2008-634 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE (3AF OCCUPANCY Permit Number. P20080634 Date Issued: Tuesday, January 12, 2010 This is to certify that work requested to be done as shown by Permit Number P20080634 has been completed. Location: 39 BRICKOVEN Rd Tax Map Number. 523400-308-018-0001-089-000-0000 Owner. WILLIAM & LESSLE GREEN Applicant: WILLIAM & LESSLE GREEN This structure may be occupied as a: Residential Addition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20080634 Application Number. A20080634 Tax Map No: 523400-308-018-0001-089-000-0000 Permission is hereby granted to: WILLIAM&LESSLE GREEN For property located at: 39 BRICKOVEN Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: WILLIAM &LESSLE GREEN 39 BRICKOVEN Rd Residential Addition $48,000.00 QUEENSBURY,NY 12804 Total value $48,000.00 Contractor or Builders Name/Address Electrical Inspection Agency Plans &Specifications 2008-634 600 SQ FT RESIDENTIAL ADDITION $75.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Tuesday, December 08, 2009 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury, Monday,December 08,2008 SIGNED BY jf for the Town of Queensbury. ct r veBu g nforcement Commuliitu Development Office Town of Queensburi/ • 742 Bay Rd. � Queensburir, Nero York •12804 PLOT PLAN } Show all existing and proposed structures. Indicate the setbacks of all structures and buildings froggy all properly lines. SIDE PROPERTY LINE QPoo.1. + _ -n w Ex,z ga•xe � ") Z } I— o� 0 w � _ � _ 70 n s � �..... f .. �.�.. ..... m w f` - -, : .... . .; ue .. SIDE PROPERTY LINE 3g �i�►�ove� ��, 1 SQUARE _ _FT. Vire!Warshal's Office Otwensj,it r1l - 74) 13'r y N oauf - New Ycrk -12804 .1 Ilalincr,, Fire Nf(Irslial C;an/ Sfrihmm, F)ejmf,i? [irc Marshal ^S? APPLICATION FOR FUEL BURN17VG APPLIANCE & CHIMNEYS Application is hereby made to the Building &Codes Office for the issuance of a Building & Use Permit pursuant to the New York State Fire Prevention & Building Code. The applicant or owner agrees to comply with all applicable laws, ordinances,regulations, and all conditions that are part of these requirements and also will allow all inspectors to enter premises to perform required inspections. IMPORTANT NOTE TO APPLICANT: ROUGH-IN AND FINAL INSPECTIONS ARE REQUIRED. OWNER: Les/1'r INSTALLER/BUILDER: r4 NO 7P ADDRESS: L IG VlYrAoi ADDRESS: '32- ffil-v L./V kf PHONE NOS. PHONE NOS. 7M 112 36� ST 2 LOCATION OF PROPERTY: 54ri r SUBDIVISION NAME: 'GP AR ul>se LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: 6-A) C, PHONE: ✓ FUEL BURNING APPLIANCE WOOD COAL PELLET GAS OIL INFORMATION STOVE FIREPLACE INSERT FIREPLACE,FACTORY BUILT* FIREPLACE,MASONRY FURNACE(GARAGE ONLY) I *IF FACTORY BUILT,PLEASE PROVIDE: MANUFACTURER NAME: 4 610 MODEL NO.D i/ LISTED BY: NUMBER: QUESTIONS? CALL 7614Z05 or 761-8206 CHIMNEY INFORMATION BLOCK BRICK STONE OR EMAIL: firemarshal@gueensbury.ne MASONRY" CHECK ONE V1 VISIT OUR WEBSITE SIZE IN FOR MORE INFORMATION TILE STEEL INCHES wwwgueensbury.ne FLUE CHECK ONE ✓ DOUBLE CHIMNEY TRIPLE WALL INSULATED DIRECT VENT WALL LINER CHIMNEY MATERIAL cHEcKONE **IF NON-MASONRY,PLEASE PROVIDE: MANUFACTURER NAME: MODEL NO. ADDITIONAL NOTE: CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION&BUILDING CODE AND/OR MANUFACTURERS REQUIREMENTS. CONSULT AVAILABLE TOWN Of QUEEN3BURY HANDOUTS REGARDING REQUIRED INSPECTIONS. .............. ...... OFFICE USE ONLY ...............,.� � 0 TAX MAP NO. PERMIT NO. NOV 1006 , 10 FEES: PERMIT SIRECREATION ENGINEERING (If applicable)-------------------------------------------------------------------------- ; PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: (. //Opll Cew,- -ftve. OWNER: 1 s�i (g,gpoo ADDRESS: _3 (:�hlIrt�° � ADDRESS: ARI Opp/t1 PHONE NOS. " V /lam -2151- S az PHONE NOS. CONTACT PERSON FOR BUILDING &CODES COMPLIANCE: �i�n) PHONE: �_f �� LOCATION OF PROPERTY: 3`t 121zf ck OYPn/ KQp' HAS THERE BEEN A SITE PLAN REVIEW; VARIANCE 0 UBDIVISIO AN PPRC ? 92" R(1,� ILA YES ❑ NO IF SO, INDICATE APPLICATION NO. AND DATE OF APPROVAL: eeo/�' �'S e I I PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT APPLY TO YOUR Z F- LL p O W � cn I PROJECT 00 O O = _ LLu- W`W = Fa-- OL9z 0 z °a a � a Na oU � U airs I SINGLE FAMILY 60v r i Y` TWO-FAMILY MULTI-FAMILY (NO. of UNITS ) i TOWNHOUSE i BUSINESS OFFICE i RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) i OTHER IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST: q, L FUEL TYPE: CAA S HEAT TYPE: /Lr At "HOW MANY FIREPLACE(S): AND/OR WOODSTOVES(S): ZONING CATEGORY: 1 ARE THERE WETLANDS ON THIS SITE? /VD IS THIS A HISTORIC SITE? A)O PROPOSED USE OF BUILDING OR ADDITION: I *Please complete a separate Application for"Fuel Burning Appliances&Chimneys" available in our office i Town of Queensbury • Conimunity Development Office • 742 Bay Road, Queensbury, NY 12804 Queensb ry Building & Code Enforcement - Residential Final Inspection Office No. (518) 761-8256 Arrive: .-Z a am/pm Date Inspection request received: Inspector's Initials: NAME: P MIT#: L -G3 LOCATION: ATE: TYPE OF STRUCTURE"--' Comments: Yee N A ,C Building Number Address visible from road le>r 12-- y-07 . Chimney Height/W Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors _ Handrail 4 or more risers Guards at stairs deckspatios more than 30 inches above reds Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bra /Handicapp2d Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plo Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety-glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic aocess 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access 1 N.ft-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation l Insulation Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief VaIve(sj installed i Heat Ira Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W G um Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Dud work Sealed properly Gas Logo in Sealed or Glass Enclosure Final Electrical Final Surve Piot Plan Are Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built§2gic System/Sewer De . Ins ion Sticker Site Plan /Variance reguired Flood Plain Certification,if re uired Okay to issue C I C or C/®1 Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection FormsWesidential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised BM08 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: m Date Inspection re st received _� Inspector's Initials: / !/ NAME: (L /1— �o� PE IT#: LOCATION: DATE: TYPE OF STRUCTURE: Comments: Yes No NIA 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches To Roof Complete/Exterior Finish Complete Platform at all exterior doors TL 5wi 1,kM yJ6 Handrail 4 or more risers Guards at stairs deckspatios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/re ulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safet y glazing/Wirtdow in stairwells salety.91azing Interior Smoke ectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom me: Inter Connected: Bette backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation I Insulation Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency Tess below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Tra /Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'/"Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Gara92 fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built S is S stem/Sewer De t. Ins coon Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C 10 1 Temporary/Permanent LABuilding&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008; Revised 6/26/08 F, e Tm m of Queemrbory Mme Manhal 742 Bay Road Qmeambury,NY in" 761�/7i1-8296 fax 7454437 Factory BuMt Gas F vWace/Stove Inspection Report Nebo New Ywk Stale mgoh s that an UL Lided,factory bum Wlimom be W a/ed ama ding to the ioatructimns and opecd'icatia�s eon io the mom Mammal the appiame.No deviation from the iadhactioos or is allowed. # vu' 3 sa�red�e Iaepection r s 5 Tile -r u A�'a. pm amythe w t4=w r-- �r� Addmna I Zr C.�G�-P�—C Bom o to_„ App4anoe Mamhdahclmrtr Mods d Duct vent F'aclory Built Chimoey Me Size Double Wan Triple Wan hu mlabed Yes No N/A Commuca s Floor Protection V/ Clearances to Combustibles(a8 sides) Fbwtop(s) vft*c d Ctiane Wan Pe ockma n,� Vent Clearances to Combustibles Vent/Chimney Termination Chommey behdht mod be 3 feet above red pemeb*ioo;2 feet above my combombible moo widds 10 feet Gas Shut-Off Valve V/ Combustion Air f Hearth Extension(d any) Mantel Udglit above Up Witness Operation 77 Tank Placement(if LP) Yebw PMk-lm h&wA l Foundation Inspection Rep Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart-eZLd((JJm/pm 742 Bay Rd.,Queensbury,NY 12804 inspector's Initials: _r� , NAME:` PERMIT#: LOCATION: -2 al 1ZL' 42,lel INSPECT ON: 444 TYPE OF STRU Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placementof the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place \�v y Footing Dowels or Keyway in place ( } \\ VV Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Framing / Firestopping Inspectio Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 inspector's Initials: - � NAME: PERMIT LOCATION: V e INSPECT ON: TYPE OF STRUCTURE:" Y N NIA COMMENTS: Framing ccess 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jadc Posts/Main Beams Exterior sheeting nailed properly �-- 12" O.C. WAVA- Headroom 6 ft. 8 in. Stairwells 36 in. or more �! Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side's inch or 5/8 inch Type X Garage side 5/8 inch Type X CeilingNmll Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LABuiiding&Codes For ns-=Building&CodesNinspedion FomhsTranmp fteolopping Inspection RepoR.doe Revised January 7,2008 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Ins action req s re ed: Queensbury Building & Code Enforcement Arrive: art: -aRW-- 742 Bay Road, Queensbury, NY 12804 Inspector's Initial : NAME:_ C-- — PER #: �, --(G`�i-� LOCATION: ?,�� �<< �,� ��.� INSPECT ON: TYPE OF STRUCTURE: Y N NIA Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Reportrevised Nov 17 2003, revised February 15,2005, revised January 7,2008 Rough Plumbing I Insulation Inspection tiipo- rt Office No. (518) 761-8256 Date In e n re ue ceiv Queensbury Building & Code Enforcement Arrive: = m1 �. `� 742 Bay Road, Queensbury, NY 12804 Inspect is Initia s: NAME: P ` PER M LOCATION: �' `' C �__ INSPECT ON: -- TYPE OF STRUCTURE: Y N NIA Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent �- Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping , Air/Head 50 P.S.1 for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door!Window Sealed No Insulation Duct 1 Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing insulation Report,revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date In nest received: Queensbury Building &Code Enforcement Arrive: L -' Depart: drrVpm 742 Bay Road, Queensbury, NY 12804 Inspe is initials: NAME: �4, 'HERMIT LOCATION: ,-`' INSPECT ON: TYPE OF ST Y N N/A COMMENTS: Fra - Attic Access 22" x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Wails Metal Strapping for Notches Top Plate 1 'h w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 518 inch Type X Ceilingfwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. W 5.7 sf above/below grade 5.0 sf grade LABuilding&Codes Forms-OLDrBuilci ft&CodesUnspection FwmsTreming Fuestopping Inspection ReporLdoc Revised January 7,2008 Timm of Qaoemdmn7 Mtge Marshal 4E) 742 Say Road Queeedn",NY 12M 761-8205/761-8266 fax 7454437 Factory Belt Gas Firealace/Stove Ins Notion New Ysnic State mqmm that all IDL Listed,kcb"built apomwes be iada8ed aocording to the and apecMcalisas in the lostanades Masoad aocosspanying tie app8amr-No deviation frost the ssaas�attr�+er's iMnctiows or specificatim is Am ies' (� p�ntt# j a Schedule iapaCho n ' is rl 15e =aoi pan and a Address kpph-aaoe act rer t/-7 Mudd# 6 r2 07N J\i CY3-`I Cpi,i Dir+ecx Vent Irad6ory B4a7t Chiesney Me size Doable Wa8 Triple Walt Is<srdated rYes, No MA Cortmts afloor Protection Clearances to Combustibles(all sides) Ii irestop(s) Vertical Cbase Wet haetratim Vent Clearances to Combustibles Vent/Chimney Termination Chimney bei0it mood be 3 feet above roof penetration;2 fed above any cowbnstible oomsbuction Wid"18 fed Gas Shut-Off Valve Combustion Air Hearth Extension(if any) Mantel UdgM above Up Witness Operation Tamp Placement Cif t8) W&Jk-8WVMWg Dept Yenos Pick-[doeM=*d 1y_�� Framing I Firestopping Inspection Report Office No. (518)761-8256 Date Ins n ved: Queensbury Building &Code Enforcement Arrive: a part: m 742 Bay Road, Queensbury, NY 12804 Inspector's tnttials NAME: (1 �LRMIT#:LOCATION: INSPECT ON: ZI; PE OF STRUCTURE: Y N WA Framing COMMENTS: — Attic Access 22" x 30" minimum `��_ Jack Studs/Headers -OJT TO C X-� iw( Bracing/Bridging Jj %VAL Joist hangers ✓, Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. J Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Botts 6 ft. or less on center Ice and water shield 24 inches from wall re separation 1, 2, 3 hour Fire wall, 3, 4 hour enetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASuilding&Codes Fortes-OL13113uilding&CodesYnspection Fonnewraming FnetopPmD inspection Report.doc Revised January 7,20M Framing / Firestopping Inspecti Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: aff Yom Depart:ng�am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: _ NAME: PERMIT#: c LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N WA COMMENTS: Framing cress 22" x 30" minimumce ,°' 1-- r ^ Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D rmus each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 518 inch Type X Ceilingfwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (M 5.7 sf above/below grade 5.0 sf grade L:1Buiidhg&Codes Fomts4)LD16uUding&CodesVnspection Fomnswraming Firestopping Inspection ReporLdoc Revised January 7,2008 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection est ce ed: Queensbury Building&Code Enforcement Arrive: a part: a 742 Bay Road, Queensbury, NY 12804 Inspector's Ink' NAME: PERMIT#: LOCATION: ! INSPECT ON: TYPE OF STRUCTURE: Framing Y N NIA COMMENTS: ccess 22" x 30" minimum Jack Studs/Headers Bracing Aft Joist hangers ✓ Jack Posts/Main Beams Exterior sheeting nailed properly ,/, -A 12"O.C. ELT Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate - 1 '/ w 16 gauge 8 16D naiis each side -- ;- Draft stopping 1,000 sq. ft. floor trusses Anchor Botts 6 ft. or less on enter Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceilingtwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:1BuildW*&Codes Forms-01MOuildirg&CodesYnspection FormsTrarnkV Firestopping Inspection ReporLdoc Revised January 7,2006 Framing I Firestopping Inspection Repo rt Office No. (518) 761-8256 Date ins cfion i 7 6'� Queensbury Building &Code Enforcement Arrive. it: 742 Bay Road, Queensbury, NY 12804 Inspector's initia NAME: ` r ERMIT LOCATION: INSPECT ON: TYPE OF STRUCTURE:Framing �---- Y N NIA COMMENTS: Attic Access 220 x 30' minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jadc Posts/Main Beams Exterior sheeting nailed properly 12° O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nits each side Draft stopping 1,000 sq. ft. floor trusses An ft. or less on center Ice and water sh• 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in Cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 518 inch Type X Ceilingtwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LABUilding&Codes Forms-01.0ftildit&CodesNnspedion FoffneT sming Fu piny Inspection Repoit.doc Revised January 7,2008 Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initial t NAME: PERMIT#: LOCATION: r,fe- i v ._ INSPECT ON: TYPE OF STRU TtJRE: Commgnts Y N N/A Footings Piers � do,— Monolithic Slab Reinforcement in Place The contractor is responsible for or awfmft providing protection from freezing for 48 hours following the placement of the concrete. ».. Materials for this purpose on site. �'�C"hl*j Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: width inch�e�bove footing 6 milfor wet areas under slab Backfill Ap phoval g Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM 0Z2 o©) F-10 � ne S Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials ! NAME: (/r� PERMIT#: LOCATION: 1 INSPECT ON: 2 - 3T22Y , TYPE OF STRUCTURE: Commenta Y N1A Footin Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Y�.r Foundation Dampproofing Foundation waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LABuilding&Codes FormsWuilding&Codes\Inspecbon Forms\Foundabon Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Les /IY 6a��>v i 39 36 '' ? �, Ink tA, spa(Rs 6,esPmvr1t M ►,vImUon i p'19 SQL �A, or s �eti u��e G-x�"eti�o�. eR its �L - aAlo sPV" a o/Zd�7fn 1). ga)2 11PASPR thee. s7 3 Ply V�- g y STee-f geA w �yx 3a `3'' Q�dve i TOWN OF QUEENSBURY BUILDING DEPARTMENT Based on our limited examination, l, compliance with our comments shall not be construed as indicating the plans and specifications are in full compliance with the-Building Codes of New York State. NOTICE '(RAFT!'AM3 ATtON MUST BE COVERED ByNW-MM8WIBLE BARRIER NOTICE FOAM 'NStJLMN M W BE COVERED BY A 15 MINUTE THERMAL, BARRIER i 37 l(e tr o ,(IglJ oy r' --- so Le F f e Le vr-t ors jf a � fit /i dt' od ol did -Al th S ` )x-' t tt LA d7 Er l! r a'1!i SII�� f � $ AJh�� J 5f"o da/� N�av9 a'I spy ss()71� Community Development Office uwn of Queensbury - 742 Bay Road - Quecttsburi�, Nero York •12804 U''14 ; _- BUILDING PERMIT CALCULATION SHEET: NATURAL LIGHT, VENTILATION AND EMERGENCY EGRESS REQUIREMENTS REWIRED ACTUAL LIGHT REQUIRED AGTUAL SQUARE FOOT HABITABLE ROOM AREA OF ROOM IN LIGHT VENTILATION SQUARE FEET 8%OF ROOM SQUARE V F ROOM AREA SQUARE OPENING FOR REMARKS AREA FOOTAGE OF ROOM AREA FOOTAGE EGRESS 4 QUESTIONS 7 CALL 761-8256 OR EMAIL codes( Queensbury.net VISIT OUR WEBSITE FOR MORE INFORMATION '` %/ www.guensbury.net �I ���rG4 B 10-LTR I1-20 ----------------- 5 Community Development Office own of Queensbury • 742 Bay Road • Queensbury, New York -12804 ; WINDOW SCHEDULE -__________________ ' JOB SITE/ADDRESS: r. �e �peN �r ft)) k6jftf 0, DATE: OWNER: APPLICATION NO.: WINDOW CLEAR UNIT OR CLEAR WINDOW STOCK ROUGH ROUGH SQ.FT. OPENING NO.OR WINDOW SQ.FT. WIDTH OPENING SPECIAL HARDWARE OR MANUFACTURER NUMBER OPENING OPENING EGRESS/CLEAR HEIGHT LETTER NAME MODEL/TYPE CALL WIDTH HEIGHT VENT OPENING S IN INSTRUCTIONS ON PLAN SIZE INCHES INCHES D �{ 3o 3�l '9 v S 5 3��� 416 7 n :� B 26-LTR 11-05 i I� \ /o\ f W� ►ao��r-y �I f Vh �y o�en►� R �I 9 i 3as6 3o56 30% 10 S\j F(oo 3 Act C�k 0 V e N � PIA r 3 i tt otf Oil It o �. 1 Sty a Aij 1 a ts� 1 t u �- { i d I-) Gi C:p Q-- a r �rS ` Ic r cr- c' M f REScheck Software Version 4.1.0 Compliance Certificate Project Title: Leslie Green Living Room Addition Report Date: 11/25/08 Data filename:C:\Documents and Settings\Lynn&Judd\My Documents\JmLeslieGreen.rck Energy Code: New York State Energy Conservation Construction Code Location: Warren County,New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 18% Heating Degree Days: 7635 Construction Site: Owner/Agent: Designer/Contractor: 39 Brickoven Road Leslie Green Ken Collette Queensbury,,NY 12801 39 Brickoven Road 39 Collette Lane Queensbury,NY Hudson Falls,NY 12839 'Compliance: Maximum UA: 135 Your Home UA:113=16.3%Better Than Code Gross Cavity Cont. Glazing UA Assembly Area or R-Value R-Value or D.. Perimeter U-Factor Ceiling 1:Cathedral Ceiling(no attic) 720 38.0 0.0 19 Wall 1:Wood Frame,16"o.c. 160 21.0 0.0 6 Window 1:Wood Frame:Double Pane with Low-E 17 0.330 6 Window 2:Vinyl Frame:Double Pane with Low-E 17 0.330 6 Window 3:Wood Frame:Double Pane with Low-E 17 0.330 6 Wall 2:Wood Frame,16'o.c. 390 21.0 0.0 22 Wall 3:Wood Frame,16"o.c. 164 21.0 0.0 4 Window 4:Wood Frame:Double Pane with Low-E 41 0.330 14 Door 1:Glass 41 0.330 14 Door 2:Solid 20 0.300 6 Wall 4:Wood Frame,16"o.c. 100 21.0 0.0 5 Window 5:Wood Frame:Double Pane with Low-E 14 0.330 5 Furnace 1:Forced Hot Air93 AFUE The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. Ke.,) GSilP r1,I- . PAPS --eos- Name-Title Signature Date 0; I -✓ X Leslie Green Living Room Addition Page 1 of 4