Loading...
2007-400 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 4E Community Development- Building &Codes (518) 761-8256 CERTIFICATE 0-IF OCCUPANCY Permit Number. P20070400 Date Issued: Friday, July 16, 2010 This is to certify that work requested to be done as shown by Permit Number P20070400 has been completed. Location: 52 PINELLO Rd Tax Map Number. 523400-308-019-0001-053-000-0000 Owner. ROGER& GAIL MOREHOUSE Applicant: ROGER & GAIL MOREHOUSE This structure maybe occupied as a: Garage - 2 Cars Detached By Order of Town Board TOWN OF QUEENSBURY 9 Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan,` Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development Building&Codes (518)761-.8256 BUILDING PERMIT Permit Number: P20070400 Application Number. A20070400 Tax Map No: 523400-308-019-0001-053-000-0000 Permission is hereby granted to: ROGER& GAIL MOREHOUSE For property located at: 52 PINELLO Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other infonnation hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Constriction Value Owner Address: ROGER& GAIL MOREHOUSE 52 PINELLO Rd Garage-2 Cars Detached $10,000.00 QUEENSBURY,NY 12804 Total value $10,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2007-400 720 SQ FT DETACHED GARAGE $72.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Sunday,August 31, 2008 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To of ensb F a Au ust 31, 2007 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement ------------------------------------------------------------- , ---------------------- OFFICE USE ONLY r + TAX MAP NO. J PERMIT NO. r Oo / r r FEE PAID BLDG. &CODES APPROVAL , + + , r r , , +- --------------------------------------------------------------: 0-1—- -------? ACCESSORY STRUCTURE BUILDING PERMIT APPLICATION Use this application for any structure other than the Principal Structure(house)to include, but not limited to: garage,shed,greenhouse,dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Structures- Sheds/Fences. A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT.NO INSPECTIONS WILL BE MADE UNTIL THE APPLICANT HAS RECEIVED A VALID BUILDING PERMIT. OWNER.? I 0rehc�uS� INSTALLER/BUILDER: ADDRESS: ADDRESS: TY3+ �+ ADDRESS: PHONE NOS.193- 8004 &C l - �T'iAd r '-q Q.3 PHONE NOS. LOCATION OF PROPERTY: 5Q P;ne I!6 r4T?Wd SUBDIVISION NAME:LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION:—i�a PI`I�I i'aj&Cf ESTIMATED COST OF CONSTRUCTION: b 110,OOO ANY OTHER ACCESSORY STRUCTURES ON PROPERTY? IleS IF YES,PLEASE LIST: n ,�/ ` ; f- CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: 1T�41 /I!DrL0 u PHONE: `,/ �7 4- / 3 'l93'go* PROPOSED CONSTRUCTION 1*T FLOOR 2'FLOOR TOTAL PROPOSED SQ.FT SO,FT SO,FT FT.&IN. OPEN PORCH DECK 3 SEASON,COVERED OR ENCLOSED PORCH- BOATHOUSE BOATHOUSE WITH SUNDECK DOCK SHED POLE BARN DETACHED GARAGE(NO.OF CARS: A Plao Q laI v "f' OTHER ACCESSORY STRUCTURE: *CONSIDERED FLOOR AREA&MUST COMPLY WITH FAR(FLOOR AREA RATIO)REQUIREMENTS IF THE STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE. To the best of my knowledge,the statements contained in the application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes,the Zoning Ordinance,and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of Building and Codes,an As-Built Survey by a licensed surveyor,drawn to scale, QUESTIONS T CALL 761-8266 OR EMAIL showing actual location of all new construction. Codes .queensbury.net I have rea and agree to the above. VISIT OUR WESSITE FOR MORE INFORMATION www.gueensbury.net Signed ` ^� Dated: 1 07 Name/Title(Printed) Q l l m a r ehoLtse. Town of Queensbury- Community Development Office - 742 Bay Road, Queensbury, NY 12804 7`v� Queensbury Building & Code Enforcement - Residentia I Inspection Office No. (518)761-8256 Arrive: a rt: �� am/pm Date Inspection request received: Inspector's Initia . NAME: E IT#: LOCATION: _ i/ne D E: TYPE OF STRUCTURE: _ Comments: Y N A 4' Building Number Address visible from road l Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers ^ Guards at stairs decks ios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Extedor Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off ex osed/regulator 18 inches above grade interior priM/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazin interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in acoessibie area Crawl Spaces 18 inch x 24 inch access, 1 .ft:150 s .ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 s .ft. Emergency ress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to fumaoe area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed PropedY Gas Loge in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if regulred Okay to issue C/C or C 10 Temporary/PermanenjA LIZ LABuilding&Codes FormslBuilding&Codes\Inspecdon FormslResidential Final Inspection Form_revisec 100405.doc;Revised January 7,2008;Revised 6/26/08 11.1 Foundation Inspection Report Office No.(518)761-8256 Date Ins tion west received: Queensbury Building&Code Enforcement Arrive: arn/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspecto s Initials: NAME: Q PERMIT#: — � -� LOCATION: INSPECT ON: TYPE OF STRUC . Comments Y N N/A (� C F tings j liers Monolithic Slab 01' e_ Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement rn;rete.Mat s se on site. oun i n/nwbur kU4orce e Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. U Building&Codes Forms\Building&Codes\lnspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM