Loading...
2008-642 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20080642 Date Issued: Wednesday, January 13, 2010 This is to certify that work requested to be done as shown by Permit Number P20080642 has been completed. Location: GENEVA Dr Tax Map Number. 523400-301-020-0001-011-000-0000 Owner. CLUTE ENTERPRISES Applicant: CLUTE ENTERPRISES This structure maybe occupied as a: Garage Attached By Order of Town Board Single Family Dwelling TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the ` fj property owner of the responsibility for compliance with Site Plan, ,� v ° Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20080642 Application Number. A20080642 Tax Map No: 523400-3 01-020-0001-011-000-0000 Permission is hereby granted to: CLUTE ENTERPRISES For property located at: GENEVA Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: CLUTE ENTERPRISES 13 DAWN Rd Garage Attached QUEENSBURY,NY 12804-0000 Single Family Dwelling $125,000.00 Total Value $125,000.00 Contractor or Builder's Name/ Address Electrical Inspection Agency Plans &Specifications 2008-642 1300 sq ft single family dwelling&400 sq ft garage $196.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Wednesday, December 16, 2009 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T o eetxty7 ' Au , ecember 16, 2008 >:r SIGNED BY ° �" for the Town of Queensbury. Director of Building&Code Enforcement `rrrrrrrrrrrwrrrrrwrrrrwwrrrwrwrrrww.rrw.r.wwr.w,wrrrrrr.r:rrwwwwrr,r. rrwwrwr rrrwrwrww,wwr� rw ' OFFICE USE ONLY i `? i 1 0, TAX MAP NO PERMIT NO. ,` °} _ ERMIT FEE ; ', DEC ; APPROVALS: ZONING TOWN CLERK_ ; ' 200e :_wrwwwwww_ww_wwww_wwrwrw_rwr__wwwwrrrwr,_r__r,r_wrr wrw,w,rr_,r__- ----------- APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMITI A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. - OWNER: \��P INSTALLER: ADDRESS: ADDRESS: Noe- c�&n y PHONE NOS. PHONE NOS. 779 1, Z-->-7- J LOCATION OF INSTALLATION: r- ...........................3.........................................................;...........•.............................................................. .................................................................................... RESIDENCE INFORMATION: YEAR BUILT BEDROOMS X I COMPUTATION- ': _ TOTAL DAILY FLOW .............................................................................................;.........................................................................:....... ; ..... ; .......•....•.....................................................• GARBAGE GRINDEa j 1980 or older ; ! X 150 gallon per bedroom = i INSTALLED? ......................._.......................y..........................•................... ...........................................1...........,.......................................................................... i 198i -1991 i X 1 130 gallon per bedroom _ `•• ¢................................I............... i 1992-present ( > X j 110 gallon per bedroom 3 INSTALLED t............................•.•.................................... .......................•..........;.........................................................................;...........................................•....,.................................... ?— - PARCEL INFORMATION: ✓ TOPOGRAPHY: FLAT ROLLING K STEEP SLOPE %SLOPE ✓ SOIL NATURE: SAND LOAM CLAY OTHER ✓ GROUNDWATER: AT WHAT DEPTH? BEDROCMMPERVIOUS MATERIAL: AT WHAT DEPTH? ✓ DOMESTIC WATER SUPLY: MUNICIPAL/ WELL (IF WELL:WATER SUPPLY FROM ANY SEPTIC-SYSTEM ABSORPTION IS ____FT._) ✓ PERCOLATION TEST: RATE IS PER MIINUTE PER INCH (TEST TO BE COMPLETED BY A LICENSED PROFESSIONAL ENGINEER OR ARCHITECT) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect (unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each garbage grinder, spa or whirlpool tub. ✓ SEPTIC TANK: GALLON (MIN. SIZE IS 1,000 GAL.) TILE FIELD: EACH TRENCH � FT. ✓ TOTAL SYSTEM LENGTH: - oo _FT. SEEPAGE PIT(S): HOW MANY? ✓ SIZE OF EACH FT. X FT. ✓ SIZE OF STONE TO BE USED: # 1 DEPTH OR THICKNESS FT. ✓ BED SYSTEM SIZE: X ✓ ALTERNATIVE SYSTEM: LENGTH AND/OR SIZE ✓ HOLDING TANK SYSTEM:(If required) NO. OF TANKS: /SIZE OF EACH ✓ GALLONS. /TOTAL CAPACITY: GAL. NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN I; is ii APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void: I have read the r ns with respect to this application and agree to at) by thes and a ents of the Town of QUESTIONS? CALL 761.8256 OR EMAIL Queens ry Sanitar a ge posal Ordinance. cQaes�aueensburv.net VISIT OUR WESSITE FOR MORE INFORMATION i www.gueensburv.net nature of Person Responsible Date Town of Queensbury - Community Development Office - 742 Bay Road, Queensbury, NY 12804 -------------------------------------------------------------------------- - �FICE USE ONLY TAX MAP NO. PERMIT NO. +. _ . ; FEES: PERMIT RECREATION ENGINEERING (If applicable) tl� PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: C `c .OWNER: ADDRESS: S® a�e�e^ P�uje- ADDRESS: PHONE NOS. -79-!> _7 2-77 PHONE NOS. CONTACT PERSON FOR BUILDING &CODES COMPLIANCE: �--�� PHONE: LOCATION OF PROPERTY: C, HAS THERE BEEN A SITE PLAN REVIEW; VARIANCE OR SUBDIVISION APPROVAL? �ES ❑ NO IF SO, INDICATE APPLICATION NO. AND DATE OF APPROVAL: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT p d APPLY TO YOUR z p cn a U w w wa °O dPROJECT 0 J w u- w w Q w =Cw� � Vzw p z p z a ¢ e rn N (n O w l— U- CL M 0 SINGLE FAMILY ( �t� j _-7� `2 U p Z2 TWO-FAMILY MULTI-FAMILY "fir r (NO. of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL F. ATTACHED GARAGE(0)2O) X �1©o OTHER IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST: \ a000 FUEL TYPE: nn&6mcxl 0 HEAT TYPE: fcren� 'HOW MANY FIREPLACE(S): d AND/ OR WOODSTOVES(S): ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? 111t�lp , IS THIS A HISTORIC SITE? Do PROPOSED USE OF BUILDING OR ADDITION: �L• r-C • r��� P `Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 B 3-LGL 11-05 ARE THERE STRUCTURES NOT SHOWN ON PLOT ?'' ARE THERE EASEMENTS ON PROPERTY? , I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with lozoning regulations. 1 acknowledge that prior to occupying the facilities proposed,I-& my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facifirt3es prior to_ ssuence of a certificate of occupancy. I have read and agree 6-i e:above. Signed Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions.regarding required permits, the permit process, application requirements or to schedule an appointment) �...................... __........_...._....._.._..__.. Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said - zoning Laws of the Town of Queensbury. ; Application: ' ' , , BUILDING & CODES APPROVAL % ZONING APPROVAL 11 , o DATE o DATE 11 QUESTIONS? CALL 761.8256 OR EMAIL codes(c—Dgueensburv.net Office Use OnIV VISIT OUR WEBSITE FOR MORE INFORMATION www.gueensburv.net Operating Permit Issued: Yes No Occupancy Type: Construction Classification: Assembly Occupancy Limit: Special Conditions: Town of Queensbztry • Community Developinent Office - 742 Bay Road, Queensbury, NY 12804 zs.Sp1: Check Residential Plan Review: One & Two Family Dwellings [Y/N/NI,A, (2) Full sets of plans Over 1,500 sq. ft.—Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 50 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: indow Schedule With Glass Size oor Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade, 5.7 sq. ft. Grade,5.0 sq. ft. 24"(h)x 20"(w)min. 44"Max. Height above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofmg/Waterproofing Materials On Plans oundation Drainage On Plans,if required 6"Drop in 10' Exterior Grade gaming Cross Section For Each Roof Line, Vertical Fire Stopping Every 10' Where *equired Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors Stairway Headroom 6' 8' All Stairs 36"Width Stair Run and Rise Winder Run and Rise Spiral Not Allowed From 2 Story Smoke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance Hall Width, 36"min. Handrails More Than Four Risers On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4" in Ht. Safety Glazing Notes For Required Areas f Garage Fire Separation v .Garage Floor Sloped tic Access oof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Outside Lowest Sleeping Area, On Every Level& Interconnected Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed °n} Communiz q Development Office own of ur�cxshtrn/ ■ 742 Bay Road • Queens��ary, NOW York -12804 . , WINDOW SCHEDULE __________________ JOB SITE/ADDRESS: �� "'� DATE: b-4 1 o j OWNER: APPLICATION NO.: WINDOW- UNIT OR CLEAR CLEAR FT. OPENING WINDOW WINDOW STOCK ROUGH ROUGH SQ. SQ.FT. OPENING NO.OR SPECIAL HARDWARE OR ~ MANUFACTURER NUMBER OPENING OPENING EGRESS/CLEAR HEIGHT LETTER NAME MODEL/TYPE CALL WIDTH HEIGHT VENT OPENING I WIDTH D H I IN INSTRUCTIONS ON PLAN SIZE INCHES B 26-LTR 11-05 Community Development Office o'cvu ofQu en5J7111'y • 7142 Bay Road - Queoushurri/, Nev, "Fork- -12804 R BUILDING PERMIT CALCULATION SHEET: NATURAL LIGHT, VENTILATION AND EMERGENCY EGRESS REQUIREMENTS ACTUAL LIGHT REQUIRED SQUARE FOOT HABITABLE ROOM AREA OF ROOM IN LIGHT SQUARE VENTILATION•4% VENTILATION OPENING FOR REMARKS SQUARE FEET 8%OF ROOM FOOTAGE OF ROOM AREA SQUARE EGRESS AREA FOOTAGE c 157 (4�0 � � 5 W73 .. k k o V; ` QUESTIONS? CALL 761-8266 OR EMAIL cod s a aueensburv.net VISIT OUR WEBSITE FOR MORE INFORMATION www.duensburv.net B 10-LTP 11-20 MAP REFERENCES: GENEVA ESTATES BY.'MORSE ENGINEERING P.C. LAST REVISED:JULY 1, 1992 GENEVA DRIVE UnunE5 S84 D 21 '05 N E 2'( 75.0 9' 0 o I L i`b Qi I GRUSHED STONE d DRIVE f �J 40.83' r 30.W 2 5TORY WOOD FRAMED HOUSE A U OC O d. o - 3 LOT .00 1 w cl) LOT a aCV) ►--� Z LOT 10 ARE 15,964.61 sq.ft. cx, 0.37 acres h's 2 "I'J 100.00, �.: IRON ROD 'FOUND N 4 21 1 C. tS�� � 4N LAND5 N/F OF RUGGIERO Z� p O135 to MD SJ Date, April 0 u 's ""AAFAWg°""°`°'�°"DR A°aYM TO S A s A Map of a Survey made for Scale 1'=20' MAP BEARING A LICENSED U1ND SURVEYORS SEAL IS A &JZ,, vroLAvoN a SEC"nor.sue-olvlsaN 2,a n�E NEM YM STALE EDUC TM LAX' S t e v e s NCO COPIES 1 CON DE OWBrU1L OF TeNS SURVEY _ NARIaD wM AN ORNilIAL ov THE LAND SURVEYORS — M SNALL BE COMWIAFD TO BE YALID U COPRS. C l u.t e Enterprises CERT4TC M=wwCATED l IMM SO"MAT Trlls suRYEY WAS PREPARED w ACCORDANCE wM THE Land surveyors °r�CDE�PTANA�R IM�AD& BY THE NEW YORK STALE ASSOCIATION OF PROFE590NAL LAND SURVEYORS.SAID CERTFIC WIS%KL RUN ONLY TO ME PERSON FM wM7N THE SURVEY IS PREPARED.AND ON NIS M&F TO ME nLE Co1PANY.DOVET&"m 169 Haviland Road Queensbury, New York 12804 M W`E"S OF M MO "s"°"°W MD Town of Queensbury, Warren County, New York ro ME AS9ONEEs OF THE lFtoMw wsnTUTION.• Glute G2338 518 792-8474 New York Lie. No. 50135 1 1 1 N0. DATE DESCRIPTION DWG. NO. 95001-10 Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: ____!_-LU NAME: LOCATION:` PERMIT#: CJe-10 Final Survey Plot Plan A .. roved Denied The attached final survey has been received by the Dept.of Community Deveiopmentw Upon review the sutye has been: I C strator g Brawn, Admini Notes: ingwa} utlding.Cod � eS. Ver-aW.F0RMS*ina1 Survey L-�SueH wing AdnUUi0'aW.doe Queensbury Building & Code Enforcement - Residential FinvA4nspection Office No. (518) 761-8256 Arrive: a am/pm Date Inspection request received: inspectors Initials: NAME: MIT#: �(oLiZ� LOCATION: Sig-�'E,��, Off'— -�-- ATE: TYPE OF STRUCTURE: Comments: N A 4" Building Number Address visible from road Chimney Height/"B'Vent/Direct Vent Location Fresh Air intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Co fete/Exterior Finish Complete Platform at all exterior doors _ Handrail 4 or more risen; Guards at stairs deckspatios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall interior/Extedor Railings 34 inches to 38 inches Deck Brad /Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off a sed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety iazin /Window in stairwells safe Pain interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Batts backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access 1 gR.ft.-150 s .ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 N.ft. Emergency ress below arade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed I Heat Tra Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fire roofi /%hour fire door/door closer Duct work Sealed properly Gas Loge in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C 10 1 Temporary/ ermamkif L:1Building&Codes FormsUBuilding&Codes\Inspection FormsiResidential Final Inspection Form revised 100405.doc;Revised January 7,2008;Revised 6/26M Queensbu Building & Code Enforcement - Residenti nal spection O No. (518) 761-8256 Arrive: rt: a m/prn Date Inspection requ st received: Inspector's Initia v NAME: fE:! LOCATION: P TYPE OF STRUCTURE: Comments• N NIA 4' Building Number Address visible from road /�� - �-07 ChimneyHeight/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 Inches Roof Complete/Exterior Finish Complete !J-V7C) tz Platform at all exterior doors Handrail 4 or more risers Guards at stairs deckspatios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing I Handicapp2d Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off 2poled/re ulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen waterfi ht Safety glazing I Window in stairwells pteA glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access 1 qg.ft:150 a .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stoppiEg finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetroc k Underside minimum'/'Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed property Gas Logo in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Seole System/Sewer Dept. Ins ction Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C 10 Temporary/Permanent L:1Building&Codes FormslBuilding&Codesllnspedion Forms\Residenbal Final Inspection Form revised_100405.doc;Revised January 7,2008;Revised 6/26/08 Queensbury Building & Code Enforcement - Re 'dential Final Inspection Office No. (518)761-8256 Arrive: -3Da pm Date Inspection request received: _ Inspector's Initials: NAME: 4 PERMIT#: LOCATION: DATE: TYPE OF STRUCTURE: Comments: Yes No NIA 4' Building Number Address visible from road Chimney Height I W Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete _ Platform at all exterior doors Handrail 4 or more risers _ Guards at stairs deckspatios more than 30 inches above grade _ Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more J. Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Win in stairwells safe 1 in Interior Smoke Det ors/Carbon Monoxi Detecto Every level: Eves+Be I Outside every bed n�om pfea. - Inter Connected: ✓ Battery backup: Attic acoess 30 inches x 22 inches x 30 inches Sheight)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 .if Emergency egress below grade Gas Fumace shut-off within 30 feet or within line of site Oil Fumace shut-off at entrance to fumace area Fumace/Hot Water Heater operatin Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'/"G sum Basement stairs dosed rise>4 inches Garage Floor Pitched Garagle fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Are Fault Breaker in Bedrooms Flex Gas Pipe Bonding _ As Built Septic System/Sewer Dept. lns on Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C 10 Temporary/Permanent L:1Building&Codes FormslBuilding&CodeMinspection FormslResidential Final Inspection Form_revised_100405.doc;Revised January 7,2008; Revised 6/26/08 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE ELECTRICAL APPROVAL Permit No.... N2 11170 Cut- in Card No..................................... TZ-- Owner.. U�_................................................­*........................................................................ ........... .. Location.......F.....12-1 19 ........ Installation Consisting TZiV,-3,6 R-e-Z,'-p 46 <-1 r_Z-75 ............/..................................... ................................................... .................... ...................................................... ............................ ..................................................................................................................................... InstalledBy.................................6Z.,................................................Lic.No................................................... The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of makink-4ispections at any time, and if its rules are violated,the Company shall have the right to rev e hi ifica te* Date.... .................... INSPECTOR.../--I.... ...... ... .... ........................Member N.EP.A., . r ( U CIA- Rough Plumbing / Insulation Inspection ort Office No. (518) 761-8256 Date Inspection request received: Re / c � Queensbury Building & Code Enforcement Arrive: am/pm Depart: a pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: e � NAME: C PERMIT #: n LOCATION:(fo ).e r Cam. PECT ON: �-Ir3L6 D TYPE OF STRUCTURE: Y N NIA Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head ID,dov� 15 minutes Insulation esidential Check/ ommercial Check Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Rough Plumbing ! Insulation tnspe 0 on Report Office No. (518) 761-8256 Date Inspection reque e Queensbury Building &Code Enforcement Arrive: ', am/ art: :o am� 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT #: ! - LOCATION: INSPECT ON: J, TYPE OF STRUCTURE: Y N NIA Rough Plumbing/Nail Plates Plumbing Vent/Vents in Place 1 Y2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout eve 100 feet/change of direction Pressure Test Drain /Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping 5, P. Ifio 't5 Insulation LFfqsidential Chedc Commial Check nornt erc Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping insulation If required unheated spaces Combustion Air Su for Furnace Duct work sealed properly/No duct to COMMENTS: Rough Plumbing insulation ReporLrevised Nov 17 2003, revised February 15,2005, revised January 7,2008 / 4,00 �- { Septic Inspection Report Office No. (518) 761-8256 Date Inspection quest received: Queensbury Building &Code Enforcement Arrive: "> am/pti� '� : am/pm 742 Bay Rd., Queensbu NY 12804 Inspect s Initials: J r- NAME: PERMIT NO.: LOCATION: JJA INSPECT ON: RECHECK: Comments and/or diagram Soil T " / Loam / Clay Type of Water: unici al DWell Water Waterline se aration distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' + / - Y N N/A Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ~`' ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size e TypLe Building to tank k� Tank to Distribution Box Distribution Box to Field/ Pit Opening Sealed: N End Cap N Inlet/Outlet Pipes &Baffles Y N Location I Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. _..- Conforms as r Plot Plan Y N � / Engineer Report and As-Built Y N Location of System on Property: le�' Front Rear Left Side Right Side Middle Front Middle Rear So m s t Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Last revised 06/18/07 L:\Building&Codes Forms-OLD\Building&Codes\Inspection Forms\Septic Inspection Report.doc Framing / Firestopping Inspection Report U Office No. (516)761-8256 Date Inspection request received: A, C (oSc TU Queensbury Building&Code Enforcement Arrive. am/ Depart: ar qrdC` 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: G VT--�- . S PERMIT LOCATION: Cr e-Y,tV j' 57f I f2-.v INSPECT ON: TYPE OF STRUCTURE: Framing Y N NIA COMMENTS: Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. StairweNs 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %N 16 gauge 8 16D naas each side Draft stopping 1,000 sq.ft. floor trusses Anchor Bolts 6 ft. or less on center Abe and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in qvq min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceilin ll Windows Habitable Space/Bedrooms �4 in. (H) //20 in. (VII) 5.7 sf above/below grade 5.0 sf grade L:1BuiWing&Codes Forma-01-Deuilft&Cod"Urapedion FonsTmffft FndoMft Inspecpon Repwtdoc Revised January 7,2008 Foundation Inspection Report a° Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p� Depart:/i ! am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initial s:01 /T3 NAME: Lqe PERMIT#: LOCATION: r INSPECT ON: 12 — TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this pur Wse on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Founder Damppioofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width c above footing 6 miT for wet areas under slab Bali al g Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\lnspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: LL am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: I a NAME: PERMIT#: _ LOCATION: INSPECT ON: -2 ' TYPE OF STRUC Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\lnspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspectio uest received: Queensbury Building&Code Enforcement Arrive: '" pm - Depart.. am/ m PP 742 Bay Rd.,Queensbury,NY 12804 Inspector' 'tials: NAME: PERMIT#: LOCATION: C h SPECT ON: i�- C� TYPE OF STRUCTURA- �c ' /✓�_- �-9 Commen#s Y N N/A loot,ngs iers Monolithic Slab Reinforcement in Place r The contractor is responsible fo providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain.Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM V_ R__ Permit Number 0 5 REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheck So$ware Version 3.6 Release 2 Data filename: \\Clutel\shared data\Clutel\Rescheck\2008HO-1\8RALPH—I.RCK PROJECT TITLE: 24x26 Stock Colonial (1274) COUNTY: Warren STATE: New York HDD: 7635 CONSTRUCTION TYPE: Detached I or 2 Family HEATING TYPE: Non-Electric WINDOW /WALL RATIO: 0.13 DATE: 12/03/08 DATE OF PLANS: 12/3/2008 PROJECT DESCRIPTION: 8 Ralph Rd Queensbury, NY 12804 DESIGNER/CONTRACTOR: Clute Enterprises, Inc. 6 Holden Ave Queensbury, NY 12804 COMPLIANCE: Passes Maximum UA= 318 Your Home UA=290 8.8%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor TEA Ceiling 1: Flat Ceiling or Scissor Truss 1274 30.0 0.0 45 Wall 1: Wood Frame, 16" o.c. 1616 19.0 0.0 82 Window 1: Vinyl Frame:Double Pane 163 0.490 80 Door 1: Solid 40 0.230 9 Door 2: Glass 40 0.490 20 Basement Wall 1: Solid Concrete or Masonry 656 11.0 0.0 52 Wall height: 8.0' Depth below grade: 6.0' Insulation depth: 6.0' Floor 1: All-Wood Joist/Truss:Over Outside Air 52 19.0 0.0 2 Furnace 1: Forced Hot Air, 92 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York Statee Enervation Construction Code requirements. When a Registered Design Professional has stamped and sid this page,,tli are attesting that to the best of his/her knowledge, belief and professional judgment, suc�ans pecifications are in com ce with this Code. Builder/Designer Date 1 RFScheck Inspection Checklist New York State Energy Conservation Construction Code REScheck Solware Version 3.6 Release 2 DATE: 12/03/08 PROJECT TITLE: 24x26 Stock Colonial (1274) Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above-Grade Walls: [ ] ( 1. Wall 1: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: Basement Walls: [ ] 1. Basement Wall 1: Solid Concrete or Masonry, 8.0'ht/6.0'bg/6.0' insul, R-11.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Vinyl Frame:Double Pane, U-factor: 0.490 For windows without labeled U-factors, describe lmtures: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: Doors: [ ] 1. Door 1: Solid, U-factor: 0.230 Comments: [ ) 2. Door 2: Glass, U-factor: 0.490 Comments: Floors: [ ] 1. Floor 1: All-Wood Joist/Truss:Over Outside Air, R-19.0 cavity insulation Comments: Heating and Cooling Equipment: [ ] 1. Furnace 1: Forced Hot Air, 92 AFUE or higher Make and Model Number Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated, or 2)installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a 3" clearance from insulation. i Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating equipment efaciency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11_ [ ] Return ducts in unconditioned spaces (except basements)must be insulated to R- [ ] Return ducts in unconditioned spaces (except basements)must be insulated to R-2.. Insulation is not required on return ducts in basements. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 18113. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions of the Building Code of New York State, the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 'F or chilled fluids below 55 T must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(Fl Un to 1„ Un to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(F) 2"Runouts 1" and Less 1.25"to 2" 2. "to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for seed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) y RALPH ROAD 0000 Lu "00— NJ ! +•.. '%,. t?}� >fr � �'*,,. '`n.. tap i. y .. N °38'55 ' a 50.00' 155 78' O� ~ cq v, to CI, a 5° '48 a W 05 39' 6' W 0.9 '