Manual J Load Short Form Job: 42 devin crt EC E9 W E Date: Oct 02,2017 Entire House D By: Plan: 1284 OCT u 4 2017 296.14-2-22 RC-000626-2017 For: a builders 42 de Cerrone Builders Inc. 42 devin crt, queensbury, ny 12804 42 Devin Court, Lot 22 SFD w/FP 1755 s.f., Garage 458 s.f. D- . Htg Clg Infiltration Outside db (°F) -4 85 Method Simplified Inside db (°F) 68 75 Construction quality Average Design TD (°F) 72 10 Fireplaces 1 (Average) Daily range - M Inside humidity (%) 50 50 Moisture difference(gr/Ib) 47 27 HEATING EQUIPMENT COOLING EQUIPMENT Make York Make York Trade YORK Trade HORIZONTAL DISCHARGE Model TM9X080B12MP11 Cond TCHD36S41S3 AHRI ref 2008691 Coil FC37A3XC1+TM8X060Al2MP11+S1-1TVM4G1 AHRI ref 3743636 Efficiency 95.5AFUE Efficiency 12.0 EER, 14.1 SEER Heating input 80000 Btuh Sensible cooling 23100 Btuh Heating output 76000 Btuh Latent cooling 9900 Btuh Temperature rise 63 °F Total cooling 33000 Btuh Actual air flow 1100 cfm Actual air flow 1100 cfm Air flow factor 0.010 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.81 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Room 1 1727 14585 3920 144 174 Room2 81 1151 269 11 12 Room3 72 2932 984 29 44 Room4 224 9126 3021 90 134 Room5 132 7364 1149 73 51 Room6 50 2980 978 29 43 Room7 169 7894 1663 78 74 Room8 111 5999 672 59 30 Room9 40 101 47 1 2 Room10 848 34553 6080 340 270 Room11 1718 24973 6033 246 267 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. 2017-Oct-0215:54:34 wri htsoftW Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 ..ott.langeworthy\Documents\York\42 devin crt.rup Calc=MJ7 Front Door faces: N Zntire House d 5172 111658 24815 1100 1100 Other equip loads 0 0 Equip. @ 0.90 RSM 22334 Latent cooling 5695 TOTALS 5172 111658 28029 1100 1100 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. wri htsoftPo 2017-Oct-0215:54:34 9 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 2 ACCA ...ott.langeworthy\Documents\York\42 devin crt.rup Calc=MJ7 Front Door faces: N Pro ect Summa Job: 42 devin crt 46Date: Oct 02,2017 Entire House By: Plan: 1284 Promect Information For: cerrone builders 42 devin crt, queensbury, ny 12804 Notes: Desicin Information Weather: Glens Falls AP, NY, US Winter Design Conditions Summer Design Conditions Outside db -4 OF Outside db 85 OF Inside db 68 OF Inside db 75 OF Design TD 72 OF Design TD 10 OF Daily range M Reative humidity 50 % Moisture difference 27 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 105042 Btuh Structure 23658 Btuh Ducts 6616 Btuh Ducts 1157 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 111658 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 22334 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 5695 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft2 5172 5172 Equipment latent load 5695 Btuh Volume (ft3) 46548 46548 Air changes/hour 0.90 0.40 Equipment total load 28029 Btuh Equiv.AVF (cfm) 698 310 Req. total capacity at 0.70 SHR 2.7 ton Heating Equipment Summary Cooling Equipment Summary Make York Make York Trade YORK Trade HORIZONTAL DISCHARGE Model TM9X080B12MP11 Cond TCHD36S41S3 AHRI ref 2008691 Coil FC37A3XC1+TM8X060Al2MP11+S1-1TVM4G1 AHRI ref 3743636 Efficiency 95.5AFUE Efficiency 12.0 EER, 14.1 SEER Heating input 80000 Btuh Sensible cooling 23100 Btuh Heating output76000 Btuh Latent cooling 9900 Btuh Temperature rise 63 OF Total cooling 33000 Btuh Actual air flow 1100 cfm Actual air flow 1100 cfm Air flow factor 0.010 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. WI'1 F1t50it 2017-Oct-0215:54:34 9 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 A ...ott.langeworthy\Documents\York\42 devin crt.rup Calc=MJ7 Front Door faces: N Manual S Compliance Report Job: 42devin crt Date: Oct 02,2017 Entire House By: Plan: 1284 Project • • For: cerrone builders 42 devin crt, queensbury, ny 12804 Cooling Equipment Design Conditions Outdoor design DB: 85.0°F Sensible gain: 24815 Btuh Entering coil DB: 75.3'F Outdoor design WB: 71.0°F Latent gain: 5695 Btuh Entering coil WB: 62.6°F Indoor design DB: 75.0°F Total gain: 30511 Btuh Indoor RH: 50% Estimated airflow: 1187 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: York Model: TCHD36S41S3+FC37A3XC1+TM8X060Al2MP11+S1-1TVM4G1 Actual airflow: 1100 cfm Sensible capacity: 0 Btuh 0% of load Latent capacity: 0 Btuh 0% of load Total capacity: 0 Btuh 0% of load SHR: 0% Heating Equipment Design Conditions Outdoor design DB: -4.0°F Heat loss. 111658 Btuh Entering coil DB: 65.0°F Indoor design DB: 68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: York Model: TM9X080612MP11 Actual airflow: 1100 cfm Output capacity: 76000 Btuh 68% of load Temp. rise: 50 °F Meets are all requirements of ACCA Manual S. ,1 2017-Oct-02 15:55:51 wrightsoft' Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 ACCA ...ott.langeworthy\Documents\York\42 devin crt.rup Calc=MJ7 Front Door faces: N + — — • Form Residential — RPER 1 ACCK® for HVAC System — •n (Loads, Equipment, 15 Mar 09 AirCadilrrrUGx&actmofkwm queensbury ny Header Information Contractor: REQUIRED ATTACHMENTS ATTACHED Manual J1 Form(and supporting worksheets): Yes ❑ No Mechanical license: or MJ1AE Form*(and supporting worksheets): Yes ❑ No ❑ OEM performance data(heating,cooling,blower): Yes ❑ No ❑ Building plan#: 1284 Manual D Friction Rate Worksheet: Yes ❑ No C] Duct distribution sketch: Yes ❑ No ❑ Home address(Street or Lot#,Block,Subdivision): 42 devin crt, Entire House HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature: _4 °F Orientation: Front Door faces North Indoor temperature: 68 °F North,East,West,South,Northeast,Northwest,Southeast,Southwest Total heat loss: 111658 Btuh Number of bedrooms: 2 Conditioned floor area: 5172 ft2 Summer Design Conditions Number of occupants: 0 Outdoor temperature: 85 °F Indoor temperature: 75 °F Windows Roof Grains difference: 27 gr/Ib 50% RH Eave overhang depth: 0 ft Sensible heat gain: 27572 Btuh Internal shade: none Latent heat gain: Blinds,drapes,etc. Eave 9 6328 Btuh Depth Window Total heat gain: 33901 Btuh Number of skylights: 0 HVAC EQUIPMENT SELECT • 4• Heating Equipment Data Cooling Equipment Data Blower Data Equipment type: Gas furnace EViement type: SplitAC Heating cfm: 1100 umace,Heatpump,Boiler,etc. it onditioner,Heat pump,etc. Cooling cfm: 1100 Model: York Model: York Static pressure: 0 in H2O TM9X080B12MP11 TCHD36S41 S3 Fan's rated external static pressure for design airflow Heating output capacity: 76P00 Btuh Total cooling capacity: 0 Btuh Heat pumps-capacity atwmterdesignoudoorconditions Sensible cooling capacity: 0 Btuh Aux.heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh DISTRIBUTIONHVAC DUCT •1 Design airflow: 1100 cfm Longest supply duct: 0 ft Duct Materials Used Equipment design ESP: 0 in H2O Longest return duct: 0 ft Trunk duct: Total device pressure losses: 0 in H2O Total effective length(TEL): 0 ft Available static pressure(ASP): 0 in H2O Friction rate: 0 in/100ft Branch duct: Sheet metal Friction Rate=ASP=(TELx 10U) I declare the load calculation,equipment,equipment selection and duct design were rigorously performed based on the building plan listed above. I understand the claims made on these forms will be subject to review and verification. Contractor's printed name: Contractor's signature: Date: Reserved for County,Town Municipality orAuthority having jurisdiction use. *Home qualifies for MJ1AE Form based on Abridged Edition Checklist + wrightSOW Right-Suite®Universal 2017 17.0.16 RSU25116 Load Short Form Job: 42 devin crt Date: Oct 02,2017 Entire House By: Plan: 1284 Project • • For: cerrone builders 42 devin crt, queensbury, ny 12804 Design Information Htg Clg Infiltration Outside db (°F) -4 85 Method Simplified Inside db (°F) 68 75 Construction quality Average Design TD (°F) 72 10 Fireplaces 1 (Average) Daily range - M Inside humidity (%) 50 50 Moisture difference(gr/Ib) 47 27 HEATING EQUIPMENT COOLING EQUIPMENT Make York Make York Trade YORK Trade HORIZONTAL DISCHARGE Model TM9X080B12MP11 Cond TCHD36S41S3 AHRI ref 2008691 Coil FC37A3XC1+TM8X060Al2MP11+S1-1TVM4G1 AHRI ref 3743636 Efficiency 95.5AFUE Efficiency 12.0 EER, 14.1 SEER Heating input 80000 Btuh Sensible cooling 23100 Btuh Heating output 76000 Btuh Latent cooling 9900 Btuh Temperature rise 63 OF Total cooling 33000 Btuh Actual air flow 1100 cfm Actual air flow 1100 cfm Air flow factor 0.010 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.81 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ftz) (Btuh) (Btuh) (cfm) (cfm) Room 1 1727 14585 3920 144 174 Room2 81 1151 269 11 12 Room3 72 2932 984 29 44 Room4 224 9126 3021 90 134 Room5 132 7364 1149 73 51 Room6 50 2980 978 29 43 Room7 169 7894 1663 78 74 Room8 111 5999 672 59 30 Room9 40 101 47 1 2 Room10 848 34553 6080 340 270 Room11 1718 24973 6033 246 267 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. wri htsoft`° 2017-Oct-0215:55:51 9 Right-Suite®Universal 2017 17.0.16 RSU25116 .4-01 ...ott.langeworthy\Documents\York\42 devin crt.rup Calc=MJ7 Front Door faces: N Page 1 _.Entire House d 5172 111658 24815 1100 1100 Other equip loads 0 0 Equip. @ 0.90 RSM 22334 Latent cooling 5695 TOTALS 5172 111658 28029 1100 1100 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. htSOftm 2017-Oct-02 15:55:51 wrl 9 Right-Suite®Universal 2017 17.0.16 RSU26116 Page 2 BCCA ...ott.langeworthy\Documents\York\42 devin crt.rup Calc=MJ7 Front Door faces: N Pro ect Summa Job: 42 devin crt • ., Date: Oct 02,2017 Entire House By: Plan: 1284 Proaect Information For: cerrone builders 42 devin crt, queensbury, ny 12804 Notes: Design Information Weather: Glens Falls AP, NY, US Winter Design Conditions Summer Design Conditions Outside db -4 OF Outside db 85 OF Inside db 68 OF Inside db 75 OF Design TD 72 OF Design TD 10 OF Daily range M Reative humidity 50 % Moisture difference 27 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 105042 Btuh Structure 23658 Btuh Ducts 6616 Btuh Ducts 1157 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) 0 Btuh Blower e) 0 Btuh Piping 0 Btuh Equipment load 111658 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 22334 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 5695 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ftz 5172 5172 Equipment latent load 5695 Btuh Volume(ft') 46548 46548 Air changes/hour 0.90 0.40 Equipment total load 28029 Btuh Equiv.AVF (cfm) 698 310 Req. total capacity at 0.70 SHR 2.7 ton Heating Equipment Summary Cooling Equipment Summary Make York Make York Trade YORK Trade HORIZONTAL DISCHARGE Model TM9X080B12MP11 Cond TCHD36S41S3 AHRI ref 2008691 Coil FC37A3XC1+TM8X060Al2MP11+S1-1TVM4G1 AHRI ref 3743636 Efficiency 95.5 AFUE Efficiency 12.0 EER, 14.1 SEER Heating input 80000 Btuh Sensible cooling 23100 Btuh Heating output 76000 Btuh Latent cooling 9900 Btuh Temperature rise 63 OF Total cooling 33000 Btuh Actual air flow 1100 cfm Actual air flow 1100 cfm Air flow factor 0.010 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. wri htsoft' 2017-Oct-0215:55:51 9 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 /4CCA ...ott.langeworthy\Documents\York\42 devin crt.rup Calc=MJ7 Front Door faces: N