Loading...
2007-411 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20070411 Date Issued: Wednesday, February 06, 2008 This is to certify that work requested to be done as shown by Permit Number P20070411 has been compieted. Location: 14 BERRY PATCH' Dr Tax Map Number. 523400-289-012-0001-018-000-0000 Owner. T & B ASSOCIATES LLC Applicant: T & B ASSOCIATES LLC This structure maybe occupied as a: Fireplace By Order of Town Board Garage - 2 Cars Attached TOWN OF QUEENSBURY Single Family Dwelling Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20070411 Application Number. A20070411 Tax Map No: 523400-289-012-0001-018-000-0000 Permission is hereby granted to: T&B ASSOCIATES LLC For property located at: 14 BERRY PATCH' Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Tyne of Construction Value Owner Address: T& B ASSOCIATES LLC Fireplace 36 FIELDSTONE Dr Garage-2 Cars Attached GANSEVOORT,NY 12831-0000 Single Family Dwelling $250,000.00 Total Value $250,000.00 Contractor or Builders Name/Address Electrical Inspection Agency Plans &Specifications 2007-411 2699.61 SQ FT SINGLE FAMILY DWELLING WITH 541.75 SQ FT GARAGE AND 1 FIREPLACE $378.08 PERMIT FEE PAID- THIS PERMIT EXPIRES: Thursday,July 10,2008 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To . QueensTate ay,July 10,2007 SIGNED BY for the Town of Queensbury. Director of Building Code nforcement 4-. ........................................... ./.._.._._...____..... f..__._.._.---------- . l�// / FFICE USE ONLY i r �i TAX MAP NO. l PERM_IT. /�/ 7 t FEES: PERWvAq REC EATION ENGINEERING ; 77 (If applicable) ; PRINCIPAL STRUCTU E: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: n�`� Nssoc``- OWNER: ^n ADDRESS: Q GP•cNseJo�� `�"1 ADDRESS: PHONE NOS. �9 PHONE NOS. CONTACT PERSON FOR BUILDING&CODES COMPLIANCE.- PHONE S LOCATION OF PROPERTY: SUBDIVISION NAME: V_k,� f"1 G t of e— PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT z APPLY TO YOUR z 0 d d w LL O oPROJECT O Q O � wOOw " LL 0U wzw � O Lu \/z ¢ a v) c�tQ a-X*a SINGLE FAMILY X J(/��1 C� 'l� a 09.�l TWO-FAMILY MULTI-FAMILY(NO._� TOWNHOUSE BUSINESS OFFICE RETAIL- �?:/ MERCANTILE FACTORY OR INDUSTRIAL �� ATTACHED GARAGE I�2�3) OTHE 05 ! �` Town of Qiteensburi/• Community Development Office 742 Bay Road, Queenshury, 12804 -----------0 p -------- OFFICE USE ONLY PROJECT NAME: STAFF INITIALS: BUILDING PERMIT SUBMISSION DATE: CHECKLIST FOR: SINGLE FAMILY DWELLING 1. Building Permit Application Completed? YES NO N /A .._................................ ................................. ................. 2 Energy Form or CheckMate Energy Code Compliance - Forms Complete? (2-copies) 3 Energy Code Inspector's Report from Checkmate Program? (2-copies) } 4 Septic application completely filled out? (if applicable) 5. f Electrical Inspection Form complete? 6. Two (2) sets of the plans each of the following: YES NO N /A Ca. Floor plans (s)? �j z ......................................._.........................._ . ......__......_.._...._� b. Foundation plan? c. Cross sections (s)? d. Elevations? . .. e. Window and door schedule? f g. Plans signed and sealed by registered architect or engineer? -# - -- . ................................. h. Window and door schedule? ................ ........_.................. ......_._.........:_......... ..............__...... Two (2) site plans showing location of the structure to be 7. built, location of well or water lines, location of septic system or sewer line? 8. Setbacks from property lines to new structure? { 8. Setbacks to neighboring wells and septic systems, : including onsite well and septic systems (if applicable)? 9. Driveway Permit? Tozan of Queensbury - Community Development Office - 742 Bay Road, Queensbury, NY 12804 Check Residential Plan Review: One& Two Family Dwellings Y/N/N/ (2)Full sets of plans Over 1,500 sq. ft.—Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: 4�inflow Schedule With Glass Size { Door Schedule/Main Entrance 36"Door mergency Escape Or Bedrooms and Habitable Space Abo e/Below grade,5.7 sq.ft. de,5.0 sq. ft. 4"(h)x 20"(w)min. 44"Max.Height above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK proofing/Waterproofing Materials On Plans /Foundation Drainage On Plans,if required ��'✓ 6"Drop in 10' Exterior Grade Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where uired Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors Stairway Headroom 6' 8'All Stairs 36"Width Stair Run and Rise Winder Run and Rise Spiral Not Allowed From 2nd Story Smoke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance Hall Width,36"nun. Handrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation ge Floor Sloped ttic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed For an EPA homeowner's guide: http://www.epa. "„ aov/npdes/pubs/homeowner guide Iona customize pdf ' OFFICE USE ONLY _________i TAX MAP NO. PERMIT NO. PERMIT FEE APPROVALS: ZONING TOWN CLERK ; APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT: A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. OWNER: �SSO INSTALLER: ADDRESS: ADDRESS: PHONE NOS. Zc7 q `_ PHONE NOS. LOCATION OF INSTALLATION: { P1�Ch L� \1 RESIDENCE BEDROOMS YEAR BUILT N OF X COMPUTATION= = TOTAL DAILY FLOW INFORMATION: 1980 or older X 150 gallon per bedroom = GARBAGE GRINDER INSTALLED? 1981-1991 X 130 gallon per bedroom 1992-present X 110 gallon per bedroom = SPA OR HOT TUB INSTALLED? PARCEL INFORMATION: / ✓ TOPOGRAPHY: FLAT ROL ING V STEEP SLOPE %SLOPE ✓ SOIL NATURE: SAND 7 LOAM CLAY OTHER ✓ GROUNDWATER: AT WHAT DEPTH? BEDROCK/IMPERVIOUS MATERIAL: AT WHAT DEPTH? ✓ DOMESTIC WATER SUPLY: MUNICIPAL WELL ; (If/well:water supply from any septic system absorption is: ft l.s ✓ PERCOLATION TEST: RATE IS ` -7 PER MIINUTE PER INCH(TEST TO BE COMPLETED BY A LICENSED PROFESSIONAL ENGINEER OR ARCHITECT) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). TANK SIZE: 14—SO GALLON (MIN. SIZE IS 1,000 GAL.)Add 250 gallons to the size of the septic tank for SY TEM TYPE: each garbage grinder, spa or whirlpool tub. ABSORPTION FIELD(WITH NO.2 STONE) Total length­tE,�­L_ft. Each trench1" _XS ❑ SEEPAGE PIT(S)(WITH NO. 3 STONE) How many? Size? ❑ALTERNATIVE SYSTEM Bed or other type? ❑ HOLDING TANK SYSTEM Total required capacity? Tank size? Number of tanks? NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations with respect to this application and agree ? CALL 761-8256 OR EMAIL to abide by these and all requirements of the Town of Queensbury codes0gueensbury.net Sanitary Sewage Disposal Ordinance. (::QQU:ESTIONS R WEBSITE FOR MORE INFORMATION r www.aueensburv.net Signature of Person Res nsible Date Town of Queensbury • Community Development Office - 742 Bap Road, Queensbury, NY 12804 Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: 01 am/p kl " p m D_ep m t am/ I Date Inspection request received: Inspector's" Initials: NAME: —T-R PERMIT#: LOCATION: ( cr $T/ _ DATE: �- TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 .inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Com Iete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches // Bathroom/Kitchen watertight A—C (f4 Safe glazing/Window in stairwells safeglazing ,(� Interior Smoke Detectors: Every level: Every Bedroom: t� Outside every bedroom area: Inter Connected: Batterybackup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft,150 s .ft.vents Ba oom Fans,if no window umbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum''/2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/d hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O Temporary/Permanent L:\Building&Codes Forms\Building&CodeslInspection Forms\Residential Final Inspection Form revised_l00405.doc Queensbury Building & Code Enforcement - Residential Fin U spectlon Office No. (518)761-8256 Arrive: 11* �,am/prn De Dart am/pm Date Inspection request received: Inspector's Initials: NAME: PERMIT#: LOCATION: n DATE: 02 TYPE OF STRUCTURE: Commen#s• Y o WA 4' BMMM Number Address visible from road Chimney Height/"B°Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Com late Platform at all exterior doors Handrail 4 or more risers V,001"OF Guards at stairs,decks,patios mare than 30 inches above grade Guard at stairwell at 34 inches or more ol Guard at deck,porches 36 inches or more Handrail Termination at Newe11 Post or Wail Intedor/Dde rior Railings 34 inches to 38 inches Deck Bras /Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch dearance to sill Mate Gas Valve shut-off e /regulator 18 inches above grade Interior pflyacy I trim I doors I main entrance 36 inches Bathroom/Kitchen watertight y Safety glaziry/Window in stairwells safety g!MM Interim Smoke Detedors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery badw : Attic access 30 inches x 22 inches x 30 inches in aooessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.150 sq.ft.vents Bathroom Fans,if no window Plumbing fbdures Foundation insulation Floor truss,draft stapping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace sthut-off within 30 feet or within fine of site Oil Furnace shut-off at entrance to furnace area Fumace/siat Water Heater operating Low water shut-off boiler Relief Va s installed/Heat Trio Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'A"Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitdhed Garage fireproofing/%tour fire door/door doser Dud work Sealed pLopeft Gas Logs in Sealed or re Final ElectricalAAM Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Fjpe Bonding As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance regored Flood Plain Certification,if reguhed Okay to issue C/C or C 10 Tem /Permanent L:16uilding&Codes Formsftfiding&CodesVnspection FormslResidential Final Inspection Form revised_100405.dw,Revised January 7,2008 Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: NAME: LOCATION: Rik PERMIT#: 1 Final Survey Plot Plan y, Auvroved Denied The attached final survey has been received by the Dept.of f Community Development. Upon review the survey has been: Craig Brown,Zoning Administrator Notes: L:\SueHetningway\Building.Codes.insp tion.FORMS1Fina1 Survey Zoning Adminisfttor.doc Septic Inspection Report Office No. (518) 761-8256 Date Ins request received: Queensbury Building&Code Enforcement Arrive: ©_ am�,part. am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's I itials: NAME: 7 S A, PERMIT NO.: LOCATION: INSPECT ON: RECHECK. .� Comments and/or diagram Sail T Sand m Clay' Type of Water: Mu ' 1 Well Water Waterline se ration distan ft. Well separation distance J ft. Other wells: ft. Absorption Field: Total length ft. Length of each trench ft, Depth of trenches ft. Size of Stone 7i Seepage Pits: Number Size: x Stone Size: —::—] Piping Type Building to tank Tank to Distribution Box Distribution Box ield Pit Ovenir N Partial End cap Inlet/Outlet Pipes&Baffles Y N Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as r Plot Plan V Y N ��L J �� i 3 G Engineer Repqrt and As-Built Y N Location of System on Property: Fron Rear `,Le Side Right Side Middle Fropt Middle Rear /A System Use Stags: _ V Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Last revised 021006 Last revised 1/6/05 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspectio ruest received: Queensbury Building&Code Enforcement Arrive: m/p +D�part: am/pm 742 Bay Road,Queensbury,NY 12804 Inspecto ' Ini is s- ' NAME: aG PERMIT#: -7 ell) LOCATION: INSPECT ON: (y TYPE OF STRUCTURE: Y N N/A Framing COMMENTS A *c Access 22"x 30"minimum ack Studs/Header ��p�,q Bracing/Bridgin Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 'h w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade I-r5ej L �+, (.�'�Q,,/D-')-5 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspectoo.pTequest received: fo -�- 0 Queensbury Building&Code Enforcement Arrive: am/ epart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector s Initials. NAME: (/ PERMIT#: / ' 7 LOCATION: j`{ INSPECT ON: 77 3 46v TYPE OF STRUCTURE: Y N NIA COMMENTS raming Attic Access 22"x 30"minimum C°\,—kPL<�C ' +g 5 ��A 1 p6s Jack Studs/Headersi�p J l Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in.or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 �/z(w) 16 gauge 8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2,3 hour ire , 3,4 hour irestoppi 11/-Lr5l�iu- Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/Z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade 2� 464. �� Le/moy L �kdV ��- �O C n1 Framing / Firestopping Inspection Report Office No.(518) 761-8256 Date Inspection re received: Queensbury Building&Code Enforcement Arrive: I `-3`%m- /pm D part: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: NAME: n C ' PERMIT#: � LOCATION: INSPECT ON: 2- TYPE OF STRUCTURE: Y N/A COMMENTS Framing - L Attic Access 22"x 30"minimum Jack Studs/Headers Bracing J Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed i 16 inch insulation in cavity min. I Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X I Ceiling/wall Windows Habitable Space/Bedrooms j 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade �=/o TCAES7A� Rough Plumbing / Insulation Ins ection Report Office No. (518) 761-8256 Date Inspe io re st received: Queensbury Building & Code Enforcement Arrive '� am/ Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspe or's Initials: NAME: Al PERMIT #: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N/A &Rouhumbin / Nail Plates Plumbin Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction Press r est Drain nt Air) ye5 P.S10 ft. above highest connection for 15 minutes Pressure Test Water u ply Piping Air/ fieaq 50 P. .I or 15 minutes Insulation Residential Check/ Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\lnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Foundation Inspection Report Office No.(518)761-8256 Date Ins ti request received: Queensbury Building&Code Enforcement Arrive: wpm t am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: TArt: NAME: !f Y�j S c ` `,+XS PERMIT#: _n LOCATION: L'N T C INSPECT ON: Z S TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM '�- -/o e��fl- Framing / Firestopping Inspection Report �r� - Office No. (518) 761-8256 Date Ins j�ectRitia request received: -7 Queensbury Building&Code Enforcement Arrive: am/p�� am/pm 742 Bay Road, Queensbury,NY 12804 Inspectorsls: NAME: f • A� W(-- PERMIT#: a(D0) — ! <f LOCATION: INSPECT ON: 7 TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams i Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. 1 Stairwells 36 in. or more _ Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2 w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center ce d Ovate hield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side ''/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: P> PERMIT#: LOCATION: C, INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Ba ill Approval bing Under Slab PV /Cast/Copper ' Foundation Insulation Interior/ xterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM ic- Rough Plumbing / Insulation Insp c 'on Report Office No. (518) 761-8256 Date Inspe on request received: Queensbury Building &Code Enforcement Arrlve:)T..4 -am/p Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NN&- NAME: APERMIT #: LOCATION: LZZ rqj4a0k,, INSPECT ON: .T-L . TYPE OF STRUCTURE: Y N N/A Rough Plumbing Nil Plates Plumbing VentlVents in Place 1/2 in imum Drain Size Washing Machine Drain 2 inch minimum CleAnout every 100 feet change of direction P essure Test Airra Cea t 5 P. 0 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation Residential Check Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\13uilding&CodesUnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: ;' —a-m/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: '` PERMIT#: CU l LOCATION: INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report d '( � P Office No. (518)761-8256 Date Inspection request received: 0,0 v-7 Queensbury Building&Code Enforcement Arrive: am/pm Depart: Lj_ am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: 1 u—p NAME: J 9k 6-4 PERMIT#: P�U� 'v �� LOCATION: INSPECT ON: TYPE OF STRUCTURE: 41 ` f Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this se on site. Foundation/Wallpour t Reinforcement in Place 00 Fooi4 Dowels or Keyway in place Foun 'on Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width inc�bgepo, s under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior i Exterior R_ Rough Grade 6 inch drop within 10 ft. U\Building&Codes Forms\Building&Codes\1nspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(51$)761-8256 Date Inspectio quest received: Queensbury Building&Code Enforcement Arrive: ' - pmi Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: s ' NAME: -TR d PERMIT#: 0-1 LOCATION: INSPECT ON: c�. TYPE OF STRUCTURE: C Comments �k Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for se on site. a enforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sunup Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Bjckfill Approval umbing Under Slab PVC/Cast/Copper Fo Rdg4pn Insulatio Interrio /Exterior ( Rough Grade 6 inch drop within 16 8. L:\Buiiding&Codes Fonns\Buiiding&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date InsMtion "quest received: Queensbury Building&Code Enforcement Arrive: am/p C Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspecto 's Initials: NAME: I PERMIT#: -� LOCATION: INSPECT ON�s TYPE OF STRUCTURE: Comments - - z Y N N/A L,footings Piers Monolithic Slab Reinforcement in Place — The contractor is responsible fo providing protection from free ng for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC l Cast l Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report-doc Last printed 12/20/2005 9:24:00 AM "I e3-///o7 - Foundation Inspection Report Office No.(518)761-8256 Date Ins ti request received: Queensbury Building&Code Enforcement Arrive: - am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspect is ihals: / NAME: 7 PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUC Comments Y N N/A Footings -Aerr' ff"< ��� Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\lnspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM g i i i �3 �a LOT „F. 392-Q8, w Nw O�00 Oj O 4 ` Co 4 cli MT1 E-" u i n .cG A.4 v ram, zo ASPHALT DRIVE ' dry DRIVEWAY � �w,a EASEMENT " �y _ W �w o� c~n o Y D7 411 Permit Number PXScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheck So$ware Version 3.6 Release 2 Data filename: C:\REScheck\14BERRYPATCH.RCK PROJECT TITLE: TB249.DGN- "THE BALLSTON I" COUNTY: Warren STATE: New York HDD: 7635 CONSTRUCTION TYPE: Detached 1 or 2 Family HEATING TYPE: Non-Electric WINDOW/WALL RATIO: 0.12 DATE: 06/25/07 DATE OF PLANS: 6/2007 PROJECT DESCRIPTION: #14 BERRY PATCH FARMINGTON GROVE TOWN OF QUEENSBURY, NY Of-NE,W), WARREN COUNTY tiP��L J.C G09'l� T&B ASSOCIATES CID DESIGNER/CONTRACTOR: DANFORTH H. CHRISS ' #125 KIPPLE ROAD SAND LAKE, NY 12153 �OAgOFE F COMPLIANCE: Passes Maximum UA= 640 Your Home UA= 469 26.7%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 178 48.0 0.0 5 Ceiling 2: Flat Ceiling or Scissor Truss 6 48.0 0.0 0 Ceiling 3: Flat Ceiling or Scissor Truss 1373 48.0 0.0 36 Ceiling 4: Flat Ceiling or Scissor Truss 10 30.0 0.0 0 Wall 1: Wood Frame, 16" o.c. 1553 19.0 0.0 78 Window 1: Vinyl Frame:Double Pane with Low-E 151 0.340 51 Door 1: Solid 18 0.160 3 Door 2: Solid 39 0.320 12 Door 3: Glass 40 0.310 12 Wall 2: Wood Frame, 16" o.c. 1357 19.0 0.0 73 Window 2: Vinyl Frame:Double Pane with Low-E 126 0.340 43 Window 3: Vinyl Frame:Double Pane with Low-E 21 0.330 7 Wall 3: Wood Frame, 16" o.c. 376 19.0 0.0 23 Basement Wall 1: Solid Concrete or Masonry 1071 11.0 0.0 65 Wall height: 7.6' Depth below grade: 6.6' Insulation depth: 7.6' Window 4: Vinyl Frame:Double Pane with Low-E 24 0.340 8 Door 4: Glass 40 0.310 12 Floor 1: All-Wood Joist/T russ:Over Outside Air 101 19.0 0.0 5 Floor 2: Slab-On-Grade:Unheated 53 10.0 36 Insulation depth: 4.0' Furnace 1: Forced Hot Air, 92 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page, they are attesting that to the best of his/her knowledge, belief, and professional judgmen such plans or specifications are in compliance with this Code. Builder/Designer - Date f' 25 7 �S OF Nam, J.C Y09 V 9 r Q ` W A 04 FESS ,�..- RES check Inspection Checklist New York State Energy Conservation Construction Code REScheck Sofware Version 3.6 Release 2 DATE: 06/25/07 PROJECT TITLE: TB249.DGN- "THE BALLSTON I" Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R48.0 cavity insulation Comments: 1ST FLR. FAMILY ROOM CEILING W/ 6" F.G. INSUL. & 6" PLUS BLOWN IN INSUL. [ ] 2. Ceiling 2: Flat Ceiling or Scissor Truss, R48.0 cavity insulation Comments: 1ST FLR. MUD ROOM/LAUNDRY CEILING W/ 6" F.G. INSUL. & 6"/PLUS BLOWN IN [ ] 3. Ceiling 3: Flat Ceiling or Scissor Truss, R48.0 cavity insulation Comments: 2ND FLR. CEILING W/6" F.G. INSUL. & 6"/PLUS BLOWN IN INSUL. [ ] 4. Ceiling 4: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: 1ST FLR. FIREPLACE CEILING W/ 10" F.G. Above-Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: 1ST FLR. 2X6 8 FT. WALLS W/FLR. RIM & W/ 6" F.G. [ ] 2. Wall 2: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: 2ND FLR. 2X6 8 FT. WALLS W/FLR. RIM & W/6" F.G. [ ] 3. Wall 3: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: WALK-OUT BASEMENT 2X6 STUD WALL W/ 6" F.G. Basement Walls: [ ] 1. Basement Wall 1: Solid Concrete or Masonry, 7.6' ht/6.6' bg/7.6' insul, R-11.0 cavity insulation Comments: WALK-OUT BASEMENT 8" POURED 8 FT. FOUNDATION WALLS W/ 3" F.G. Windows: [ ] 1. Window 1: Vinyl Frame:Double Pane with Low-E, U-factor: 0.340 For windows without labeled U-factors, describe iatures: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: 1ST FLR. SIMONTON PROFINISH VINYL SH LOW E/ARGON WINDOWS [ ] 2. Window 2: Vinyl Frame:Double Pane with Low-E, U-factor: 0.340 For windows without labeled U-factors, describe Matures: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: 2ND FLR. SIMONTON PROFINISH VINYL SH LOW E/ARGON WINDOWS [ ] 3. Window 3: Vinyl Frame:Double Pane with Low-E, U-factor: 0.330 For windows without labeled U-factors, describe ti atures: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: 2ND FLR. SIMONTON PROFINISH VINYL CUSTOM ROUND TOP LOW E/ARGON WH [ ] 4. Window 4: Vinyl Frame:Double Pane with Low-E, U-factor: 0.340 For windows without labeled U-factors, describe ieatures: #Panes Frame Type Thermal Break? [ ] Yes [ ]No Comments: WALK-OUT BASEMENT SIMONTON PROFINISH VINYL SH LOW E/ARGON WINDOV Doors: [ ] 1. Door 1: Solid, U-factor: 0.160 Comments: 1ST FLR. THERMA TRU 2868 INSUL. FIREDOOR [ ] 2. Door 2: Solid, U-factor: 0.320 Comments: IST FLR. THERMA TRU LOW-E INSUL. FRONT DOOR UNIT [ ] 3. Door 3: Glass, U-factor: 0.310 Comments: IST FLR. SIMONTON PROFINISH VINYL 6068 LOW E/ARGON SLIDING PATIO DOOR [ ] 4. Door 4: Glass, U-factor: 0.310 Comments: WALK-OUT BASEMENT SIMONTON PROFINISH VINYL 6068 LOW E/ARGON SLIDIN PATIO DOOR Floors: [ ] 1. Floor 1: All-Wood Joist/Truss:Over Outside Air, R-19.0 cavity insulation Comments: 2ND FLR. M. BED WALK-IN CLO. FLOOR OVER 2-CAR GARAGE W/MIN. 6" F.G. [ ] 2. Floor 2: Slab-On-Grade:Unheated, 4.0' insulation depth, R-10.0 continuous insulation Comments: WALK-OUT BASEMENT SLAB 2" RIGID BOARD INSUL. Slab insulation to extend down from the top of the slab to at least 4.0 ff. OR down to at least the bottom of the slab then horizontally for a total distance of4.0 1. Exterior insulation must have a rigid, opaque, weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in. below grade. Heating and Cooling Equipment: [ ] ( 1. Furnace 1: Forced Hot Air, 92 VUE or her Make and Model Number wc—�1'U' ra% L Qi., L -- k iat-( t:-4:R t±i is ijC/. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated, or 2)installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. If non-IC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11. [ ] Return ducts in unconditioned spaces (except basements)must be insulated to R- [ ] Return ducts in unconditioned spaces (except basements)must be insulated to R-2.. Insulation is not required on return ducts in basements. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 18113. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] The HVAC system must provide a means fDr balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] ( Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions ofthe Building Code of New York State, the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20% of the heating energy is from non-dcpletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 T must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature Fl Up to 1" Un to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Ranize F 2" Runouts 1" and Less 1.25" to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(fDr seed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) 07/10/2007 11:12 5188850613 T B ASSOC PAGE 02102 17 Rolling Brook Drive Clifton Park NY 12065 Cell (Slit) 744-5705 OWFU(518)373-0157 July 10, 2007 To Whom it may Concern; Lg 1 Res check requirements for LA4 Berry Patch, Queensbury is R48. Our insulation sub contracting company will achieve this by using R1.9 K24 which is 6 W of Batt FiberWass and R30 Blown Fiberglass at 12"totaling 18 1/4" of insulation. ,Attic nilers will be installed to view completion of work. If you have any questions please feel free to call me at(518)744- 5705. 'Thank You, Regina Falco Owner(20 yrs fence)