Loading...
blower door results--22Testing Company: Name:LoCascio Energy Solutions Address:20 Ogden Rd. Queensbury , NEW YORK 12804 Phone: 5188573144 Technician: Name:Anthony LoCascio Credentials:HERS Rater#4242961 Email:tony@locascioenergysolutions.com Building Information: Project ID:22 wedge Address:22 Wedgewood-C Queensbury, NY 12804 Geo-Tag Data:Latitude: 43.326156 Longitude: -73.685027 Timestamp: 2020-02-12 12:41:11 Customer Information: Name:Schermerhorn Address:536 Bay Rd Queensbury, NY 12804 Measured Leakage:776.4 CFM50 Test ID:22 Wedgwood Purpose of Test:RESNET Multi-Pt Env. Leakage Measured ACH50:4.60 (+/- 5.1%)Effective Leakage Area: 35.1 in² Building Volume:10,127.0 ft³Enclosure Surface Area: 1,066.0 ft² Flow Coefficient (C):45.1 (+/- 24.9%)Exponent (n): 0.727 (+/- 0.071) Correlation Coefficient:0.99857 Test Standard:RESNET 380 Multi-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 66 °F Altitude: 424.0 ft Outdoor Temp: 32 °F Time Average Period: 10 seconds Test Date and Time:2020-02-12 14:47:55 Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -3.1 -60.0 -61.8 -58.8 -243.9 924.2 Ring B -48.0 -52.4 -49.3 -190.9 818.7 Ring B -35.0 -37.7 -34.7 -119.4 648.7 Ring B -23.0 -26.0 -22.9 -67.4 488.6 Ring B -10.0 -16.3 -13.2 -26.7 308.9 Ring B Test Equipment: Flow Device:Model 3 110V Fan Serial #: 3172 Pressure Gauge:DG1000 Serial #: 3172 Calibration Date: 2019-02-18 Deviations from Standard: None Comments: Envelope Leakage Test (Page 2) Report generated by TEC Auto Test version 1.6.3 (2), © 2019 by The Energy Conservatory, Inc.