or Masonry Wall height:7.9° Depth below grade:6.0° Insulation depth:7.5" Window 2:VinylFiberglass Frame:Double Pane with Low-E CC meceA101549.0 00 ©0020 20 2470 21.0 00 ©0057 111 a7 0290 121 40 0.30012 20 0300 6 40 032013 1,026 00©190 004343 2 02908 308.18-2-58.3 RC-0058-2020 Monsour Enterprises LLC 11 Kimberly Ln SFD w/gas FP 2034 s.f.,Gar.624 sf. Project Title:New Residence Data filename:Y:\Monsour -Colonial Model\Monsour -Colonis Report date:02/10/20 Model -Non-zip.rck Page 1 of10 Compliance Statement:The proposed building design described here is consistent with the building plans,specifications,and othercalculationssubmittedwiththepermitapplication.The proposed building has been designed to meet the 2015 IEC requirements in REScheck Version 4.7.0 and to comply with the mandatory "lan in,cher Inspection Checklist.Lat Plow Secarteer Name-Titie Project Title:New Residence Report date:02/10/20 Data filename:Y:\Monsour -Colonial Model\Monsour -Colonial Model -Non-zip.rck Page 2 of10 aj REScheck Software Version 4.7.0 Inspection Checklist Energy Code:2015 IECC Requirements:100.0%were addressed directly in the REScheck software Text in the "Comments/Assumptions"column is provided by the user in the REScheck Rea ments screen.For each requirement,the user certifies that a code requirement will be met and how that is documented,or that an exception is being claimed.Where compliance is itemized in a separate table,a reference to that table is provided. Section ie #|Pre-Inspection/Plan Review ]Hans Vedied |Field Veufied|complies?|Comments/Assumptions&Regi || 103.1,Construction drawings and Cicomplies Requirement will be met. 103.2°documentation demonstrate Coes Not(PRI ‘energy code compliance for the Location on plans/spec:A- a,(ace escce nara!Net observabie envelope represented on INot Applicable construction documents.ae di)103.1,Construction drawings and Ticomplies Requirement will be met. 1103.2,documentation demonstrate Coes Not 1403.7 energy code compliance for Location on plans/spec:A- (PR3}lighting and mechanical systems.DiNot Observable @ Systems serving multiple CiNot Applicable ‘dwelling units must demonstrate ‘compliance with the IECC |___Commercial Provisions,ae.B02)Heating and cooling equipment is Heating Heating:Cicomplies Requirement will be met.037 sized per ACCA Manual Sbased Btu Btu/hr,Does Not|[PR2?on loads calculated per ACCA in Location on plans/spec:A- Honuel}srctvermecoas|conlng Seating hot observable approved by the code official —_INot Applicable Additional Comments/Assumptions: 1 |High impact (Tier 1)|2 |Medium impact (Tier 2)[3 [Low impact Tier3)| Project Title:New Residence Data filename:Y:\Monsour -Colonial Mode\Monsour -Colonial Model -Non-zip.rck Report date:02/10/20 Page 3 of10 Dot Applicable $eaionF"|Foundation inspection a Verified|Field verified|Complies?|Comments/Assumptions&Req.iD a eee.@402.1.1 Conditioned basement wall Re Ocomplies ‘See the Envelope Assemblies [FO4}!insulation R-value.Where interior p.Re Bboes not table for values.Inston used.vericaton |—e may need to occur during INGE Obeatvabie! Insulation Inspection.Not not Applicablerutedwaterndlocations Inelmate Zone 3 .7"fe303.2 Conditioned basement wall complies Requirement will be met. (FOS?—_insulation installed per Oboes not ees anata ters se chen Cher oberae beatin on lansspec i Dot Applicable 402.2.9 Conditioned basement wall ft ft Ocomplies ‘See the Envelope Assemblies. (FO)!insulation depth of burial or =|—_does Not table forvalvesO_dctance hom tp of wal,ee eenotApplicable 1303.2.1 A protective covering is installed complies Exceptic \equirement is([FO11P to protect exposed exterior Oboes not not applicable.ecco and ears ;2 minimum of6in.below grade.(Not Observable i Dot Applicable 403.9 ‘Snow-and ice-melting system complies Requirement will be met.F012"controls installed,Oboes not°[Not Observable Additional Comments/Assumptions: 1 /High Impact Tier 1)|2 [Medium Impact (Tier2)|3 |Low impact (Tier 3)| Project Title:Ne Data filename: lew Residence ‘\Monsour -Colonial Model\Monsour -Colonial Model -Non-zip.rck Report date:02/10/20 Page 4 of10 Section T F F |Framing /Rough-In nepection|ans Verified |Fleld verified |Compties?|comments/AssumptionsRAGEaEE{sme Lay z 2 1402.1.1,Door U-actor.u Tcomplies See the Envelope Assemblesa02'3.4 Dbocenot ‘table forvatuesFRIraNotObservableNotApplicable }402.1.1,Glazing U-factor (area-weighted —_U-complies ‘See the Envelope Assemblies '402.3.1,average).Coes Not table forvalues. '402'3:3, ‘402.5 (Not ObservablereaCiNotApplicablee '303.1.3 Ufactors of fenestration products Cicomplies Requirement will be met. (FR4}are determined in accordance Odoes NotwiththeNFRCtestproced 1 he©With the NFRC test procedure or Wet Observable Leeation on plans/spec:A ee Dot Applicable '402.4.1.1 Air barter and thermal barrier complies Requirement will be met. {FR23}""installed per manufacturer's oes not @_instructions iNet Observable Leeation on plans/spec:A. ONot Applicable [402.43 Fenestration that isnot site bull complies Requirement will be met. [FR20P is listed and labeled as meeting Oboes Not (@__AAMA/WDMAICSA 101/5.2/A440 Ra ier aeorhasinfiltrationratesperNFRC 400 that do not exceed code Oot Applicable its. 1402.45 IC-rated recessed lighting fixtures,‘complies:Exception:Requirement is[FRI6}?—_sealed at housing/interior finish Coes Not not applicable. ‘and labeled to indicate =2.0 cfmeateraeTsPe Not Observableinenotapplicable [403.3.1 Supply and return ducts in attics ‘complies TFRIZ}.insulated>=R-8 where duct is Tdoes Not ——compiletely inside the @ =3inches in lameter and >=Caner Observable building envelope.6 where <3 inches.Supply and retum ducts in other portions of DNot Applicable the building insulated>=R6 for diameter >=3 inches and R-4.2, for <3 inches in diameter.‘1403.35 Building cavities are not used as Ticomplies Requirement will be met. [fFRISP ducts or plenums.Oboes Not.CiNot Observable Lecation on plans/spec:A- cea Aad Got Applicable [403.4 HVAC piping conveying fluids Requirement willbe met [FRI7P above 105 °F or chilled fluids o below 55 SF are insulated to 2R-Not Observable Be CNet Applicable '403.4.1 Protection of insulation on HVAC Ccomplies Requirement will be met. TFR24}piping.Oboes Not e (Not ObservableWotApplicable 1403.5,3_Hot water pipes are insulated to Ccomplies Exception:Requirement is(erie?=R-3,Cdoes Not —snot applicable.e (Not Observable 5 Cot Applicable 403.6 Automatic or gravity dampers are Ccomplies Requirement will be met. {FRI9P installed on all outdoor air Coes Notintakesandexhausts.ot Observable KREation on plans/spec:A Bot Appi [1 |High impact (Tier 1)[2)|Medium impact (Tier 2)|3 |Low impact Tier 3) Project Title:New Residence Report date:02/10/20 Data filename:Y:\Monsour -Colonial Model\Monsour -Colonial Model -Non-zip.rck Page 5 of10 Additional Comments/Assumptions: [11|High impact (Tier1)[2 Medium impact (Tier 2)|3 |Low Impact (Tier 3)| Project Title:New Residence Report date:02/10/20 Data filename:Y:\Monsour -Colonial Model\Monsour -Colonial Model -Non-zip.rck Page 6 of10 Beer Plans Verified Field Verified ‘Comments/Assumptions ‘See the Envelope Assemblies Additional Comments/Assumptions: 1 High Impact (Tier 1)_|2 [Medium Impact (Tier 2) Project Title:New Residence Data filename:‘\Monsour -Colonial Model\Monsour -Colonial Model -Non-zi *Insulation Inspection complhaeveeValueoe -303.1 All installed insulation is labeled complies Requirement[IN13P or the installed R-values Codoes Not @ proses:(Not Observable Lane,Dot Applicable 402.1.1,Wall insulation R-value.f this is aR Re complies 40225,mass wall wih at least of the Cy Wood (1 Weoa does Not {able for values. 8°wall insulation on the wal Ei Mass Li Mass enerorenatIN3)>exterior,the exterior insulation lot Observable °requirement applies (FR10).CO Steet UO Steet ot Applicable 303.2 Wall insulation is installed per Cicomplies Requirement{IN}:manufacturer's instructions.Does Not Not Observable GiNot Applicable be met. Location on plans/spec:A- [3 [Low impact Ter 3) ck Report date:02/10/20 Page 7 of 10 1|High Impact (Tier 1)[|Medium Impact Tier 2) Section z ]aTF”|Final inspection Provisions|Plans Verified |Field veritied |Comptes?|Comments/AssumptionsRegi|eS ae |ora}402.1.1,Ceiling insulation R-value.R-Re complies ‘See the Envelope Assemblies. 4022.2 (0 Wood 1 Wood Cdoes Not ——_—able for values. 4022-2 Ci Steel O Steet Not Observable tear Not Applicable '303.1.1.1,Ceiling insulation installed per BUET Cicomplies Requirement will be met. 303.2”manufacturer's instructions Ciees Not[FI2"Blown insulation marked every iNet Observable Leeation on plans/spec:A.300 ft’..a”1 ia ae]Dot applicable 402.23.Vented attics with air permeable complies Exception:Requirement is[ri22¥"insulation include bate adacent Coes Not ——_not applicable.to soffit and eave vents that extends over insulation.(QNot Observable Location on plan:st AnCotApplicable{°°ee4022.4 Altic access hatch and door complies Requirement willbe met. [FI3}""insulation =R-value of the Oboes Notadjacentassembly.Caner observable beeation on plans/spec:A. _Not Applicable &'402.4.1.2 Blower door test @ 50 Pa.<=5 complies Requirement will be met. F117}:”ach in Climate Zones 1-2,and Coes Not<=3 ach in Climate Zones 3-8.inet Observabie Leeation on plans/spee:A 1 fi=eis|eeu Dot Applicable 403.34—Duct tightness test result of <=eim7i00 cfm/i00—CiComplies Exception:All ductsandair [FI4}!—_cfm/100 2 across the system or|FE ®Ddoes not handlers are located within ‘<=3 cfm/100 f2 without air not Observable “2nultioned space.handler @ 25 Pa.For rough-in oe VReas tests,verification may need to ot Applicable |_____occurduringFramingInspection.thee[403.3.3 Ducts are pressure tested to fm100 cfm/i00—Cicomplies [FI27F determine air leakage with ®®Cboes Not.handlers are located within either:Rough-in test:Total conditioned space.leakage measured with a ane Cbpervable, pressure differential of 0.1 inch INot Applicable Wg,across the system includingthemanufacturer’air handler enclosure if installed at time of test.Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch Wg.across the entire system including the manufacturer's air handler enclosure.shes4033.21 Air handler leakage designated complies Requirement will be met. [Fl24}*"by manufacturer at <=2%of Does Not }design airflow.Not Observable ech lis Foot Anpicaie!1s/403.2 Programmable thermostats Ocomplies Requirement will be met.(rai?stated for contra of primary Coes Not 4heatingandcoolingsystemsandLocationonplans/spec:A- initially set by manufacturer to |Not Observable code specifications Oot Applicable 1403.12 Heat pump thermostat installed complies Exception:Requirementis_|[FHO}?on heat pumps.Coes Not not applicable | |Not Observable »Not Applicable | 1403.51 Circulating service hot water complies {FILIP systems have automatic or Oboes Not not applicable.accessible manual control aia eaea8NotApplicable [3 |Low impact (Tier 3)| Project Title:New Residence Data filename:Y:\Monsour -Color |Model\Monsour -Colonial Model -Non-zip.rck Report date:02/10/20 Page 8 of10 Comments/Assumptions Requirement will be met. Location on plans/spec:A- Exception:Requirement isnotapplicable. Exception:Requirement isnotapplicable. ‘Exception:Requirement is ‘not applicable. ‘Exception:Requirement is not applicable. Requirement will be met. Location on plans/spec:A- Section Plans Verified|Field Verified a '403.6.1 Allmechanical ventilation system — Gcompties [F125}*fans not part of tested and listed Oboes NoteSeareneeotobservable oe __Binot Applicable 1403.2 Hot water boilers supplying heat complies[F126 through one-or two-pipe heating Does Notrirltomerboerwater"CNet Observable ‘temperature based on outdoor Oot Applicable temperature. 1403.51 Heated water circulation systems Ticomplies [FI28}*"have a circulation pump.The does Notsystemreturnpipeisadedicated return pipe or a cold water supply hist Observable pipe.Gravity and thermos-Onot Applicable syphon circulation systems areotpresent.Controls for circulating hot water system pumps start the pump with signalforhotwaterdemandwithinthe ‘occupancy.Controls automatically turn off the pump‘when water isin circulation loop is at set-point temperature and no demand for hot water exists [403.5.1.2 Electric heat trace systems Ccomplies (FI29%"comply with IEEE 515.1 or UL Cdoes Not 515.Controls automatically ‘adjust the energy input to the pele Obeervable heat tracing to maintain the Not Applicable desired water temperature in the rom See tek aie4035.2 Water distribution systems that Ccomplies [FI30}2 have recirculation pumps that Does Not pump water from a heated water supply pipe back to the heated Pele neatwatersourcethroughacoldCNotAppricable water supply pipe have a ‘demand recirculation water system.Pumps have controlsthatmanageoperationofthe pump and limit the temperature ofthe water entering the cold water piping to 104% 403.5.4 Drain water heat recovery units complies {F131}?tested in accordance with CSA Coes Not55.1.Potable water-side pressure loss of drain water heat {Not Observable recovery units <3 psi for Oot Applicable individual units connected to one or two showers.Potable water- side pressure loss of drain water heat recovery units <2 psi for individual units connected to|____three or more showers.=|404.1 75%of lamps in permanent complies [Fi6}*fixtures or 75%of permanent oes Notfixtureshavehighefficacylamps. Does not apply to low-voltage [EINOt Obsetvable fighting.Bot Applicable 1404.1.Fuel gas lighting systems have complies [FI23}?no continuous pilot light.Does Not @ Not observable 1 High Impact (Tier 1)|2 [Medium impact (Tier 2) Not Applicable [3 [Low impact (Tier 3) Requirement will be met. Location on plans/spec:A- Requirement will be met. Project Title:New Residence Data filename:‘\Monsour -Colonial Model\Monsour -Colonial Model -Non-zip.rck Report date:02/10/20 Page 9 of 10 :[Beetiony z 5PlansVerified|Field Verified a faialanie*ie Final Inspection Provisions valle Value Complies?|Comments/Assumptions: 1401.3 Compliance certificate posted IComplies Requirement will be met.lev?Cdoes not [Not ObservableDntApplicable Manufacturer manuals for complies Requirement will be met.mechanical and water heating ‘Dees Notsystemshavebeenprovided.Scent |Dot Applicable Additional Comments/Assumptions: [[High impact cTier)_[2)|Medium impact Tier 2)['3\JLow impact Tier 3)| Project Title:New Residence Data filename:Y:\Monsour -Colonial Model\Monsour -Colonial Model -Non-zip.rck Report date:02/10/20 Page 10 of10 2015 IECC Energy Efficiency Certificate a)R ‘Above-Grade Wal Below-Grade Wall 19.00 Floor 0.00 Ceiling /Roof 49.00 Ductwork (unconditioned spaces):eee csWindow0,29 Door 0.32Ceeered Heating System: Cooling Syster